SMARTY IQ-GPRS / LTE, Version 1.1
CSV information ?
Status | active |
---|---|
Valid from | 30.03.2021 |
Valid until | 29.03.2029 |
Scheme | 🇩🇪 DE |
Manufacturer | Sagemcom Dr. Neuhaus GmbH |
Category | Other Devices and Systems |
Security level | AVA_VAN.5, ALC_FLR.2, EAL4+ |
Protection profiles | |
Maintenance updates | SMARTY IQ-LTE, Version 1.1, Hardware Version: DNT8209/3.3, Software Version 2.0.3036, Operating System Version DNT8209-21 (01.04.2022) Certification report |
SMARTY IQ_LTE, Version 1.1 (25.11.2024) Certification report | |
SMARTY IQ-LTE, Version 1.1, Hardware Version: DNT8209/3.3, Software Version 2.0.3036, Operating System Version DNT8209-21 (02.09.2022) Certification report Security target | |
SMARTY IQ-GPRS / LTE, Version 1.1, Hardware Version: DNT8209/3.3, Software Version: 2.0.3036, Operating System Version: DNT8209-21 (29.03.2023) Certification report |
Heuristics summary ?
Certificate ?
Extracted keywords
Security level
EAL 4, EAL 5, EAL 2, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5Certificates
BSI-DSZ-CC-0822-V3-2021Standards
ISO/IEC 15408, ISO/IEC 18045File metadata
Title | Certification Report BSI-DSZ-CC-0822-V3-2021 |
---|---|
Subject | Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH |
Keywords | "Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus" |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20210330140145+02'00' |
Modification date | D:20210415101023+02'00' |
Pages | 1 |
Creator | Writer |
Producer | LibreOffice 6.3 |
Certification report ?
Extracted keywords
Symmetric Algorithms
AES-, AES, CMACAsymmetric Algorithms
ECDSA, ECCHash functions
SHA-256, SHA-384, JHProtocols
SSH, TLSBlock cipher modes
GCMSecurity level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 5+, EAL 6, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5Protection profiles
BSI-CC-PP-0073-2014, BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-0822-V3-2021, BSI-DSZ-CC-0822-V2-2020, BSI-DSZ-CC-0957-, BSI-DSZ-CC-0822-Evaluation facilities
TÃœV InformationstechnikCertification process
being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, Technical Report BSI-DSZ-CC-0822-V3, Version 2, 2021-03-04, TÃœV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, 9] Configuration list for the TOE (confidential documents) filelist_os3036, 2021-03-16 filelist_3036, 2020-12-09 8209SE011_SMGw_CPU_USB.xls, Version 3.3Standards
FIPS180-4, FIPS 186-4, FIPS PUB 180-4, FIPS PUB 186, AIS 34, AIS 46, AIS 32, AIS 48, RFC5652, RFC5639, RFC6161, RFC6033, RFC4493, RFC5084, RFC5246, RFC8422, RFC 2104, RFC6090, RFC5288, RFC2104, RFC5289, RFC 8422, RFC 5652, RFC 5639, RFC 8289, RFC 5246, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065Technical reports
BSI TR-03109, BSI 7148File metadata
Title | Certification Report BSI-DSZ-CC-0822-V3-2021 |
---|---|
Subject | Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH |
Keywords | "Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus" |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20210726131537+02'00' |
Modification date | D:20210726135603+02'00' |
Pages | 28 |
Creator | Writer |
Producer | LibreOffice 6.3 |
Frontpage
Certificate ID | BSI-DSZ-CC-0822-V3-2021 |
---|---|
Certified item | SMARTY IQ-LTE, Version 1.1 |
Certification lab | BSI |
Developer | Sagemcom Dr. Neuhaus GmbH |
References
Outgoing- BSI-DSZ-CC-0822-V2-2020 - active - SMARTY IQ-LTE, Version 1.0
- BSI-DSZ-CC-0822-V4-2023 - active - SMARTY IQ-GPRS / LTE, Version 1.2
Security target ?
