name |
Sourcefire 3D System Version 5.2.0.1 |
SMARTY IQ-GPRS / LTE, Version 1.4 |
category |
Detection Devices and Systems |
Other Devices and Systems |
scheme |
US |
DE |
status |
archived |
active |
not_valid_after |
21.03.2016 |
19.12.2032 |
not_valid_before |
06.08.2014 |
20.12.2024 |
cert_link |
|
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6c_pdf.pdf |
report_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/st_vid10537-vr.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6a_pdf.pdf |
st_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/st_vid10537-st.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6b_pdf.pdf |
manufacturer |
Sourcefire Inc. |
Sagemcom Dr. Neuhaus GmbH |
manufacturer_web |
https://www.sourcefire.com/ |
https://sagemcom.com |
security_level |
{} |
EAL4+, ALC_FLR.2, AVA_VAN.5 |
dgst |
79f1b9da6ca5a71c |
4b7dcf610d994944 |
heuristics/cert_id |
CCEVS-VR-VID-10537-2014 |
BSI-DSZ-CC-0822-V6-2024 |
heuristics/cert_lab |
US |
BSI |
heuristics/cpe_matches |
{} |
{} |
heuristics/verified_cpe_matches |
{} |
{} |
heuristics/related_cves |
{} |
{} |
heuristics/direct_transitive_cves |
{} |
{} |
heuristics/indirect_transitive_cves |
{} |
{} |
heuristics/extracted_sars |
ADV_FSP.1, ALC_CMC.1, AVA_VAN.1, ATE_IND.1, ALC_CMS.1, AGD_OPE.1, AGD_PRE.1 |
ATE_COV.2, ASE_TSS.1, ASE_INT.1, ATE_FUN.1, AVA_VAN.5, ALC_DEL.1, ALC_LCD.1, ADV_ARC.1, AGD_OPE.1, ASE_REQ.2, ASE_CCL.1, ALC_CMC.4, ALC_FLR.2, ADV_IMP.1 |
heuristics/extracted_versions |
5.2.0.1 |
1.4 |
heuristics/prev_certificates |
{} |
{} |
heuristics/next_certificates |
{} |
{} |
heuristics/report_references/directly_referenced_by |
{} |
{} |
heuristics/report_references/directly_referencing |
{} |
BSI-DSZ-CC-0822-V5-2023 |
heuristics/report_references/indirectly_referenced_by |
{} |
{} |
heuristics/report_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0822-V2-2020, BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0822-V3-2021, BSI-DSZ-CC-0822-V5-2023 |
heuristics/scheme_data |
- category: Firewall, Wireless Monitoring
- certification_date: 06.08.2014
- evaluation_facility: COACT, Inc. Labs
- expiration_date: 06.08.2016
- id: CCEVS-VR-VID10537
- product: Sourcefire 3D System Version 5.2.0.1
- scheme: US
- url: https://www.niap-ccevs.org/product/10537
- vendor: Sourcefire, Inc.
