Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A

CSV information ?

Status archived
Valid from 12.06.2012
Valid until 01.09.2019
Scheme 🇫🇷 FR
Manufacturer Inside Secure
Category ICs, Smart Cards and Smart Card-Related Devices and Systems
Security level EAL5+, AVA_VAN.5, ALC_DVS.2
Protection profiles
Maintenance updates Rapport de maintenance ANSSI-CC-2012/21-M01 (16.05.2013) Certification report

Heuristics summary ?

Certificate ID: ANSSI-CC-2012/21

Certificate ?

Certification report ?

Extracted keywords

Symmetric Algorithms
AES, DES, TDES
Asymmetric Algorithms
ECDSA, ECC
Hash functions
SHA-1, SHA-224, SHA-384, SHA-512
Randomness
TRNG

Security level
EAL 5, EAL4, EAL7, EAL 1, EAL 3, EAL 7, ITSEC E6 Elevé
Security Assurance Requirements (SAR)
ADV_ARC, ADV_FSP, ADV_IMP, ADV_INT, ADV_TDS, AGD_OPE, AGD_PRE, ALC_DVS.2, ALC_FLR, ALC_CMC, ALC_CMS, ALC_DEL, ALC_DVS, ALC_LCD, ALC_TAT, ATE_COV, ATE_DPT, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VAN, ASE_CCL, ASE_ECD, ASE_INT, ASE_OBJ, ASE_REQ, ASE_SPD, ASE_TSS
Protection profiles
BSI-PP-0035-2007
Certificates
ANSSI-CC-2012/21
Evaluation facilities
Serma Technologies

Standards
AIS 31, AIS31, CCMB-2009-07-001, CCMB-2009-07-002, CCMB-2009-07-003, CCMB-2009-07-004

File metadata

Creation date D:20120614103158+02'00'
Modification date D:20120618194639+02'00'
Pages 18
Creator PScript5.dll Version 5.2
Producer Acrobat Distiller 8.1.0 (Windows)

Frontpage

Certificate ID ANSSI-CC-2012/21
Certified item Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A
Certification lab Serma Technologies 30 avenue Gustave Eiffel, 33608 Pessac, France
Developer Inside Secure Maxwell Building – Scottish Enterprise Technology Park East Kilbride – Glasgow G75 0QF - Ecosse Tél : +44 1355 356668 Commanditaire Inside Secure Maxwell Building – Scottish Enterprise Technology Park East Kilbride – Glasgow G75 0QF - Ecosse Tél : +44 1355 356668

Security target ?

Extracted keywords

Symmetric Algorithms
AES, DES, TDES
Asymmetric Algorithms
ECDH, ECDSA, ECC, DSA
Hash functions
SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
Randomness
TRNG, RND, RNG

Security level
EAL5, EAL4, EAL5+, EAL4+
Claims
O.RND, T.RND
Security Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.5, ADV_IMP.1, ADV_INT.2, ADV_TDS.4, AGD_OPE.1, AGD_PRE.1, ALC_DVS.2, ALC_CMC.4, ALC_CMS.5, ALC_DEL.1, ALC_LCD.1, ALC_TAT.2, ATE_COV.2, ATE_DPT.3, ATE_FUN.1, ATE_IND.2, AVA_VAN, AVA_VAN.5, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1
Security Functional Requirements (SFR)
FAU_SAS.1, FAU_SAS.1.1, FCS_COP.1, FCS_RNG.1, FCS_RNG.1.1, FCS_RNG.1.2, FCS_COP, FCS_COP.1.1, FCS_CKM.1, FCS_CKM.4, FDP_ITT.1, FDP_IFC.1, FDP_ITT.1.1, FDP_ACC.1, FDP_IFC.1.1, FDP_IFF.1, FDP_ITC.1, FDP_ITC.2, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FPT_FLS.1, FPT_ITT.1, FPT_PHP.3, FPT_FLS.1.1, FPT_PHP.3.1, FPT_ITT.1.1, FPT_AMT.1, FRU_FLT.2, FRU_FLT.1, FRU_FLT.2.1
Protection profiles
BSI-PP-0035
Evaluation facilities
SERMA

Side-channel analysis
Leak-Inherent, physical probing, side channel, Malfunction, malfunction, JHAS

Standards
FIPS PUB 46-3, FIPS 197, FIPS 180-2, FIPS 186-3, PKCS#1, AIS31, ISO/IEC 3309

File metadata

Title AT90SC28880RCV / AT90SC28848RCV Security Target Lite
Subject Security Target Lite
Keywords AT90SC28880RCV / AT90SC28848RCV Security Target Lite
Author John Boggie
Creation date D:20120410105928Z
Modification date D:20120410111357+01'00'
Pages 70
Creator PScript5.dll Version 5.2.2
Producer GPL Ghostscript 8.15

Heuristics ?

