Common Criteria Protection Profile Mobile Card Terminal for the German Healthcare System (MobCT)

Profile details

Status archived
Valid from 19.01.2015
Valid until 19.01.2025
Scheme ๐Ÿ‡ฉ๐Ÿ‡ช DE
Category ICs, Smart Cards and Smart Card-Related Devices and Systems
Security level ADV_IMP.1, EAL3+, ALC_TAT.1, ADV_FSP.4, AVA_VAN.5, ADV_TDS.3

Certification report

Extracted keywords

Symmetric Algorithms
AES

Security level
EAL 1, EAL 4, EAL 2, EAL1, EAL3, EAL5, EAL7, EAL2, EAL4, EAL6, ITSEC Evaluation
Security Assurance Requirements (SAR)
ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, ADV_ARC.1, ADV_FSP.1, ADV_FSP.2, ADV_FSP.3, ADV_FSP.5, ADV_FSP.6, ADV_IMP.2, ADV_INT.1, ADV_INT.2, ADV_INT.3, ADV_SPM.1, ADV_TDS.1, ADV_TDS.2, ADV_TDS.4, ADV_TDS.5, ADV_TDS.6, ADV_ARC, ADV_FSP, ADV_IMP, ADV_INT, ADV_SPM, ADV_TDS, AGD_OPE.1, AGD_PRE.1, AGD_OPE, AGD_PRE, ALC_TAT.1, ALC_FLR, ALC_CMC.1, ALC_CMC.2, ALC_CMC.3, ALC_CMC.4, ALC_CMC.5, ALC_CMS.1, ALC_CMS.2, ALC_CMS.3, ALC_CMS.4, ALC_CMS.5, ALC_DEL.1, ALC_DVS.1, ALC_DVS.2, ALC_FLR.1, ALC_FLR.2, ALC_FLR.3, ALC_LCD.1, ALC_LCD.2, ALC_TAT.2, ALC_TAT.3, ALC_CMC, ALC_CMS, ALC_DEL, ALC_DVS, ALC_TAT, ATE_COV.1, ATE_COV.2, ATE_COV.3, ATE_DPT.1, ATE_DPT.2, ATE_DPT.3, ATE_DPT.4, ATE_FUN.1, ATE_FUN.2, ATE_IND.1, ATE_IND.2, ATE_IND.3, ATE_COV, ATE_DPT, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VAN.1, AVA_VAN.2, AVA_VAN.3, AVA_VAN.4, AVA_VAN, APE_INT.1, APE_CCL.1, APE_SPD.1, APE_OBJ.2, APE_ECD.1, APE_REQ.2, APE_OBJ.1, APE_REQ.1, ASE_INT.1, ASE_CCL.1, ASE_SPD.1, ASE_OBJ.1, ASE_OBJ.2, ASE_ECD.1, ASE_REQ.1, ASE_REQ.2, ASE_TSS.1, ASE_TSS.2, ASE_CCL, ASE_ECD, ASE_INT, ASE_OBJ, ASE_SPD, ASE_TSS
Protection profiles
BSI-CC-PP-0052-2015, BSI-CC-PP-0052