|
- category: Intelligent measuring systems
- cert_id: BSI-DSZ-CC-0822-V6-2024
- certification_date: 20.12.2024
- enhanced:
- applicant: Sagemcom Dr. Neuhaus GmbH Papenreye 65 22453 Hamburg
- assurance_level: EAL4+,AVA_VAN.5,ALC_FLR.2
- cert_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6c_pdf.pdf?__blob=publicationFile&v=2
- certification_date: 20.12.2024
- entries: [frozendict({'id': 'BSI-DSZ-CC-0822-V6-2024', 'description': 'The focus of this recertification was on the introduction of a new LTE-Modul for WAN-communication, the GWA-change process implementation following FNN requirements and the introduction of proxy-profiles and communication scenario HKS3 with SOCKSv5.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V5-2023', 'description': 'components.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V4-2023', 'description': 'The focus of this recertification was on the update of the operating system and some libraries, the implementation of changed and added tariff use cases (TAF 2, TAF 9, TAF 10, TAF 14), the support of IPv6 and the support of firmware download.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-RA-02', 'description': 'The CC-certificate BSI-DSZ-CC-0822-V3-2021 remains valid for 2 further years.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-RA-01', 'description': 'Successful Re-Assessment with update of the vulnerability analysis.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-MA-02', 'description': 'Security Target'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-MA-01', 'description': 'version number remains the same as the alternative components have the same behaviour as the original one.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021', 'description': 'The previoulsly certified TOE was changed and re-certified to implement minor security-relevant optimizations.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V2-2020', 'description': 'Certificate'}), frozendict({'id': 'BSI-DSZ-CC-0822-2019-MA-01 (20.11.2019)', 'description': 'Certificate invalid'}), frozendict({'id': 'BSI-DSZ-CC-0822-2019 (25.09.2019)', 'description': 'Certificate invalid'})]
- evaluation_facility: TÜV Informationstechnik GmbH
- expiration_date: 19.12.2032
- product: SMARTY IQ-LTE, Version 1.4
- protection_profile: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI-CC-PP-0073-2014
- report_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6a_pdf.pdf?__blob=publicationFile&v=2
- target_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6b_pdf.html?nn=456626
- product: SMARTY IQ-LTE, Version 1.4
- subcategory: (Smart Meter Gateway)
- url: https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_Gateway/0822_0822V2_0822V3_0822V4_0822V5_0822V6.html
- vendor: Sagemcom Dr. Neuhaus GmbH
|
heuristics/st_references/directly_referenced_by |
{} |
{} |