Certificate ID: ANSSI-CC-2012/21

Extracted SARs

ADV_ARC.1, ADV_FSP.5, ADV_IMP.1, ADV_INT.2, ADV_TDS.4, AGD_OPE.1, AGD_PRE.1, ALC_CMC.4, ALC_CMS.5, ALC_DEL.1, ALC_DVS.2, ALC_LCD.1, ALC_TAT.2, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1, ATE_COV.2, ATE_DPT.3, ATE_FUN.1, ATE_IND.2, AVA_VAN.5

References ?

No references are available for this certificate.

Updates ?

  • 10.02.2025 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to None.
  • 05.02.2025 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The report property was updated, with the {'_type': 'sec_certs.sample.document_state.DocumentState'} data.
    • The st property was updated, with the {'_type': 'sec_certs.sample.document_state.DocumentState'} data.
    • The cert property was updated, with the {'_type': 'sec_certs.sample.document_state.DocumentState'} data.

    The computed heuristics were updated.

    • The following values were inserted: {'protection_profiles': {'_type': 'Set', 'elements': ['f6d23054061d72ba']}, 'eal': 'EAL5+'}.
    • The prev_certificates property was set to None.
    • The next_certificates property was set to None.
    • The scheme_data property was set to {'product': 'Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A', 'url': 'https://cyber.gouv.fr/produits-certifies/microcontroleur-risc-at90sc28880rcv-at90sc28848rcv-rev', 'description': 'Le produit certifié est le « Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A » développé par Inside Secure. Pour des raisons commerciales, ce produit est vendu sous les deux références AT90SC28880RCV et AT90SC28848RCV, la différence entre les deux réside uniquement dans la taille de mémoire proposée. Le microcontrôleur seul n'est pas un produit utilisable en tant que tel. Il est', 'sponsor': 'Inside Secure', 'developer': 'Inside Secure', 'cert_id': 'ANSSI-CC-2012/21', 'level': 'EAL5+', 'enhanced': {'cert_id': 'ANSSI-CC-2012/21', 'certification_date': '2012-06-12', 'category': 'Micro-circuits', 'cc_version': 'Critères Communs version 3.1r3', 'developer': 'Inside Secure', 'sponsor': 'Inside Secure', 'evaluation_facility': 'Serma Technologies', 'level': 'EAL5+', 'protection_profile': 'PP0035', 'mutual_recognition': 'SOG-IS CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2012-21en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2012-21fr.pdf'}}.
  • 03.02.2025 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to None.
  • 27.01.2025 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to {'product': 'Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A', 'url': 'https://cyber.gouv.fr/produits-certifies/microcontroleur-risc-at90sc28880rcv-at90sc28848rcv-rev', 'description': 'Le produit certifié est le « Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A » développé par Inside Secure. Pour des raisons commerciales, ce produit est vendu sous les deux références AT90SC28880RCV et AT90SC28848RCV, la différence entre les deux réside uniquement dans la taille de mémoire proposée. Le microcontrôleur seul n'est pas un produit utilisable en tant que tel. Il est', 'sponsor': 'Inside Secure', 'developer': 'Inside Secure', 'cert_id': 'ANSSI-CC-2012/21', 'level': 'EAL5+', 'enhanced': {'cert_id': 'ANSSI-CC-2012/21', 'certification_date': '2012-06-12', 'category': 'Micro-circuits', 'cc_version': 'Critères Communs version 3.1r3', 'developer': 'Inside Secure', 'sponsor': 'Inside Secure', 'evaluation_facility': 'Serma Technologies', 'level': 'EAL5+', 'protection_profile': 'PP0035', 'mutual_recognition': 'SOG-IS CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2012-21en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2012-21fr.pdf'}}.
  • 06.01.2025 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to None.
  • 16.12.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to {'product': 'Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A', 'url': 'https://cyber.gouv.fr/produits-certifies/microcontroleur-risc-at90sc28880rcv-at90sc28848rcv-rev', 'description': 'Le produit certifié est le « Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A » développé par Inside Secure. Pour des raisons commerciales, ce produit est vendu sous les deux références AT90SC28880RCV et AT90SC28848RCV, la différence entre les deux réside uniquement dans la taille de mémoire proposée. Le microcontrôleur seul n'est pas un produit utilisable en tant que tel. Il est', 'sponsor': 'Inside Secure', 'developer': 'Inside Secure', 'cert_id': 'ANSSI-CC-2012/21', 'level': 'EAL5+', 'enhanced': {'cert_id': 'ANSSI-CC-2012/21', 'certification_date': '2012-06-12', 'category': 'Micro-circuits', 'cc_version': 'Critères Communs version 3.1r3', 'developer': 'Inside Secure', 'sponsor': 'Inside Secure', 'evaluation_facility': 'Serma Technologies', 'level': 'EAL5+', 'protection_profile': 'PP0035', 'mutual_recognition': 'SOG-IS CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2012-21en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2012-21fr.pdf'}}.
  • 09.12.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to None.
  • 21.11.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The following values were inserted: {'prev_certificates': [], 'next_certificates': []}.
  • 09.11.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was updated, with the {'description': 'Le produit certifié est le « Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A » développé par Inside Secure. Pour des raisons commerciales, ce produit est vendu sous les deux références AT90SC28880RCV et AT90SC28848RCV, la différence entre les deux réside uniquement dans la taille de mémoire proposée. Le microcontrôleur seul n'est pas un produit utilisable en tant que tel. Il est', 'cert_id': 'ANSSI-CC-2012/21', 'enhanced': {'__update__': {'cert_id': 'ANSSI-CC-2012/21', 'certification_date': '2012-06-12', 'mutual_recognition': 'SOG-IS CCRA'}}} data.
  • 17.10.2024 The certificate data changed.
    Certificate changed