Extracted keywords
Symmetric Algorithms
AES, HMACAsymmetric Algorithms
ECCHash functions
SHA-256, SHA-384, SHA256, JHSchemes
MACProtocols
TLSElliptic Curves
P-256, P-384, NIST P-256, NIST P-384Block cipher modes
GCMTLS cipher suites
TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384, TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384JavaCard API constants
SECP256R1, SECP384R1Trusted Execution Environments
SESecurity level
EAL 4, EAL4, EAL 4 augmented, EAL4 augmentedClaims
OE.SM, OSP.SMSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_FLR.2, ALC_CMC.4, ALC_DEL.1, ALC_LCD.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5, ASE_CCL.1, ASE_INT.1, ASE_REQ.2, ASE_TSS.1Security Functional Requirements (SFR)
FAU_ARP, FAU_GEN, FAU_SAA, FAU_SAR, FAU_STG, FAU_GEN.2, FAU_STG.2, FAU_ARP.1, FAU_SAA.1, FAU_GEN.1, FAU_SAR.1, FAU_STG.4, FAU_STG.3, FAU_STG.1, FAU_GEN.2.1, FAU_STG.2.1, FAU_STG.2.2, FAU_STG.2.3, FAU_CON.1.2, FCO_NRO, FCO_NRO.2, FCO_NRO.2.1, FCO_NRO.2.2, FCO_NRO.2.3, FCO_NRO.1, FCS_CKM, FCS_COP, FCS_CKM.4, FCS_CKM.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_IFC, FDP_ACC.2, FDP_ACF.1, FDP_IFF, FDP_RIP.2, FDP_SDI.2, FDP_ITC.1, FDP_ITC.2, FDP_ACC, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACC.1, FDP_ACF, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_IFC.2, FDP_IFC.1, FDP_IFF.1, FDP_RIP, FDP_RIP.2.1, FDP_RIP.1, FDP_SDI, FDP_SDI.2.1, FDP_SDI.2.2, FDP_SDI.1, FIA_ATD, FIA_AFL, FIA_UAU, FIA_UID, FIA_USB, FIA_ATD.1, FIA_AFL.1, FIA_UAU.2, FIA_UAU.5, FIA_UAU.6, FIA_UID.2, FIA_USB.1, FIA_UID.1, FIA_ATD.1.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_UAU.1, FIA_UAU.2.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UAU.6.1, FIA_UID.2.1, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_SMR, FMT_MOF.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA, FMT_MSA.3, FMT_MOF, FMT_MOF.1.1, FMT_SMF, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MSA.1, FPR_CON, FPR_CON.1, FPR_PSE, FPR_CON.1.2, FPR_CON.1.1, FPR_PSE.1, FPR_PSE.1.1, FPR_PSE.1.2, FPR_PSE.1.3, FPT_FLS, FPT_RPL, FPT_STM, FPT_TST, FPT_PHP, FPT_FLS.1, FPT_RPL.1, FPT_STM.1, FPT_TST.1, FPT_PHP.1, FPT_FLS.1.1, FPT_RPL.1.1, FPT_RPL.1.2, FPT_STM.1.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_PHP.1.1, FPT_PHP.1.2, FTP_ITC, FTP_ITC.1Protection profiles
BSI-CC-PP-0073, BSI-CC-PP-0077-2013Certificates
BSI-DSZ-CC-0822Side-channel analysis
physical tampering, malfunctionStandards
FIPS 180-4, FIPS 197, FIPS 140-2, AIS20, AIS31, RFC 5289, RFC 5246, RFC 2104, RFC 5084, RFC 4493, RFC 5652, RFC 5905, RFC5905, RFC5246Technical reports
BSI TR-02102-2, BSI TR-03109, BSI TR-03109-1, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03116-3, BSI TR-03116-4, BSI TR-03109-4, BSI TR-03111, BSI 7586File metadata
Title | Protection Profile for the Gateway of a Smart Metering System (Smart Meter Gateway PP) |
---|---|
Subject | Schutzprofil für die Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen |
Keywords | Smart Meter System,Gateway,Common Criteria,Smart Meter Gateway PP |
Author | Dr. Neuhaus Telekommunikation |
Creation date | D:20210203170405+01'00' |
Modification date | D:20210203170405+01'00' |
Pages | 111 |
Creator | Microsoft® Office Word 2007 |
Producer | Microsoft® Office Word 2007 |
Heuristics ?
Extracted SARs
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_CMC.4, ALC_DEL.1, ALC_FLR.2, ALC_LCD.1, ASE_CCL.1, ASE_INT.1, ASE_REQ.2, ASE_TSS.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5Certificate versions
Name | Certificate ID | |
---|---|---|
Previous | ||
SMARTY IQ-LTE, Version 1.0 | BSI-DSZ-CC-0822-V2-2020 | Compare |
Next | ||
SMARTY IQ-GPRS / LTE, Version 1.2 | BSI-DSZ-CC-0822-V4-2023 | Compare |
SMARTY IQ-GPRS / LTE, Version 1.3 | BSI-DSZ-CC-0822-V5-2023 | Compare |
References ?
Updates ?
-
09.12.2024 The certificate data changed.
Certificate changed
The Maintenance Updates of the certificate were updated.
- The following values were added:
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.cc.CCCertificate.MaintenanceReport', 'maintenance_date': '2024-11-25', 'maintenance_title': 'SMARTY IQ_LTE, Version 1.1', 'maintenance_report_link': 'https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3ra2a_pdf.pdf', 'maintenance_st_link': None}]}
.
- The following values were added:
-
21.11.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The following values were inserted:
{'prev_certificates': ['BSI-DSZ-CC-0822-V2-2020'], 'next_certificates': ['BSI-DSZ-CC-0822-V4-2023', 'BSI-DSZ-CC-0822-V5-2023']}
.
- The following values were inserted:
-
17.10.2024 The certificate data changed.
Certificate changed
The Protection Profiles of the certificate were updated.
- The new value is
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.protection_profile.ProtectionProfile', 'pp_name': 'Protection Profile for the Gateway of a Smart Metering System', 'pp_eal': 'EAL4+', 'pp_link': 'https://www.commoncriteriaportal.org/files/ppfiles/pp0073b_pdf.pdf', 'pp_ids': {'_type': 'Set', 'elements': ['SMARTMETERGATEWAYPP_V1.3']}}]}
.
