SMGW Version 1.2
CSV information ?
Status | active |
---|---|
Valid from | 05.09.2021 |
Valid until | 05.09.2029 |
Scheme | 🇩🇪 DE |
Manufacturer | Power Plus Communications AG |
Category | Other Devices and Systems |
Security level | AVA_VAN.5, ALC_FLR.2, EAL4+ |
Protection profiles | |
Maintenance updates | SMGW, Version 1.2.2 (15.02.2022) Certification report |
SMGW, Version 1.2SMGW, Version 1.2.1SMGW, Version 1.2.2 (04.09.2023) Certification report Security target | |
SMGW, Version 1.2 (04.03.2022) Certification report | |
SMGW, Version 1.2, Version 1.2.1 and Version 1.2.2 (27.06.2024) Certification report | |
SMGW, Version 1.2.1 (15.12.2021) Certification report |
Heuristics summary ?
Certificate ?
Extracted keywords
Security level
EAL 4, EAL 5, EAL 2, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5Certificates
BSI-DSZ-CC-0831-V4-2021Standards
ISO/IEC 15408, ISO/IEC 18045File metadata
Title | Certificate BSI-DSZ-CC-0831-V4-2021 |
---|---|
Subject | Zertifizierungsverfahren SMGW Version 1.2 |
Keywords | "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Smart Metering, Smart Grid" |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20210910114419+02'00' |
Modification date | D:20210913105516+02'00' |
Pages | 1 |
Creator | Writer |
Producer | LibreOffice 6.3 |
Certification report ?
Extracted keywords
Symmetric Algorithms
CMACAsymmetric Algorithms
ECCHash functions
SHA-256, SHA-384, SHA-512, SHA2Protocols
SSH, TLSSecurity level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 2+, EAL 5+, EAL 6, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5Protection profiles
BSI-CC-PP-0073-2014Certificates
BSI-DSZ-CC-0831-V4-2021, BSI-DSZ-CC-0831-V3-2021, BSI-DSZ-CC-0957-V2-2016Evaluation facilities
TÃœV InformationstechnikSide-channel analysis
physical tamperingCertification process
being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, AG [7] Evaluation Technical Report, Version 2, 2021-07-27, TÜV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, Configuration list for the TOE, Version 153, 2021-06-30, EVG-CM-List, Power Plus Communications AG (confidential document) [10] Handbuch für Verbraucher, Smart Meter Gateway, Version 4.6, 2021-06-10 [11] Handbuch fürStandards
FIPS180-4, AIS 34, AIS 46, AIS 1, AIS 32, AIS 38, AIS 48, RFC3565, RFC5652, RFC6033, RFC4493, RFC5084, RFC5246, RFC5288, RFC2104, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065Technical reports
BSI TR-03109-1, BSI TR-03116-3, BSI TR-02102-1, BSI 7148File metadata
Title | Certification Report BSI-DSZ-CC-0831-V4-2021 |
---|---|
Keywords | "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Smart Metering, Smart Grid" |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20210910114419+02'00' |
Modification date | D:20210910133736+02'00' |
Pages | 24 |
Creator | Writer |
Producer | LibreOffice 6.3 |
Frontpage
Certificate ID | BSI-DSZ-CC-0831-V4-2021 |
---|---|
Certified item | SMGW Version 1.2 |
Certification lab | BSI |
Developer | Power Plus Communications AG |
References
Outgoing- BSI-DSZ-CC-0957-V2-2016 - active - TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA
- BSI-DSZ-CC-0831-V3-2021 - active - SMGW, Version 1.1.1
- BSI-DSZ-CC-0831-V6-2023 - active - Smart Meter GatewaySMGWVersion 1.3
- BSI-DSZ-CC-0831-V5-2022 - active - SMGW Version 2.0
Security target ?
Extracted keywords
Symmetric Algorithms
AES, AES-, CMACAsymmetric Algorithms
ECDSA, ECC, Diffie-HellmanHash functions
SHA-256, SHA-384, SHA-512Schemes
MAC, Key AgreementProtocols
TLS, TLS 1.2, PACEElliptic Curves
P-256, P-384, NIST P-256, NIST P-384Block cipher modes
CBC, GCM, XTSTLS cipher suites
TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384, TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384Security level
EAL 4+, EAL4, EAL 4, EAL 2609, EAL4 augmented, EAL 4 augmentedClaims
OE.SM, OSP.SMSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_IMP.1, AGD_GWA, AGD_SEC, AGD_OPE.1, ALC_FLR.2, ALC_CMC.4, ALC_DEL.1, ALC_LCD.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5, ASE_CCL.1, ASE_INT.1, ASE_REQ.2, ASE_TSS.1Security Functional Requirements (SFR)
FAU_ARP, FAU_GEN, FAU_SAA, FAU_SAR, FAU_STG, FAU_GEN.2, FAU_STG.2, FAU_ARP.1, FAU_SAA.1, FAU_GEN.1, FAU_SAA.1.1, FAU_SAR.1, FAU_STG.4, FAU_STG.3, FAU_STG.1, FAU_GEN.2.1, FAU_STG.2.1, FAU_STG.2.2, FAU_STG.2.3, FCO_NRO, FCO_NRO.2, FCO_NRO.2.1, FCO_NRO.2.2, FCO_NRO.2.3, FCO_NRO.1, FCS_CKM, FCS_COP, FCS_CKM.4, FCS_CKM.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_IFC, FDP_ACC.2, FDP_ACF.1, FDP_IFF, FDP_RIP.2, FDP_SDI.2, FDP_ITC.1, FDP_ITC.2, FDP_ACC, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACC.1, FDP_ACF, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_IFC.2, FDP_IFC.1, FDP_IFF.1, FDP_IFF.1.3, FDP_RIP, FDP_RIP.2.1, FDP_RIP.1, FDP_SDI, FDP_SDI.2.1, FDP_SDI.2.2, FDP_SDI.1, FIA_ATD, FIA_AFL, FIA_UAU, FIA_UID, FIA_USB, FIA_ATD.1, FIA_AFL.1, FIA_UAU.2, FIA_UAU.5, FIA_UAU.6, FIA_UID.2, FIA_USB.1, FIA_UID.1, FIA_ATD.1.