Protection Profile for the Gateway of a Smart Metering System

Profile details

Status active
Valid from 04.04.2014
Scheme ๐Ÿ‡ฉ๐Ÿ‡ช DE
Category Network and Network-Related Devices and Systems
Security level EAL4+, ALC_FLR.2, AVA_VAN.5

Certification report

Extracted keywords

Security level
EAL 4, EAL1, EAL4, EAL3, EAL5, EAL7, EAL2, EAL6, EAL 4 augmented, ITSEC Evaluation
Security Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.1, ADV_FSP.2, ADV_FSP.3, ADV_FSP.4, ADV_FSP.5, ADV_FSP.6, ADV_IMP.1, ADV_IMP.2, ADV_INT.1, ADV_INT.2, ADV_INT.3, ADV_SPM.1, ADV_TDS.1, ADV_TDS.2, ADV_TDS.3, ADV_TDS.4, ADV_TDS.5, ADV_TDS.6, ADV_ARC, ADV_FSP, ADV_IMP, ADV_INT, ADV_SPM, ADV_TDS, AGD_OPE.1, AGD_PRE.1, AGD_OPE, AGD_PRE, ALC_FLR.2, ALC_CMC.1, ALC_CMC.2, ALC_CMC.3, ALC_CMC.4, ALC_CMC.5, ALC_CMS.1, ALC_CMS.2, ALC_CMS.3, ALC_CMS.4, ALC_CMS.5, ALC_DEL.1, ALC_DVS.1, ALC_DVS.2, ALC_FLR.1, ALC_FLR.3, ALC_LCD.1, ALC_LCD.2, ALC_TAT.1, ALC_TAT.2, ALC_TAT.3, ALC_CMC, ALC_CMS, ALC_DEL, ALC_DVS, ALC_FLR, ALC_TAT, ATE_COV.1, ATE_COV.2, ATE_COV.3, ATE_DPT.1, ATE_DPT.2, ATE_DPT.3, ATE_DPT.4, ATE_FUN.1, ATE_FUN.2, ATE_IND.1, ATE_IND.2, ATE_IND.3, ATE_COV, ATE_DPT, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VAN.1, AVA_VAN.2, AVA_VAN.3, AVA_VAN.4, AVA_VAN, APE_INT.1, APE_CCL.1, APE_SPD.1, APE_OBJ.2, APE_ECD.1, APE_REQ.2, APE_OBJ.1, APE_REQ.1, ASE_INT.1, ASE_CCL.1, ASE_SPD.1, ASE_OBJ.1, ASE_OBJ.2, ASE_ECD.1, ASE_REQ.1, ASE_REQ.2, ASE_TSS.1, ASE_TSS.2, ASE_CCL, ASE_ECD, ASE_INT, ASE_OBJ, ASE_SPD, ASE_TSS
Protection profiles
BSI-CC-PP-0073-2014, BSI-CC-PP-0077-2013

Certification process
on the BSI Website [5] Evaluation Technical Report, Version 1.1, 02 April 2014, media transfer AG (confidential document) [6] BSI-CC-PP-0073-2014 Protection Profile for the Gateway of a Smart Metering System (Smart Meter

Standards
AIS 32
Technical reports
BSI 7125, BSI 2, BSI 7148

Protection profile

Extracted keywords

Symmetric Algorithms
AES
Asymmetric Algorithms
ECC, Diffie-Hellman
Schemes
MAC
Protocols
TLS
Randomness
RNG