- The new value is
-
22.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '14b6fd70371d8122b0c3bdce9f79d523dd1302168e21eb0611cec1be2b1b1da9', 'txt_hash': 'b4ce6b6e80b2957b092ccfa1436fa7f11d3f34a46bf12ccdc890d5ef461c71fd'}
data. - The st property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'd1089803695cda2046aeabc48f7a0c1d14c9692a045b0e4fb58424807ee4c443', 'txt_hash': 'da1796a445d61af690213bf0676ff74e21ae1525563bcd8f0a8b6797530acc1e'}
data. - The cert property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '2205701b80e257896ce479fb697de63e6ce62586d13c337109f833fce638cb80', 'txt_hash': '070ccdb769606ffad95a667eecb078129e0df894e2429e729c77d5e2de6fafdb'}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
{'pdf_file_size_bytes': 656098, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 28, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20210726131537+02'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus"', '/ModDate': "D:20210726135603+02'00'", '/Producer': 'LibreOffice 6.3', '/Subject': 'Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH', '/Title': 'Certification Report BSI-DSZ-CC-0822-V3-2021', 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['https://www.bsi.bund.de/', 'https://tools.ietf.org/html/rfc5289', 'http://tools.ietf.org/html/rfc5652', 'https://tools.ietf.org/html/rfc5084', 'https://www.sogis.eu/', 'https://www.bsi.bund.de/zertifizierung', 'http://www.commoncriteriaportal.org/cc/', 'https://tools.ietf.org/html/rfc4493', 'https://www.bsi.bund.de/zertifizierungsreporte', 'http://www.ietf.org/rfc/rfc5246.txt', 'http://www.commoncriteriaportal.org/', 'https://www.bsi.bund.de/AIS']}}
. - The st_metadata property was set to
{'pdf_file_size_bytes': 1662000, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 111, '/Title': 'Protection Profile for the Gateway of a Smart Metering System (Smart Meter Gateway PP)', '/Author': 'Dr. Neuhaus Telekommunikation', '/Subject': 'Schutzprofil für die Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen', '/Keywords': 'Smart Meter System,Gateway,Common Criteria,Smart Meter Gateway PP', '/Creator': 'Microsoft® Office Word 2007', '/CreationDate': "D:20210203170405+01'00'", '/ModDate': "D:20210203170405+01'00'", '/Producer': 'Microsoft® Office Word 2007', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}
. - The cert_metadata property was set to
{'pdf_file_size_bytes': 238250, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 1, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20210330140145+02'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus"', '/ModDate': "D:20210415101023+02'00'", '/Producer': 'LibreOffice 6.3', '/Subject': 'Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH', '/Title': 'Certification Report BSI-DSZ-CC-0822-V3-2021', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}
. - The report_frontpage property was set to
{'DE': {'match_rules': ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)'], 'cert_id': 'BSI-DSZ-CC-0822-V3-2021', 'cert_item': 'SMARTY IQ-LTE, Version 1.1', 'developer': 'Sagemcom Dr. Neuhaus GmbH', 'cert_lab': 'BSI', 'ref_protection_profiles': 'Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014', 'cc_version': 'PP conformant Common Criteria Part 2 extended', 'cc_security_level': 'Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2'}}
. - The report_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-0822-V3-2021': 15, 'BSI-DSZ-CC-0822-V2-2020': 3, 'BSI-DSZ-CC-0957-': 1, 'BSI-DSZ-CC-0822-': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0073-2014': 3, 'BSI-CC-PP-0077-V2-2015': 2}}, 'cc_security_level': {'EAL': {'EAL 4': 8, 'EAL 5': 3, 'EAL 2': 3, 'EAL 1': 1, 'EAL 5+': 1, 'EAL 6': 1, 'EAL 4 augmented': 3}}, 'cc_sar': {'ALC': {'ALC_FLR.2': 4, 'ALC_FLR': 3}, 'AVA': {'AVA_VAN.5': 5}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {'TUV': {'TÃœV Informationstechnik': 3}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES-': 2, 'AES': 3}}, 'constructions': {'MAC': {'CMAC': 2}}}, 'asymmetric_crypto': {'ECC': {'ECDSA': {'ECDSA': 3}, 'ECC': {'ECC': 3}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA-256': 1, 'SHA-384': 1}}, 'JH': {'JH': 1}}, 