heuristics/st_references/directly_referencing |
{} |
BSI-DSZ-CC-0957-V2-2016 |
heuristics/st_references/indirectly_referenced_by |
{} |
{} |
heuristics/st_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0957-V2-2016, BSI-DSZ-CC-0978-2016 |
heuristics/protection_profiles |
ac9abe3d5c5a31f0 |
6346b04de6859db3 |
maintenance_updates |
|
|
protection_profiles |
|
|
protection_profile_links |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp_nd_v1.1.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073b_pdf.pdf |
pdf_data/cert_filename |
|
0822V6c_pdf.pdf |
pdf_data/cert_frontpage |
|
|
pdf_data/cert_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0822-V6-2024: 1
|
pdf_data/cert_keywords/cc_protection_profile_id |
|
|
pdf_data/cert_keywords/cc_security_level |
|
- EAL:
- EAL 2: 1
- EAL 4: 2
- EAL 4 augmented: 1
- EAL 5: 1
|
pdf_data/cert_keywords/cc_sar |
|
|
pdf_data/cert_keywords/cc_sfr |
|
|
pdf_data/cert_keywords/cc_claims |
|
|
pdf_data/cert_keywords/vendor |
|
|
pdf_data/cert_keywords/eval_facility |
|
|
pdf_data/cert_keywords/symmetric_crypto |
|
|
pdf_data/cert_keywords/asymmetric_crypto |
|
|
pdf_data/cert_keywords/pq_crypto |
|
|
pdf_data/cert_keywords/hash_function |
|
|
pdf_data/cert_keywords/crypto_scheme |
|
|
pdf_data/cert_keywords/crypto_protocol |
|
|
pdf_data/cert_keywords/randomness |
|
|
pdf_data/cert_keywords/cipher_mode |
|
|
pdf_data/cert_keywords/ecc_curve |
|
|
pdf_data/cert_keywords/crypto_engine |
|
|
pdf_data/cert_keywords/tls_cipher_suite |
|
|
pdf_data/cert_keywords/crypto_library |
|
|
pdf_data/cert_keywords/vulnerability |
|
|
pdf_data/cert_keywords/side_channel_analysis |
|
|
pdf_data/cert_keywords/technical_report_id |
|
|
pdf_data/cert_keywords/device_model |
|
|
pdf_data/cert_keywords/tee_name |
|
|
pdf_data/cert_keywords/os_name |
|
|
pdf_data/cert_keywords/cplc_data |
|
|
pdf_data/cert_keywords/ic_data_group |
|
|
pdf_data/cert_keywords/standard_id |
|
- ISO:
- ISO/IEC 15408: 2
- ISO/IEC 18045: 2
|
pdf_data/cert_keywords/javacard_version |
|
|
pdf_data/cert_keywords/javacard_api_const |
|
|
pdf_data/cert_keywords/javacard_packages |
|
|
pdf_data/cert_keywords/certification_process |
|
|
pdf_data/cert_metadata |
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid"
- /Subject: Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid
- /Title: Certificate BSI-DSZ-CC-0822-V6-2024
- pdf_file_size_bytes: 335622
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
pdf_data/report_filename |
st_vid10537-vr.pdf |
0822V6a_pdf.pdf |
pdf_data/report_frontpage |
- DE:
- US:
- cert_id: CCEVS-VR-VID10537-2014
- cert_item: Sourcefire 3D System Version 5.2.0.1
- cert_lab: US NIAP
|
- DE:
- cc_security_level: Common Criteria Part 3 conformant EAL 4 augmented by ALC_FLR.2 and AVA_VAN.5 valid until: 19 December 2032
- cc_version: PP conformant Common Criteria Part 2 extended