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_UAU.1, FIA_UAU.2.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UAU.6.1, FIA_UID.2.1, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_SMR, FMT_MOF.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA, FMT_MSA.3, FMT_MOF, FMT_MOF.1.1, FMT_SMF, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MSA.1, FPR_CON, FPR_CON.1, FPR_PSE, FPR_CON.1.2, FPR_CON.1.1, FPR_PSE.1, FPR_PSE.1.1, FPR_PSE.1.2, FPR_PSE.1.3, FPT_FLS, FPT_RPL, FPT_STM, FPT_TST, FPT_PHP, FPT_FLS.1, FPT_RPL.1, FPT_STM.1, FPT_TST.1, FPT_PHP.1, FPT_FLS.1.1, FPT_RPL.1.1, FPT_RPL.1.2, FPT_STM.1.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_PHP.1.1, FPT_PHP.1.2, FTP_ITC, FTP_ITC.1Certificates
BSI-DSZ-CC-0831-, BSI-DSZ-CC-0831-V4-2021Side-channel analysis
physical tampering, malfunctionStandards
FIPS 140-3, FIPS 180-4, FIPS 197, RFC 5246, RFC 2104, RFC 5639, RFC 5114, RFC 5289, RFC 3565, RFC 4493, RFC 5084, RFC 5652, RFC 3394, RFC 7616, RFC 2616, RFC 5083, ISO/IEC 10116:2006, X.509, CCMB-2017-04-001, CCMB-2017-04-002, CCMB-2017-04-003Technical reports
BSI TR-02102, BSI TR-03109, BSI TR-03109-1, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03109-4, BSI TR-03109-6, BSI TR-03111, BSI TR-03116-3File metadata
Creation date | D:20210901124429+02'00' |
---|---|
Modification date | D:20210901124429+02'00' |
Pages | 173 |
Heuristics ?
Extracted SARs
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_CMC.4, ALC_DEL.1, ALC_FLR.2, ALC_LCD.1, ASE_CCL.1, ASE_INT.1, ASE_REQ.2, ASE_TSS.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5Certificate versions
Name | Certificate ID | |
---|---|---|
Previous | ||
SMGW-Integrationsmodul, Version 1.0 | BSI-DSZ-CC-0831-2018 | Compare |
SMGW Version 1.1 | BSI-DSZ-CC-0831-V2-2020 | Compare |
SMGW, Version 1.1.1 | BSI-DSZ-CC-0831-V3-2021 | Compare |
Next | ||
SMGW Version 2.0 | BSI-DSZ-CC-0831-V5-2022 | Compare |
Smart Meter GatewaySMGWVersion 2.1 | BSI-DSZ-CC-0831-V7-2023 | Compare |
Smart Meter GatewaySMGWVersion 1.3 | BSI-DSZ-CC-0831-V6-2023 | Compare |
SMGW Version 1.3.1 | BSI-DSZ-CC-0831-V8-2024 | Compare |
SMGW Version 2.1.1 | BSI-DSZ-CC-0831-V9-2024 | Compare |
References ?
Updates ?
-
21.11.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The following values were inserted:
{'prev_certificates': ['BSI-DSZ-CC-0831-2018', 'BSI-DSZ-CC-0831-V2-2020', 'BSI-DSZ-CC-0831-V3-2021'], 'next_certificates': ['BSI-DSZ-CC-0831-V5-2022', 'BSI-DSZ-CC-0831-V6-2023', 'BSI-DSZ-CC-0831-V7-2023', 'BSI-DSZ-CC-0831-V8-2024', 'BSI-DSZ-CC-0831-V9-2024']}
.
- The following values were inserted:
-
09.11.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The report_references property was updated, with the
{'indirectly_referenced_by': {'__add__': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0831-V8-2024', 'BSI-DSZ-CC-0831-V9-2024']}}}
data. - The scheme_data property was set to
None
.
- The report_references property was updated, with the
-
17.10.2024 The certificate data changed.
Certificate changed
The Protection Profiles of the certificate were updated.
- The new value is
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.protection_profile.ProtectionProfile', 'pp_name': 'Protection Profile for the Gateway of a Smart Metering System', 'pp_eal': 'EAL4+', 'pp_link': 'https://www.commoncriteriaportal.org/files/ppfiles/pp0073b_pdf.pdf', 'pp_ids': {'_type': 'Set', 'elements': ['SMARTMETERGATEWAYPP_V1.3']}}]}
.
- The new value is
-
07.10.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was updated, with the
{'cert_id': 'BSI-DSZ-CC-0831-V9-2024', 'certification_date': '06.09.2024', 'enhanced': {'__update__': {'certification_date': '06.09.2024', 'expiration_date': '05.09.2032', 'entries': {'0': {'__update__': {'id': 'BSI-DSZ-CC-0831-V9-2024', 'description': 'Certificate'}}, '1': {'__update__': {'id': 'BSI-DSZ-CC-0831-V8-2024', 'description': 'Certificate'}}, '2': {'__update__': {'id': 'BSI-DSZ-CC-0831-V7-2023-MA-02', 'description': 'Sky-/Safety'}}, '3': {'__update__': {'id': 'BSI-DSZ-CC-0831-V7-2023-MA-01', 'description': 'Maintenance Report'}}, '4': {'__update__': {'id': 'BSI-DSZ-CC-0831-V7-2023'}}, '6': {'__update__': {'description': 'The focus of this re-certification was on changes to the wMBUS-functionality, profile adjustments as well as further improvements.'}}, '8': {'__update__': {'description': 'The focus of this re-certification laid on the update of the linux kernel, a new hardware configuration, optimizations and bugfixing as well as changes in the developpment process.'}}, '__delete__': [2]}, 'report_link': 'https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0831V9a_pdf.pdf?__blob=publicationFile&v=2', 'target_link': 'https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0831V9b_pdf.pdf?__blob=publicationFile&v=3', 'cert_link': 'https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0831V9c_pdf.pdf?__blob=publicationFile&v=2'}}}
data.
