Comparing certificates Experimental feature

You are comparing two certificates. By default, only differing attributes are shown. Use the button below to show/hide all attributes.

Showing only differing attributes.
TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA
BSI-DSZ-CC-0957-V2-2016
TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA
BSI-DSZ-CC-0957-2015
not_valid_after 18.11.2026 10.02.2025
not_valid_before 18.11.2016 09.02.2015
report_link https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957V2a_pdf.pdf https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957a_pdf.pdf
st_link https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957V2b_pdf.pdf https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957b_pdf.pdf
dgst 6c674f76d69001ee d6739d0e1ce9ed2c
heuristics/cert_id BSI-DSZ-CC-0957-V2-2016 BSI-DSZ-CC-0957-2015
heuristics/report_references/directly_referenced_by BSI-DSZ-CC-0831-V6-2023, BSI-DSZ-CC-0919-V3-2023, BSI-DSZ-CC-0918-V5-2023, BSI-DSZ-CC-1035-2017, BSI-DSZ-CC-0831-V8-2024, BSI-DSZ-CC-0831-V3-2021, BSI-DSZ-CC-0831-V2-2020, BSI-DSZ-CC-0831-V5-2022, BSI-DSZ-CC-0831-V9-2024, BSI-DSZ-CC-0918-V4-2022, BSI-DSZ-CC-0919-V2-2021, BSI-DSZ-CC-0831-V7-2023, BSI-DSZ-CC-0831-V4-2021, BSI-DSZ-CC-0918-V6-2024 BSI-DSZ-CC-0957-V2-2016
heuristics/report_references/directly_referencing BSI-DSZ-CC-0978-2016, BSI-DSZ-CC-0957-2015 BSI-DSZ-CC-0845-V2-2013
heuristics/report_references/indirectly_referenced_by BSI-DSZ-CC-0831-V6-2023, BSI-DSZ-CC-0919-V3-2023, BSI-DSZ-CC-0918-V5-2023, BSI-DSZ-CC-1035-2017, BSI-DSZ-CC-0831-V8-2024, BSI-DSZ-CC-0831-V3-2021, BSI-DSZ-CC-0831-V2-2020, BSI-DSZ-CC-0831-V5-2022, BSI-DSZ-CC-0831-V9-2024, BSI-DSZ-CC-0918-V4-2022, BSI-DSZ-CC-0919-V2-2021, BSI-DSZ-CC-0831-V7-2023, BSI-DSZ-CC-0831-V4-2021, BSI-DSZ-CC-0918-V6-2024 BSI-DSZ-CC-0831-V6-2023, BSI-DSZ-CC-0957-V2-2016, BSI-DSZ-CC-0919-V3-2023, BSI-DSZ-CC-0918-V5-2023, BSI-DSZ-CC-1035-2017, BSI-DSZ-CC-0831-V8-2024, BSI-DSZ-CC-0831-V3-2021, BSI-DSZ-CC-0831-V2-2020, BSI-DSZ-CC-0831-V5-2022, BSI-DSZ-CC-0831-V9-2024, BSI-DSZ-CC-0918-V4-2022, BSI-DSZ-CC-0919-V2-2021, BSI-DSZ-CC-0831-V7-2023, BSI-DSZ-CC-0831-V4-2021, BSI-DSZ-CC-0918-V6-2024
heuristics/report_references/indirectly_referencing BSI-DSZ-CC-0845-V2-2013, BSI-DSZ-CC-0957-2015, BSI-DSZ-CC-0666-2012, BSI-DSZ-CC-0978-2016, BSI-DSZ-CC-0845-2012 BSI-DSZ-CC-0845-V2-2013, BSI-DSZ-CC-0845-2012, BSI-DSZ-CC-0666-2012
heuristics/scheme_data
  • category: Intelligent measuring systems
  • cert_id: BSI-DSZ-CC-0957-V2-2016
  • certification_date: 2016-11-18
  • enhanced:
    • applicant: Deutsche Telekom Security GmbH Untere Industriestraße 20 57250 Netphen
    • assurance_level: EAL4+,AVA_VAN.5
    • certification_date: 2016-11-18
    • description: The Target of Evaluation (TOE) is the product TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA developed by T-Systems International GmbH. The TOE is a Smart Meter Security Module according to the Technical Guideline BSI TR-03109-2, Version 1.1 intended to be used by a Smart Meter Gateway in a Smart Metering System. The TOE serves as cryptographic service provider for the Smart Meter Gateway and supports the Smart Meter Gateway for its specific cryptographic needs. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further data relevant for the Gateway.