- cert_id: BSI-DSZ-CC-0822-V6-2024
- cert_item: SMARTY IQ-LTE, Version 1.4
- cert_lab: BSI
- developer: Sagemcom Dr. Neuhaus GmbH
- match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
- ref_protection_profiles: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014
- US:
|
pdf_data/report_keywords/cc_cert_id |
- US:
- CCEVS-VR-VID10537-2014: 1
|
- DE:
- BSI-DSZ-CC-0822-V5-2023: 3
- BSI-DSZ-CC-0822-V6-2024: 14
- BSI-DSZ-CC-0957-: 1
|
pdf_data/report_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073-2014: 3
- BSI-CC-PP-0077-V2-2015: 2
|
pdf_data/report_keywords/cc_security_level |
|
- EAL:
- EAL 1: 1
- EAL 2: 3
- EAL 4: 8
- EAL 4 augmented: 3
- EAL 5: 3
- EAL 5+: 1
- EAL 6: 1
|
pdf_data/report_keywords/cc_sar |
|
|
pdf_data/report_keywords/cc_sfr |
|
|
pdf_data/report_keywords/cc_claims |
|
|
pdf_data/report_keywords/vendor |
|
|
pdf_data/report_keywords/eval_facility |
|
- TUV:
- TÜV Informationstechnik: 3
|
pdf_data/report_keywords/symmetric_crypto |
- AES_competition:
- constructions:
- MAC:
- HMAC-SHA-384: 1
- HMAC-SHA-512: 1
|
- AES_competition:
- constructions:
|
pdf_data/report_keywords/asymmetric_crypto |
|
|
pdf_data/report_keywords/pq_crypto |
|
|
pdf_data/report_keywords/hash_function |
|
|
pdf_data/report_keywords/crypto_scheme |
|
|
pdf_data/report_keywords/crypto_protocol |
|
|
pdf_data/report_keywords/randomness |
|
|
pdf_data/report_keywords/cipher_mode |
|
|
pdf_data/report_keywords/ecc_curve |
|
|
pdf_data/report_keywords/crypto_engine |
|
|
pdf_data/report_keywords/tls_cipher_suite |
|
|
pdf_data/report_keywords/crypto_library |
|
|
pdf_data/report_keywords/vulnerability |
|
|
pdf_data/report_keywords/side_channel_analysis |
|
|
pdf_data/report_keywords/technical_report_id |
|
- BSI:
- BSI 7148: 1
- BSI TR-03109: 1
- BSI TR-03116: 1
|
pdf_data/report_keywords/device_model |
|
|
pdf_data/report_keywords/tee_name |
|
|
pdf_data/report_keywords/os_name |
|
|
pdf_data/report_keywords/cplc_data |
|
|
pdf_data/report_keywords/ic_data_group |
|
|
pdf_data/report_keywords/standard_id |
- FIPS:
- FIPS PUB 140-2: 1
- FIPS PUB 180-3: 1
- FIPS PUB 186-2: 1
- FIPS PUB 197: 1
- FIPS PUB 198-1: 1
- NIST:
|
- BSI:
- AIS 32: 1
- AIS 34: 2
- AIS 38: 1
- AIS 46: 2
- AIS 48: 1
- FIPS:
- FIPS 186-4: 1
- FIPS PUB 180-4: 1
- FIPS PUB 186: 1
- FIPS180-4: 3
- ISO:
- ISO/IEC 15408: 4
- ISO/IEC 17065: 2
- ISO/IEC 18045: 4
- RFC:
- RFC 2104: 1
- RFC 5246: 1
- RFC 5639: 1
- RFC 5652: 1
- RFC 8289: 1
- RFC 8422: 1
- RFC2104: 2
- RFC4493: 6
- RFC5084: 2
- RFC5246: 6
- RFC5288: 2
- RFC5289: 3
- RFC5639: 6
- RFC5652: 4
- RFC6033: 2
- RFC6090: 4
- RFC6161: 2
- RFC8422: 2
|
pdf_data/report_keywords/javacard_version |
|
|
pdf_data/report_keywords/javacard_api_const |
|
|
pdf_data/report_keywords/javacard_packages |
|
|
pdf_data/report_keywords/certification_process |
|
- ConfidentialDocument:
- 23 / 27 Certification Report BSI-DSZ-CC-0822-V6-2024 [9] Configuration list for the TOE (confidential documents): filelist_OS, 2024-11-12 filelist_sln8209, 2024-11-12 8209SE011_SMGw_CPU_USB, Version 3.3: 1
- Technical Report BSI-DSZ-CC-0822-V6, Version 1, 2024-11-15, TÜV Informationstechnik GmbH, (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014: 1
- being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
|
pdf_data/report_metadata |
- /Author: Robert Roland
- /Comments:
- /Company: COACT
- /CreationDate: D:20140807135046-04'00'
- /Creator: Acrobat PDFMaker 10.1 for Word
- /Keywords:
- /ModDate: D:20140807135101-04'00'
- /Producer: Adobe PDF Library 10.0
- /SourceModified: D:20140807175026
- /Subject:
- /Title:
- pdf_file_size_bytes: 136944
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 20
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid"
- /Subject: Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid
- /Title: Certification Report BSI-DSZ-CC-0822-V6-2024
- pdf_file_size_bytes: 661868
- pdf_hyperlinks: http://www.commoncriteriaportal.org/cc/, https://www.sogis.eu/, https://www.bsi.bund.de/AIS, http://www.commoncriteriaportal.org/, https://www.commoncriteriaportal.org/, https://www.bsi.bund.de/zertifizierung, https://www.bsi.bund.de/zertifizierungsreporte, https://www.bsi.bund.de/
- pdf_is_encrypted: False
- pdf_number_of_pages: 27
|
pdf_data/st_filename |
st_vid10537-st.pdf |
0822V6b_pdf.pdf |
pdf_data/st_frontpage |
|
|
pdf_data/st_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0957-V2-2016: 1
|
pdf_data/st_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073: 4
- BSI-CC-PP-0077-2013: 1
|
pdf_data/st_keywords/cc_security_level |
|
- EAL:
- EAL 4: 5
- EAL 4 augmented: 2
- EAL4: 1
- EAL4 augmented: 1
|
pdf_data/st_keywords/cc_sar |
- ADV:
- AGD:
- AGD_OPE: 1
- AGD_OPE.1: 15
- AGD_PRE: 1
- AGD_PRE.1: 11
- ALC:
- ALC_CMC: 1
- ALC_CMC.1: 5
- ALC_CMS: 1
- ALC_CMS.1: 6
- ATE:
- AVA:
|
- ADV:
- ADV_ARC.1: 1
- ADV_IMP.1: 1
- AGD:
- ALC:
- ALC_CMC.4: 1
- ALC_DEL.1: 1
- ALC_FLR.2: 6
- ALC_LCD.1: 1
- ASE:
- ASE_CCL.1: 1
- ASE_INT.1: 1
- ASE_REQ.2: 1
- ASE_TSS.1: 1
- ATE:
- ATE_COV.2: 1
- ATE_FUN.1: 1
- AVA:
|
pdf_data/st_keywords/cc_sfr |
- FAU:
- FAU_GEN: 11
- FAU_GEN.1: 6
- FAU_GEN.1.1: 1
- FAU_GEN.1.2: 1
- FAU_GEN.2: 3
- FAU_GEN.2.1: 1
- FAU_STG_EXT: 5
- FAU_STG_EXT.1: 4
- FAU_STG_EXT.1.1: 1
- FCS:
- FCS_CKM: 5
- FCS_CKM.1: 9
- FCS_CKM.1.1: 1
- FCS_CKM.2: 1
- FCS_CKM.4: 5
- FCS_CKM_EXT: 5
- FCS_CKM_EXT.4: 8
- FCS_CKM_EXT.4.1: 1
- FCS_COP.1: 33
- FCS_COP.1.1: 4
- FCS_RBG_EXT: 5
- FCS_RBG_EXT.1: 4
- FCS_RBG_EXT.1.1: 1
- FCS_RBG_EXT.1.2: 1
- FCS_SSH_EXT: 5
- FCS_SSH_EXT.1: 4
- FCS_SSH_EXT.1.1: 1
- FCS_SSH_EXT.1.2: 1
- FCS_SSH_EXT.1.3: 1
- FCS_SSH_EXT.1.4: 1
- FCS_SSH_EXT.1.5: 1
- FCS_SSH_EXT.1.6: 1
- FCS_SSH_EXT.1.7: 1
- FCS_TLS_EXT: 5
- FCS_TLS_EXT.1: 6
- FCS_TLS_EXT.1.1: 2