- The scheme_data property was updated, with the
-
09.09.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was updated, with the
{'enhanced': {'__update__': {'entries': {'__insert__': [[0, {'id': 'BSI-DSZ-CC-0831-V7-2023-MA-02', 'description': 'Sky-/Safety'}]]}}}}
data.
- The scheme_data property was updated, with the
-
22.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'c06275697885e8fec86c0bd89eaa8ea4aeb7fbf331000c2301676101afd39e67', 'txt_hash': '5f64fc23ad7ebb444001db5a4b8d328d51f47011b6ed44433d4b8b19e95add88'}
data. - The st property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'fb342a544f5df30e74cefe44c737dbd79eb2a58e830492515c67cab34517abb8', 'txt_hash': 'ecb50cc9ce982334178e8dbceb6dc4efd0d68b11ce344f2ca684448a460f6814'}
data. - The cert property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'f5cbd6587f98f3561c8b0ce7032634dd983b9bfac70fc06f086bd35d76671e76', 'txt_hash': '059f2f0b58105a2bf5fdbd3eeea7818db95e6c0fef857c5b9f36691edba3322c'}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
{'pdf_file_size_bytes': 718909, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 24, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20210910114419+02'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Smart Metering, Smart Grid"', '/ModDate': "D:20210910133736+02'00'", '/Producer': 'LibreOffice 6.3', '/Title': 'Certification Report BSI-DSZ-CC-0831-V4-2021', 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['https://www.bsi.bund.de/', 'https://www.sogis.eu/', 'https://www.bsi.bund.de/zertifizierung', 'http://www.commoncriteriaportal.org/cc/', 'https://www.bsi.bund.de/zertifizierungsreporte', 'http://www.commoncriteriaportal.org/', 'https://www.bsi.bund.de/AIS']}}
. - The st_metadata property was set to
{'pdf_file_size_bytes': 1273907, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 173, '/CreationDate': "D:20210901124429+02'00'", '/ModDate': "D:20210901124429+02'00'", 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['http://rfc-editor.org/rfc/rfc2104.txt', 'http://rfc-editor.org/rfc/rfc7616.txt', 'http://de.wikipedia.org/wiki/Ethernet', 'http://rfc-editor.org/rfc/rfc2616.txt', 'http://fc12.ifca.ai/pre-proceedings/paper_49.pdf', 'http://www.ietf.org/rfc/rfc5246.txt', 'http://www.ietf.org/rfc/rfc5083.txt', 'http://rfc-editor.org/rfc/rfc3394.txt', 'http://www.ppc-ag.com/', 'http://de.wikipedia.org/wiki/Open_Metering_System', 'http://www.rfc-editor.org/rfc/rfc4493.txt', 'http://www.ietf.org/rfc/rfc5639.txt', 'http://www.ietf.org/rfc/rfc5114.txt', 'http://www.usb.org/developers/docs/usb20_docs/%23usb20spec', 'http://www.ietf.org/rfc/rfc5084.txt', 'http://en.wikipedia.org/wiki/Network_interface_device', 'http://www.ietf.org/rfc/rfc5289.txt', 'http://www.ietf.org/rfc/rfc5652.txt', 'http://rfc-editor.org/rfc/rfc3565.txt', 'http://csrc.nist.gov/publications/nistpubs/800-38D/SP-800-38D.pdf']}}
. - The cert_metadata property was set to
{'pdf_file_size_bytes': 374477, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 1, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20210910114419+02'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Smart Metering, Smart Grid"', '/ModDate': "D:20210913105516+02'00'", '/Producer': 'LibreOffice 6.3', '/Subject': 'Zertifizierungsverfahren SMGW Version 1.2', '/Title': 'Certificate BSI-DSZ-CC-0831-V4-2021', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}
. - The report_frontpage property was set to
{'DE': {'match_rules': ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)'], 'cert_id': 'BSI-DSZ-CC-0831-V4-2021', 'cert_item': 'SMGW Version 1.2', 'developer': 'Power Plus Communications AG', 'cert_lab': 'BSI', 'ref_protection_profiles': 'Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014', 'cc_version': 'PP conformant Common Criteria Part 2 extended', 'cc_security_level': 'Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2'}}
. - The report_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-0831-V4-2021': 13, 'BSI-DSZ-CC-0831-V3-2021': 3, 'BSI-DSZ-CC-0957-V2-2016': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0073-2014': 3}}, 'cc_security_level': {'EAL': {'EAL 4': 8, 'EAL 5': 3, 'EAL 2': 2, 'EAL 1': 1, 'EAL 2+': 1, 'EAL 5+': 1, 'EAL 6': 1, 'EAL 4 augmented': 3}}, 'cc_sar': {'ALC': {'ALC_FLR.2': 4, 'ALC_FLR': 3}, 'AVA': {'AVA_VAN.5': 5}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {'TUV': {'TÜV Informationstechnik': 3}}, 'symmetric_crypto': {'constructions': {'MAC': {'CMAC': 3}}}, 'asymmetric_crypto': {'ECC': {'ECC': {'ECC': 2}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA-256': 1, 'SHA-384': 1, 'SHA-512': 1, 'SHA2': 1}}}, 'crypto_scheme': {}, 'crypto_protocol': {'SSH': {'SSH': 1}, 'TLS': {'TLS': {'TLS': 5}}}, 'randomness': {}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'FI': {'physical tampering': 1}}, 