Standards
AIS 14, AIS 32
Technical reports
BSI 7125, BSI 2, BSI 7148

Protection profile

Extracted keywords

Symmetric Algorithms
AES, HPC

Security level
EAL 3, EAL 3 augmented
Claims
O.PIN, O.RESIDUAL, O.SELFTESTS, O.PROTECTION, O.AUTH_STATE, O.MANAGEMENT, O.LOG_CARDS, O.LOG_DATA, O.TRANSFER, O.DMS_CONNECT, O.TIME, O.SEALING, O.DMS_CONNECTION, T.MAN_HW, T.DATA, T.ACCESS, T.AUTH_STATE, T.ADMIN_PIN, T.FIRMWARE, A.MEDIC, A.ADMIN, A.CARDS, A.ENVIRONMENT, A.DMS, A.PHYSICAL, OE.PHYSICAL, OE.MEDIC, OE.ADMIN, OE.CARDS, OE.DMS, OE.ENVIRON, OE.DEVELOPER, OE.ENVIRONMENT, OSP.LOG_CARDS, OSP.LOG_DATA, OSP.TRANSFER, OSP.DMS_CONNECTION, OSP.TIME, OSP.SEALING, OSP.SELFTESTS, OSP.DMS_CONNECT, OSP.EMERGENCY_D, OSP.EMERGENCY_DATA
Security Assurance Requirements (SAR)
ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, ADV_ARC.1, AGD_OPE.1, AGD_PRE.1, ALC_TAT.1, ALC_CMC.3, ALC_CMS.3, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5
Security Functional Requirements (SFR)
FCS_CKM.1, FCS_CKM.4, FCS_COP, FCS_CKM.1.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_SVR, FDP_SVR.1.1, FDP_SVR.1, FDP_SVR.1.2, FDP_SVR.1.3, FDP_ACC.1, FDP_ACF.1, FDP_IFC, FDP_IFF, FDP_ITC.1, FDP_RIP, FDP_SDI.2, FDP_ITC.2, FDP_ACC.1.1, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_IFC.1, FDP_IFF.1, FDP_ITC.1.1, FDP_ITC.1.2, FDP_ITC.1.3, FDP_RIP.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_SDI.1, FIA_AFL.1, FIA_SOS.1, FIA_UAU.1, FIA_UAU.5, FIA_UAU.7, FIA_UID.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_SOS.1.1, FIA_UAU.7.1, FIA_UAU.1.1, FIA_UAU.1.2, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UID.1.1, FIA_UID.1.2, FMT_MSA.1, FMT_MSA.3, FMT_MTD.1, FMT_MTD.3, FMT_SMF.1, FMT_SMR.1, FMT_MSA.1.1, FMT_MSA.3.1, FMT_MSA.3.2, FMT_MTD.1.1, FMT_MTD.3.1, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FPT_PHP.1, FPT_STM.1, FPT_TST.1, FPT_STM.1.1, FPT_PHP.1.1, FPT_PHP.1.2, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FTA_SSL.3, FTA_SSL.4, FTA_SSL.3.1, FTA_SSL.4.1, FTP_ITC.1
Protection profiles
BSI-CC-PP-0052, BSI-CC-PP-0032

Side-channel analysis
physical tampering
Certification process
out of scope, done by an authorised card that is out of scope of this PP, of the TOE Signature generation for emergency data1 on the eHC (done by an authorised card that is out of scope of this PP) 1.2.7 Physical Protection of the TOE The TOE cannot counter physical attacks concerning

Standards
X.509, CCMB-2012-09-002, CCMB-2012-09-003
Technical reports
BSI 0, BSI 1, BSI 7500, BSI 7586

References

Automated inference - use with caution

All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.

Processing updates

Feed
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile was first processed.

