Secure Smart Grid Hub (SGH-S), V1.00

CSV information ?

Status active
Valid from 11.09.2023
Valid until 10.09.2031
Scheme 🇩🇪 DE
Manufacturer EFR GmbH
Category Other Devices and Systems
Security level AVA_VAN.5, ALC_FLR.2, EAL4+
Protection profiles
Maintenance updates Secure Smart Grid Hub (SGH-S) in the variants SGH-S-AL1-B-100 & SGH-S-AM1-B-100, V1.01 (16.01.2024) Certification report Security target

Heuristics summary ?

Certificate ID: BSI-DSZ-CC-1000-2023

Certificate ?

Extracted keywords

Security level
EAL 4, EAL 5, EAL 2, EAL 4 augmented
Security Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, AVA_VAN.5
Certificates
BSI-DSZ-CC-1000-2023

Standards
ISO/IEC 15408, ISO/IEC 18045

File metadata

Title Certification Report BSI-DSZ-CC-1000-2023
Subject Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR
Keywords "Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR"
Author Federal Office for Information Security
Pages 1

Certification report ?

Extracted keywords

Symmetric Algorithms
AES, AES-, HMAC, CMAC
Asymmetric Algorithms
ECC
Hash functions
SHA256, SHA-256, SHA-384, SHA-512
Schemes
MAC, Key Agreement
Protocols
SSH, TLS
Randomness
TRNG
Block cipher modes
CBC, GCM

Security level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 5+, EAL 6, EAL 4 augmented
Security Assurance Requirements (SAR)
ALC_FLR.2, ALC_FLR, ALC_CMS, ATE_COV, ATE_DPT, ATE_IND, AVA_VAN.5
Security Functional Requirements (SFR)
FCS_CKM.1, FMT_SMR.1
Protection profiles
BSI-CC-PP-0073-2014, BSI-CC-PP-0077-V2-2015, BSI-CC-PP-0073
Certificates
BSI-DSZ-CC-1000-2023
Evaluation facilities
SRC Security Research & Consulting

Side-channel analysis
side channel, physical tampering, malfunction
Certification process
out of scope, 2. Multiple Communication Modules for LTE exist, however these are non-TOE components and as such out of scope for this certification. 9. Results of the Evaluation 9.1. CC specific results The Evaluation, being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, ID BSI- DSZ-CC-1000, Version 1.3.2, 06.09.2023, SRC Security Research & Consulting GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, ALC_CMS “Konfigurations-Management-Scope Kon- figurationsliste”, v1.13, 30.08.2023, EFR GmbH (confidential document) [11] Servicetechniker Handbuch für das Smart-Meter-Gateway (SMGW) Secure Smart Grid Hub EFR SGH-S

Standards
FIPS 197, FIPS 180-4, AIS 34, AIS 46, AIS 48, AIS 32, RFC 5289, RFC-2104, RFC-3394, RFC 5084, RFC 5652, RFC 4493, RFC4493, RFC 2104, RFC 3394, RFC5246, RFC 5246, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065, ISO/IEC 18033-
Technical reports
BSI TR-03116, BSI TR-02102-1, BSI TR-03111, BSI 7148

File metadata

Title Certification Report BSI-DSZ-CC-1000-2023
Subject Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR
Keywords "Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR"
Author Federal Office for Information Security
Pages 26

Frontpage

Certificate ID BSI-DSZ-CC-1000-2023
Certified item Secure Smart Grid Hub (SGH-S) V1.00
Certification lab BSI
Developer EFR GmbH

Security target ?

Extracted keywords

Symmetric Algorithms
AES, AES-, HMAC, CMAC
Asymmetric Algorithms
ECDSA, ECC, Diffie-Hellman
Hash functions
SHA-256, SHA-384, SHA-512, SHA-2, JH
Schemes
MAC, Key agreement, Key Agreement
Protocols
TLS, TLSv1.2, PACE, VPN
Randomness
TRNG
Block cipher modes
GCM
TLS cipher suites
TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384, TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384

