This page was not yet optimized for use on mobile
devices.
Protection Profile for the Security Module of a Smart Metering System
Web information
| Status | active |
|---|---|
| Valid from | 20.12.2013 |
| Scheme | 🇩🇪 DE |
| Category | ICs, Smart Cards and Smart Card-Related Devices and Systems |
| Security level | EAL4+, AVA_VAN.5 |
Certification report
Extracted keywords
Asymmetric Algorithms
DHProtocols
PACESecurity level
EAL 4, EAL1, EAL4, EAL3, EAL5, EAL7, EAL2, EAL6, EAL 4 augmented, ITSEC EvaluationSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.1, ADV_FSP.2, ADV_FSP.3, ADV_FSP.4, ADV_FSP.5, ADV_FSP.6, ADV_IMP.1, ADV_IMP.2, ADV_INT.1, ADV_INT.2, ADV_INT.3, ADV_SPM.1, ADV_TDS.1, ADV_TDS.2, ADV_TDS.3, ADV_TDS.4, ADV_TDS.5, ADV_TDS.6, ADV_ARC, ADV_FSP, ADV_IMP, ADV_INT, ADV_SPM, ADV_TDS, AGD_OPE.1, AGD_PRE.1, AGD_OPE, AGD_PRE, ALC_CMC.1, ALC_CMC.2, ALC_CMC.3, ALC_CMC.4, ALC_CMC.5, ALC_CMS.1, ALC_CMS.2, ALC_CMS.3, ALC_CMS.4, ALC_CMS.5, ALC_DEL.1, ALC_DVS.1, ALC_DVS.2, ALC_FLR.1, ALC_FLR.2, ALC_FLR.3, ALC_LCD.1, ALC_LCD.2, ALC_TAT.1, ALC_TAT.2, ALC_TAT.3, ALC_CMC, ALC_CMS, ALC_DEL, ALC_DVS, ALC_FLR, ALC_TAT, ATE_COV.1, ATE_COV.2, ATE_COV.3, ATE_DPT.1, ATE_DPT.2, ATE_DPT.3, ATE_DPT.4, ATE_FUN.1, ATE_FUN.2, ATE_IND.1, ATE_IND.2, ATE_IND.3, ATE_COV, ATE_DPT, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VAN.1, AVA_VAN.2, AVA_VAN.3, AVA_VAN.4, AVA_VAN, APE_INT.1, APE_CCL.1, APE_SPD.1, APE_OBJ.2, APE_ECD.1, APE_REQ.2, APE_OBJ.1, APE_REQ.1, ASE_INT.1, ASE_CCL.1, ASE_SPD.1, ASE_OBJ.1, ASE_OBJ.2, ASE_ECD.1, ASE_REQ.1, ASE_REQ.2, ASE_TSS.1, ASE_TSS.2, ASE_CCL, ASE_ECD, ASE_INT, ASE_OBJ, ASE_SPD, ASE_TSSProtection profiles
BSI-CC-PP-0077-2013, BSI-CC-PP-0077Evaluation facilities
TÜV Informationstechnik, TUV InformationstechnikSide-channel analysis
physical tampering, malfunctionCertification process
Website [5] Evaluation Technical Report, Version 1, Date: 2013-11-13, TUV Informationstechnik GmbH(confidential document) [6] Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PPStandards
AIS 32Technical reports
BSI 7125, BSI 2, BSI 7148File metadata
| Title | Certification Report BSI-CC-PP-0077-2013 |
|---|---|
| Subject | Schutzprofil, smart meter security module |
| Keywords | "Common Criteria, Certification, Zertifizierung, Protection Profile, Schutzprofil, smart meter security module" |
| Author | Bundesamt für Sicherheit in der Informationstechnik |
| Creation date | D:20140130101528+01'00' |
| Modification date | D:20140130101916+01'00' |
| Pages | 28 |
| Creator | Writer |
| Producer | LibreOffice 3.6 |
Protection Profile
Extracted keywords
Symmetric Algorithms
AESAsymmetric Algorithms
ECDH, ECDSA, ECC, DH, Diffie-HellmanSchemes
MAC, Key AgreementProtocols
TLS, PACERandomness
RNGBlock cipher modes
CBCSecurity level
EAL 4, EAL 4 augmentedClaims
O.PACE, OE.PACE, OSP.SMSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE.1, AGD_PRE.1, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1Security Functional Requirements (SFR)
