This page was not yet optimized for use on mobile devices.
SMARTY IQ-GPRS / LTE, Version 1.2
Certificate details
| Status | active |
|---|---|
| Valid from | 04.05.2023 |
| Valid until | 03.05.2031 |
| Scheme | π©πͺ DE |
| Manufacturer | Sagemcom Dr. Neuhaus GmbH |
| Category | Other Devices and Systems |
| Security level | EAL4+, ALC_FLR.2, AVA_VAN.5 |
| Protection profiles |
Certificate
Extracted keywords
Security level
EAL 4, EAL 5, EAL 2, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5Certificates
BSI-DSZ-CC-0822-V4-2023Certification report
Extracted keywords
Symmetric Algorithms
AES-, AES, CMACAsymmetric Algorithms
ECDSA, ECCHash functions
SHA-256, SHA-384, JHProtocols
SSH, TLSBlock cipher modes
GCMSecurity level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 5+, EAL 6, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5Protection profiles
BSI-CC-PP-0073-2014, BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0822-V3-2021, BSI-DSZ-CC-0957-Evaluation facilities
TΓV InformationstechnikCertification process
being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, Technical Report BSI-DSZ-CC-0822-V4, Version 2, 2021-04-03, TΓV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, 23 / 27 Certification Report BSI-DSZ-CC-0822-V4-2023 [9] Configuration list for the TOE (confidential documents): filelist_OS_TFS, 2023-01-31 filelist_sln8209, 2023-01-31 8209SE011_SMGw_CPU_USB.xls, Version 3.3Standards
FIPS180-4, FIPS 186-4, FIPS PUB 180-4, FIPS PUB 186, AIS 34, AIS 46, AIS 32, AIS 38, AIS 48, RFC5652, RFC5639, RFC6161, RFC6033, RFC4493, RFC5084, RFC5246, RFC8422, RFC 2104, RFC6090, RFC5288, RFC2104, RFC5289, RFC 8422, RFC 5652, RFC 5639, RFC 8289, RFC 5246, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065Technical reports
BSI TR-03109, BSI TR-03116, BSI 7148Frontpage
| Certificate ID | BSI-DSZ-CC-0822-V4-2023 |
|---|---|
| Certified item | SMARTY IQ-LTE, Version 1.2 |
| Certification lab | BSI |
| Developer | Sagemcom Dr. Neuhaus GmbH |
Cross-references
Outgoing- BSI-DSZ-CC-0822-V3-2021 - active - SMARTY IQ-GPRS / LTE, Version 1.1
- BSI-DSZ-CC-0822-V5-2023 - active - SMARTY IQ-GPRS / LTE, Version 1.3
Security target
Extracted keywords
Symmetric Algorithms
AES, HMACAsymmetric Algorithms
ECCHash functions
SHA-256, SHA-384, SHA256, JHSchemes
MACProtocols
TLSBlock cipher modes
GCMTLS cipher suites
TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384, TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384JavaCard API constants
SECP256R1, SECP384R1Trusted Execution Environments
SESecurity level
EAL 4, EAL4, EAL 4 augmented, EAL4 augmentedClaims
OE.SM, OSP.SMSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_FLR.2, ALC_CMC.4, ALC_DEL.1, ALC_LCD.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5, ASE_CCL.1, ASE_INT.1, ASE_REQ.2, ASE_TSS.1Security Functional Requirements (SFR)
FAU_ARP, FAU_GEN, FAU_SAA, FAU_SAR, FAU_STG, FAU_GEN.2, FAU_STG.2, FAU_ARP.1, FAU_SAA.1, FAU_GEN.1, FAU_SAR.1, FAU_STG.4, FAU_STG.3, FAU_STG.1, FAU_GEN.2.1, FAU_STG.2.1, FAU_STG.2.2, FAU_STG.2.3, FAU_CON.1.2, FCO_NRO, FCO_NRO.2, FCO_NRO.2.1, FCO_NRO.2.2, FCO_NRO.2.3, FCO_NRO.1, FCS_CKM, FCS_COP, FCS_CKM.4, FCS_CKM.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_IFC, FDP_ACC.2, FDP_ACF.1, FDP_IFF, FDP_RIP.2, FDP_SDI.2, FDP_ITC.1, FDP_ITC.2, FDP_ACC, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACC.1, FDP_ACF, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_IFC.2, FDP_IFC.1, FDP_IFF.1, FDP_RIP, FDP_RIP.2.1, FDP_RIP.1, FDP_SDI, FDP_SDI.2.1, FDP_SDI.2.2, FDP_SDI.1, FIA_ATD, FIA_AFL, FIA_UAU, FIA_UID, FIA_USB, FIA_ATD.1, FIA_AFL.1, FIA_UAU.2, FIA_UAU.5, FIA_UAU.6, FIA_UID.2, FIA_USB.1, FIA_UID.1, FIA_ATD.1.