    • entries: [frozendict({'id': 'BSI-DSZ-CC-0957-V2-2016-RA-01 (Ausstellungsdatum / Certification Date 27.09.2021)', 'description': 'Re-Assessment'}), frozendict({'id': 'BSI-DSZ-CC-0957-V2-2016 (Ausstellungsdatum / Certification Date 18.11.2016, gültig bis / valid until 17.11.2026)', 'description': 'TCOS Smart Meter Security Module Version 1.0 Release 2/P60C144PVE'}), frozendict({'id': 'BSI-DSZ-CC-0957-2015 (Ausstellungsdatum / Certification Date 09.02.2015, gültig bis / valid until 09.02.2025)', 'description': 'Security Target'})]
    • evaluation_facility: SRC Security Research & Consulting GmbH
    • expiration_date: 2026-11-17
    • product: TCOS Smart Meter Security Module Version 1.0 Release 2/P60C144PVE
    • protection_profile: Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015
    • report_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte09/0957V2a_pdf.pdf?__blob=publicationFile&v=1
    • target_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte09/0957V2b_pdf.pdf?__blob=publicationFile&v=1
  • product: TCOS Smart Meter Security Module Version 1.0 Release 2/P60C144PVE
  • subcategory: Security module for an Smart Metering Gateway
  • url: https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/Smartmeter_Sicherheitsmodule/0957_0957V2_0957V2RA1.html
  • vendor: Deutsche Telekom Security GmbH
  • category: Intelligent measuring systems
  • cert_id: BSI-DSZ-CC-1035-2017
  • certification_date: 2017-10-06
  • enhanced:
    • applicant: T-Systems International GmbH Untere Industriestraße 20 57250 Netphen
    • assurance_level: EAL4+,AVA_VAN.5
    • certification_date: 2017-10-06
    • description: The Target of Evaluation (TOE) is the product TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE developed by T-Systems International GmbH. The TOE is a Security Module according to the Technical Guideline BSI TR-03109-2 Annex B, Version 1.0 and is intended to be integrated in a so-called Smart Meter Mini-HSM. The TOE serves as a cryptographic service provider and supports different parties (as e.g. the Gateway Administrator) for their specific cryptographic needs in the framework of Smart Metering Systems. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further sensitive data relevant for the user.
    • evaluation_facility: SRC Security Research & Consulting GmbH
    • expiration_date: 2027-10-05
    • product: TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE
    • report_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035a_pdf.pdf?__blob=publicationFile&v=1
    • target_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035b_pdf.pdf?__blob=publicationFile&v=1
  • product: TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE
  • subcategory: Security module for an Smart Meter Mini-HSM
  • url: https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_MiniHSM/1035.html
  • vendor: T-Systems International GmbH