- FDP:
- FDP_ITC.1: 5
- FDP_ITC.2: 5
- FDP_RIP: 5
- FDP_RIP.2: 3
- FDP_RIP.2.1: 1
- FIA:
- FIA_PMG_EXT: 5
- FIA_PMG_EXT.1: 4
- FIA_PMG_EXT.1.1: 1
- FIA_UAU: 5
- FIA_UAU.7: 3
- FIA_UAU.7.1: 1
- FIA_UAU_EXT: 5
- FIA_UAU_EXT.2: 4
- FIA_UAU_EXT.2.1: 1
- FIA_UIA_EXT: 4
- FIA_UIA_EXT.1: 7
- FIA_UIA_EXT.1.1: 1
- FIA_UIA_EXT.1.2: 1
- FIA_UID.1: 2
- FIA_UID_EXT: 1
- FMT:
- FMT_MTD: 5
- FMT_MTD.1: 3
- FMT_MTD.1.1: 1
- FMT_SMF: 6
- FMT_SMF.1: 5
- FMT_SMF.1.1: 1
- FMT_SMR: 5
- FMT_SMR.2: 3
- FMT_SMR.2.1: 1
- FMT_SMR.2.2: 1
- FMT_SMR.2.3: 1
- FPT:
- FPT_APW_EXT: 3
- FPT_APW_EXT.1: 4
- FPT_APW_EXT.1.1: 1
- FPT_APW_EXT.1.2: 1
- FPT_AWP_EXT: 2
- FPT_ITT: 5
- FPT_ITT.1: 7
- FPT_ITT.1.1: 1
- FPT_SKP_EXT: 5
- FPT_SKP_EXT.1: 4
- FPT_SKP_EXT.1.1: 1
- FPT_STM: 5
- FPT_STM.1: 4
- FPT_STM.1.1: 1
- FPT_TST_EXT: 5
- FPT_TST_EXT.1: 4
- FPT_TST_EXT.1.1: 1
- FPT_TUD_EXT: 5
- FPT_TUD_EXT.1: 4
- FPT_TUD_EXT.1.1: 1
- FPT_TUD_EXT.1.2: 1
- FPT_TUD_EXT.1.3: 1
- FTA:
- FTA_SSL: 12
- FTA_SSL.3: 3
- FTA_SSL.3.1: 1
- FTA_SSL.4: 4
- FTA_SSL.4.1: 1
- FTA_SSL_EXT: 6
- FTA_SSL_EXT.1: 4
- FTA_SSL_EXT.1.1: 1
- FTA_TAB: 5
- FTA_TAB.1: 4
- FTA_TAB.1.1: 1
- FTP:
- FTP_ITC: 5
- FTP_ITC.1: 3
- FTP_ITC.1.1: 1
- FTP_ITC.1.2: 1
- FTP_ITC.1.3: 1
- FTP_TRP: 6
- FTP_TRP.1: 3
- FTP_TRP.1.1: 1
- FTP_TRP.1.2: 1
- FTP_TRP.1.3: 1
|
- FAU:
- FAU_ARP: 10
- FAU_ARP.1: 1
- FAU_CON.1.2: 1
- FAU_GEN: 39
- FAU_GEN.1: 17
- FAU_GEN.2: 10
- FAU_GEN.2.1: 1
- FAU_SAA: 15
- FAU_SAA.1: 4
- FAU_SAR: 30
- FAU_SAR.1: 6
- FAU_STG: 34
- FAU_STG.1: 8
- FAU_STG.2: 10
- FAU_STG.2.1: 1
- FAU_STG.2.2: 1
- FAU_STG.2.3: 1
- FAU_STG.3: 3
- FAU_STG.4: 3
- FCO:
- FCO_NRO: 3
- FCO_NRO.1: 1
- FCO_NRO.2: 11
- FCO_NRO.2.1: 1
- FCO_NRO.2.2: 1
- FCO_NRO.2.3: 1
- FCS:
- FCS_CKM: 51
- FCS_CKM.1: 16
- FCS_CKM.2: 6
- FCS_CKM.4: 30
- FCS_CKM.4.1: 1
- FCS_COP: 68
- FCS_COP.1: 11
- FDP:
- FDP_ACC: 2
- FDP_ACC.1: 9
- FDP_ACC.2: 12
- FDP_ACC.2.1: 1
- FDP_ACC.2.2: 1
- FDP_ACF: 1
- FDP_ACF.1: 11
- FDP_ACF.1.1: 1
- FDP_ACF.1.2: 1
- FDP_ACF.1.3: 1
- FDP_ACF.1.4: 1
- FDP_IFC: 29
- FDP_IFC.1: 12
- FDP_IFC.2: 4
- FDP_IFF: 26
- FDP_IFF.1: 18
- FDP_ITC.1: 12
- FDP_ITC.2: 12
- FDP_RIP: 2
- FDP_RIP.1: 1
- FDP_RIP.2: 8
- FDP_RIP.2.1: 1
- FDP_SDI: 2
- FDP_SDI.1: 1
- FDP_SDI.2: 9
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FIA:
- FIA_AFL: 3
- FIA_AFL.1: 10
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_ATD: 3
- FIA_ATD.1: 13
- FIA_ATD.1.1: 1
- FIA_UAU: 5
- FIA_UAU.1: 2
- FIA_UAU.2: 9
- FIA_UAU.2.1: 1
- FIA_UAU.5: 9
- FIA_UAU.5.1: 1
- FIA_UAU.5.2: 1
- FIA_UAU.6: 10
- FIA_UAU.6.1: 1
- FIA_UID: 3
- FIA_UID.1: 8
- FIA_UID.2: 14
- FIA_UID.2.1: 1
- FIA_USB: 3
- FIA_USB.1: 9
- FIA_USB.1.1: 1
- FIA_USB.1.2: 1
- FIA_USB.1.3: 1
- FMT:
- FMT_MOF: 1
- FMT_MOF.1: 9
- FMT_MOF.1.1: 1
- FMT_MSA: 64
- FMT_MSA.1: 9
- FMT_MSA.3: 12
- FMT_SMF: 2
- FMT_SMF.1: 19
- FMT_SMF.1.1: 1
- FMT_SMR: 3
- FMT_SMR.1: 29