Raw data

{
  "_id": "854be21fba7a106c",
  "_type": "sec_certs.sample.protection_profile.ProtectionProfile",
  "dgst": "854be21fba7a106c",
  "heuristics": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.Heuristics"
  },
  "pdf_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.PdfData",
    "pp_filename": "pp0052b_pdf.pdf",
    "pp_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {},
      "cc_claims": {
        "A": {
          "A.ADMIN": 3,
          "A.CARDS": 4,
          "A.DMS": 4,
          "A.ENVIRONMENT": 3,
          "A.MEDIC": 3,
          "A.PHYSICAL": 2
        },
        "O": {
          "O.AUTH_STATE": 8,
          "O.DMS_CONNECT": 1,
          "O.DMS_CONNECTION": 4,
          "O.LOG_CARDS": 3,
          "O.LOG_DATA": 5,
          "O.MANAGEMENT": 9,
          "O.PIN": 6,
          "O.PROTECTION": 8,
          "O.RESIDUAL": 6,
          "O.SEALING": 3,
          "O.SELFTESTS": 5,
          "O.TIME": 5,
          "O.TRANSFER": 3
        },
        "OE": {
          "OE.ADMIN": 9,
          "OE.CARDS": 7,
          "OE.DEVELOPER": 1,
          "OE.DMS": 4,
          "OE.ENVIRON": 1,
          "OE.ENVIRONMENT": 5,
          "OE.MEDIC": 9,
          "OE.PHYSICAL": 6
        },
        "OSP": {
          "OSP.DMS_CONNECT": 1,
          "OSP.DMS_CONNECTION": 2,
          "OSP.EMERGENCY_D": 1,
          "OSP.EMERGENCY_DATA": 1,
          "OSP.LOG_CARDS": 3,
          "OSP.LOG_DATA": 3,
          "OSP.SEALING": 3,
          "OSP.SELFTESTS": 3,
          "OSP.TIME": 3,
          "OSP.TRANSFER": 3
        },
        "T": {
          "T.ACCESS": 3,
          "T.ADMIN_PIN": 3,
          "T.AUTH_STATE": 3,
          "T.DATA": 3,
          "T.FIRMWARE": 3,
          "T.MAN_HW": 4
        }
      },
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0032": 1,
          "BSI-CC-PP-0052": 3
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC.1": 1,
          "ADV_FSP.4": 5,
          "ADV_IMP.1": 5,
          "ADV_TDS.3": 5
        },
        "AGD": {
          "AGD_OPE.1": 1,
          "AGD_PRE.1": 1
        },
        "ALC": {
          "ALC_CMC.3": 1,
          "ALC_CMS.3": 1,
          "ALC_DEL.1": 1,
          "ALC_DVS.1": 1,
          "ALC_LCD.1": 1,
          "ALC_TAT.1": 5
        },
        "ATE": {
          "ATE_COV.2": 1,
          "ATE_DPT.1": 1,
          "ATE_FUN.1": 1,
          "ATE_IND.2": 1
        },
        "AVA": {
          "AVA_VAN.5": 8
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 3": 5,
          "EAL 3 augmented": 4
        }
      },
      "cc_sfr": {
        "FCS": {
          "FCS_CKM.1": 19,
          "FCS_CKM.1.1": 1,
          "FCS_CKM.2": 2,
          "FCS_CKM.4": 19,
          "FCS_CKM.4.1": 1,
          "FCS_COP": 21,
          "FCS_COP.1": 6
        },
        "FDP": {
          "FDP_ACC.1": 23,
          "FDP_ACC.1.1": 1,
          "FDP_ACF.1": 17,
          "FDP_ACF.1.1": 1,
          "FDP_ACF.1.2": 4,
          "FDP_ACF.1.3": 1,
          "FDP_ACF.1.4": 3,
          "FDP_IFC": 43,
          "FDP_IFC.1": 13,
          "FDP_IFF": 39,
          "FDP_IFF.1": 26,
          "FDP_ITC.1": 19,
          "FDP_ITC.1.1": 1,
          "FDP_ITC.1.2": 1,
          "FDP_ITC.1.3": 1,
          "FDP_ITC.2": 9,
          "FDP_RIP": 10,
          "FDP_RIP.1": 2,
          "FDP_SDI.1": 1,
          "FDP_SDI.2": 6,
          "FDP_SDI.2.1": 1,
          "FDP_SDI.2.2": 1,
          "FDP_SVR": 2,
          "FDP_SVR.1": 10,
          "FDP_SVR.1.1": 5,
          "FDP_SVR.1.2": 3,
          "FDP_SVR.1.3": 3
        },
        "FIA": {
          "FIA_AFL.1": 6,
          "FIA_AFL.1.1": 1,
          "FIA_AFL.1.2": 1,
          "FIA_SOS.1": 5,
          "FIA_SOS.1.1": 1,
          "FIA_UAU.1": 11,
          "FIA_UAU.1.1": 1,
          "FIA_UAU.1.2": 1,
          "FIA_UAU.5": 8,
          "FIA_UAU.5.1": 1,
          "FIA_UAU.5.2": 1,
          "FIA_UAU.7": 8,
          "FIA_UAU.7.1": 2,
          "FIA_UID.1": 15,
          "FIA_UID.1.1": 1,
          "FIA_UID.1.2": 1
        },
        "FMT": {
          "FMT_MSA.1": 9,
          "FMT_MSA.1.1": 1,
          "FMT_MSA.3": 25,
          "FMT_MSA.3.1": 1,