'technical_report_id': {'BSI': {'BSI TR-03109-1': 1, 'BSI TR-03116-3': 1, 'BSI TR-02102-1': 1, 'BSI 7148': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS180-4': 3}, 'BSI': {'AIS 34': 2, 'AIS 46': 2, 'AIS 1': 1, 'AIS 32': 1, 'AIS 38': 1, 'AIS 48': 1}, 'RFC': {'RFC3565': 1, 'RFC5652': 2, 'RFC6033': 1, 'RFC4493': 3, 'RFC5084': 1, 'RFC5246': 4, 'RFC5288': 1, 'RFC2104': 2}, 'ISO': {'ISO/IEC 15408': 4, 'ISO/IEC 18045': 4, 'ISO/IEC 17065': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'ConfidentialDocument': {'being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification': 1, 'AG [7] Evaluation Technical Report, Version 2, 2021-07-27, TÜV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014': 1, 'Configuration list for the TOE, Version 153, 2021-06-30, EVG-CM-List, Power Plus Communications AG (confidential document) [10] Handbuch für Verbraucher, Smart Meter Gateway, Version 4.6, 2021-06-10 [11] Handbuch für': 1}}}
. - The st_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-0831-': 1, 'BSI-DSZ-CC-0831-V4-2021': 1}}, 'cc_protection_profile_id': {}, 'cc_security_level': {'EAL': {'EAL 4+': 1, 'EAL4': 1, 'EAL 4': 3, 'EAL 2609': 1, 'EAL4 augmented': 1, 'EAL 4 augmented': 1}}, 'cc_sar': {'ADV': {'ADV_ARC.1': 1, 'ADV_IMP.1': 1}, 'AGD': {'AGD_GWA': 2, 'AGD_SEC': 3, 'AGD_OPE.1': 1}, 'ALC': {'ALC_FLR.2': 6, 'ALC_CMC.4': 1, 'ALC_DEL.1': 1, 'ALC_LCD.1': 1}, 'ATE': {'ATE_COV.2': 1, 'ATE_FUN.1': 1}, 'AVA': {'AVA_VAN.5': 7}, 'ASE': {'ASE_CCL.1': 1, 'ASE_INT.1': 1, 'ASE_REQ.2': 1, 'ASE_TSS.1': 1}}, 'cc_sfr': {'FAU': {'FAU_ARP': 10, 'FAU_GEN': 37, 'FAU_SAA': 10, 'FAU_SAR': 28, 'FAU_STG': 29, 'FAU_GEN.2': 8, 'FAU_STG.2': 13, 'FAU_ARP.1': 1, 'FAU_SAA.1': 3, 'FAU_GEN.1': 17, 'FAU_SAA.1.1': 1, 'FAU_SAR.1': 7, 'FAU_STG.4': 3, 'FAU_STG.3': 3, 'FAU_STG.1': 7, 'FAU_GEN.2.1': 1, 'FAU_STG.2.1': 1, 'FAU_STG.2.2': 1, 'FAU_STG.2.3': 1}, 'FCO': {'FCO_NRO': 3, 'FCO_NRO.2': 10, 'FCO_NRO.2.1': 1, 'FCO_NRO.2.2': 1, 'FCO_NRO.2.3': 1, 'FCO_NRO.1': 1}, 'FCS': {'FCS_CKM': 41, 'FCS_COP': 58, 'FCS_CKM.4': 33, 'FCS_CKM.1': 17, 'FCS_CKM.2': 6, 'FCS_COP.1': 11, 'FCS_CKM.4.1': 1}, 'FDP': {'FDP_IFC': 27, 'FDP_ACC.2': 10, 'FDP_ACF.1': 9, 'FDP_IFF': 22, 'FDP_RIP.2': 9, 'FDP_SDI.2': 8, 'FDP_ITC.1': 12, 'FDP_ITC.2': 12, 'FDP_ACC': 2, 'FDP_ACC.2.1': 1, 'FDP_ACC.2.2': 1, 'FDP_ACC.1': 9, 'FDP_ACF': 1, 'FDP_ACF.1.1': 1, 'FDP_ACF.1.2': 1, 'FDP_ACF.1.3': 1, 'FDP_ACF.1.4': 1, 'FDP_IFC.2': 4, 'FDP_IFC.1': 12, 'FDP_IFF.1': 19, 'FDP_IFF.1.3': 1, 'FDP_RIP': 2, 'FDP_RIP.2.1': 1, 'FDP_RIP.1': 1, 'FDP_SDI': 2, 'FDP_SDI.2.1': 1, 'FDP_SDI.2.2': 1, 'FDP_SDI.1': 1}, 'FIA': {'FIA_ATD': 3, 'FIA_AFL': 3, 'FIA_UAU': 5, 'FIA_UID': 3, 'FIA_USB': 3, 'FIA_ATD.1': 12, 'FIA_AFL.1': 7, 'FIA_UAU.2': 7, 'FIA_UAU.5': 6, 'FIA_UAU.6': 7, 'FIA_UID.2': 11, 'FIA_USB.1': 11, 'FIA_UID.1': 8, 'FIA_ATD.1.1': 1, 'FIA_AFL.1.1': 1, 'FIA_AFL.1.2': 1, 'FIA_UAU.1': 2, 'FIA_UAU.2.1': 1, 'FIA_UAU.5.1': 1, 'FIA_UAU.5.2': 2, 'FIA_UAU.6.1': 1, 'FIA_UID.2.1': 1, 'FIA_USB.1.1': 1, 'FIA_USB.1.2': 1, 'FIA_USB.1.3': 1}, 'FMT': {'FMT_SMR': 3, 'FMT_MOF.1': 9, 'FMT_SMF.1': 18, 'FMT_SMR.1': 28, 'FMT_MSA': 55, 'FMT_MSA.3': 12, 'FMT_MOF': 2, 'FMT_MOF.1.1': 1, 'FMT_SMF': 2, 'FMT_SMF.1.1': 1, 'FMT_SMR.1.1': 1, 'FMT_SMR.1.2': 1, 'FMT_MSA.1': 9}, 'FPR': {'FPR_CON': 6, 'FPR_CON.1': 10, 'FPR_PSE': 2, 'FPR_CON.1.2': 4, 'FPR_CON.1.1': 2, 'FPR_PSE.1': 8, 'FPR_PSE.1.1': 1, 'FPR_PSE.1.2': 1, 'FPR_PSE.1.3': 1}, 'FPT': {'FPT_FLS': 3, 'FPT_RPL': 3, 'FPT_STM': 3, 'FPT_TST': 3, 'FPT_PHP': 3, 'FPT_FLS.1': 8, 'FPT_RPL.1': 10, 'FPT_STM.1': 17, 'FPT_TST.1': 9, 'FPT_PHP.1': 7, 'FPT_FLS.1.1': 1, 'FPT_RPL.1.1': 1, 'FPT_RPL.1.2': 1, 'FPT_STM.1.1': 1, 'FPT_TST.1.1': 1, 'FPT_TST.1.2': 1, 'FPT_TST.1.3': 1, 'FPT_PHP.1.1': 1, 'FPT_PHP.1.2': 1}, 'FTP': {'FTP_ITC': 27, 'FTP_ITC.1': 9}}, 'cc_claims': {'OE': {'OE.SM': 4}, 'OSP': {'OSP.SM': 5}}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 14, 'AES-': 1}}, 'constructions': {'MAC': {'CMAC': 10}}}, 'asymmetric_crypto': {'ECC': {'ECDSA': {'ECDSA': 1}, 'ECC': {'ECC': 4}}, 'FF': {'DH': {'Diffie-Hellman': 1}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA-256': 7, 'SHA-384': 3, 'SHA-512': 3}}}, 'crypto_scheme': {'MAC': {'MAC': 7}, 'KA': {'Key Agreement': 1}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 61, 'TLS 1.2': 1}}, 'PACE': {'PACE': 1}}, 'randomness': {}, 'cipher_mode': {'CBC': {'CBC': 2}, 'GCM': {'GCM': 2}, 'XTS': {'XTS': 1}}, 'ecc_curve': {'NIST': {'P-256': 2, 'P-384': 2, 'NIST P-256': 2, 'NIST P-384': 2}}, 'crypto_engine': {}, 'tls_cipher_suite': {'TLS': {'TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256': 2, 'TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384': 2, 'TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256': 2, 'TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384': 2}}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'FI': {'physical