heuristics/st_references/directly_referenced_by BSI-DSZ-CC-0919-V3-2023, BSI-DSZ-CC-0918-V5-2023, BSI-DSZ-CC-0918-V3-2022, BSI-DSZ-CC-0918-V2-2021, BSI-DSZ-CC-0918-2020, BSI-DSZ-CC-0918-V4-2022, BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0919-V2-2021, BSI-DSZ-CC-0918-V6-2024, BSI-DSZ-CC-0822-V5-2023 {}
heuristics/st_references/directly_referencing BSI-DSZ-CC-0978-2016 {}
heuristics/st_references/indirectly_referenced_by BSI-DSZ-CC-0919-V3-2023, BSI-DSZ-CC-0918-V5-2023, BSI-DSZ-CC-0918-V3-2022, BSI-DSZ-CC-0918-V2-2021, BSI-DSZ-CC-0918-2020, BSI-DSZ-CC-0918-V4-2022, BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0919-V2-2021, BSI-DSZ-CC-0918-V6-2024, BSI-DSZ-CC-0822-V5-2023 {}
heuristics/st_references/indirectly_referencing BSI-DSZ-CC-0978-2016 {}
pdf_data/report_filename 0957V2a_pdf.pdf 0957a_pdf.pdf
pdf_data/report_frontpage
  • DE:
    • cc_security_level: Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5
    • cc_version: PP conformant Common Criteria Part 2 extended
    • cert_id: BSI-DSZ-CC-0957-V2-2016
    • cert_item: TCOS Smart Meter Security Module Version 1.0 Release 2/P60C144PVE
    • cert_lab: BSI
    • developer: T-Systems International GmbH
    • match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
    • ref_protection_profiles: Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015
  • DE:
    • cc_security_level: Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 Valid until (*): 9 February 2025 SOGIS Recognition Agreement
    • cc_version: PP conformant Common Criteria Part 2 extended
    • cert_id: BSI-DSZ-CC-0957-2015
    • cert_item: TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA
    • cert_lab: BSI
    • developer: T-Systems International GmbH
    • match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
    • ref_protection_profiles: Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015
pdf_data/report_keywords/cc_cert_id
  • DE:
    • BSI-DSZ-CC-0957-2015: 3
    • BSI-DSZ-CC-0957-V2-2016: 24
    • BSI-DSZ-CC-0978: 2
    • BSI-DSZ-CC-0978-2016: 5
  • DE:
    • BSI-DSZ-CC-00845-V2-2013: 1
    • BSI-DSZ-CC-0845-V2-2013: 4
    • BSI-DSZ-CC-0957-2015: 24
pdf_data/report_keywords/eval_facility
  • SRC:
    • SRC Security Research & Consulting: 3
  • TSystems:
    • T-Systems International: 13
  • TUV:
    • TÜV Informationstechnik: 1
  • SRC:
    • SRC Security Research & Consulting: 3
  • TSystems:
    • T-Systems International: 13
pdf_data/report_keywords/technical_report_id
  • BSI:
    • BSI 7148: 1
    • BSI TR-03109-2: 1
  • BSI:
    • BSI 7125: 2
    • BSI 7138: 2
    • BSI 7148: 1
    • BSI TR-03109-2: 1
pdf_data/report_keywords/standard_id
  • BSI:
    • AIS 1: 1
    • AIS 20: 3
    • AIS 25: 1
    • AIS 26: 3
    • AIS 31: 1
    • AIS 32: 1
    • AIS 34: 2
    • AIS 36: 5
    • AIS 46: 1
  • FIPS:
    • FIPS 180-2: 2
    • FIPS 186: 5
    • FIPS 197: 2
  • ISO:
    • ISO/IEC 15408: 4
    • ISO/IEC 17065: 2
    • ISO/IEC 18045: 4
  • RFC:
    • RFC 5639: 5
  • BSI:
    • AIS 1: 1
    • AIS 20: 3
    • AIS 25: 1
    • AIS 26: 3
    • AIS 31: 1
    • AIS 32: 1
    • AIS 34: 2
    • AIS 36: 4
    • AIS 46: 1
    • AIS36: 1
  • FIPS:
    • FIPS 180-2: 2
    • FIPS 186: 5
    • FIPS 197: 2
  • ISO:
    • ISO/IEC 15408: 4
    • ISO/IEC 17065: 2
    • ISO/IEC 18045: 4
  • RFC:
    • RFC 5639: 5
pdf_data/report_keywords/certification_process
  • ConfidentialDocument:
    • 1.0 Release 2/P60C144PVE, Version 1.2, 27 October 2016, SRC Security Research & Consulting GmbH (confidential document) 9 specifically • AIS 1, Version 13, Durchführung der Ortsbesichtigung in der Entwicklungsumgebung: 1
    • Version 1.0 Release 2/P60C144PVE, Version 1.3, 25 October 2016, T-Systems International GmbH (confidential document) [10] Guidance Documentation BSI-DSZ-CC-0957-V2-2016, Operational Guidance for users and: 1
    • Y/B/X)/yVE, BSI-DSZ-CC-0978, Version 2, 17 December 2015, TÜV Informationstechnik GmbH (confidential document) [14] Product Data Sheet, SmartMX2 family P60x080/144 VA/VE, Secure high performance smart card: 1
    • being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
  • ConfidentialDocument:
    • 1.0 Release 1/P60C144PVA, Version 1.0, 9 February 2015, SRC Security Research & Consulting GmbH (confidential document) [9] Configuration List BSI-DSZ-CC-0957-2015, Konfigurationsliste von TCOS Smart Meter Security: 1
    • Version 1.0 Release 1/P60C144PVA, Version 1.1, 6 February 2015, T-Systems International GmbH (confidential document) 9 specifically • AIS 1, Version 13, Durchführung der Ortsbesichtigung in der Entwicklungsumgebung: 1
    • and certification procedure is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the product or resulting from the evaluation and certification: 1
pdf_data/report_metadata
  • /Author: Bundesamt für Sicherheit in der Informationstechnik
  • /CreationDate: D:20150212092005+01'00'
  • /Creator: Writer
  • /Keywords: "Common Criteria, Certification, Zertifizierung, Smart Meter Security Module"
  • /ModDate: D:20150212110928+01'00'
  • /Producer: LibreOffice 4.2
  • /Subject: Common Criteria Zertifizierung
  • /Title: Certification Report BSI-DSZ-CC-0957-2015
  • pdf_file_size_bytes: 1269846
  • pdf_hyperlinks: https://www.bsi.bund.de/zertifizierung, http://www.commoncriteriaportal.org/, https://www.bsi.bund.de/
  • pdf_is_encrypted: False
  • pdf_number_of_pages: 38
pdf_data/st_filename 0957V2b_pdf.pdf 0957b_pdf.pdf
pdf_data/st_keywords/cc_cert_id
  • DE:
    • BSI-DSZ-CC-0978: 1
    • BSI-DSZ-CC-0978-2016: 1
  • DE:
    • BSI-DSZ-CC-0957: 1
pdf_data/st_keywords/cc_sfr
  • FAU:
    • FAU_SAS.1: 1
  • FCS:
    • FCS_CKM: 51
    • FCS_CKM.1: 16
    • FCS_CKM.2: 8
    • FCS_CKM.4: 45
    • FCS_CKM.4.1: 1
    • FCS_COP: 59
    • FCS_COP.1: 15
    • FCS_RNG: 6
    • FCS_RNG.1: 20
    • FCS_RNG.1.1: 2
    • FCS_RNG.1.2: 2
  • FDP:
    • FDP_ACC.1: 13
    • FDP_ACC.2: 17
    • FDP_ACC.2.1: 1