    The Protection Profiles of the certificate were updated.

    • The new value is {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.protection_profile.ProtectionProfile', 'pp_name': 'Security IC Platform Protection Profile, Version 1.0', 'pp_eal': 'EAL4+', 'pp_link': 'https://www.commoncriteriaportal.org/files/ppfiles/pp0035b.pdf', 'pp_ids': {'_type': 'Set', 'elements': ['PKISKPP', 'SECURITY_IC_V1.0']}}]}.
  • 14.10.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to {'product': 'Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A', 'url': 'https://cyber.gouv.fr/produits-certifies/microcontroleur-risc-at90sc28880rcv-at90sc28848rcv-rev', 'description': 'Le produit certifié est le « Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A » développé par Inside Secure.\nPour des raisons commerciales, ce produit est vendu sous les deux références AT90SC28880RCV et AT90SC28848RCV, la différence entre les deux réside uniquement dans la taille de mémoire proposée.\nLe microcontrôleur seul n'est pas un produit utilisable en tant que tel. Il est', 'sponsor': 'Inside Secure', 'developer': 'Inside Secure', 'cert_id': '2012/21', 'level': 'EAL5+', 'enhanced': {'cert_id': '2012/21', 'certification_date': '12/06/2012', 'category': 'Micro-circuits', 'cc_version': 'Critères Communs version 3.1r3', 'developer': 'Inside Secure', 'sponsor': 'Inside Secure', 'evaluation_facility': 'Serma Technologies', 'level': 'EAL5+', 'protection_profile': 'PP0035', 'mutual_recognition': 'SOG-IS\n CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2012-21en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2012-21fr.pdf'}}.
  • 02.09.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to None.
  • 22.08.2024 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The report property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '34e056f77cda285c5334a04415c366a9476afddaeb5cba88e17ccc1a417266b5', 'txt_hash': 'ee865456a8038a144c9f872c099c1efec619ba1d34f9c5d1f10c61f3da1944f7'} data.
    • The st property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '1b770300771f15c9e93d2d4f6c7916e9a2d215205a8f06b491146f0dc6ab10b9', 'txt_hash': '0822a44adb17bf32e5482df7d0e17488eef1355f6e689fad30bff354ebbc5fa0'} data.

    The PDF extraction data was updated.