'crypto_scheme': {}, 'crypto_protocol': {'SSH': {'SSH': 1}, 'TLS': {'TLS': {'TLS': 11}}}, 'randomness': {}, 'cipher_mode': {'GCM': {'GCM': 2}}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {'BSI': {'BSI TR-03109': 1, 'BSI 7148': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS180-4': 3, 'FIPS 186-4': 1, 'FIPS PUB 180-4': 1, 'FIPS PUB 186': 1}, 'BSI': {'AIS 34': 2, 'AIS 46': 2, 'AIS 32': 1, 'AIS 48': 1}, 'RFC': {'RFC5652': 4, 'RFC5639': 6, 'RFC6161': 2, 'RFC6033': 2, 'RFC4493': 6, 'RFC5084': 2, 'RFC5246': 6, 'RFC8422': 2, 'RFC 2104': 1, 'RFC6090': 4, 'RFC5288': 2, 'RFC2104': 2, 'RFC5289': 3, 'RFC 8422': 1, 'RFC 5652': 1, 'RFC 5639': 1, 'RFC 8289': 1, 'RFC 5246': 1}, 'ISO': {'ISO/IEC 15408': 4, 'ISO/IEC 18045': 4, 'ISO/IEC 17065': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'ConfidentialDocument': {'being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification': 1, 'Technical Report BSI-DSZ-CC-0822-V3, Version 2, 2021-03-04, TÃœV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014': 1, '9] Configuration list for the TOE (confidential documents) filelist_os3036, 2021-03-16 filelist_3036, 2020-12-09 8209SE011_SMGw_CPU_USB.xls, Version 3.3': 1}}}
. - The st_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-0822': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0073': 1, 'BSI-CC-PP-0077-2013': 1}}, 'cc_security_level': {'EAL': {'EAL 4': 5, 'EAL4': 1, 'EAL 4 augmented': 2, 'EAL4 augmented': 1}}, 'cc_sar': {'ADV': {'ADV_ARC.1': 1, 'ADV_IMP.1': 1}, 'AGD': {'AGD_OPE.1': 1}, 'ALC': {'ALC_FLR.2': 6, 'ALC_CMC.4': 1, 'ALC_DEL.1': 1, 'ALC_LCD.1': 1}, 'ATE': {'ATE_COV.2': 1, 'ATE_FUN.1': 1}, 'AVA': {'AVA_VAN.5': 7}, 'ASE': {'ASE_CCL.1': 1, 'ASE_INT.1': 1, 'ASE_REQ.2': 1, 'ASE_TSS.1': 1}}, 'cc_sfr': {'FAU': {'FAU_ARP': 10, 'FAU_GEN': 39, 'FAU_SAA': 15, 'FAU_SAR': 30, 'FAU_STG': 34, 'FAU_GEN.2': 10, 'FAU_STG.2': 10, 'FAU_ARP.1': 1, 'FAU_SAA.1': 4, 'FAU_GEN.1': 17, 'FAU_SAR.1': 6, 'FAU_STG.4': 3, 'FAU_STG.3': 3, 'FAU_STG.1': 8, 'FAU_GEN.2.1': 1, 'FAU_STG.2.1': 1, 'FAU_STG.2.2': 1, 'FAU_STG.2.3': 1, 'FAU_CON.1.2': 1}, 'FCO': {'FCO_NRO': 3, 'FCO_NRO.2': 10, 'FCO_NRO.2.1': 1, 'FCO_NRO.2.2': 1, 'FCO_NRO.2.3': 1, 'FCO_NRO.1': 1}, 'FCS': {'FCS_CKM': 51, 'FCS_COP': 68, 'FCS_CKM.4': 30, 'FCS_CKM.1': 16, 'FCS_CKM.2': 6, 'FCS_COP.1': 11, 'FCS_CKM.4.1': 1}, 'FDP': {'FDP_IFC': 29, 'FDP_ACC.2': 12, 'FDP_ACF.1': 11, 'FDP_IFF': 26, 'FDP_RIP.2': 8, 'FDP_SDI.2': 9, 'FDP_ITC.1': 12, 'FDP_ITC.2': 12, 'FDP_ACC': 2, 'FDP_ACC.2.1': 1, 'FDP_ACC.2.2': 1, 'FDP_ACC.1': 9, 'FDP_ACF': 1, 'FDP_ACF.1.1': 1, 'FDP_ACF.1.2': 1, 'FDP_ACF.1.3': 1, 'FDP_ACF.1.4': 1, 'FDP_IFC.2': 4, 'FDP_IFC.1': 12, 'FDP_IFF.1': 18, 'FDP_RIP': 2, 'FDP_RIP.2.1': 1, 'FDP_RIP.1': 1, 'FDP_SDI': 2, 'FDP_SDI.2.1': 1, 'FDP_SDI.2.2': 1, 'FDP_SDI.1': 1}, 'FIA': {'FIA_ATD': 3, 'FIA_AFL': 3, 'FIA_UAU': 5, 'FIA_UID': 3, 'FIA_USB': 3, 'FIA_ATD.1': 13, 'FIA_AFL.1': 10, 'FIA_UAU.2': 9, 'FIA_UAU.5': 9, 'FIA_UAU.6': 10, 'FIA_UID.2': 14, 'FIA_USB.1': 9, 'FIA_UID.1': 8, 'FIA_ATD.1.1': 1, 'FIA_AFL.1.1': 1, 'FIA_AFL.1.2': 1, 'FIA_UAU.1': 2, 'FIA_UAU.2.1': 1, 'FIA_UAU.5.1': 1, 'FIA_UAU.5.2': 1, 'FIA_UAU.6.1': 1, 'FIA_UID.2.1': 1, 'FIA_USB.1.1': 1, 'FIA_USB.1.2': 1, 'FIA_USB.1.3': 1}, 'FMT': {'FMT_SMR': 3, 'FMT_MOF.1': 9, 'FMT_SMF.1': 19, 'FMT_SMR.1': 29, 'FMT_MSA': 64, 'FMT_MSA.3': 12, 'FMT_MOF': 1, 'FMT_MOF.1.1': 1, 'FMT_SMF': 2, 'FMT_SMF.1.1': 1, 'FMT_SMR.1.1': 1, 'FMT_SMR.1.2': 1, 'FMT_MSA.1': 9}, 'FPR': {'FPR_CON': 6, 'FPR_CON.1': 12, 'FPR_PSE': 3, 'FPR_CON.1.2': 3, 'FPR_CON.1.1': 3, 'FPR_PSE.1': 8, 'FPR_PSE.1.1': 1, 'FPR_PSE.1.2': 1, 'FPR_PSE.1.3': 1}, 'FPT': {'FPT_FLS': 3, 'FPT_RPL': 3, 'FPT_STM': 3, 'FPT_TST': 3, 'FPT_PHP': 3, 'FPT_FLS.1': 9, 'FPT_RPL.1': 10, 'FPT_STM.1': 20, 'FPT_TST.1': 10, 'FPT_PHP.1': 8, 'FPT_FLS.1.1': 2, 'FPT_RPL.1.1': 1, 'FPT_RPL.1.2': 1, 'FPT_STM.1.1': 1, 'FPT_TST.1.1': 1, 'FPT_TST.1.2': 1, 'FPT_TST.1.3': 1, 'FPT_PHP.1.1': 1, 'FPT_PHP.1.2': 1}, 'FTP': {'FTP_ITC': 32, 'FTP_ITC.1': 9}}, 'cc_claims': {'OE': {'OE.SM': 4}, 'OSP': {'OSP.SM': 5}}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 3}}, 'constructions': {'MAC': {'HMAC': 1}}}, 'asymmetric_crypto': {'ECC': {'ECC': {'ECC': 3}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA-256': 