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_UAU.1, FIA_UAU.2.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UAU.6.1, FIA_UID.2.1, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_SMR, FMT_MOF.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA, FMT_MSA.3, FMT_MOF, FMT_MOF.1.1, FMT_SMF, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MSA.1, FPR_CON, FPR_CON.1, FPR_PSE, FPR_CON.1.2, FPR_CON.1.1, FPR_PSE.1, FPR_PSE.1.1, FPR_PSE.1.2, FPR_PSE.1.3, FPT_FLS, FPT_RPL, FPT_STM, FPT_TST, FPT_PHP, FPT_FLS.1, FPT_RPL.1, FPT_STM.1, FPT_TST.1, FPT_PHP.1, FPT_FLS.1.1, FPT_RPL.1.1, FPT_RPL.1.2, FPT_STM.1.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_PHP.1.1, FPT_PHP.1.2, FTP_ITC, FTP_ITC.1Protection profiles
BSI-CC-PP-0073, BSI-CC-PP-0077-2013Certificates
BSI-DSZ-CC-0957-V2-2016Side-channel analysis
physical tampering, malfunctionStandards
FIPS 180-4, FIPS 197, FIPS 140-2, AIS20, AIS31, RFC 5289, RFC 5246, RFC 2104, RFC 5084, RFC 4493, RFC 5652, RFC 5905, RFC5905, RFC5246Technical reports
BSI TR-03109-1, BSI TR-02102-2, BSI TR-03109, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03116-3, BSI TR-03116-4, BSI TR-03109-4, BSI TR-03111, BSI 7586Cross-references
Outgoing- BSI-DSZ-CC-0957-V2-2016 - active - TCOS Smart Meter Security Module Version 1.0 Release 2/P60C144PVE
Automated analysis
Automated inference - use with caution
All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. This applies equally to the Cross-references section below. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.Certificate ID
BSI-DSZ-CC-0822-V4-2023Extracted SARs
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_CMC.4, ALC_DEL.1, ALC_FLR.2, ALC_LCD.1, ASE_CCL.1, ASE_INT.1, ASE_REQ.2, ASE_TSS.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5Cross-references
Loading...
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate was first processed.
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "Other Devices and Systems",
"cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V4c_pdf.pdf",
"dgst": "d543d721cc12007a",
"heuristics": {
"_type": "sec_certs.sample.cc_eucc_common.Heuristics",
"annotated_references": null,
"cert_id": "BSI-DSZ-CC-0822-V4-2023",
"cert_lab": [
"BSI"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"eal": "EAL4+",
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_LCD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_OPE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COV",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_CCL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_INT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_TSS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMC",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_FUN",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DEL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_FLR",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_IMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_REQ",
"level": 2
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"1.2"
]
},
"indirect_transitive_cves": null,
"next_certificates": null,
"prev_certificates": null,
"protection_profiles": {
"_type": "Set",
"elements": [
"6346b04de6859db3"
]
},
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V5-2023"
]
},
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V3-2021"
]
},
"indirectly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V7-2025",
"BSI-DSZ-CC-0822-V5-2023",
"BSI-DSZ-CC-0822-V6-2024"
]
},
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0822-V3-2021",
"BSI-DSZ-CC-0822-V2-2020"