FCS_RNG, FCS_RNG.1, FCS_RNG.1.1, FCS_RNG.1.2, FCS_CKM, FCS_CKM.4, FCS_COP, FCS_CKM.2, FCS_COP.1, FCS_CKM.1, FCS_CKM.4.1, FDP_ACF, FDP_ACC.2, FDP_ACF.1, FDP_SDI.2, FDP_RIP.1, FDP_ETC.1, FDP_ITC.1, FDP_UCT.1, FDP_UIT.1, FDP_ITC.2, FDP_ACC, FDP_ACC.1, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_SDI, FDP_SDI.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_RIP, FDP_RIP.1.1, FDP_ETC, FDP_IFC.1, FDP_ETC.1.1, FDP_ETC.1.2, FDP_ITC, FDP_ITC.1.1, FDP_ITC.1.2, FDP_ITC.1.3, FDP_UCT, FDP_UCT.1.1, FDP_UIT, FDP_UIT.1.1, FDP_UIT.1.2, FIA_ATD.1, FIA_UAU, FIA_UAU.4, FIA_UAU.5, FIA_UID.1, FIA_USB.1, FIA_ATD, FIA_ATD.1.1, FIA_UAU.1, FIA_UAU.4.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UID, FIA_UID.1.1, FIA_UID.1.2, FIA_USB, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_LIM, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA.3, FMT_SMF, FMT_SMF.1.1, FMT_SMR, FMT_SMR.1.1, FMT_SMR.1.2, FPT_EMS, FPT_EMS.1, FPT_EMS.1.1, FPT_EMS.1.2, FPT_FLS.1, FPT_PHP.3, FPT_TST.1, FPT_FLS, FPT_FLS.1.1, FPT_PHP, FPT_PHP.3.1, FPT_TST, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FTP_ITC.1, FTP_TRP.1, FTP_ITC, FTP_ITC.1.1, FTP_ITC.1.2, FTP_ITC.1.3, FTP_ICT.1Protection profiles
BSI-CC-PP-0077Side-channel analysis
physical probing, side channels, side channel, SPA, DPA, timing attacks, Physical tampering, physical tampering, Malfunction, malfunction, DFA, fault injectionCertification process
out of scope, entities. As these external entities do not directly interact with the TOE, these entities are out of scope for this PP. During its pre-operational phases the TOE interacts with the Integrator and theStandards
FIPS 197, RFC 4493, RFC 44993, ISO/IEC 10116, X.509, CCMB-2012-09-001, CCMB-2012-09-002, CCMB-2012-09-003, CCMB-2012-09-004Technical reports
BSI TR-03109, BSI TR-03109-1, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03109-4, BSI TR-03111, BSI TR-03110-1, BSI TR-03110-2, BSI TR-03110-3, BSI TR-03116-3File metadata
| Title | Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) |
|---|---|
| Subject | Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen |
| Keywords | "Smart Meter System, Security Module, Common Criteria" |
| Author | Bundesamt für Sicherheit in der Informationstechnik |
| Creation date | D:20131216135458+01'00' |
| Modification date | D:20140130145229+01'00' |
| Pages | 87 |
| Creator | Writer |
| Producer | LibreOffice 3.6 |
References
Automated inference - use with caution
All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. For details on our data sources and inference methods, see our methodology. If you believe any information here is inaccurate or harmful, please submit feedback.Updates Feed
-
The protection profile data changed.
-
The protection profile data changed.
-
The protection profile data changed.
-
The protection profile was first processed.