    • The report_metadata property was set to {'pdf_file_size_bytes': 276407, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 18, '/CreationDate': "D:20120614103158+02'00'", '/Creator': 'PScript5.dll Version 5.2', '/ModDate': "D:20120618194639+02'00'", '/Producer': 'Acrobat Distiller 8.1.0 (Windows)', '/Title': '', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}.
    • The st_metadata property was set to {'pdf_file_size_bytes': 961570, 'pdf_is_encrypted': True, 'pdf_number_of_pages': 70, '/Author': 'John Boggie', '/CreationDate': 'D:20120410105928Z', '/Creator': 'PScript5.dll Version 5.2.2', '/Keywords': 'AT90SC28880RCV / AT90SC28848RCV Security Target Lite', '/ModDate': "D:20120410111357+01'00'", '/Producer': 'GPL Ghostscript 8.15', '/Subject': 'Security Target Lite', '/Title': 'AT90SC28880RCV / AT90SC28848RCV Security Target Lite', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}.
    • The report_frontpage property was set to {'FR': {'match_rules': ['Référence du rapport de certification(.+)Nom du produit(.+)Référence/version du produit(.+)Conformité à un profil de protection(.+)Critères d’évaluation et version(.+)Niveau d’évaluation(.+)Développeur (.+)Centre d’évaluation(.+)Accords de reconnaissance applicables'], 'cert_id': 'ANSSI-CC-2012/21', 'cert_item': 'Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A', 'cert_item_version': 'Révision A pour le microcontrôleur versions 00.03.12.00 / 00.03.11.08 / 00.03.10.02 / 00.03.14.03 pour la librairie cryptographique logicielle', 'ref_protection_profiles': 'PP0035] : Security IC platform Protection Profile Version 1.0', 'cc_version': 'Critères Communs version 3.1 révision 3', 'cc_security_level': 'EAL 5 augmenté ALC_DVS.2, AVA_VAN.5', 'developer': 'Inside Secure Maxwell Building – Scottish Enterprise Technology Park East Kilbride – Glasgow G75 0QF - Ecosse Tél : +44 1355 356668 Commanditaire Inside Secure Maxwell Building – Scottish Enterprise Technology Park East Kilbride – Glasgow G75 0QF - Ecosse Tél : +44 1355 356668', 'cert_lab': 'Serma Technologies 30 avenue Gustave Eiffel, 33608 Pessac, France'}}.
    • The report_keywords property was set to {'cc_cert_id': {'FR': {'ANSSI-CC-2012/21': 19}}, 'cc_protection_profile_id': {'BSI': {'BSI-PP-0035-2007': 1}}, 'cc_security_level': {'EAL': {'EAL 5': 3, 'EAL4': 2, 'EAL7': 1, 'EAL 1': 1, 'EAL 3': 1, 'EAL 7': 1}, 'ITSEC': {'ITSEC E6 Elevé': 1}}, 'cc_sar': {'ADV': {'ADV_ARC': 1, 'ADV_FSP': 1, 'ADV_IMP': 1, 'ADV_INT': 1, 'ADV_TDS': 1}, 'AGD': {'AGD_OPE': 1, 'AGD_PRE': 1}, 'ALC': {'ALC_DVS.2': 1, 'ALC_FLR': 1, 'ALC_CMC': 1, 'ALC_CMS': 1, 'ALC_DEL': 1, 'ALC_DVS': 1, 'ALC_LCD': 1, 'ALC_TAT': 1}, 'ATE': {'ATE_COV': 1, 'ATE_DPT': 1, 'ATE_FUN': 1, 'ATE_IND': 1}, 'AVA': {'AVA_VAN.5': 1, 'AVA_VAN': 3}, 'ASE': {'ASE_CCL': 1, 'ASE_ECD': 1, 'ASE_INT': 1, 'ASE_OBJ': 1, 'ASE_REQ': 1, 'ASE_SPD': 1, 'ASE_TSS': 1}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {'Serma': {'Serma Technologies': 3}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 3}}, 'DES': {'DES': {'DES': 3}, '3DES': {'TDES': 1}}}, 'asymmetric_crypto': {'ECC': {'ECDSA': {'ECDSA': 2}, 'ECC': {'ECC': 1}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA1': {'SHA-1': 1}, 'SHA2': {'SHA-224': 1, 'SHA-384': 1, 'SHA-512': 1}}}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {'TRNG': {'TRNG': 2}}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'BSI': {'AIS 31': 1, 'AIS31': 2}, 'CC': {'CCMB-2009-07-001': 1, 'CCMB-2009-07-002': 1, 'CCMB-2009-07-003': 1, 'CCMB-2009-07-004': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}.
    • The st_keywords property was set to {'cc_cert_id': {}, 'cc_protection_profile_id': {'BSI': {'BSI-PP-0035': 4}}, 'cc_security_level': {'EAL': {'EAL5': 6, 'EAL4': 1, 'EAL5+': 1, 'EAL4+': 1}}, 'cc_sar': {'ADV': {'ADV_ARC.1': 5, 'ADV_FSP.5': 1, 'ADV_IMP.1': 1, 'ADV_INT.2': 1, 'ADV_TDS.4': 1}, 'AGD': {'AGD_OPE.1': 1, 'AGD_PRE.1': 1}, 'ALC': {'ALC_DVS.2': 3, 'ALC_CMC.4': 1, 'ALC_CMS.5': 1, 'ALC_DEL.1': 1, 'ALC_LCD.1': 1, 'ALC_TAT.2': 1}, 'ATE': {'ATE_COV.2': 1, 'ATE_DPT.3': 1, 'ATE_FUN.1': 1, 'ATE_IND.2': 1}, 'AVA': {'AVA_VAN': 1, 'AVA_VAN.5': 3}, 'ASE': {'ASE_CCL.1': 1, 'ASE_ECD.1': 1, 'ASE_INT.1': 1, 'ASE_OBJ.2': 1, 'ASE_REQ.2': 1, 'ASE_SPD.1': 1, 'ASE_TSS.1': 1}}, 'cc_sfr': {'FAU': {'FAU_SAS.1': 9, 'FAU_SAS.1.1': 1}, 'FCS': {'FCS_COP.1': 12, 'FCS_RNG.1': 10, 'FCS_RNG.1.1': 1, 'FCS_RNG.1.2': 1, 'FCS_COP': 13, 'FCS_COP.1.1': 13, 'FCS_CKM.1': 16, 'FCS_CKM.4': 15}, 'FDP': {'FDP_ITT.1': 12, 'FDP_IFC.1': 15, 'FDP_ITT.1.1': 1, 'FDP_ACC.1': 1, 'FDP_IFC.1.1': 1, 'FDP_IFF.1': 1, 'FDP_ITC.1': 15, 'FDP_ITC.2': 15}, 'FMT': {'FMT_LIM.1': 10, 'FMT_LIM.2': 9, 'FMT_LIM.1.1': 1, 'FMT_LIM.2.1': 1}, 'FPT': {'FPT_FLS.1': 13, 'FPT_ITT.1': 11, 'FPT_PHP.3': 12, 'FPT_FLS.1.1': 1, 'FPT_PHP.3.1': 1, 'FPT_ITT.1.1': 1, 'FPT_AMT.1': 1}, 'FRU': {'FRU_FLT.2': 12, 'FRU_FLT.1': 1, 'FRU_FLT.2.1': 1}}, 'cc_claims': {'O': {'O.RND': 4}, 'T': {'T.RND': 3}}, 'vendor': {}, 'eval_facility': {'Serma': {'SERMA': 1}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 14}}, 'DES': {'DES': {'DES': 15}, '3DES': {'TDES': 12}}}, 'asymmetric_crypto': {'ECC': {'ECDH': {'ECDH': 2}, 'ECDSA': {'ECDSA': 20}, 'ECC': {'ECC': 1}}, 'FF': {'DSA': {'DSA': 2}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA1': {'SHA-1': 5}, 'SHA2': {'SHA-224': 5, 'SHA-256': 4, 'SHA-384': 4, 'SHA-512': 3}}}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {'TRNG': {'TRNG': 1}, 'RNG': {'RND': 7, 'RNG': 1}}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'SCA': {'Leak-Inherent': 13, 'physical probing': 2, 'side channel': 1}, 'FI': {'Malfunction': 13, 'malfunction': 1}, 'other': {'JHAS': 1}}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS PUB 46-3': 1, 'FIPS 197': 1, 'FIPS 180-2': 5, 'FIPS 186-3': 2}, 'PKCS': {'PKCS#1': 2}, 'BSI': {'AIS31': 11}, 'ISO': {'ISO/IEC 3309': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}.
    • The report_filename property was set to ANSSI-CC_2012-21fr.pdf.
    • The st_filename property was set to ANSSI-CC-cible_2012-21en.pdf.