tampering': 3, 'malfunction': 2}}, 'technical_report_id': {'BSI': {'BSI TR-02102': 1, 'BSI TR-03109': 1, 'BSI TR-03109-1': 7, 'BSI TR-03109-2': 1, 'BSI TR-03109-3': 1, 'BSI TR-03109-4': 1, 'BSI TR-03109-6': 1, 'BSI TR-03111': 1, 'BSI TR-03116-3': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS 140-3': 1, 'FIPS 180-4': 1, 'FIPS 197': 1}, 'RFC': {'RFC 5246': 12, 'RFC 2104': 4, 'RFC 5639': 8, 'RFC 5114': 6, 'RFC 5289': 4, 'RFC 3565': 3, 'RFC 4493': 5, 'RFC 5084': 3, 'RFC 5652': 4, 'RFC 3394': 3, 'RFC 7616': 3, 'RFC 2616': 3, 'RFC 5083': 2}, 'ISO': {'ISO/IEC 10116:2006': 1}, 'X509': {'X.509': 4}, 'CC': {'CCMB-2017-04-001': 1, 'CCMB-2017-04-002': 1, 'CCMB-2017-04-003': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}
. - The cert_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-0831-V4-2021': 1}}, 'cc_protection_profile_id': {}, 'cc_security_level': {'EAL': {'EAL 4': 2, 'EAL 5': 1, 'EAL 2': 1, 'EAL 4 augmented': 1}}, 'cc_sar': {'ALC': {'ALC_FLR.2': 1, 'ALC_FLR': 1}, 'AVA': {'AVA_VAN.5': 1}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {}, 'asymmetric_crypto': {}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'ISO': {'ISO/IEC 15408': 2, 'ISO/IEC 18045': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}
. - The report_filename property was set to
0831V4a_pdf.pdf
. - The st_filename property was set to
0831V4b_pdf.pdf
. - The cert_filename property was set to
0831V4c_pdf.pdf
.
The computed heuristics were updated.
- The cert_lab property was set to
['BSI']
. - The cert_id property was set to
BSI-DSZ-CC-0831-V4-2021
. - The report_references property was updated, with the
{'directly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0831-V5-2022', 'BSI-DSZ-CC-0831-V6-2023']}, 'indirectly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0831-V6-2023', 'BSI-DSZ-CC-0831-V5-2022', 'BSI-DSZ-CC-0831-V7-2023']}, 'directly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0957-V2-2016', 'BSI-DSZ-CC-0831-V3-2021']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0666-2012', 'BSI-DSZ-CC-0957-2015', 'BSI-DSZ-CC-0978-2016', 'BSI-DSZ-CC-0845-2012', 'BSI-DSZ-CC-0845-V2-2013', 'BSI-DSZ-CC-0831-V2-2020', 'BSI-DSZ-CC-0831-2018', 'BSI-DSZ-CC-0957-V2-2016', 'BSI-DSZ-CC-0831-V3-2021']}}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]}
values added.
- The report property was updated, with the
-
17.08.2024 The certificate data changed.
Certificate changed
The report_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4a_pdf.pdf
.
The st_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4b_pdf.pdf
.
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data. - The st property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data. - The cert property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
None
. - The st_metadata property was set to
None
. - The cert_metadata property was set to
None
. - The report_frontpage property was set to
None
. - The report_keywords property was set to
None
. - The st_keywords property was set to
None
. - The cert_keywords property was set to
None
. - The report_filename property was set to
None
. - The st_filename property was set to
None
. - The cert_filename property was set to
None
.
The computed heuristics were updated.
- The cert_lab property was set to
None
. - The cert_id property was set to
None
. - The report_references property was updated, with the
{'directly_referencing': None, 'indirectly_referencing': None}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]}
values discarded.
- The new value is
-
12.08.2024 The certificate data changed.
Certificate changed
The Maintenance Updates of the certificate were updated.
- The following values were added:
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.cc.CCCertificate.MaintenanceReport', 'maintenance_date': '2024-06-27', 'maintenance_title': 'SMGW, Version 1.2, Version 1.2.1 and Version 1.2.2', 'maintenance_report_link': 'https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ma4a_pdf.pdf', 'maintenance_st_link': None}]}
.
The computed heuristics were updated.
- The report_references property was updated, with the
{'directly_referenced_by': None, 'indirectly_referenced_by': None, 'indirectly_referencing': {'__discard__': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0666-2012', 'BSI-DSZ-CC-0957-2015', 'BSI-DSZ-CC-0845-V2-2013', 'BSI-DSZ-CC-0845-2012']}}}
data.
- The following values were added:
-
31.07.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was updated, with the
{'enhanced': {'__update__': {'entries': {'__insert__': [[0, {'id': 'BSI-DSZ-CC-0831-V7-2023-MA-01', 'description': 'Maintenance Report'}], [5, {'id': 'BSI-DSZ-CC-0831-V6-2023-MA-01', 'description': 'Maintenance Report'}], [10, {'id': 'BSI-DSZ-CC-0831-V4-2021-MA-04', 'description': 'Maintenance Report'}]]}}}}
data.