          "FMT_MSA.3.2": 1,
          "FMT_MTD.1": 8,
          "FMT_MTD.1.1": 1,
          "FMT_MTD.3": 5,
          "FMT_MTD.3.1": 1,
          "FMT_SMF.1": 11,
          "FMT_SMF.1.1": 1,
          "FMT_SMR.1": 18,
          "FMT_SMR.1.1": 1,
          "FMT_SMR.1.2": 1
        },
        "FPT": {
          "FPT_PHP.1": 5,
          "FPT_PHP.1.1": 1,
          "FPT_PHP.1.2": 1,
          "FPT_STM.1": 10,
          "FPT_STM.1.1": 1,
          "FPT_TST.1": 5,
          "FPT_TST.1.1": 1,
          "FPT_TST.1.2": 1,
          "FPT_TST.1.3": 1
        },
        "FTA": {
          "FTA_SSL.3": 7,
          "FTA_SSL.3.1": 2,
          "FTA_SSL.4": 7,
          "FTA_SSL.4.1": 1
        },
        "FTP": {
          "FTP_ITC.1": 1
        }
      },
      "certification_process": {
        "OutOfScope": {
          "done by an authorised card that is out of scope of this PP": 1,
          "of the TOE Signature generation for emergency data1 on the eHC (done by an authorised card that is out of scope of this PP) 1.2.7 Physical Protection of the TOE The TOE cannot counter physical attacks concerning": 1,
          "out of scope": 1
        }
      },
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {
        "FI": {
          "physical tampering": 4
        }
      },
      "standard_id": {
        "CC": {
          "CCMB-2012-09-002": 1,
          "CCMB-2012-09-003": 1
        },
        "X509": {
          "X.509": 5
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 3
          },
          "HPC": {
            "HPC": 11
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI 0": 1,
          "BSI 1": 2,
          "BSI 7500": 1,
          "BSI 7586": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "pp_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
      "/CreationDate": "D:20150126121253+01\u002700\u0027",
      "/Creator": "Microsoft\u00ae Word 2010",
      "/Keywords": "Protection Profile, Mobile Card Terminal, Electronic Health Card",
      "/ModDate": "D:20150127161118+01\u002700\u0027",
      "/Producer": "Microsoft\u00ae Word 2010",
      "/Subject": "Mobile Card Terminal, electronic Health Card",
      "/Title": "Common Criteria Protection Profile BSI-PP-0052",
      "pdf_file_size_bytes": 858202,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 69
    },
    "report_filename": "pp0052a_pdf.pdf",
    "report_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {},
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0052": 1,
          "BSI-CC-PP-0052-2015": 15
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC": 1,
          "ADV_ARC.1": 1,
          "ADV_FSP": 1,
          "ADV_FSP.1": 1,
          "ADV_FSP.2": 1,
          "ADV_FSP.3": 1,
          "ADV_FSP.4": 3,
          "ADV_FSP.5": 1,
          "ADV_FSP.6": 1,
          "ADV_IMP": 1,
          "ADV_IMP.1": 3,
          "ADV_IMP.2": 1,
          "ADV_INT": 1,
          "ADV_INT.1": 1,
          "ADV_INT.2": 1,
          "ADV_INT.3": 1,
          "ADV_SPM": 1,
          "ADV_SPM.1": 1,
          "ADV_TDS": 1,
          "ADV_TDS.1": 1,
          "ADV_TDS.2": 1,
          "ADV_TDS.3": 3,
          "ADV_TDS.4": 1,
          "ADV_TDS.5": 1,
          "ADV_TDS.6": 1
        },
        "AGD": {
          "AGD_OPE": 1,
          "AGD_OPE.1": 1,
          "AGD_PRE": 1,
          "AGD_PRE.1": 1
        },
        "ALC": {
          "ALC_CMC": 1,
          "ALC_CMC.1": 1,
          "ALC_CMC.2": 1,
          "ALC_CMC.3": 1,
          "ALC_CMC.4": 1,
          "ALC_CMC.5": 1,
          "ALC_CMS": 1,
          "ALC_CMS.1": 1,
          "ALC_CMS.2": 1,
          "ALC_CMS.3": 1,
          "ALC_CMS.4": 1,
          "ALC_CMS.5": 1,
          "ALC_DEL": 1,
          "ALC_DEL.1": 1,
          "ALC_DVS": 1,
          "ALC_DVS.1": 1,
          "ALC_DVS.2": 1,
          "ALC_FLR": 3,
          "ALC_FLR.1": 1,
          "ALC_FLR.2": 1,
          "ALC_FLR.3": 1,
          "ALC_LCD.1": 1,
          "ALC_LCD.2": 1,
          "ALC_TAT": 1,
          "ALC_TAT.1": 3,
          "ALC_TAT.2": 1,
          "ALC_TAT.3": 1
        },
        "APE": {
          "APE_CCL.1": 2,