Raw data
{
"_id": "c8d6c0233df5d5fb",
"_type": "sec_certs.sample.protection_profile.ProtectionProfile",
"dgst": "c8d6c0233df5d5fb",
"heuristics": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.Heuristics"
},
"pdf_data": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.PdfData",
"pp_filename": "pp0077b_pdf.pdf",
"pp_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 8
},
"ECDH": {
"ECDH": 1
},
"ECDSA": {
"ECDSA": 21
}
},
"FF": {
"DH": {
"DH": 19,
"Diffie-Hellman": 2
}
}
},
"cc_cert_id": {},
"cc_claims": {
"O": {
"O.PACE": 9
},
"OE": {
"OE.PACE": 5
},
"OSP": {
"OSP.SM": 1
}
},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077": 2
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_FSP.4": 1,
"ADV_IMP.1": 1,
"ADV_TDS.3": 1
},
"AGD": {
"AGD_OPE.1": 1,
"AGD_PRE.1": 1
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS.1": 1,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_ECD.1": 1,
"ASE_INT.1": 1,
"ASE_OBJ.2": 1,
"ASE_REQ.2": 1,
"ASE_SPD.1": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_DPT.1": 1,
"ATE_FUN.1": 1,
"ATE_IND.2": 1
},
"AVA": {
"AVA_VAN.5": 8
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 8,
"EAL 4 augmented": 3
}
},
"cc_sfr": {
"FCS": {
"FCS_CKM": 58,
"FCS_CKM.1": 18,
"FCS_CKM.2": 12,
"FCS_CKM.4": 39,
"FCS_CKM.4.1": 1,
"FCS_COP": 49,
"FCS_COP.1": 18,
"FCS_RNG": 7,
"FCS_RNG.1": 14,
"FCS_RNG.1.1": 2,
"FCS_RNG.1.2": 3
},
"FDP": {
"FDP_ACC": 1,
"FDP_ACC.1": 11,
"FDP_ACC.2": 14,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 3,
"FDP_ACF.1": 8,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_ETC": 1,
"FDP_ETC.1": 6,
"FDP_ETC.1.1": 1,
"FDP_ETC.1.2": 1,
"FDP_IFC.1": 8,
"FDP_ITC": 2,
"FDP_ITC.1": 23,
"FDP_ITC.1.1": 1,
"FDP_ITC.1.2": 1,
"FDP_ITC.1.3": 1,
"FDP_ITC.2": 14,
"FDP_RIP": 1,
"FDP_RIP.1": 13,
"FDP_RIP.1.1": 1,
"FDP_SDI": 1,
"FDP_SDI.1": 1,
"FDP_SDI.2": 11,
"FDP_SDI.2.1": 2,
"FDP_SDI.2.2": 1,
"FDP_UCT": 1,
"FDP_UCT.1": 7,
"FDP_UCT.1.1": 1,
"FDP_UIT": 1,
"FDP_UIT.1": 6,
"FDP_UIT.1.1": 1,
"FDP_UIT.1.2": 1
},
"FIA": {
"FIA_ATD": 1,
"FIA_ATD.1": 8,
"FIA_ATD.1.1": 1,
"FIA_UAU": 15,
"FIA_UAU.1": 4,
"FIA_UAU.4": 5,
"FIA_UAU.4.1": 1,
"FIA_UAU.5": 6,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UID": 1,
"FIA_UID.1": 15,
"FIA_UID.1.1": 1,
"FIA_UID.1.2": 1,
"FIA_USB": 1,
"FIA_USB.1": 6,
"FIA_USB.1.1": 1,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_LIM": 6,
"FMT_LIM.1": 23,
"FMT_LIM.1.1": 2,
"FMT_LIM.2": 19,
"FMT_LIM.2.1": 2,
"FMT_MSA.3": 6,
"FMT_SMF": 1,
"FMT_SMF.1": 7,
"FMT_SMF.1.1": 1,
"FMT_SMR": 1,
"FMT_SMR.1": 6,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPT": {
"FPT_EMS": 6,
"FPT_EMS.1": 19,
"FPT_EMS.1.1": 3,
"FPT_EMS.1.2": 3,
"FPT_FLS": 1,
"FPT_FLS.1": 15,
"FPT_FLS.1.1": 1,
"FPT_PHP": 1,
"FPT_PHP.3": 14,
"FPT_PHP.3.1": 1,
"FPT_TST": 1,
"FPT_TST.1": 15,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ICT.1": 4,
"FTP_ITC": 1,
"FTP_ITC.1": 10,
"FTP_ITC.1.1": 1,
"FTP_ITC.1.2": 1,
"FTP_ITC.1.3": 1,
"FTP_TRP.1": 4
}
},
"certification_process": {
"OutOfScope": {
"entities. As these external entities do not directly interact with the TOE, these entities are out of scope for this PP. During its pre-operational phases the TOE interacts with the Integrator and the": 1,