- The scheme_data property was updated, with the
-
23.07.2024 The certificate was first processed.
New certificate
A new Common Criteria certificate with the product name SMGW Version 1.2 was processed.
Raw data
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "Other Devices and Systems",
"cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4c_pdf.pdf",
"dgst": "2bf7105ef1939208",
"heuristics": {
"_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
"annotated_references": null,
"cert_id": "BSI-DSZ-CC-0831-V4-2021",
"cert_lab": [
"BSI"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMC",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_INT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_FLR",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DEL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_IMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_OPE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_REQ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_LCD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_CCL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_FUN",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COV",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_TSS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"1.2"
]
},
"indirect_transitive_cves": null,
"next_certificates": [
"BSI-DSZ-CC-0831-V5-2022",
"BSI-DSZ-CC-0831-V6-2023",
"BSI-DSZ-CC-0831-V7-2023",
"BSI-DSZ-CC-0831-V8-2024",
"BSI-DSZ-CC-0831-V9-2024"
],
"prev_certificates": [
"BSI-DSZ-CC-0831-2018",
"BSI-DSZ-CC-0831-V2-2020",
"BSI-DSZ-CC-0831-V3-2021"
],
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0831-V6-2023",
"BSI-DSZ-CC-0831-V5-2022"
]
},
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0957-V2-2016",
"BSI-DSZ-CC-0831-V3-2021"
]
},
"indirectly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0831-V8-2024",
"BSI-DSZ-CC-0831-V6-2023",
"BSI-DSZ-CC-0831-V7-2023",
"BSI-DSZ-CC-0831-V9-2024",
"BSI-DSZ-CC-0831-V5-2022"
]
},
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0978-2016",
"BSI-DSZ-CC-0831-2018",
"BSI-DSZ-CC-0831-V2-2020",
"BSI-DSZ-CC-0957-V2-2016",
"BSI-DSZ-CC-0957-2015",
"BSI-DSZ-CC-0845-2012",
"BSI-DSZ-CC-0831-V3-2021",
"BSI-DSZ-CC-0845-V2-2013",
"BSI-DSZ-CC-0666-2012"
]
}
},
"scheme_data": null,
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": null,
"indirectly_referenced_by": null,
"indirectly_referencing": null
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2021-12-15",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ma1a_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMGW, Version 1.2.1"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2024-06-27",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ma4a_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMGW, Version 1.2, Version 1.2.1 and Version 1.2.2"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2022-02-15",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ma1a_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMGW, Version 1.2.2"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2022-03-04",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ma3_pdf.pdf",
"maintenance_st_link": null,
"maintenance_title": "SMGW, Version 1.2"
},
{
"_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
"maintenance_date": "2023-09-04",
"maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ra01a_pdf.pdf",
"maintenance_st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4ra01b_pdf.pdf",
"maintenance_title": "SMGW, Version 1.2SMGW, Version 1.2.1SMGW, Version 1.2.2"
}
]
},
"manufacturer": "Power Plus Communications AG",
"manufacturer_web": "https://ppc-ag.de",
"name": "SMGW Version 1.2",
"not_valid_after": "2029-09-05",
"not_valid_before": "2021-09-05",
"pdf_data": {
"_type": "sec_certs.sample.cc.CCCertificate.PdfData",
"cert_filename": "0831V4c_pdf.pdf",
"cert_frontpage": null,
"cert_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0831-V4-2021": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {},
"cc_sar": {
"ALC": {
"ALC_FLR": 1,
"ALC_FLR.2": 1
},
"AVA": {
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 2": 1,
"EAL 4": 2,
"EAL 4 augmented": 1,
"EAL 5": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"ISO": {
"ISO/IEC 15408": 2,
"ISO/IEC 18045": 2
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"cert_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20210910114419+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Smart Metering, Smart Grid\"",
"/ModDate": "D:20210913105516+02\u002700\u0027",
"/Producer": "LibreOffice 6.3",
"/Subject": "Zertifizierungsverfahren SMGW Version 1.2",
"/Title": "Certificate BSI-DSZ-CC-0831-V4-2021",
"pdf_file_size_bytes": 374477,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 1
},
"report_filename": "0831V4a_pdf.pdf",
"report_frontpage": {
"DE": {
"cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2",
"cc_version": "PP conformant Common Criteria Part 2 extended",
"cert_id": "BSI-DSZ-CC-0831-V4-2021",