Security level
EAL 4, EAL4, EAL 4 augmented, EAL4 augmented
Claims
OE.SM, OSP.SM
Security Assurance Requirements (SAR)
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_FLR.2, ALC_CMC.4, ALC_DEL.1, ALC_LCD.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5, ASE_CCL.1, ASE_ECD.1, ASE_OBJ.2, ASE_SPD.1
Security Functional Requirements (SFR)
FAU_ARP, FAU_GEN, FAU_SAA, FAU_SAR, FAU_STG, FAU_GEN.2, FAU_STG.2, FAU_ARP.1, FAU_SAA.1, FAU_GEN.1, FAU_SAR.1, FAU_STG.4, FAU_STG.3, FAU_STG.1, FAU_GEN.2.1, FAU_STG.2.1, FAU_STG.2.2, FAU_STG.2.3, FAU_CON.1.2, FCO_NRO, FCO_NRO.2, FCO_NRO.2.1, FCO_NRO.2.2, FCO_NRO.2.3, FCO_NRO.1, FCS_RNG, FCS_CKM, FCS_COP, FCS_CKM.4, FCS_CKM.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_IFC, FDP_ACC.2, FDP_ACF.1, FDP_IFF, FDP_RIP.2, FDP_SDI.2, FDP_ITC.1, FDP_ITC.2, FDP_ACC, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACC.1, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_IFC.2, FDP_IFC.1, FDP_IFF.1, FDP_IFF.1.3, FDP_RIP, FDP_RIP.2.1, FDP_RIP.1, FDP_SDI, FDP_SDI.2.1, FDP_SDI.2.2, FDP_SDI.1, FIA_ATD, FIA_AFL, FIA_UAU, FIA_UID, FIA_USB, FIA_ATD.1, FIA_AFL.1, FIA_UAU.2, FIA_UAU.5, FIA_UAU.6, FIA_UID.2, FIA_USB.1, FIA_UID.1, FIA_ATD.1.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_UAU.1, FIA_UAU.2.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UAU.6.1, FIA_UID.2.1, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_SMR, FMT_MOF.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA, FMT_MSA.3, FMT_MOF, FMT_MOF.1.1, FMT_SMF, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MSA.1, FPR_CON, FPR_CON.1, FPR_PSE, FPR_CON.1.2, FPR_CON.1.1, FPR_PSE.1, FPR_PSE.1.1, FPR_PSE.1.2, FPR_PSE.1.3, FPT_FLS, FPT_RPL, FPT_STM, FPT_TST, FPT_FLS.1, FPT_RPL.1, FPT_STM.1, FPT_TST.1, FPT_PHP.1, FPT_FLS.1.1, FPT_RPL.1.1, FPT_RPL.1.2, FPT_STM.1.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_PHP, FPT_PHP.1.1, FPT_PHP.1.2, FTP_ITC, FTP_ITC.1
Protection profiles
BSI-CC-PP-0073, BSI-CC-PP-0077-2013

Side-channel analysis
physical tampering, malfunction

Technical reports
BSI TR-03109-1, BSI TR-02102-2, BSI TR-03109, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03116-3, BSI TR-03109-4

References

Automated inference - use with caution

All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.

Processing updates

Feed
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile was first processed.