"out of scope": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 4
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 60
},
"TLS": {
"TLS": {
"TLS": 20
}
}
},
"crypto_scheme": {
"KA": {
"Key Agreement": 11
},
"MAC": {
"MAC": 1
}
},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RNG": 1
}
},
"side_channel_analysis": {
"FI": {
"DFA": 1,
"Malfunction": 13,
"Physical tampering": 1,
"fault injection": 1,
"malfunction": 3,
"physical tampering": 5
},
"SCA": {
"DPA": 3,
"SPA": 3,
"physical probing": 3,
"side channel": 3,
"side channels": 1,
"timing attacks": 2
}
},
"standard_id": {
"CC": {
"CCMB-2012-09-001": 2,
"CCMB-2012-09-002": 2,
"CCMB-2012-09-003": 2,
"CCMB-2012-09-004": 2
},
"FIPS": {
"FIPS 197": 1
},
"ISO": {
"ISO/IEC 10116": 2
},
"RFC": {
"RFC 4493": 2,
"RFC 44993": 1
},
"X509": {
"X.509": 2
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 8
}
}
},
"technical_report_id": {
"BSI": {
"BSI TR-03109": 1,
"BSI TR-03109-1": 1,
"BSI TR-03109-2": 1,
"BSI TR-03109-3": 1,
"BSI TR-03109-4": 1,
"BSI TR-03110-1": 1,
"BSI TR-03110-2": 1,
"BSI TR-03110-3": 1,
"BSI TR-03111": 1,
"BSI TR-03116-3": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"pp_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20131216135458+01\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Smart Meter System, Security Module, Common Criteria\"",
"/ModDate": "D:20140130145229+01\u002700\u0027",
"/Producer": "LibreOffice 3.6",
"/Subject": "Schutzprofil f\u00fcr das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen",
"/Title": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP)",
"pdf_file_size_bytes": 3630172,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 87
},
"report_filename": "pp0077a_pdf.pdf",
"report_keywords": {
"asymmetric_crypto": {
"FF": {
"DH": {
"DH": 2
}
}
},
"cc_cert_id": {},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077": 1,
"BSI-CC-PP-0077-2013": 14
}
},
"cc_sar": {
"ADV": {
"ADV_ARC": 1,
"ADV_ARC.1": 1,
"ADV_FSP": 1,
"ADV_FSP.1": 1,
"ADV_FSP.2": 1,
"ADV_FSP.3": 1,
"ADV_FSP.4": 1,
"ADV_FSP.5": 1,
"ADV_FSP.6": 1,
"ADV_IMP": 1,
"ADV_IMP.1": 1,
"ADV_IMP.2": 1,
"ADV_INT": 1,
"ADV_INT.1": 1,
"ADV_INT.2": 1,
"ADV_INT.3": 1,
"ADV_SPM": 1,
"ADV_SPM.1": 1,
"ADV_TDS": 1,
"ADV_TDS.1": 1,
"ADV_TDS.2": 1,
"ADV_TDS.3": 1,
"ADV_TDS.4": 1,
"ADV_TDS.5": 1,
"ADV_TDS.6": 1
},
"AGD": {
"AGD_OPE": 1,
"AGD_OPE.1": 1,
"AGD_PRE": 1,
"AGD_PRE.1": 1
},
"ALC": {
"ALC_CMC": 1,
"ALC_CMC.1": 1,
"ALC_CMC.2": 1,
"ALC_CMC.3": 1,
"ALC_CMC.4": 1,
"ALC_CMC.5": 1,
"ALC_CMS": 1,
"ALC_CMS.1": 1,
"ALC_CMS.2": 1,
"ALC_CMS.3": 1,
"ALC_CMS.4": 1,
"ALC_CMS.5": 1,
"ALC_DEL": 1,
"ALC_DEL.1": 1,
"ALC_DVS": 1,
"ALC_DVS.1": 1,
"ALC_DVS.2": 1,
"ALC_FLR": 1,
"ALC_FLR.1": 1,
"ALC_FLR.2": 1,
"ALC_FLR.3": 1,
"ALC_LCD.1": 1,
"ALC_LCD.2": 1,
"ALC_TAT": 1,
"ALC_TAT.1": 1,
"ALC_TAT.2": 1,
"ALC_TAT.3": 1
},
"APE": {
"APE_CCL.1": 2,
"APE_ECD.1": 2,
"APE_INT.1": 2,
"APE_OBJ.1": 1,
"APE_OBJ.2": 2,
"APE_REQ.1": 1,
"APE_REQ.2": 2,
"APE_SPD.1": 2
},
"ASE": {
"ASE_CCL": 1,
"ASE_CCL.1": 1,
"ASE_ECD": 1,