3, 'SHA-384': 2, 'SHA256': 1}}, 'JH': {'JH': 1}}, 'crypto_scheme': {'MAC': {'MAC': 8}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 39}}}, 'randomness': {}, 'cipher_mode': {'GCM': {'GCM': 1}}, 'ecc_curve': {'NIST': {'P-256': 1, 'P-384': 1, 'NIST P-256': 1, 'NIST P-384': 1}}, 'crypto_engine': {}, 'tls_cipher_suite': {'TLS': {'TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256': 6, 'TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384': 6, 'TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256': 4, 'TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384': 4}}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'FI': {'physical tampering': 2, 'malfunction': 3}}, 'technical_report_id': {'BSI': {'BSI TR-02102-2': 1, 'BSI TR-03109': 1, 'BSI TR-03109-1': 8, 'BSI TR-03109-2': 1, 'BSI TR-03109-3': 1, 'BSI TR-03116-3': 1, 'BSI TR-03116-4': 1, 'BSI TR-03109-4': 1, 'BSI TR-03111': 1, 'BSI 7586': 1}}, 'device_model': {}, 'tee_name': {'IBM': {'SE': 2}}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS 180-4': 3, 'FIPS 197': 6, 'FIPS 140-2': 1}, 'BSI': {'AIS20': 1, 'AIS31': 1}, 'RFC': {'RFC 5289': 4, 'RFC 5246': 4, 'RFC 2104': 4, 'RFC 5084': 3, 'RFC 4493': 5, 'RFC 5652': 1, 'RFC 5905': 3, 'RFC5905': 1, 'RFC5246': 2}}, 'javacard_version': {}, 'javacard_api_const': {'curves': {'SECP256R1': 1, 'SECP384R1': 1}}, 'javacard_packages': {}, 'certification_process': {}}
. - The cert_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-0822-V3-2021': 1}}, 'cc_protection_profile_id': {}, 'cc_security_level': {'EAL': {'EAL 4': 2, 'EAL 5': 1, 'EAL 2': 1, 'EAL 4 augmented': 1}}, 'cc_sar': {'ALC': {'ALC_FLR.2': 1, 'ALC_FLR': 1}, 'AVA': {'AVA_VAN.5': 1}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {}, 'asymmetric_crypto': {}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'ISO': {'ISO/IEC 15408': 2, 'ISO/IEC 18045': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}
. - The report_filename property was set to
0822V3a_pdf.pdf
. - The st_filename property was set to
0822V3b_pdf.pdf
. - The cert_filename property was set to
0822V3c_pdf.pdf
.
The computed heuristics were updated.
- The cert_lab property was set to
['BSI']
. - The cert_id property was set to
BSI-DSZ-CC-0822-V3-2021
. - The report_references property was updated, with the
{'directly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0822-V4-2023']}, 'indirectly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0822-V5-2023', 'BSI-DSZ-CC-0822-V4-2023']}, 'directly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0822-V2-2020']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0822-V2-2020']}}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]}
values added.
- The report property was updated, with the
-
17.08.2024 The certificate data changed.
Certificate changed
The report_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3a_pdf.pdf
.
The st_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3b_pdf.pdf
.
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data. - The st property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data. - The cert property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
None
. - The st_metadata property was set to
None
. - The cert_metadata property was set to
None
. - The report_frontpage property was set to
None
. - The report_keywords property was set to
None
. - The st_keywords property was set to
None
. - The cert_keywords property was set to
None
. - The report_filename property was set to
None
. - The st_filename property was set to
None
. - The cert_filename property was set to
None
.
The computed heuristics were updated.
- The cert_lab property was set to
None
. - The cert_id property was set to
None
. - The report_references property was updated, with the
{'directly_referenced_by': None, 'indirectly_referenced_by': None, 'directly_referencing': None, 'indirectly_referencing': None}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]}
values discarded.
- The new value is
-
23.07.2024 The certificate was first processed.
New certificate
A new Common Criteria certificate with the product name SMARTY IQ-GPRS / LTE, Version 1.1 was processed.