Raw data

{
  "_id": "6346b04de6859db3",
  "_type": "sec_certs.sample.protection_profile.ProtectionProfile",
  "dgst": "6346b04de6859db3",
  "heuristics": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.Heuristics"
  },
  "pdf_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.PdfData",
    "pp_filename": "pp0073b_pdf.pdf",
    "pp_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 4
          }
        },
        "FF": {
          "DH": {
            "Diffie-Hellman": 1
          }
        }
      },
      "cc_cert_id": {},
      "cc_claims": {
        "OE": {
          "OE.SM": 4
        },
        "OSP": {
          "OSP.SM": 5
        }
      },
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0073": 2,
          "BSI-CC-PP-0077-2013": 1
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC.1": 1,
          "ADV_IMP.1": 1
        },
        "AGD": {
          "AGD_OPE.1": 1
        },
        "ALC": {
          "ALC_CMC.4": 1,
          "ALC_DEL.1": 1,
          "ALC_FLR.2": 6,
          "ALC_LCD.1": 1
        },
        "ASE": {
          "ASE_CCL.1": 1,
          "ASE_ECD.1": 1,
          "ASE_OBJ.2": 1,
          "ASE_SPD.1": 1
        },
        "ATE": {
          "ATE_COV.2": 1,
          "ATE_FUN.1": 1
        },
        "AVA": {
          "AVA_VAN.5": 7
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 4": 5,
          "EAL 4 augmented": 2,
          "EAL4": 1,
          "EAL4 augmented": 1
        }
      },
      "cc_sfr": {
        "FAU": {
          "FAU_ARP": 7,
          "FAU_ARP.1": 1,
          "FAU_CON.1.2": 1,
          "FAU_GEN": 30,
          "FAU_GEN.1": 20,
          "FAU_GEN.2": 5,
          "FAU_GEN.2.1": 1,
          "FAU_SAA": 9,
          "FAU_SAA.1": 4,
          "FAU_SAR": 21,
          "FAU_SAR.1": 7,
          "FAU_STG": 23,
          "FAU_STG.1": 8,
          "FAU_STG.2": 8,
          "FAU_STG.2.1": 1,
          "FAU_STG.2.2": 1,
          "FAU_STG.2.3": 2,
          "FAU_STG.3": 3,
          "FAU_STG.4": 3
        },
        "FCO": {
          "FCO_NRO": 3,
          "FCO_NRO.1": 1,
          "FCO_NRO.2": 6,
          "FCO_NRO.2.1": 1,
          "FCO_NRO.2.2": 1,
          "FCO_NRO.2.3": 1
        },
        "FCS": {
          "FCS_CKM": 39,
          "FCS_CKM.1": 16,
          "FCS_CKM.2": 6,
          "FCS_CKM.4": 29,
          "FCS_CKM.4.1": 1,
          "FCS_COP": 45,
          "FCS_COP.1": 11,
          "FCS_RNG": 1
        },
        "FDP": {
          "FDP_ACC": 2,
          "FDP_ACC.1": 9,
          "FDP_ACC.2": 8,
          "FDP_ACC.2.1": 1,
          "FDP_ACC.2.2": 1,
          "FDP_ACF.1": 7,
          "FDP_ACF.1.1": 1,
          "FDP_ACF.1.2": 1,
          "FDP_ACF.1.3": 1,
          "FDP_ACF.1.4": 1,
          "FDP_IFC": 23,
          "FDP_IFC.1": 12,
          "FDP_IFC.2": 4,
          "FDP_IFF": 18,
          "FDP_IFF.1": 20,
          "FDP_IFF.1.3": 1,
          "FDP_ITC.1": 12,
          "FDP_ITC.2": 12,
          "FDP_RIP": 2,
          "FDP_RIP.1": 1,
          "FDP_RIP.2": 6,
          "FDP_RIP.2.1": 1,
          "FDP_SDI": 2,
          "FDP_SDI.1": 1,
          "FDP_SDI.2": 5,
          "FDP_SDI.2.1": 1,
          "FDP_SDI.2.2": 1
        },
        "FIA": {
          "FIA_AFL": 3,
          "FIA_AFL.1": 5,
          "FIA_AFL.1.1": 1,
          "FIA_AFL.1.2": 1,
          "FIA_ATD": 3,
          "FIA_ATD.1": 10,
          "FIA_ATD.1.1": 1,
          "FIA_UAU": 5,
          "FIA_UAU.1": 2,
          "FIA_UAU.2": 5,
          "FIA_UAU.2.1": 1,
          "FIA_UAU.5": 4,
          "FIA_UAU.5.1": 1,
          "FIA_UAU.5.2": 1,
          "FIA_UAU.6": 5,
          "FIA_UAU.6.1": 1,
          "FIA_UID": 3,
          "FIA_UID.1": 8,
          "FIA_UID.2": 9,
          "FIA_UID.2.1": 1,
          "FIA_USB": 3,
          "FIA_USB.1": 5,
          "FIA_USB.1.1": 1,
          "FIA_USB.1.2": 1,
          "FIA_USB.1.3": 1
        },
        "FMT": {
          "FMT_MOF": 1,
          "FMT_MOF.1": 5,
          "FMT_MOF.1.1": 1,
          "FMT_MSA": 44,
          "FMT_MSA.1": 9,
          "FMT_MSA.3": 12,
          "FMT_SMF": 2,
          "FMT_SMF.1": 16,
          "FMT_SMF.1.1": 1,
          "FMT_SMR": 3,
          "FMT_SMR.1": 25,
          "FMT_SMR.1.1": 1,
          "FMT_SMR.1.2": 1
        },
        "FPR": {
          "FPR_CON": 6,