    • FDP_ACC.2.2: 1
    • FDP_ACF: 2
    • FDP_ACF.1: 9
    • FDP_ACF.1.1: 1
    • FDP_ACF.1.2: 1
    • FDP_ACF.1.3: 1
    • FDP_ACF.1.4: 1
    • FDP_ETC.1: 7
    • FDP_ETC.1.1: 1
    • FDP_ETC.1.2: 1
    • FDP_IFC: 1
    • FDP_IFC.1: 8
    • FDP_ITC: 8
    • FDP_ITC.1: 20
    • FDP_ITC.1.1: 1
    • FDP_ITC.1.2: 1
    • FDP_ITC.1.3: 1
    • FDP_ITC.2: 14
    • FDP_ITT.1: 1
    • FDP_RIP: 1
    • FDP_RIP.1: 7
    • FDP_RIP.1.1: 1
    • FDP_SDI: 1
    • FDP_SDI.1: 1
    • FDP_SDI.2: 8
    • FDP_SDI.2.1: 1
    • FDP_SDI.2.2: 1
    • FDP_UCT.1: 8
    • FDP_UIT: 1
    • FDP_UIT.1: 7
    • FDP_UIT.1.2: 1
  • FIA:
    • FIA_ATD.1: 10
    • FIA_ATD.1.1: 1
    • FIA_SOS: 1
    • FIA_SOS.1: 3
    • FIA_SOS.1.1: 1
    • FIA_UAU: 18
    • FIA_UAU.1: 5
    • FIA_UAU.4: 6
    • FIA_UAU.4.1: 1
    • FIA_UAU.5: 6
    • FIA_UAU.5.1: 1
    • FIA_UAU.5.2: 1
    • FIA_UID: 1
    • FIA_UID.1: 14
    • FIA_UID.1.1: 1
    • FIA_UID.1.2: 1
    • FIA_USB: 1
    • FIA_USB.1: 6
    • FIA_USB.1.1: 1
    • FIA_USB.1.2: 1
    • FIA_USB.1.3: 1
  • FMT:
    • FMT_LIM: 6
    • FMT_LIM.1: 25
    • FMT_LIM.1.1: 2
    • FMT_LIM.2: 23
    • FMT_LIM.2.1: 2
    • FMT_MSA.1: 2
    • FMT_MSA.3: 6
    • FMT_SMF.1: 10
    • FMT_SMF.1.1: 1
    • FMT_SMR: 1
    • FMT_SMR.1: 6
    • FMT_SMR.1.1: 1
    • FMT_SMR.1.2: 1
  • FPT:
    • FPT_EMS: 6
    • FPT_EMS.1: 15
    • FPT_EMS.1.1: 2
    • FPT_EMS.1.2: 2
    • FPT_FLS: 1
    • FPT_FLS.1: 11
    • FPT_FLS.1.1: 1
    • FPT_ITT.1: 1
    • FPT_PHP: 1
    • FPT_PHP.3: 10
    • FPT_PHP.3.1: 1
    • FPT_TST: 1
    • FPT_TST.1: 7
    • FPT_TST.1.1: 1
    • FPT_TST.1.2: 1
    • FPT_TST.1.3: 1
  • FRU:
    • FRU_FLT.2: 1
  • FTP:
    • FTP_ICT.1: 4
    • FTP_ITC: 1
    • FTP_ITC.1: 10
    • FTP_ITC.1.1: 1
    • FTP_ITC.1.2: 1
    • FTP_ITC.1.3: 1
    • FTP_TRP.1: 4
  • FAU:
    • FAU_SAS.1: 1
  • FCS:
    • FCS_CKM: 49
    • FCS_CKM.1: 16
    • FCS_CKM.2: 8
    • FCS_CKM.4: 45
    • FCS_CKM.4.1: 1
    • FCS_COP: 59
    • FCS_COP.1: 17
    • FCS_RNG: 6
    • FCS_RNG.1: 20
    • FCS_RNG.1.1: 2
    • FCS_RNG.1.2: 2
  • FDP:
    • FDP_ACC.1: 13
    • FDP_ACC.2: 17
    • FDP_ACC.2.1: 1
    • FDP_ACC.2.2: 1
    • FDP_ACF: 2
    • FDP_ACF.1: 9
    • FDP_ACF.1.1: 1
    • FDP_ACF.1.2: 1
    • FDP_ACF.1.3: 1
    • FDP_ACF.1.4: 1
    • FDP_ETC.1: 7
    • FDP_ETC.1.1: 1
    • FDP_ETC.1.2: 1
    • FDP_IFC: 1
    • FDP_IFC.1: 8
    • FDP_ITC: 8
    • FDP_ITC.1: 20
    • FDP_ITC.1.1: 1
    • FDP_ITC.1.2: 1
    • FDP_ITC.1.3: 1
    • FDP_ITC.2: 14
    • FDP_ITT.1: 1
    • FDP_RIP: 1
    • FDP_RIP.1: 7
    • FDP_RIP.1.1: 1
    • FDP_SDI: 1
    • FDP_SDI.1: 1
    • FDP_SDI.2: 7
    • FDP_SDI.2.1: 1
    • FDP_SDI.2.2: 1
    • FDP_UCT.1: 8
    • FDP_UIT: 1
    • FDP_UIT.1: 7
    • FDP_UIT.1.1: 1
    • FDP_UIT.1.2: 1
  • FIA:
    • FIA_ATD.1: 10
    • FIA_ATD.1.1: 1
    • FIA_SOS: 1
    • FIA_SOS.1: 3
    • FIA_SOS.1.1: 1
    • FIA_UAU: 18
    • FIA_UAU.1: 5
    • FIA_UAU.4: 6
    • FIA_UAU.4.1: 1
    • FIA_UAU.5: 6