Raw data
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "Other Devices and Systems",
"cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3c_pdf.pdf",
"dgst": "867fc6e2eb21f381",
"heuristics": {
"_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
"annotated_references": null,
"cert_id": "BSI-DSZ-CC-0822-V3-2021",
"cert_lab": [
"BSI"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_CCL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_IMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_LCD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_INT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_TSS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DEL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_REQ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_FUN",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_FLR",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMC",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_OPE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COV",
"level": 2
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"1.1"
]
},
"indirect_transitive_cves": null,
"next_certificates": [
"BSI-DSZ-CC-0822-V4-2023",
"BSI-DSZ-CC-0822-V5-2023"
],
"prev_certificates": [
"BSI-DSZ-CC-0822-V2-2020"
],
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V4-2023"
]
},
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V2-2020"
]
},
"indirectly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V5-2023",
"BSI-DSZ-CC-0822-V4-2023"
]
},
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V2-2020"
]
}
},
"scheme_data": null,
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": null,
"indirectly_referenced_by": null,
"indirectly_referencing": null
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2022-04-01",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3MA1a_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMARTY IQ-LTE, Version 1.1, Hardware Version: DNT8209/3.3, Software Version 2.0.3036, Operating System Version DNT8209-21"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2023-03-29",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3ra1a_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMARTY IQ-GPRS / LTE, Version 1.1, Hardware Version: DNT8209/3.3, Software Version: 2.0.3036, Operating System Version: DNT8209-21"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2024-11-25",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3ra2a_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMARTY IQ_LTE, Version 1.1"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2022-09-02",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3MA2a_pdf.pdf",
"maintenance_st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3MA2b_pdf.pdf",
"maintenance_title": "SMARTY IQ-LTE, Version 1.1, Hardware Version: DNT8209/3.3, Software Version 2.0.3036, Operating System Version DNT8209-21"
}
]
},
"manufacturer": "Sagemcom Dr. Neuhaus GmbH",
"manufacturer_web": "https://sagemcom.com",
"name": "SMARTY IQ-GPRS / LTE, Version 1.1",
"not_valid_after": "2029-03-29",
"not_valid_before": "2021-03-30",
"pdf_data": {
"_type": "sec_certs.sample.cc.CCCertificate.PdfData",
"cert_filename": "0822V3c_pdf.pdf",
"cert_frontpage": null,
"cert_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0822-V3-2021": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {},
"cc_sar": {
"ALC": {
"ALC_FLR": 1,
"ALC_FLR.2": 1
},
"AVA": {
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 2": 1,
"EAL 4": 2,
"EAL 4 augmented": 1,
"EAL 5": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"ISO": {
"ISO/IEC 15408": 2,
"ISO/IEC 18045": 2
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"cert_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20210330140145+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus\"",
"/ModDate": "D:20210415101023+02\u002700\u0027",
"/Producer": "LibreOffice 6.3",
"/Subject": "Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH",
"/Title": "Certification Report BSI-DSZ-CC-0822-V3-2021",
"pdf_file_size_bytes": 238250,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 1
},
"report_filename": "0822V3a_pdf.pdf",
"report_frontpage": {
"DE": {
"cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2",
"cc_version": "PP conformant Common Criteria Part 2 extended",
"cert_id": "BSI-DSZ-CC-0822-V3-2021",
"cert_item": "SMARTY IQ-LTE, Version 1.1",
"cert_lab": "BSI",
"developer": "Sagemcom Dr. Neuhaus GmbH",
"match_rules": [
"(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
],
"ref_protection_profiles": "Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014"
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 3