]
}
},
"scheme_data": null,
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0957-V2-2016"
]
},
"indirectly_referenced_by": null,
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0957-V2-2016",
"BSI-DSZ-CC-0978-2016"
]
}
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": []
},
"manufacturer": "Sagemcom Dr. Neuhaus GmbH",
"manufacturer_web": "https://sagemcom.com",
"name": "SMARTY IQ-GPRS / LTE, Version 1.2",
"not_valid_after": "2031-05-03",
"not_valid_before": "2023-05-04",
"pdf_data": {
"_type": "sec_certs.sample.cc_eucc_common.PdfData",
"cert_filename": "0822V4c_pdf.pdf",
"cert_frontpage": null,
"cert_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0822-V4-2023": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {},
"cc_sar": {
"ALC": {
"ALC_FLR": 1,
"ALC_FLR.2": 1
},
"AVA": {
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 2": 1,
"EAL 4": 2,
"EAL 4 augmented": 1,
"EAL 5": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"ISO": {
"ISO/IEC 15408": 2,
"ISO/IEC 18045": 2
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"cert_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smartmeter Gateway, SMGW, Smart Grid, Sagemcom Dr. Neuhaus, Smarty IQ-LTE\"",
"/Subject": "Common Criteria, Certification, Zertifizierung, Smartmeter Gateway, SMGW, Smart Grid, Sagemcom Dr. Neuhaus, Smarty IQ-LTE",
"/Title": "Certification Report BSI-DSZ-CC-0822-V4-2023",
"pdf_file_size_bytes": 344320,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 1
},
"report_filename": "0822V4a_pdf.pdf",
"report_frontpage": {
"DE": {
"cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2",
"cc_version": "PP conformant Common Criteria Part 2 extended",
"cert_id": "BSI-DSZ-CC-0822-V4-2023",
"cert_item": "SMARTY IQ-LTE, Version 1.2",
"cert_lab": "BSI",
"developer": "Sagemcom Dr. Neuhaus GmbH",
"match_rules": [
"(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
],
"ref_protection_profiles": "Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014"
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 4
},
"ECDSA": {
"ECDSA": 3
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0822-V3-2021": 3,
"BSI-DSZ-CC-0822-V4-2023": 14,
"BSI-DSZ-CC-0957-": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0073-2014": 3,
"BSI-CC-PP-0077-V2-2015": 2
}
},
"cc_sar": {
"ALC": {
"ALC_FLR": 3,
"ALC_FLR.2": 4
},
"AVA": {
"AVA_VAN.5": 5
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 2": 3,
"EAL 4": 8,
"EAL 4 augmented": 3,
"EAL 5": 3,
"EAL 5+": 1,
"EAL 6": 1
}
},
"cc_sfr": {},
"certification_process": {
"ConfidentialDocument": {
"23 / 27 Certification Report BSI-DSZ-CC-0822-V4-2023 [9] Configuration list for the TOE (confidential documents): filelist_OS_TFS, 2023-01-31 filelist_sln8209, 2023-01-31 8209SE011_SMGw_CPU_USB.xls, Version 3.3": 1,
"Technical Report BSI-DSZ-CC-0822-V4, Version 2, 2021-04-03, T\u00dcV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014": 1,
"being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1
}
},
"cipher_mode": {
"GCM": {
"GCM": 2
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"SSH": {
"SSH": 1
},
"TLS": {
"TLS": {
"TLS": 12
}
}
},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"TUV": {
"T\u00dcV Informationstechnik": 3
}
},
"hash_function": {
"JH": {
"JH": 1
},
"SHA": {
"SHA2": {
"SHA-256": 1,
"SHA-384": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"BSI": {
"AIS 32": 1,
"AIS 34": 2,
"AIS 38": 1,
"AIS 46": 2,
"AIS 48": 1
},
"FIPS": {
"FIPS 186-4": 1,
"FIPS PUB 180-4": 1,
"FIPS PUB 186": 1,
"FIPS180-4": 3
},
"ISO": {
"ISO/IEC 15408": 4,
"ISO/IEC 17065": 2,
"ISO/IEC 18045": 4
},
"RFC": {
"RFC 2104": 1,
"RFC 5246": 1,