    The computed heuristics were updated.

    • The cert_lab property was set to ['SERMA'].
    • The cert_id property was set to ANSSI-CC-2012/21.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_IND', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_INT', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 5}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_PRE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 5}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}]} values added.
  • 17.08.2024 The certificate data changed.
    Certificate changed

    The report_link was updated.

    • The new value is https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC_2012-21fr.pdf.

    The st_link was updated.

    • The new value is https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC-cible_2012-21en.pdf.

    The state of the certificate object was updated.

    • The report property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.
    • The st property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.

    The PDF extraction data was updated.

    • The report_metadata property was set to None.
    • The st_metadata property was set to None.
    • The report_frontpage property was set to None.
    • The report_keywords property was set to None.
    • The st_keywords property was set to None.
    • The report_filename property was set to None.
    • The st_filename property was set to None.

    The computed heuristics were updated.

    • The cert_lab property was set to None.
    • The cert_id property was set to None.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_IND', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_INT', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 5}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_PRE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 5}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}]} values discarded.
  • 12.08.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to {'product': 'Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A', 'url': 'https://cyber.gouv.fr/produits-certifies/microcontroleur-risc-at90sc28880rcv-at90sc28848rcv-rev', 'description': 'Le produit certifié est le « Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A » développé par Inside Secure.\nPour des raisons commerciales, ce produit est vendu sous les deux références AT90SC28880RCV et AT90SC28848RCV, la différence entre les deux réside uniquement dans la taille de mémoire proposée.\nLe microcontrôleur seul n'est pas un produit utilisable en tant que tel. Il est', 'sponsor': 'Inside Secure', 'developer': 'Inside Secure', 'cert_id': '2012/21', 'level': 'EAL5+', 'enhanced': {'cert_id': '2012/21', 'certification_date': '12/06/2012', 'category': 'Micro-circuits', 'cc_version': 'Critères Communs version 3.1r3', 'developer': 'Inside Secure', 'sponsor': 'Inside Secure', 'evaluation_facility': 'Serma Technologies', 'level': 'EAL5+', 'protection_profile': 'PP0035', 'mutual_recognition': 'SOG-IS\n CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2012-21en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2012-21fr.pdf'}}.
  • 31.07.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was set to None.
  • 23.07.2024 The certificate was first processed.
    New certificate

    A new Common Criteria certificate with the product name Microcontrôleur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A was processed.