},
"ECDSA": {
"ECDSA": 3
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0822-": 1,
"BSI-DSZ-CC-0822-V2-2020": 3,
"BSI-DSZ-CC-0822-V3-2021": 15,
"BSI-DSZ-CC-0957-": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0073-2014": 3,
"BSI-CC-PP-0077-V2-2015": 2
}
},
"cc_sar": {
"ALC": {
"ALC_FLR": 3,
"ALC_FLR.2": 4
},
"AVA": {
"AVA_VAN.5": 5
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 2": 3,
"EAL 4": 8,
"EAL 4 augmented": 3,
"EAL 5": 3,
"EAL 5+": 1,
"EAL 6": 1
}
},
"cc_sfr": {},
"certification_process": {
"ConfidentialDocument": {
"9] Configuration list for the TOE (confidential documents) filelist_os3036, 2021-03-16 filelist_3036, 2020-12-09 8209SE011_SMGw_CPU_USB.xls, Version 3.3": 1,
"Technical Report BSI-DSZ-CC-0822-V3, Version 2, 2021-03-04, T\u00dcV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014": 1,
"being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1
}
},
"cipher_mode": {
"GCM": {
"GCM": 2
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"SSH": {
"SSH": 1
},
"TLS": {
"TLS": {
"TLS": 11
}
}
},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"TUV": {
"T\u00dcV Informationstechnik": 3
}
},
"hash_function": {
"JH": {
"JH": 1
},
"SHA": {
"SHA2": {
"SHA-256": 1,
"SHA-384": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"BSI": {
"AIS 32": 1,
"AIS 34": 2,
"AIS 46": 2,
"AIS 48": 1
},
"FIPS": {
"FIPS 186-4": 1,
"FIPS PUB 180-4": 1,
"FIPS PUB 186": 1,
"FIPS180-4": 3
},
"ISO": {
"ISO/IEC 15408": 4,
"ISO/IEC 17065": 2,
"ISO/IEC 18045": 4
},
"RFC": {
"RFC 2104": 1,
"RFC 5246": 1,
"RFC 5639": 1,
"RFC 5652": 1,
"RFC 8289": 1,
"RFC 8422": 1,
"RFC2104": 2,
"RFC4493": 6,
"RFC5084": 2,
"RFC5246": 6,
"RFC5288": 2,
"RFC5289": 3,
"RFC5639": 6,
"RFC5652": 4,
"RFC6033": 2,
"RFC6090": 4,
"RFC6161": 2,
"RFC8422": 2
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 3,
"AES-": 2
}
},
"constructions": {
"MAC": {
"CMAC": 2
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7148": 1,
"BSI TR-03109": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20210726131537+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus\"",
"/ModDate": "D:20210726135603+02\u002700\u0027",
"/Producer": "LibreOffice 6.3",
"/Subject": "Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH",
"/Title": "Certification Report BSI-DSZ-CC-0822-V3-2021",
"pdf_file_size_bytes": 656098,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"https://www.bsi.bund.de/zertifizierung",
"https://www.bsi.bund.de/zertifizierungsreporte",
"https://www.bsi.bund.de/",
"https://www.bsi.bund.de/AIS",
"https://tools.ietf.org/html/rfc4493",
"http://tools.ietf.org/html/rfc5652",
"https://www.sogis.eu/",
"https://tools.ietf.org/html/rfc5084",
"http://www.commoncriteriaportal.org/cc/",
"https://tools.ietf.org/html/rfc5289",
"http://www.ietf.org/rfc/rfc5246.txt",
"http://www.commoncriteriaportal.org/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 28
},
"st_filename": "0822V3b_pdf.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 3
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0822": 1
}
},
"cc_claims": {
"OE": {
"OE.SM": 4
},
"OSP": {
"OSP.SM": 5
}
},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0073": 1,
"BSI-CC-PP-0077-2013": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_IMP.1": 1
},
"AGD": {
"AGD_OPE.1": 1
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_DEL.1": 1,
"ALC_FLR.2": 6,
"ALC_LCD.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_INT.1": 1,
"ASE_REQ.2": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_FUN.1": 1
},
"AVA": {
"AVA_VAN.5": 7
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 5,
"EAL 4 augmented": 2,
"EAL4": 1,
"EAL4 augmented": 1
}
},
"cc_sfr": {
"FAU": {
"FAU_ARP": 10,
"FAU_ARP.1": 1,
"FAU_CON.1.2": 1,
"FAU_GEN": 39,
"FAU_GEN.1": 17,
"FAU_GEN.2": 10,
"FAU_GEN.2.1": 1,
"FAU_SAA": 15,
"FAU_SAA.1": 4,
"FAU_SAR": 30,
"FAU_SAR.1": 6,
"FAU_STG": 34,
"FAU_STG.1": 8,
"FAU_STG.2": 10,
"FAU_STG.2.1": 1,
"FAU_STG.2.2": 1,
"FAU_STG.2.3": 1,
"FAU_STG.3": 3,
"FAU_STG.4": 3
},
"FCO": {
"FCO_NRO": 3,
"FCO_NRO.1": 1,
"FCO_NRO.2": 10,
"FCO_NRO.2.1": 1,
"FCO_NRO.2.2": 1,
"FCO_NRO.2.3": 1
},
"FCS": {
"FCS_CKM": 51,
"FCS_CKM.1": 16,
"FCS_CKM.2": 6,
"FCS_CKM.4": 30,
"FCS_CKM.4.1": 1,
"FCS_COP": 68,
"FCS_COP.1": 11
},
"FDP": {
"FDP_ACC": 2,
"FDP_ACC.1": 9,
"FDP_ACC.2": 12,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 1,
"FDP_ACF.1": 11,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_IFC": 29,
"FDP_IFC.1": 12,
"FDP_IFC.2": 4,
"FDP_IFF": 26,
"FDP_IFF.1": 18,
"FDP_ITC.1": 12,
"FDP_ITC.2": 12,
"FDP_RIP": 2,
"FDP_RIP.1": 1,
"FDP_RIP.2": 8,
"FDP_RIP.2.1": 1,
"FDP_SDI": 2,
"FDP_SDI.1": 1,
"FDP_SDI.2": 9,
"FDP_SDI.2.1": 1,
"FDP_SDI.2.2": 1