"RFC 5639": 1,
"RFC 5652": 1,
"RFC 8289": 1,
"RFC 8422": 1,
"RFC2104": 2,
"RFC4493": 6,
"RFC5084": 2,
"RFC5246": 6,
"RFC5288": 2,
"RFC5289": 3,
"RFC5639": 6,
"RFC5652": 4,
"RFC6033": 2,
"RFC6090": 4,
"RFC6161": 2,
"RFC8422": 2
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 3,
"AES-": 2
}
},
"constructions": {
"MAC": {
"CMAC": 2
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7148": 1,
"BSI TR-03109": 1,
"BSI TR-03116": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smartmeter Gateway, SMGW, Smart Grid, Sagemcom Dr. Neuhaus, Smarty IQ-LTE\"",
"/Subject": "Common Criteria, Certification, Zertifizierung, Smartmeter Gateway, SMGW, Smart Grid, Sagemcom Dr. Neuhaus, Smarty IQ-LTE",
"/Title": "Certification Report BSI-DSZ-CC-0822-V4-2023",
"pdf_file_size_bytes": 561809,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"https://www.bsi.bund.de/zertifizierung",
"http://www.commoncriteriaportal.org/",
"https://www.bsi.bund.de/",
"https://www.commoncriteriaportal.org/",
"https://www.sogis.eu/",
"https://www.bsi.bund.de/zertifizierungsreporte",
"https://www.bsi.bund.de/AIS",
"http://www.commoncriteriaportal.org/cc/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 27
},
"st_filename": "0822V4b_pdf.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 3
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0957-V2-2016": 1
}
},
"cc_claims": {
"OE": {
"OE.SM": 4
},
"OSP": {
"OSP.SM": 5
}
},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0073": 4,
"BSI-CC-PP-0077-2013": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_IMP.1": 1
},
"AGD": {
"AGD_OPE.1": 1
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_DEL.1": 1,
"ALC_FLR.2": 6,
"ALC_LCD.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_INT.1": 1,
"ASE_REQ.2": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_FUN.1": 1
},
"AVA": {
"AVA_VAN.5": 7
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 5,
"EAL 4 augmented": 2,
"EAL4": 1,
"EAL4 augmented": 1
}
},
"cc_sfr": {
"FAU": {
"FAU_ARP": 10,
"FAU_ARP.1": 1,
"FAU_CON.1.2": 1,
"FAU_GEN": 39,
"FAU_GEN.1": 17,
"FAU_GEN.2": 10,
"FAU_GEN.2.1": 1,
"FAU_SAA": 15,
"FAU_SAA.1": 4,
"FAU_SAR": 30,
"FAU_SAR.1": 6,
"FAU_STG": 34,
"FAU_STG.1": 8,
"FAU_STG.2": 10,
"FAU_STG.2.1": 1,
"FAU_STG.2.2": 1,
"FAU_STG.2.3": 1,
"FAU_STG.3": 3,
"FAU_STG.4": 3
},
"FCO": {
"FCO_NRO": 3,
"FCO_NRO.1": 1,
"FCO_NRO.2": 11,
"FCO_NRO.2.1": 1,
"FCO_NRO.2.2": 1,
"FCO_NRO.2.3": 1
},
"FCS": {
"FCS_CKM": 51,
"FCS_CKM.1": 16,
"FCS_CKM.2": 6,
"FCS_CKM.4": 30,
"FCS_CKM.4.1": 1,
"FCS_COP": 68,
"FCS_COP.1": 11
},
"FDP": {
"FDP_ACC": 2,
"FDP_ACC.1": 9,
"FDP_ACC.2": 12,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 1,
"FDP_ACF.1": 11,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_IFC": 29,
"FDP_IFC.1": 12,
"FDP_IFC.2": 4,
"FDP_IFF": 26,
"FDP_IFF.1": 18,
"FDP_ITC.1": 12,
"FDP_ITC.2": 12,
"FDP_RIP": 2,
"FDP_RIP.1": 1,
"FDP_RIP.2": 8,
"FDP_RIP.2.1": 1,
"FDP_SDI": 2,
"FDP_SDI.1": 1,
"FDP_SDI.2": 9,
"FDP_SDI.2.1": 1,
"FDP_SDI.2.2": 1
},
"FIA": {
"FIA_AFL": 3,
"FIA_AFL.1": 10,
"FIA_AFL.1.1": 1,
"FIA_AFL.1.2": 1,
"FIA_ATD": 3,
"FIA_ATD.1": 13,
"FIA_ATD.1.1": 1,
"FIA_UAU": 5,
"FIA_UAU.1": 2,
"FIA_UAU.2": 9,
"FIA_UAU.2.1": 1,
"FIA_UAU.5": 9,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UAU.6": 10,
"FIA_UAU.6.1": 1,
"FIA_UID": 3,
"FIA_UID.1": 8,
"FIA_UID.2": 14,
"FIA_UID.2.1": 1,
"FIA_USB": 3,
"FIA_USB.1": 9,
"FIA_USB.1.1": 1,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_MOF": 1,
"FMT_MOF.1": 9,
"FMT_MOF.1.1": 1,
"FMT_MSA": 64,
"FMT_MSA.1": 9,
"FMT_MSA.3": 12,
"FMT_SMF": 2,
"FMT_SMF.1": 19,
"FMT_SMF.1.1": 1,
"FMT_SMR": 3,
"FMT_SMR.1": 29,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPR": {