"ASE_ECD.1": 1,
"ASE_INT": 1,
"ASE_INT.1": 1,
"ASE_OBJ": 1,
"ASE_OBJ.1": 1,
"ASE_OBJ.2": 1,
"ASE_REQ.1": 1,
"ASE_REQ.2": 1,
"ASE_SPD": 1,
"ASE_SPD.1": 1,
"ASE_TSS": 1,
"ASE_TSS.1": 1,
"ASE_TSS.2": 1
},
"ATE": {
"ATE_COV": 1,
"ATE_COV.1": 1,
"ATE_COV.2": 1,
"ATE_COV.3": 1,
"ATE_DPT": 1,
"ATE_DPT.1": 1,
"ATE_DPT.2": 1,
"ATE_DPT.3": 1,
"ATE_DPT.4": 1,
"ATE_FUN": 1,
"ATE_FUN.1": 1,
"ATE_FUN.2": 1,
"ATE_IND": 1,
"ATE_IND.1": 1,
"ATE_IND.2": 1,
"ATE_IND.3": 1
},
"AVA": {
"AVA_VAN": 2,
"AVA_VAN.1": 1,
"AVA_VAN.2": 1,
"AVA_VAN.3": 1,
"AVA_VAN.4": 1,
"AVA_VAN.5": 3
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 3,
"EAL 4 augmented": 2,
"EAL1": 7,
"EAL2": 3,
"EAL3": 4,
"EAL4": 6,
"EAL5": 6,
"EAL6": 3,
"EAL7": 4
},
"ITSEC": {
"ITSEC Evaluation": 1
}
},
"cc_sfr": {},
"certification_process": {
"ConfidentialDocument": {
"Website [5] Evaluation Technical Report, Version 1, Date: 2013-11-13, TUV Informationstechnik GmbH(confidential document) [6] Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP": 1
}
},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 2
}
},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"TUV": {
"TUV Informationstechnik": 1,
"T\u00dcV Informationstechnik": 2
}
},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {
"FI": {
"malfunction": 1,
"physical tampering": 1
}
},
"standard_id": {
"BSI": {
"AIS 32": 1
}
},
"symmetric_crypto": {},
"technical_report_id": {
"BSI": {
"BSI 2": 1,
"BSI 7125": 2,
"BSI 7148": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20140130101528+01\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Protection Profile, Schutzprofil, smart meter security module\"",
"/ModDate": "D:20140130101916+01\u002700\u0027",
"/Producer": "LibreOffice 3.6",
"/Subject": "Schutzprofil, smart meter security module",
"/Title": "Certification Report BSI-CC-PP-0077-2013",
"pdf_file_size_bytes": 806474,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"https://www.bsi.bund.de/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 28
}
},
"state": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.InternalState",
"pp": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"pdf_hash": "7f79cdd9ffe127bf0b516e2d53a777fe59b3ab1d2b27d42528c66287f8fe0a6e",
"txt_hash": "2537df18cb070466d295cfb40d018dd09e000287d0a758259288254be13197ec"
},
"report": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"pdf_hash": "0d2c1264e8aaf5b909b690c1a042de3c8a9548e3d15e3027c347ea892ef7d56a",
"txt_hash": "2d0fa7ab8c3568bb659ae748d2ef558526833659ab089d9111d05e892c394526"
}
},
"web_data": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.WebData",
"category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
"is_collaborative": false,
"maintenances": [],
"name": "Protection Profile for the Security Module of a Smart Metering System",
"not_valid_after": null,
"not_valid_before": "2013-12-20",
"pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0077b_pdf.pdf",
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0077a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"EAL4+",
"AVA_VAN.5"
]
},
"status": "active",
"version": "Version 1.02"
}
}