Raw data

{
  "_type": "sec_certs.sample.cc.CCCertificate",
  "category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
  "cert_link": null,
  "dgst": "f98675655635725b",
  "heuristics": {
    "_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
    "annotated_references": null,
    "cert_id": "ANSSI-CC-2012/21",
    "cert_lab": [
      "SERMA"
    ],
    "cpe_matches": null,
    "direct_transitive_cves": null,
    "eal": "EAL5+",
    "extracted_sars": {
      "_type": "Set",
      "elements": [
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_DEL",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_IMP",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_TAT",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_CMS",
          "level": 5
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_FUN",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_CMC",
          "level": 4
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_DPT",
          "level": 3
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_TDS",
          "level": 4
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_ARC",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_CCL",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_ECD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_DVS",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AVA_VAN",
          "level": 5
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_IND",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_INT",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_LCD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AGD_OPE",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AGD_PRE",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_COV",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_TSS",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_INT",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_REQ",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_SPD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_FSP",
          "level": 5
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_OBJ",
          "level": 2
        }
      ]
    },
    "extracted_versions": {
      "_type": "Set",
      "elements": [
        "-"
      ]
    },
    "indirect_transitive_cves": null,
    "next_certificates": null,
    "prev_certificates": null,
    "protection_profiles": {
      "_type": "Set",
      "elements": [
        "f6d23054061d72ba"
      ]
    },
    "related_cves": null,
    "report_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "scheme_data": null,
    "st_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "verified_cpe_matches": null
  },
  "maintenance_updates": {
    "_type": "Set",
    "elements": [
      {
        "_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
        "maintenance_date": "2013-05-16",
        "maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC-2012-21-M01fr.pdf",
        "maintenance_st_link": null,
        "maintenance_title": "Rapport de maintenance ANSSI-CC-2012/21-M01"
      }
    ]
  },
  "manufacturer": "Inside Secure",
  "manufacturer_web": "https://insidesecure.com",
  "name": "Microcontr\u00f4leur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A",
  "not_valid_after": "2019-09-01",
  "not_valid_before": "2012-06-12",
  "pdf_data": {
    "_type": "sec_certs.sample.cc.CCCertificate.PdfData",
    "cert_filename": null,
    "cert_frontpage": null,
    "cert_keywords": null,
    "cert_metadata": null,
    "report_filename": "ANSSI-CC_2012-21fr.pdf",
    "report_frontpage": {
      "FR": {
        "cc_security_level": "EAL 5 augment\u00e9 ALC_DVS.2, AVA_VAN.5",
        "cc_version": "Crit\u00e8res Communs version 3.1 r\u00e9vision 3",
        "cert_id": "ANSSI-CC-2012/21",
        "cert_item": "Microcontr\u00f4leur RISC AT90SC28880RCV / AT90SC28848RCV, Rev A",
        "cert_item_version": "R\u00e9vision A pour le microcontr\u00f4leur versions 00.03.12.00 / 00.03.11.08 / 00.03.10.02 / 00.03.14.03 pour la librairie cryptographique logicielle",
        "cert_lab": "Serma Technologies 30 avenue Gustave Eiffel, 33608 Pessac, France",
        "developer": "Inside Secure Maxwell Building \u2013 Scottish Enterprise Technology Park East Kilbride \u2013 Glasgow G75 0QF - Ecosse T\u00e9l : +44 1355 356668 Commanditaire Inside Secure Maxwell Building \u2013 Scottish Enterprise Technology Park East Kilbride \u2013 Glasgow G75 0QF - Ecosse T\u00e9l : +44 1355 356668",
        "match_rules": [