    • FIA_UAU.5.1: 1
    • FIA_UAU.5.2: 1
    • FIA_UID: 1
    • FIA_UID.1: 14
    • FIA_UID.1.1: 1
    • FIA_UID.1.2: 1
    • FIA_USB: 1
    • FIA_USB.1: 6
    • FIA_USB.1.1: 1
    • FIA_USB.1.2: 1
    • FIA_USB.1.3: 1
  • FMT:
    • FMT_LIM: 6
    • FMT_LIM.1: 25
    • FMT_LIM.1.1: 2
    • FMT_LIM.2: 23
    • FMT_LIM.2.1: 2
    • FMT_MSA.1: 2
    • FMT_MSA.3: 6
    • FMT_SMF.1: 10
    • FMT_SMF.1.1: 1
    • FMT_SMR: 1
    • FMT_SMR.1: 6
    • FMT_SMR.1.1: 1
    • FMT_SMR.1.2: 1
  • FPT:
    • FPT_EMS: 6
    • FPT_EMS.1: 15
    • FPT_EMS.1.1: 2
    • FPT_EMS.1.2: 2
    • FPT_FLS: 1
    • FPT_FLS.1: 11
    • FPT_FLS.1.1: 1
    • FPT_ITT.1: 1
    • FPT_PHP: 1
    • FPT_PHP.3: 10
    • FPT_PHP.3.1: 1
    • FPT_TST: 1
    • FPT_TST.1: 7
    • FPT_TST.1.1: 1
    • FPT_TST.1.2: 1
    • FPT_TST.1.3: 1
  • FRU:
    • FRU_FLT.2: 1
  • FTP:
    • FTP_ICT.1: 4
    • FTP_ITC: 1
    • FTP_ITC.1: 10
    • FTP_ITC.1.1: 1
    • FTP_ITC.1.2: 1
    • FTP_ITC.1.3: 1
    • FTP_TRP.1: 4
pdf_data/st_keywords/eval_facility
  • TSystems:
    • T-Systems International: 79
  • TSystems:
    • T-Systems International: 78
pdf_data/st_keywords/ecc_curve
  • Brainpool:
    • brainpoolP256r1: 2
    • brainpoolP384r1: 2
    • brainpoolP512r1: 2
  • NIST:
    • NIST P-256: 1
    • NIST P-384: 1
    • P-256: 11
    • P-384: 15
    • secp256r1: 1
    • secp384r1: 1
  • Brainpool:
    • brainpoolP256r1: 2
    • brainpoolP384r1: 2
    • brainpoolP512r1: 2
  • NIST:
    • NIST P-256: 1
    • NIST P-384: 1
    • P-256: 13
    • P-384: 15
    • secp256r1: 1
    • secp384r1: 1
pdf_data/st_keywords/standard_id
  • BSI:
    • AIS 36: 1
    • AIS36: 3
  • CC:
    • CCMB-2012-09-001: 1
    • CCMB-2012-09-002: 1
    • CCMB-2012-09-003: 2
    • CCMB-2012-09-004: 2
  • FIPS:
    • FIPS PUB 186-4: 1
    • FIPS186: 10
    • FIPS197: 3
  • ISO:
    • ISO/IEC 7810:2003: 1
  • RFC:
    • RFC 5639: 1
    • RFC5639: 11
  • X509:
    • X.509: 2
  • BSI:
    • AIS 36: 1
    • AIS36: 3
  • CC:
    • CCMB-2012-09-001: 1
    • CCMB-2012-09-002: 1
    • CCMB-2012-09-003: 2
    • CCMB-2012-09-004: 2
  • FIPS:
    • FIPS PUB 186-3: 1
    • FIPS186: 10
    • FIPS197: 3
  • ISO:
    • ISO/IEC 7810:2003: 1
  • RFC:
    • RFC 5639: 1
    • RFC5639: 11
  • X509:
    • X.509: 2
pdf_data/st_metadata
  • /Author: T-Systems International GmbH
  • /CreationDate: D:20150209010001
  • /Creator: PScript5.dll Version 5.2.2
  • /Keywords: TCOS Security Module, Sicherheitsmodul, Smart Meter
  • /ModDate: D:20150209135248+01'00'
  • /Producer: TeleSec ps2pdf
  • /Subject: TCOS Smart Meter Security Module Version 1.0 Release 1
  • /Title: Security Target TCOS Smart Meter Security Module (NXP)
  • pdf_file_size_bytes: 631545
  • pdf_hyperlinks: {}
  • pdf_is_encrypted: False
  • pdf_number_of_pages: 75
state/report/pdf_hash Different Different
state/report/txt_hash Different Different
state/st/pdf_hash Different Different
state/st/txt_hash Different Different