          "FPR_CON.1": 8,
          "FPR_CON.1.1": 2,
          "FPR_CON.1.2": 5,
          "FPR_PSE": 2,
          "FPR_PSE.1": 6,
          "FPR_PSE.1.1": 1,
          "FPR_PSE.1.2": 1,
          "FPR_PSE.1.3": 1
        },
        "FPT": {
          "FPT_FLS": 3,
          "FPT_FLS.1": 7,
          "FPT_FLS.1.1": 1,
          "FPT_PHP": 1,
          "FPT_PHP.1": 6,
          "FPT_PHP.1.1": 1,
          "FPT_PHP.1.2": 1,
          "FPT_RPL": 3,
          "FPT_RPL.1": 5,
          "FPT_RPL.1.1": 1,
          "FPT_RPL.1.2": 1,
          "FPT_STM": 3,
          "FPT_STM.1": 16,
          "FPT_STM.1.1": 1,
          "FPT_TST": 3,
          "FPT_TST.1": 7,
          "FPT_TST.1.1": 1,
          "FPT_TST.1.2": 1,
          "FPT_TST.1.3": 1
        },
        "FTP": {
          "FTP_ITC": 20,
          "FTP_ITC.1": 9
        }
      },
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {
        "TLS": {
          "TLS": {
            "TLS": 24
          }
        }
      },
      "crypto_scheme": {
        "MAC": {
          "MAC": 7
        }
      },
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "RNG": {
          "RNG": 1
        }
      },
      "side_channel_analysis": {
        "FI": {
          "malfunction": 2,
          "physical tampering": 3
        }
      },
      "standard_id": {
        "BSI": {
          "AIS20": 2,
          "AIS31": 2
        },
        "RFC": {
          "RFC 5114": 1,
          "RFC 5639": 1,
          "RFC5114": 1,
          "RFC5246": 1,
          "RFC5639": 1
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 2
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI TR-02102-2": 1,
          "BSI TR-03109": 1,
          "BSI TR-03109-1": 9,
          "BSI TR-03109-2": 1,
          "BSI TR-03109-3": 1,
          "BSI TR-03109-4": 1,
          "BSI TR-03116-3": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "pp_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik (BSI)",
      "/CreationDate": "D:20140404090805+02\u002700\u0027",
      "/Creator": "Microsoft\u00ae Word 2010",
      "/Keywords": "Smart Meter System,Gateway,Common Criteria,Smart Meter Gateway PP",
      "/ModDate": "D:20140404112722+02\u002700\u0027",
      "/Producer": "Microsoft\u00ae Word 2010",
      "/Subject": "Schutzprofil f\u00fcr die Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen",
      "/Title": "Protection Profile for the Gateway of a Smart Metering System (Smart Meter Gateway PP)",
      "pdf_file_size_bytes": 2431154,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 93
    },
    "report_filename": "pp0073a_pdf.pdf",
    "report_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {},
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0073-2014": 15,
          "BSI-CC-PP-0077-2013": 1
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC": 1,
          "ADV_ARC.1": 1,
          "ADV_FSP": 1,
          "ADV_FSP.1": 1,
          "ADV_FSP.2": 1,
          "ADV_FSP.3": 1,
          "ADV_FSP.4": 1,
          "ADV_FSP.5": 1,
          "ADV_FSP.6": 1,
          "ADV_IMP": 1,
          "ADV_IMP.1": 1,
          "ADV_IMP.2": 1,
          "ADV_INT": 1,
          "ADV_INT.1": 1,
          "ADV_INT.2": 1,
          "ADV_INT.3": 1,
          "ADV_SPM": 1,
          "ADV_SPM.1": 1,
          "ADV_TDS": 1,
          "ADV_TDS.1": 1,
          "ADV_TDS.2": 1,
          "ADV_TDS.3": 1,
          "ADV_TDS.4": 1,
          "ADV_TDS.5": 1,
          "ADV_TDS.6": 1
        },
        "AGD": {
          "AGD_OPE": 1,
          "AGD_OPE.1": 1,
          "AGD_PRE": 1,
          "AGD_PRE.1": 1
        },
        "ALC": {
          "ALC_CMC": 1,
          "ALC_CMC.1": 1,
          "ALC_CMC.2": 1,
          "ALC_CMC.3": 1,
          "ALC_CMC.4": 1,
          "ALC_CMC.5": 1,
          "ALC_CMS": 1,
          "ALC_CMS.1": 1,
          "ALC_CMS.2": 1,
          "ALC_CMS.3": 1,
          "ALC_CMS.4": 1,
          "ALC_CMS.5": 1,
          "ALC_DEL": 1,
          "ALC_DEL.1": 1,
          "ALC_DVS": 1,
          "ALC_DVS.1": 1,
          "ALC_DVS.2": 1,
          "ALC_FLR": 1,
          "ALC_FLR.1": 1,
          "ALC_FLR.2": 3,
          "ALC_FLR.3": 1,
          "ALC_LCD.1": 1,
          "ALC_LCD.2": 1,
          "ALC_TAT": 1,
          "ALC_TAT.1": 1,
          "ALC_TAT.2": 1,