"FPR_CON": 6,
"FPR_CON.1": 12,
"FPR_CON.1.1": 3,
"FPR_CON.1.2": 3,
"FPR_PSE": 3,
"FPR_PSE.1": 9,
"FPR_PSE.1.1": 1,
"FPR_PSE.1.2": 1,
"FPR_PSE.1.3": 1
},
"FPT": {
"FPT_FLS": 3,
"FPT_FLS.1": 9,
"FPT_FLS.1.1": 2,
"FPT_PHP": 3,
"FPT_PHP.1": 8,
"FPT_PHP.1.1": 1,
"FPT_PHP.1.2": 1,
"FPT_RPL": 3,
"FPT_RPL.1": 10,
"FPT_RPL.1.1": 1,
"FPT_RPL.1.2": 1,
"FPT_STM": 3,
"FPT_STM.1": 20,
"FPT_STM.1.1": 1,
"FPT_TST": 3,
"FPT_TST.1": 10,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ITC": 32,
"FTP_ITC.1": 9
}
},
"certification_process": {},
"cipher_mode": {
"GCM": {
"GCM": 1
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"TLS": {
"TLS": {
"TLS": 40
}
}
},
"crypto_scheme": {
"MAC": {
"MAC": 8
}
},
"device_model": {},
"ecc_curve": {
"NIST": {
"NIST P-256": 2,
"NIST P-384": 1,
"P-256": 2,
"P-384": 1
}
},
"eval_facility": {},
"hash_function": {
"JH": {
"JH": 1
},
"SHA": {
"SHA2": {
"SHA-256": 3,
"SHA-384": 2,
"SHA256": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {
"curves": {
"SECP256R1": 2,
"SECP384R1": 1
}
},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {
"FI": {
"malfunction": 3,
"physical tampering": 2
}
},
"standard_id": {
"BSI": {
"AIS20": 1,
"AIS31": 1
},
"FIPS": {
"FIPS 140-2": 1,
"FIPS 180-4": 3,
"FIPS 197": 6
},
"RFC": {
"RFC 2104": 4,
"RFC 4493": 5,
"RFC 5084": 3,
"RFC 5246": 4,
"RFC 5289": 4,
"RFC 5652": 1,
"RFC 5905": 3,
"RFC5246": 2,
"RFC5905": 1
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 3
}
},
"constructions": {
"MAC": {
"HMAC": 1
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7586": 1,
"BSI TR-02102-2": 1,
"BSI TR-03109": 1,
"BSI TR-03109-1": 9,
"BSI TR-03109-2": 1,
"BSI TR-03109-3": 1,
"BSI TR-03109-4": 1,
"BSI TR-03111": 1,
"BSI TR-03116-3": 1,
"BSI TR-03116-4": 1
}
},
"tee_name": {
"IBM": {
"SE": 2
}
},
"tls_cipher_suite": {
"TLS": {
"TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256": 2,
"TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256": 2,
"TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384": 2,
"TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384": 2
}
},
"vendor": {},
"vulnerability": {}
},
"st_metadata": {
"/Author": "Dr. Neuhaus Telekommunikation",
"/Keywords": "Smart Meter System, Gateway, Common Criteria, Smart Meter Gateway PP",
"/Subject": "Schutzprofil f\u00fcr die Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen",
"/Title": "Sagemcom Dr. Neuhaus SMARTY IQ-LTE Security Target",
"pdf_file_size_bytes": 2022384,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 111
}
},
"protection_profile_links": {
"_type": "Set",
"elements": [
"https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073b_pdf.pdf"
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V4a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"EAL4+",
"ALC_FLR.2",
"AVA_VAN.5"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V4b_pdf.pdf",
"state": {
"_type": "sec_certs.sample.cc_eucc_common.InternalState",
"cert": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"source_hash": "f8a469809f32d5c0c3bd316210375358793e35e88bad152d61331ec4dad6888a",
"txt_hash": "81c504ad3f32e44fdb68c44260259834a71978522cdf55fb037c325df9effb05"
},
"report": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"source_hash": "87e2a43699cb506ee53ac4a0813ab9666aa2c73bbc66684ac8fc3d34921c211b",
"txt_hash": "3ebaf172a0ed66c63dc81047ebfbe5c35da5324b826539020dd94717e20344fc"
},
"st": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"source_hash": "63cfcabb1caabb2892e8582a9cee49a4203a436484ba4ebe012418ed5bfcd008",
"txt_hash": "b4dedecf320fadf24f61cf2b3eb8761f897cf4ce0f2d792adaae35ce730cac8f"
}
},
"status": "active"
}