},
"FIA": {
"FIA_AFL": 3,
"FIA_AFL.1": 10,
"FIA_AFL.1.1": 1,
"FIA_AFL.1.2": 1,
"FIA_ATD": 3,
"FIA_ATD.1": 13,
"FIA_ATD.1.1": 1,
"FIA_UAU": 5,
"FIA_UAU.1": 2,
"FIA_UAU.2": 9,
"FIA_UAU.2.1": 1,
"FIA_UAU.5": 9,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UAU.6": 10,
"FIA_UAU.6.1": 1,
"FIA_UID": 3,
"FIA_UID.1": 8,
"FIA_UID.2": 14,
"FIA_UID.2.1": 1,
"FIA_USB": 3,
"FIA_USB.1": 9,
"FIA_USB.1.1": 1,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_MOF": 1,
"FMT_MOF.1": 9,
"FMT_MOF.1.1": 1,
"FMT_MSA": 64,
"FMT_MSA.1": 9,
"FMT_MSA.3": 12,
"FMT_SMF": 2,
"FMT_SMF.1": 19,
"FMT_SMF.1.1": 1,
"FMT_SMR": 3,
"FMT_SMR.1": 29,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPR": {
"FPR_CON": 6,
"FPR_CON.1": 12,
"FPR_CON.1.1": 3,
"FPR_CON.1.2": 3,
"FPR_PSE": 3,
"FPR_PSE.1": 8,
"FPR_PSE.1.1": 1,
"FPR_PSE.1.2": 1,
"FPR_PSE.1.3": 1
},
"FPT": {
"FPT_FLS": 3,
"FPT_FLS.1": 9,
"FPT_FLS.1.1": 2,
"FPT_PHP": 3,
"FPT_PHP.1": 8,
"FPT_PHP.1.1": 1,
"FPT_PHP.1.2": 1,
"FPT_RPL": 3,
"FPT_RPL.1": 10,
"FPT_RPL.1.1": 1,
"FPT_RPL.1.2": 1,
"FPT_STM": 3,
"FPT_STM.1": 20,
"FPT_STM.1.1": 1,
"FPT_TST": 3,
"FPT_TST.1": 10,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ITC": 32,
"FTP_ITC.1": 9
}
},
"certification_process": {},
"cipher_mode": {
"GCM": {
"GCM": 1
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"TLS": {
"TLS": {
"TLS": 39
}
}
},
"crypto_scheme": {
"MAC": {
"MAC": 8
}
},
"device_model": {},
"ecc_curve": {
"NIST": {
"NIST P-256": 1,
"NIST P-384": 1,
"P-256": 1,
"P-384": 1
}
},
"eval_facility": {},
"hash_function": {
"JH": {
"JH": 1
},
"SHA": {
"SHA2": {
"SHA-256": 3,
"SHA-384": 2,
"SHA256": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {
"curves": {
"SECP256R1": 1,
"SECP384R1": 1
}
},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {
"FI": {
"malfunction": 3,
"physical tampering": 2
}
},
"standard_id": {
"BSI": {
"AIS20": 1,
"AIS31": 1
},
"FIPS": {
"FIPS 140-2": 1,
"FIPS 180-4": 3,
"FIPS 197": 6
},
"RFC": {
"RFC 2104": 4,
"RFC 4493": 5,
"RFC 5084": 3,
"RFC 5246": 4,
"RFC 5289": 4,
"RFC 5652": 1,
"RFC 5905": 3,
"RFC5246": 2,
"RFC5905": 1
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 3
}
},
"constructions": {
"MAC": {
"HMAC": 1
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7586": 1,
"BSI TR-02102-2": 1,
"BSI TR-03109": 1,
"BSI TR-03109-1": 8,
"BSI TR-03109-2": 1,
"BSI TR-03109-3": 1,
"BSI TR-03109-4": 1,
"BSI TR-03111": 1,
"BSI TR-03116-3": 1,
"BSI TR-03116-4": 1
}
},
"tee_name": {
"IBM": {
"SE": 2
}
},
"tls_cipher_suite": {
"TLS": {
"TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256": 6,
"TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256": 4,
"TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384": 6,
"TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384": 4
}
},
"vendor": {},
"vulnerability": {}
},
"st_metadata": {
"/Author": "Dr. Neuhaus Telekommunikation",
"/CreationDate": "D:20210203170405+01\u002700\u0027",
"/Creator": "Microsoft\u00ae Office Word 2007",
"/Keywords": "Smart Meter System,Gateway,Common Criteria,Smart Meter Gateway PP",
"/ModDate": "D:20210203170405+01\u002700\u0027",
"/Producer": "Microsoft\u00ae Office Word 2007",
"/Subject": "Schutzprofil f\u00fcr die Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen",
"/Title": "Protection Profile for the Gateway of a Smart Metering System (Smart Meter Gateway PP)",
"pdf_file_size_bytes": 1662000,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 111
}
},
"protection_profiles": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.protection_profile.ProtectionProfile",
"pp_eal": "EAL4+",
"pp_ids": {
"_type": "Set",
"elements": [
"SMARTMETERGATEWAYPP_V1.3"
]
},
"pp_link": "https://www.commoncriteriaportal.org/files/ppfiles/pp0073b_pdf.pdf",
"pp_name": "Protection Profile for the Gateway of a Smart Metering System"
}
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"ALC_FLR.2",
"AVA_VAN.5",
"EAL4+"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3b_pdf.pdf",
"state": {
"_type": "sec_certs.sample.cc.CCCertificate.InternalState",
"cert": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "2205701b80e257896ce479fb697de63e6ce62586d13c337109f833fce638cb80",
"txt_hash": "070ccdb769606ffad95a667eecb078129e0df894e2429e729c77d5e2de6fafdb"
},
"report": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "14b6fd70371d8122b0c3bdce9f79d523dd1302168e21eb0611cec1be2b1b1da9",
"txt_hash": "b4ce6b6e80b2957b092ccfa1436fa7f11d3f34a46bf12ccdc890d5ef461c71fd"
},
"st": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "d1089803695cda2046aeabc48f7a0c1d14c9692a045b0e4fb58424807ee4c443",
"txt_hash": "da1796a445d61af690213bf0676ff74e21ae1525563bcd8f0a8b6797530acc1e"
}
},
"status": "active"
}