          "R\u00e9f\u00e9rence du rapport de certification(.+)Nom du produit(.+)R\u00e9f\u00e9rence/version du produit(.+)Conformit\u00e9 \u00e0 un profil de protection(.+)Crit\u00e8res d\u2019\u00e9valuation et version(.+)Niveau d\u2019\u00e9valuation(.+)D\u00e9veloppeur (.+)Centre d\u2019\u00e9valuation(.+)Accords de reconnaissance applicables"
        ],
        "ref_protection_profiles": "PP0035] : Security IC platform Protection Profile Version 1.0"
      }
    },
    "report_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 1
          },
          "ECDSA": {
            "ECDSA": 2
          }
        }
      },
      "cc_cert_id": {
        "FR": {
          "ANSSI-CC-2012/21": 19
        }
      },
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-PP-0035-2007": 1
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC": 1,
          "ADV_FSP": 1,
          "ADV_IMP": 1,
          "ADV_INT": 1,
          "ADV_TDS": 1
        },
        "AGD": {
          "AGD_OPE": 1,
          "AGD_PRE": 1
        },
        "ALC": {
          "ALC_CMC": 1,
          "ALC_CMS": 1,
          "ALC_DEL": 1,
          "ALC_DVS": 1,
          "ALC_DVS.2": 1,
          "ALC_FLR": 1,
          "ALC_LCD": 1,
          "ALC_TAT": 1
        },
        "ASE": {
          "ASE_CCL": 1,
          "ASE_ECD": 1,
          "ASE_INT": 1,
          "ASE_OBJ": 1,
          "ASE_REQ": 1,
          "ASE_SPD": 1,
          "ASE_TSS": 1
        },
        "ATE": {
          "ATE_COV": 1,
          "ATE_DPT": 1,
          "ATE_FUN": 1,
          "ATE_IND": 1
        },
        "AVA": {
          "AVA_VAN": 3,
          "AVA_VAN.5": 1
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 1": 1,
          "EAL 3": 1,
          "EAL 5": 3,
          "EAL 7": 1,
          "EAL4": 2,
          "EAL7": 1
        },
        "ITSEC": {
          "ITSEC E6 Elev\u00e9": 1
        }
      },
      "cc_sfr": {},
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {
        "Serma": {
          "Serma Technologies": 3
        }
      },
      "hash_function": {
        "SHA": {
          "SHA1": {
            "SHA-1": 1
          },
          "SHA2": {
            "SHA-224": 1,
            "SHA-384": 1,
            "SHA-512": 1
          }
        }
      },
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "TRNG": {
          "TRNG": 2
        }
      },
      "side_channel_analysis": {},
      "standard_id": {
        "BSI": {
          "AIS 31": 1,
          "AIS31": 2
        },
        "CC": {
          "CCMB-2009-07-001": 1,
          "CCMB-2009-07-002": 1,
          "CCMB-2009-07-003": 1,
          "CCMB-2009-07-004": 1
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 3
          }
        },
        "DES": {
          "3DES": {
            "TDES": 1
          },
          "DES": {
            "DES": 3
          }
        }
      },
      "technical_report_id": {},
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "report_metadata": {
      "/CreationDate": "D:20120614103158+02\u002700\u0027",
      "/Creator": "PScript5.dll Version 5.2",
      "/ModDate": "D:20120618194639+02\u002700\u0027",
      "/Producer": "Acrobat Distiller 8.1.0 (Windows)",
      "/Title": "",
      "pdf_file_size_bytes": 276407,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 18
    },
    "st_filename": "ANSSI-CC-cible_2012-21en.pdf",
    "st_frontpage": null,
    "st_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 1
          },
          "ECDH": {
            "ECDH": 2
          },
          "ECDSA": {
            "ECDSA": 20
          }
        },
        "FF": {
          "DSA": {
            "DSA": 2
          }
        }
      },
      "cc_cert_id": {},
      "cc_claims": {
        "O": {
          "O.RND": 4
        },
        "T": {
          "T.RND": 3
        }
      },
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-PP-0035": 4
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC.1": 5,
          "ADV_FSP.5": 1,
          "ADV_IMP.1": 1,
          "ADV_INT.2": 1,
          "ADV_TDS.4": 1
        },
        "AGD": {
          "AGD_OPE.1": 1,
          "AGD_PRE.1": 1
        },
        "ALC": {
          "ALC_CMC.4": 1,
          "ALC_CMS.5": 1,
          "ALC_DEL.1": 1,
          "ALC_DVS.2": 3,
          "ALC_LCD.1": 1,
          "ALC_TAT.2": 1
        },
        "ASE": {
          "ASE_CCL.1": 1,
          "ASE_ECD.1": 1,
          "ASE_INT.1": 1,
          "ASE_OBJ.2": 1,
          "ASE_REQ.2": 1,
          "ASE_SPD.1": 1,
          "ASE_TSS.1": 1
        },
        "ATE": {
          "ATE_COV.2": 1,
          "ATE_DPT.3": 1,