"cert_item": "SMGW Version 1.2",
"cert_lab": "BSI",
"developer": "Power Plus Communications AG",
"match_rules": [
"(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
],
"ref_protection_profiles": "Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014"
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 2
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0831-V3-2021": 3,
"BSI-DSZ-CC-0831-V4-2021": 13,
"BSI-DSZ-CC-0957-V2-2016": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0073-2014": 3
}
},
"cc_sar": {
"ALC": {
"ALC_FLR": 3,
"ALC_FLR.2": 4
},
"AVA": {
"AVA_VAN.5": 5
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 2": 2,
"EAL 2+": 1,
"EAL 4": 8,
"EAL 4 augmented": 3,
"EAL 5": 3,
"EAL 5+": 1,
"EAL 6": 1
}
},
"cc_sfr": {},
"certification_process": {
"ConfidentialDocument": {
"AG [7] Evaluation Technical Report, Version 2, 2021-07-27, T\u00dcV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014": 1,
"Configuration list for the TOE, Version 153, 2021-06-30, EVG-CM-List, Power Plus Communications AG (confidential document) [10] Handbuch f\u00fcr Verbraucher, Smart Meter Gateway, Version 4.6, 2021-06-10 [11] Handbuch f\u00fcr": 1,
"being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1
}
},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"SSH": {
"SSH": 1
},
"TLS": {
"TLS": {
"TLS": 5
}
}
},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"TUV": {
"T\u00dcV Informationstechnik": 3
}
},
"hash_function": {
"SHA": {
"SHA2": {
"SHA-256": 1,
"SHA-384": 1,
"SHA-512": 1,
"SHA2": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {
"FI": {
"physical tampering": 1
}
},
"standard_id": {
"BSI": {
"AIS 1": 1,
"AIS 32": 1,
"AIS 34": 2,
"AIS 38": 1,
"AIS 46": 2,
"AIS 48": 1
},
"FIPS": {
"FIPS180-4": 3
},
"ISO": {
"ISO/IEC 15408": 4,
"ISO/IEC 17065": 2,
"ISO/IEC 18045": 4
},
"RFC": {
"RFC2104": 2,
"RFC3565": 1,
"RFC4493": 3,
"RFC5084": 1,
"RFC5246": 4,
"RFC5288": 1,
"RFC5652": 2,
"RFC6033": 1
}
},
"symmetric_crypto": {
"constructions": {
"MAC": {
"CMAC": 3
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7148": 1,
"BSI TR-02102-1": 1,
"BSI TR-03109-1": 1,
"BSI TR-03116-3": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20210910114419+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Smart Metering, Smart Grid\"",
"/ModDate": "D:20210910133736+02\u002700\u0027",
"/Producer": "LibreOffice 6.3",
"/Title": "Certification Report BSI-DSZ-CC-0831-V4-2021",
"pdf_file_size_bytes": 718909,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"https://www.sogis.eu/",
"https://www.bsi.bund.de/",
"https://www.bsi.bund.de/zertifizierung",
"http://www.commoncriteriaportal.org/",
"https://www.bsi.bund.de/zertifizierungsreporte",
"https://www.bsi.bund.de/AIS",
"http://www.commoncriteriaportal.org/cc/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 24
},
"st_filename": "0831V4b_pdf.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 4
},
"ECDSA": {
"ECDSA": 1
}
},
"FF": {
"DH": {
"Diffie-Hellman": 1
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0831-": 1,
"BSI-DSZ-CC-0831-V4-2021": 1
}
},
"cc_claims": {
"OE": {
"OE.SM": 4
},
"OSP": {
"OSP.SM": 5
}
},
"cc_protection_profile_id": {},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_IMP.1": 1
},
"AGD": {
"AGD_GWA": 2,
"AGD_OPE.1": 1,
"AGD_SEC": 3
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_DEL.1": 1,
"ALC_FLR.2": 6,
"ALC_LCD.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_INT.1": 1,
"ASE_REQ.2": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_FUN.1": 1
},
"AVA": {
"AVA_VAN.5": 7
}
},
"cc_security_level": {
"EAL": {
"EAL 2609": 1,
"EAL 4": 3,
"EAL 4 augmented": 1,
"EAL 4+": 1,
"EAL4": 1,
"EAL4 augmented": 1
}
},
"cc_sfr": {
"FAU": {
"FAU_ARP": 10,
"FAU_ARP.1": 1,
"FAU_GEN": 37,
"FAU_GEN.1": 17,
"FAU_GEN.2": 8,
"FAU_GEN.2.1": 1,
"FAU_SAA": 10,
"FAU_SAA.1": 3,
"FAU_SAA.1.1": 1,
"FAU_SAR": 28,
"FAU_SAR.1": 7,
"FAU_STG": 29,
"FAU_STG.1": 7,
"FAU_STG.2": 13,
"FAU_STG.2.1": 1,
"FAU_STG.2.2": 1,
"FAU_STG.2.3": 1,
"FAU_STG.3": 3,
"FAU_STG.4": 3
},
"FCO": {
"FCO_NRO": 3,
"FCO_NRO.1": 1,
"FCO_NRO.2": 10,
"FCO_NRO.2.1": 1,
"FCO_NRO.2.2": 1,
"FCO_NRO.2.3": 1
},
"FCS": {
"FCS_CKM": 41,
"FCS_CKM.1": 17,
"FCS_CKM.2": 6,
"FCS_CKM.4": 33,
"FCS_CKM.4.1": 1,
"FCS_COP": 58,
"FCS_COP.1": 11
},
"FDP": {
"FDP_ACC": 2,
"FDP_ACC.1": 9,
"FDP_ACC.2": 10,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 1,
"FDP_ACF.1": 9,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_IFC": 27,
"FDP_IFC.1": 12,
"FDP_IFC.2": 4,
"FDP_IFF": 22,
"FDP_IFF.1": 19,
"FDP_IFF.1.3": 1,
"FDP_ITC.1": 12,
"FDP_ITC.2": 12,
"FDP_RIP": 2,
"FDP_RIP.1": 1,
"FDP_RIP.2": 9,
"FDP_RIP.2.1": 1,
"FDP_SDI": 2,
"FDP_SDI.1": 1,
"FDP_SDI.2": 8,
"FDP_SDI.2.1": 1,
"FDP_SDI.2.2": 1
},
"FIA": {
"FIA_AFL": 3,
"FIA_AFL.1": 7,
"FIA_AFL.1.1": 1,
"FIA_AFL.1.2": 1,
"FIA_ATD": 3,
"FIA_ATD.1": 12,
"FIA_ATD.1.1": 1,
"FIA_UAU": 5,
"FIA_UAU.1": 2,
"FIA_UAU.2": 7,
"FIA_UAU.2.1": 1,
"FIA_UAU.5": 6,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 2,
"FIA_UAU.6": 7,
"FIA_UAU.6.1": 1,
"FIA_UID": 3,