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPR:
- FPR_CON: 6
- FPR_CON.1: 12
- FPR_CON.1.1: 3
- FPR_CON.1.2: 3
- FPR_PSE: 3
- FPR_PSE.1: 9
- FPR_PSE.1.1: 1
- FPR_PSE.1.2: 1
- FPR_PSE.1.3: 1
- FPT:
- FPT_FLS: 3
- FPT_FLS.1: 9
- FPT_FLS.1.1: 2
- FPT_PHP: 3
- FPT_PHP.1: 8
- FPT_PHP.1.1: 1
- FPT_PHP.1.2: 1
- FPT_RPL: 3
- FPT_RPL.1: 10
- FPT_RPL.1.1: 1
- FPT_RPL.1.2: 1
- FPT_STM: 3
- FPT_STM.1: 20
- FPT_STM.1.1: 1
- FPT_TST: 3
- FPT_TST.1: 10
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FTP:
|
pdf_data/st_keywords/cc_claims |
- A:
- A.CONNECTIONS: 4
- A.NO_GENERAL_PURPOSE: 1
- A.PHYSICAL: 1
- A.TRUSTED_ADMIN: 1
- O:
- O.ADDRESS_FILTERING: 5
- O.DISPLAY_BANNER: 1
- O.PORT_FILTERING: 5
- O.PROTECTED_COMMUNICATIONS: 1
- O.RELATED_CONNECTION_FILTERING: 5
- O.RESIDUAL_INFORMATION_CLEARING: 1
- O.SESSION_LOCK: 1
- O.STATEFUL_INSPECTION: 5
- O.SYSTEM_MONITORING: 1
- O.TOE_ADMINISTRATION: 1
- O.TSF_SELF_TEST: 1
- O.VERIFIABLE_UPDATES: 1
- OE:
- T:
- T.ADMIN_ERROR: 1
- T.NETWORK_ACCESS: 3
- T.NETWORK_DISCLOSURE: 2
- T.NETWORK_DOS: 4
- T.NETWORK_MISUSE: 2
- T.TSF_FAILURE: 1
- T.UNAUTHORIZED_ACCESS: 1
- T.UNAUTHORIZED_UPDATE: 1
- T.UNDETECTED_ACTIONS: 1
- T.USER_DATA_REUSE: 1
|
|
pdf_data/st_keywords/vendor |
|
|
pdf_data/st_keywords/eval_facility |
|
|
pdf_data/st_keywords/symmetric_crypto |
- AES_competition:
- DES:
- constructions:
- MAC:
- HMAC-SHA-256: 2
- HMAC-SHA-384: 1
- HMAC-SHA-512: 1
|
- AES_competition:
- constructions:
|
pdf_data/st_keywords/asymmetric_crypto |
|
|
pdf_data/st_keywords/pq_crypto |
|
|
pdf_data/st_keywords/hash_function |
- SHA:
- SHA1:
- SHA2:
- SHA-224: 4
- SHA-256: 2
- SHA-384: 5
- SHA-512: 12
|
- JH:
- SHA:
- SHA2:
- SHA-256: 3
- SHA-384: 2
- SHA256: 1
|
pdf_data/st_keywords/crypto_scheme |
- KA:
- Key Agreement: 1
- Key agreement: 1
|
|
pdf_data/st_keywords/crypto_protocol |
- SSH:
- SSH: 37
- SSHv1: 2
- SSHv2: 19
- TLS:
- VPN:
|
|
pdf_data/st_keywords/randomness |
|
|
pdf_data/st_keywords/cipher_mode |
|
|
pdf_data/st_keywords/ecc_curve |
|
- NIST:
- NIST P-256: 2
- NIST P-384: 1
- P-256: 2
- P-384: 1
|
pdf_data/st_keywords/crypto_engine |
|
|
pdf_data/st_keywords/tls_cipher_suite |
- TLS:
- TLS_DHE_RSA_WITH_AES_128_CBC_SHA: 1
- TLS_DHE_RSA_WITH_AES_256_CBC_SHA: 2
- TLS_RSA_WITH_AES_128_CBC_SHA: 2
- TLS_RSA_WITH_AES_256_CBC_SHA: 2
|
- TLS:
- TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256: 2
- TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256: 2
- TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384: 2
- TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384: 2
|
pdf_data/st_keywords/crypto_library |
|
|
pdf_data/st_keywords/vulnerability |
|
|
pdf_data/st_keywords/side_channel_analysis |
|
- FI:
- malfunction: 3
- physical tampering: 2
|
pdf_data/st_keywords/technical_report_id |
|
- BSI:
- BSI 7586: 1
- BSI TR-02102-2: 1
- BSI TR-03109: 1