          "ALC_TAT.3": 1
        },
        "APE": {
          "APE_CCL.1": 2,
          "APE_ECD.1": 2,
          "APE_INT.1": 2,
          "APE_OBJ.1": 1,
          "APE_OBJ.2": 2,
          "APE_REQ.1": 1,
          "APE_REQ.2": 2,
          "APE_SPD.1": 2
        },
        "ASE": {
          "ASE_CCL": 1,
          "ASE_CCL.1": 1,
          "ASE_ECD": 1,
          "ASE_ECD.1": 1,
          "ASE_INT": 1,
          "ASE_INT.1": 1,
          "ASE_OBJ": 1,
          "ASE_OBJ.1": 1,
          "ASE_OBJ.2": 1,
          "ASE_REQ.1": 1,
          "ASE_REQ.2": 1,
          "ASE_SPD": 1,
          "ASE_SPD.1": 1,
          "ASE_TSS": 1,
          "ASE_TSS.1": 1,
          "ASE_TSS.2": 1
        },
        "ATE": {
          "ATE_COV": 1,
          "ATE_COV.1": 1,
          "ATE_COV.2": 1,
          "ATE_COV.3": 1,
          "ATE_DPT": 1,
          "ATE_DPT.1": 1,
          "ATE_DPT.2": 1,
          "ATE_DPT.3": 1,
          "ATE_DPT.4": 1,
          "ATE_FUN": 1,
          "ATE_FUN.1": 1,
          "ATE_FUN.2": 1,
          "ATE_IND": 1,
          "ATE_IND.1": 1,
          "ATE_IND.2": 1,
          "ATE_IND.3": 1
        },
        "AVA": {
          "AVA_VAN": 2,
          "AVA_VAN.1": 1,
          "AVA_VAN.2": 1,
          "AVA_VAN.3": 1,
          "AVA_VAN.4": 1,
          "AVA_VAN.5": 3
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 4": 3,
          "EAL 4 augmented": 2,
          "EAL1": 7,
          "EAL2": 3,
          "EAL3": 4,
          "EAL4": 6,
          "EAL5": 6,
          "EAL6": 3,
          "EAL7": 4
        },
        "ITSEC": {
          "ITSEC Evaluation": 1
        }
      },
      "cc_sfr": {},
      "certification_process": {
        "ConfidentialDocument": {
          "on the BSI Website [5] Evaluation Technical Report, Version 1.1, 02 April 2014, media transfer AG (confidential document) [6] BSI-CC-PP-0073-2014 Protection Profile for the Gateway of a Smart Metering System (Smart Meter": 1
        }
      },
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {},
      "standard_id": {
        "BSI": {
          "AIS 32": 1
        }
      },
      "symmetric_crypto": {},
      "technical_report_id": {
        "BSI": {
          "BSI 2": 1,
          "BSI 7125": 2,
          "BSI 7148": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "report_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
      "/CreationDate": "D:20140404103436+02\u002700\u0027",
      "/Creator": "Writer",
      "/Keywords": "\"Common Criteria, Certification, Zertifizierung, Protection Profile, Schutzprofil, Smart Meter Gateway, SMGW\"",
      "/ModDate": "D:20140404104004+02\u002700\u0027",
      "/Producer": "LibreOffice 3.6",
      "/Subject": "Protection Profile, Smart Meter Gateway",
      "/Title": "Certification Report BSI-CC-PP-0073-2014",
      "pdf_file_size_bytes": 754839,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": [
          "https://www.bsi.bund.de/"
        ]
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 28
    }
  },
  "scheme_metadata": null,
  "state": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.InternalState",
    "pp": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": "a14d2a39e04c0403186ec8f0ac4e7680a3f1d797f9f6da92a1377afbedfd3f25",
      "txt_hash": "3e079ef959e651b2765d50198f4bdf45164dcb5ecd8bf2261f796f0ba1ece25c"
    },
    "report": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": "ffc19914b431ac3732161ee0a507155acbf81ca50847cc56d0c063e33f49598f",
      "txt_hash": "8e2dc293360f9a19e62de904ee6c02f93a3b146d77050287530d4470121ff742"
    }
  },
  "web_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.WebData",
    "category": "Network and Network-Related Devices and Systems",
    "is_collaborative": false,
    "maintenances": [],
    "name": "Protection Profile for the Gateway of a Smart Metering System",
    "not_valid_after": null,
    "not_valid_before": "2014-04-04",
    "pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073b_pdf.pdf",
    "report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073a_pdf.pdf",
    "scheme": "DE",
    "security_level": {
      "_type": "Set",
      "elements": [
        "EAL4+",
        "AVA_VAN.5",
        "ALC_FLR.2"
      ]
    },
    "status": "active",
    "version": "Version 1.3"
  }
}