          "APE_ECD.1": 2,
          "APE_INT.1": 2,
          "APE_OBJ.1": 1,
          "APE_OBJ.2": 2,
          "APE_REQ.1": 1,
          "APE_REQ.2": 2,
          "APE_SPD.1": 2
        },
        "ASE": {
          "ASE_CCL": 1,
          "ASE_CCL.1": 1,
          "ASE_ECD": 1,
          "ASE_ECD.1": 1,
          "ASE_INT": 1,
          "ASE_INT.1": 1,
          "ASE_OBJ": 1,
          "ASE_OBJ.1": 1,
          "ASE_OBJ.2": 1,
          "ASE_REQ.1": 1,
          "ASE_REQ.2": 1,
          "ASE_SPD": 1,
          "ASE_SPD.1": 1,
          "ASE_TSS": 1,
          "ASE_TSS.1": 1,
          "ASE_TSS.2": 1
        },
        "ATE": {
          "ATE_COV": 1,
          "ATE_COV.1": 1,
          "ATE_COV.2": 1,
          "ATE_COV.3": 1,
          "ATE_DPT": 1,
          "ATE_DPT.1": 1,
          "ATE_DPT.2": 1,
          "ATE_DPT.3": 1,
          "ATE_DPT.4": 1,
          "ATE_FUN": 1,
          "ATE_FUN.1": 1,
          "ATE_FUN.2": 1,
          "ATE_IND": 1,
          "ATE_IND.1": 1,
          "ATE_IND.2": 1,
          "ATE_IND.3": 1
        },
        "AVA": {
          "AVA_VAN": 2,
          "AVA_VAN.1": 1,
          "AVA_VAN.2": 1,
          "AVA_VAN.3": 1,
          "AVA_VAN.4": 1,
          "AVA_VAN.5": 3
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 1": 1,
          "EAL 2": 1,
          "EAL 4": 6,
          "EAL1": 6,
          "EAL2": 3,
          "EAL3": 4,
          "EAL4": 4,
          "EAL5": 6,
          "EAL6": 3,
          "EAL7": 4
        },
        "ITSEC": {
          "ITSEC Evaluation": 1
        }
      },
      "cc_sfr": {},
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {},
      "standard_id": {
        "BSI": {
          "AIS 14": 1,
          "AIS 32": 1
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 1
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI 2": 1,
          "BSI 7125": 2,
          "BSI 7148": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "report_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
      "/CreationDate": "D:20150126111358+01\u002700\u0027",
      "/Creator": "Writer",
      "/Keywords": "\"Common Criteria, Certification, Zertifizierung, Protection Profile, Schutzprofil\"",
      "/ModDate": "D:20150126160211+01\u002700\u0027",
      "/Producer": "LibreOffice 4.2",
      "/Subject": "Mobile Card Terminal for the German Healthcare System",
      "/Title": "Certification Report BSI-CC-PP-0052-2015",
      "pdf_file_size_bytes": 827449,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": [
          "https://www.bsi.bund.de/zertifizierung",
          "http://www.commoncriteriaportal.org/",
          "https://www.bsi.bund.de/"
        ]
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 30
    }
  },
  "scheme_metadata": null,
  "state": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.InternalState",
    "pp": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": "64208b8bf119d80d4e875995e1fdd328227c39d82d3f984f12efe4edc3ab3617",
      "txt_hash": "190fa4899ad1f5a2c2015aa02f2f9c8da15ec8df17c90fec9838740dc7ad5fc4"
    },
    "report": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": "bb39cde65f9d33ad512f01c5b154204c7279efa5dd2529b0e618b951d5ca1f26",
      "txt_hash": "7addb0a7e9902bb9c7a47332ff15831f1a4b5174017747e7aabc0482297b86da"
    }
  },
  "web_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.WebData",
    "category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
    "is_collaborative": false,
    "maintenances": [],
    "name": "Common Criteria Protection Profile Mobile Card Terminal for the German Healthcare System (MobCT)",
    "not_valid_after": "2025-01-19",
    "not_valid_before": "2015-01-19",
    "pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0052b_pdf.pdf",
    "report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0052a_pdf.pdf",
    "scheme": "DE",
    "security_level": {
      "_type": "Set",
      "elements": [
        "ADV_IMP.1",
        "ALC_TAT.1",
        "AVA_VAN.5",
        "ADV_FSP.4",
        "EAL3+",
        "ADV_TDS.3"
      ]
    },
    "status": "archived",
    "version": "Version 1.4"
  }
}