"FIA_UID.1": 8,
"FIA_UID.2": 11,
"FIA_UID.2.1": 1,
"FIA_USB": 3,
"FIA_USB.1": 11,
"FIA_USB.1.1": 1,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_MOF": 2,
"FMT_MOF.1": 9,
"FMT_MOF.1.1": 1,
"FMT_MSA": 55,
"FMT_MSA.1": 9,
"FMT_MSA.3": 12,
"FMT_SMF": 2,
"FMT_SMF.1": 18,
"FMT_SMF.1.1": 1,
"FMT_SMR": 3,
"FMT_SMR.1": 28,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPR": {
"FPR_CON": 6,
"FPR_CON.1": 10,
"FPR_CON.1.1": 2,
"FPR_CON.1.2": 4,
"FPR_PSE": 2,
"FPR_PSE.1": 8,
"FPR_PSE.1.1": 1,
"FPR_PSE.1.2": 1,
"FPR_PSE.1.3": 1
},
"FPT": {
"FPT_FLS": 3,
"FPT_FLS.1": 8,
"FPT_FLS.1.1": 1,
"FPT_PHP": 3,
"FPT_PHP.1": 7,
"FPT_PHP.1.1": 1,
"FPT_PHP.1.2": 1,
"FPT_RPL": 3,
"FPT_RPL.1": 10,
"FPT_RPL.1.1": 1,
"FPT_RPL.1.2": 1,
"FPT_STM": 3,
"FPT_STM.1": 17,
"FPT_STM.1.1": 1,
"FPT_TST": 3,
"FPT_TST.1": 9,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ITC": 27,
"FTP_ITC.1": 9
}
},
"certification_process": {},
"cipher_mode": {
"CBC": {
"CBC": 2
},
"GCM": {
"GCM": 2
},
"XTS": {
"XTS": 1
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 1
},
"TLS": {
"TLS": {
"TLS": 61,
"TLS 1.2": 1
}
}
},
"crypto_scheme": {
"KA": {
"Key Agreement": 1
},
"MAC": {
"MAC": 7
}
},
"device_model": {},
"ecc_curve": {
"NIST": {
"NIST P-256": 2,
"NIST P-384": 2,
"P-256": 2,
"P-384": 2
}
},
"eval_facility": {},
"hash_function": {
"SHA": {
"SHA2": {
"SHA-256": 7,
"SHA-384": 3,
"SHA-512": 3
}
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {
"FI": {
"malfunction": 2,
"physical tampering": 3
}
},
"standard_id": {
"CC": {
"CCMB-2017-04-001": 1,
"CCMB-2017-04-002": 1,
"CCMB-2017-04-003": 1
},
"FIPS": {
"FIPS 140-3": 1,
"FIPS 180-4": 1,
"FIPS 197": 1
},
"ISO": {
"ISO/IEC 10116:2006": 1
},
"RFC": {
"RFC 2104": 4,
"RFC 2616": 3,
"RFC 3394": 3,
"RFC 3565": 3,
"RFC 4493": 5,
"RFC 5083": 2,
"RFC 5084": 3,
"RFC 5114": 6,
"RFC 5246": 12,
"RFC 5289": 4,
"RFC 5639": 8,
"RFC 5652": 4,
"RFC 7616": 3
},
"X509": {
"X.509": 4
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 14,
"AES-": 1
}
},
"constructions": {
"MAC": {
"CMAC": 10
}
}
},
"technical_report_id": {
"BSI": {
"BSI TR-02102": 1,
"BSI TR-03109": 1,
"BSI TR-03109-1": 7,
"BSI TR-03109-2": 1,
"BSI TR-03109-3": 1,
"BSI TR-03109-4": 1,
"BSI TR-03109-6": 1,
"BSI TR-03111": 1,
"BSI TR-03116-3": 1
}
},
"tee_name": {},
"tls_cipher_suite": {
"TLS": {
"TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256": 2,
"TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256": 2,
"TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384": 2,
"TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384": 2
}
},
"vendor": {},
"vulnerability": {}
},
"st_metadata": {
"/CreationDate": "D:20210901124429+02\u002700\u0027",
"/ModDate": "D:20210901124429+02\u002700\u0027",
"pdf_file_size_bytes": 1273907,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"http://csrc.nist.gov/publications/nistpubs/800-38D/SP-800-38D.pdf",
"http://www.ietf.org/rfc/rfc5652.txt",
"http://rfc-editor.org/rfc/rfc2616.txt",
"http://de.wikipedia.org/wiki/Ethernet",
"http://rfc-editor.org/rfc/rfc3394.txt",
"http://rfc-editor.org/rfc/rfc2104.txt",
"http://www.usb.org/developers/docs/usb20_docs/%23usb20spec",
"http://www.ppc-ag.com/",
"http://www.ietf.org/rfc/rfc5289.txt",
"http://fc12.ifca.ai/pre-proceedings/paper_49.pdf",
"http://www.ietf.org/rfc/rfc5084.txt",
"http://www.ietf.org/rfc/rfc5246.txt",
"http://en.wikipedia.org/wiki/Network_interface_device",
"http://de.wikipedia.org/wiki/Open_Metering_System",
"http://rfc-editor.org/rfc/rfc7616.txt",
"http://www.rfc-editor.org/rfc/rfc4493.txt",
"http://www.ietf.org/rfc/rfc5083.txt",
"http://www.ietf.org/rfc/rfc5639.txt",
"http://rfc-editor.org/rfc/rfc3565.txt",
"http://www.ietf.org/rfc/rfc5114.txt"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 173
}
},
"protection_profiles": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.protection_profile.ProtectionProfile",
"pp_eal": "EAL4+",
"pp_ids": {
"_type": "Set",
"elements": [
"SMARTMETERGATEWAYPP_V1.3"
]
},
"pp_link": "https://www.commoncriteriaportal.org/files/ppfiles/pp0073b_pdf.pdf",
"pp_name": "Protection Profile for the Gateway of a Smart Metering System"
}
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"AVA_VAN.5",
"ALC_FLR.2",
"EAL4+"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0831V4b_pdf.pdf",
"state": {
"_type": "sec_certs.sample.cc.CCCertificate.InternalState",
"cert": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "f5cbd6587f98f3561c8b0ce7032634dd983b9bfac70fc06f086bd35d76671e76",
"txt_hash": "059f2f0b58105a2bf5fdbd3eeea7818db95e6c0fef857c5b9f36691edba3322c"
},
"report": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "c06275697885e8fec86c0bd89eaa8ea4aeb7fbf331000c2301676101afd39e67",
"txt_hash": "5f64fc23ad7ebb444001db5a4b8d328d51f47011b6ed44433d4b8b19e95add88"
},
"st": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "fb342a544f5df30e74cefe44c737dbd79eb2a58e830492515c67cab34517abb8",
"txt_hash": "ecb50cc9ce982334178e8dbceb6dc4efd0d68b11ce344f2ca684448a460f6814"
}
},
"status": "active"
}