- BSI TR-03109-1: 9
- BSI TR-03109-2: 1
- BSI TR-03109-3: 1
- BSI TR-03109-4: 1
- BSI TR-03111: 1
- BSI TR-03116-3: 1
- BSI TR-03116-4: 1
|
pdf_data/st_keywords/device_model |
|
|
pdf_data/st_keywords/tee_name |
|
|
pdf_data/st_keywords/os_name |
|
|
pdf_data/st_keywords/cplc_data |
|
|
pdf_data/st_keywords/ic_data_group |
|
|
pdf_data/st_keywords/standard_id |
- FIPS:
- FIPS 140-2: 4
- FIPS 186-2: 1
- FIPS 186-3: 1
- FIPS PUB 140-2: 1
- FIPS PUB 180-3: 1
- FIPS PUB 186-2: 2
- FIPS PUB 186-3: 1
- FIPS PUB 197: 2
- FIPS PUB 198-1: 1
- NIST:
- NIST SP 800-38A: 2
- NIST SP 800-56B: 1
- SP 800-56B: 3
- SP 800-90: 1
- RFC:
- RFC 2246: 2
- RFC 2460: 2
- RFC 2818: 2
- RFC 3513: 2
- RFC 4253: 1
- RFC 4443: 2
- RFC 5735: 2
- RFC 768: 2
- RFC 791: 2
- RFC 792: 2
- RFC 793: 2
- RFC 959: 1
|
- BSI:
- FIPS:
- FIPS 140-2: 1
- FIPS 180-4: 3
- FIPS 197: 6
- RFC:
- RFC 2104: 4
- RFC 4493: 5
- RFC 5084: 3
- RFC 5246: 4
- RFC 5289: 4
- RFC 5652: 1
- RFC 5905: 3
- RFC5246: 2
- RFC5905: 1
|
pdf_data/st_keywords/javacard_version |
|
|
pdf_data/st_keywords/javacard_api_const |
|
- curves:
- SECP256R1: 2
- SECP384R1: 1
|
pdf_data/st_keywords/javacard_packages |
|
|
pdf_data/st_keywords/certification_process |
- OutOfScope:
- NTP Server SMTP Server Audit Server SNMP Server Network Assets Legend TOE Operational Environment Out of Scope … … Sourcefire 3D System Security Target 13 The TOE main subsystems are summarized as followed: •: 1
- Out of Scope: 1
- in the update header to ensure they match. 12 This process requires access to the Internet and is out of scope of the evaluation. Sourcefire 3D System Security Target 61 During the update process, if the Snort: 1
- out of scope: 1
|
|
pdf_data/st_metadata |
|
- /Author: Federal Office for Information Security
- /Keywords: Smart Meter System, Gateway, Common Criteria, Smart Meter Gateway PP
- /Subject: Schutzprofil für die Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen
- /Title: Sagemcom Dr. Neuhaus SMARTY IQ-LTE Security Target
- pdf_file_size_bytes: 2020364
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 112
|
state/cert/convert_garbage |
False |
False |
state/cert/convert_ok |
False |
True |
state/cert/download_ok |
False |
True |
state/cert/extract_ok |
False |
True |
state/cert/pdf_hash |
Different |
Different |
state/cert/txt_hash |
Different |
Different |
state/report/convert_garbage |
False |
False |
state/report/convert_ok |
True |
True |
state/report/download_ok |
True |
True |
state/report/extract_ok |
True |
True |
state/report/pdf_hash |
Different |
Different |
state/report/txt_hash |
Different |
Different |
state/st/convert_garbage |
False |
False |
state/st/convert_ok |
True |
True |
state/st/download_ok |
True |
True |
state/st/extract_ok |
True |
True |
state/st/pdf_hash |
Different |
Different |
state/st/txt_hash |
Different |
Different |