          "ATE_FUN.1": 1,
          "ATE_IND.2": 1
        },
        "AVA": {
          "AVA_VAN": 1,
          "AVA_VAN.5": 3
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL4": 1,
          "EAL4+": 1,
          "EAL5": 6,
          "EAL5+": 1
        }
      },
      "cc_sfr": {
        "FAU": {
          "FAU_SAS.1": 9,
          "FAU_SAS.1.1": 1
        },
        "FCS": {
          "FCS_CKM.1": 16,
          "FCS_CKM.4": 15,
          "FCS_COP": 13,
          "FCS_COP.1": 12,
          "FCS_COP.1.1": 13,
          "FCS_RNG.1": 10,
          "FCS_RNG.1.1": 1,
          "FCS_RNG.1.2": 1
        },
        "FDP": {
          "FDP_ACC.1": 1,
          "FDP_IFC.1": 15,
          "FDP_IFC.1.1": 1,
          "FDP_IFF.1": 1,
          "FDP_ITC.1": 15,
          "FDP_ITC.2": 15,
          "FDP_ITT.1": 12,
          "FDP_ITT.1.1": 1
        },
        "FMT": {
          "FMT_LIM.1": 10,
          "FMT_LIM.1.1": 1,
          "FMT_LIM.2": 9,
          "FMT_LIM.2.1": 1
        },
        "FPT": {
          "FPT_AMT.1": 1,
          "FPT_FLS.1": 13,
          "FPT_FLS.1.1": 1,
          "FPT_ITT.1": 11,
          "FPT_ITT.1.1": 1,
          "FPT_PHP.3": 12,
          "FPT_PHP.3.1": 1
        },
        "FRU": {
          "FRU_FLT.1": 1,
          "FRU_FLT.2": 12,
          "FRU_FLT.2.1": 1
        }
      },
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {
        "Serma": {
          "SERMA": 1
        }
      },
      "hash_function": {
        "SHA": {
          "SHA1": {
            "SHA-1": 5
          },
          "SHA2": {
            "SHA-224": 5,
            "SHA-256": 4,
            "SHA-384": 4,
            "SHA-512": 3
          }
        }
      },
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "RNG": {
          "RND": 7,
          "RNG": 1
        },
        "TRNG": {
          "TRNG": 1
        }
      },
      "side_channel_analysis": {
        "FI": {
          "Malfunction": 13,
          "malfunction": 1
        },
        "SCA": {
          "Leak-Inherent": 13,
          "physical probing": 2,
          "side channel": 1
        },
        "other": {
          "JHAS": 1
        }
      },
      "standard_id": {
        "BSI": {
          "AIS31": 11
        },
        "FIPS": {
          "FIPS 180-2": 5,
          "FIPS 186-3": 2,
          "FIPS 197": 1,
          "FIPS PUB 46-3": 1
        },
        "ISO": {
          "ISO/IEC 3309": 2
        },
        "PKCS": {
          "PKCS#1": 2
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 14
          }
        },
        "DES": {
          "3DES": {
            "TDES": 12
          },
          "DES": {
            "DES": 15
          }
        }
      },
      "technical_report_id": {},
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "st_metadata": {
      "/Author": "John Boggie",
      "/CreationDate": "D:20120410105928Z",
      "/Creator": "PScript5.dll Version 5.2.2",
      "/Keywords": "AT90SC28880RCV / AT90SC28848RCV Security Target Lite",
      "/ModDate": "D:20120410111357+01\u002700\u0027",
      "/Producer": "GPL Ghostscript 8.15",
      "/Subject": "Security Target Lite",
      "/Title": "AT90SC28880RCV / AT90SC28848RCV Security Target Lite",
      "pdf_file_size_bytes": 961570,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": true,
      "pdf_number_of_pages": 70
    }
  },
  "protection_profile_links": {
    "_type": "Set",
    "elements": [
      "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0035b.pdf"
    ]
  },
  "report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC_2012-21fr.pdf",
  "scheme": "FR",
  "security_level": {
    "_type": "Set",
    "elements": [
      "ALC_DVS.2",
      "EAL5+",
      "AVA_VAN.5"
    ]
  },
  "st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC-cible_2012-21en.pdf",
  "state": {
    "_type": "sec_certs.sample.cc.CCCertificate.InternalState",
    "cert": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_garbage": false,
      "convert_ok": false,
      "download_ok": false,
      "extract_ok": false,
      "pdf_hash": null,
      "txt_hash": null
    },
    "report": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "34e056f77cda285c5334a04415c366a9476afddaeb5cba88e17ccc1a417266b5",
      "txt_hash": "ee865456a8038a144c9f872c099c1efec619ba1d34f9c5d1f10c61f3da1944f7"
    },
    "st": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "1b770300771f15c9e93d2d4f6c7916e9a2d215205a8f06b491146f0dc6ab10b9",
      "txt_hash": "0822a44adb17bf32e5482df7d0e17488eef1355f6e689fad30bff354ebbc5fa0"
    }
  },
  "status": "archived"
}