Security level
EAL4, EAL 4, EAL4 augmented, EAL 4 augmented
Claims
OE.SM, OSP.SM
Security Assurance Requirements (SAR)
ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_FLR.2, ALC_CMC.4, ALC_DEL.1, ALC_LCD.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5, ASE_CCL, ASE_SPD, ASE_OBJ, ASE_CCL.1, ASE_INT.1, ASE_OBJ.2, ASE_SPD.1
Security Functional Requirements (SFR)
FAU_ARP, FAU_GEN, FAU_SAA, FAU_SAR, FAU_STG, FAU_GEN.2, FAU_STG.2, FAU_GEN.1, FAU_SAA.1, FAU_SAR.1, FAU_STG.4, FAU_STG.3, FAU_STG.1, FAU_GEN.2.1, FAU_STG.2.1, FAU_STG.2.2, FAU_STG.2.3, FAU_STG.4.1, FCO_NRO, FCO_NRO.2, FCO_NRO.2.1, FCO_NRO.2.2, FCO_NRO.2.3, FCO_NRO.1, FCS_CKM, FCS_COP, FCS_CKM.4, FCS_CKM.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_IFC, FDP_ACC.2, FDP_ACF.1, FDP_IFF, FDP_RIP.2, FDP_SDI.2, FDP_ITC.1, FDP_ITC.2, FDP_ACC, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACC.1, FDP_ACF, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_IFC.2, FDP_IFC.1, FDP_IFF.1, FDP_IFF.1.3, FDP_RIP, FDP_RIP.2.1, FDP_RIP.1, FDP_SDI, FDP_SDI.2.1, FDP_SDI.2.2, FDP_SDI.1, FIA_ATD, FIA_AFL, FIA_UAU, FIA_UID, FIA_USB, FIA_ATD.1, FIA_AFL.1, FIA_UAU.2, FIA_UAU.5, FIA_UAU.6, FIA_UID.2, FIA_USB.1, FIA_UID.1, FIA_ATD.1.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_UAU.1, FIA_UAU.2.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UAU.6.1, FIA_UID.2.1, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_SMR, FMT_MOF.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA, FMT_MSA.3, FMT_MOF, FMT_MOF.1.1, FMT_SMF, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MSA.1, FPR_CON, FPR_CON.1, FPR_PSE, FPR_CON.1.2, FPR_CON.1.1, FPR_PSE.1, FPR_PSE.1.1, FPR_PSE.1.2, FPR_PSE.1.3, FPT_FLS, FPT_RPL, FPT_STM, FPT_TST, FPT_FLS.1, FPT_RPL.1, FPT_STM.1, FPT_TST.1, FPT_PHP.1, FPT_FLS.1.1, FPT_RPL.1.1, FPT_RPL.1.2, FPT_STM.1.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_PHP, FPT_PHP.1.1, FPT_PHP.1.2, FTP_ITC, FTP_ITC.1
Protection profiles
BSI-CC-PP-0077-2015, BSI-CC-PP-0073-2014, BSI-CC-PP-0073-, BSI-CC-PP-0077-, BSI-CC-PP-0077-V2-2015
Certificates
BSI-DSZ-CC-1003-2018, BSI-DSZ-CC-1003-

Side-channel analysis
physical tampering, malfunction

Standards
FIPS 180-4, FIPS 197, NIST SP 800-38A, NIST SP 800-38D, RFC-5289, RFC-5246, RFC-2104, RFC-3394, RFC-5084, RFC-5652, RFC-4493, RFC 2104, RFC 3394, RFC 4493, RFC 5084, RFC 5246, RFC 5289, RFC 5652
Technical reports
BSI TR-03109-1, BSI TR-03111, BSI TR-03116-3

File metadata

Title Security Target EFR SGH-S
Subject Common Criteria Evaluation
Author EFR GmbH
Pages 94

References

Outgoing
  • BSI-DSZ-CC-1003-2018 - active - Smart Meter Gateway Security Module Application on MultiApp V4 Revision A

Heuristics ?

Certificate ID: BSI-DSZ-CC-1000-2023

Extracted SARs

ADV_ARC.1, ADV_IMP.1, AGD_OPE.1, ALC_CMC.4, ALC_DEL.1, ALC_FLR.2, ALC_LCD.1, ASE_CCL.1, ASE_INT.1, ASE_OBJ.2, ASE_SPD.1, ATE_COV.2, ATE_FUN.1, AVA_VAN.5

Scheme data ?

Cert Id BSI-DSZ-CC-1000-2023
Product Secure Smart Grid Hub (SGH-S), V1.00
Vendor EFR GmbH
Certification Date 11.09.2023
Category Intelligent measuring systems
Url https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_Gateway/1000.html
Enhanced
Product Secure Smart Grid Hub (SGH-S), V1.00
Applicant EFR GmbH Nymphenburger Straße 20b 80335 München
Evaluation Facility SRC Security Research & Consulting GmbH
Assurance Level EAL4+,ALC_FLR.2,AVA_VAN.5
Protection Profile Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI-CC-PP-0073-2014
Certification Date 11.09.2023
Expiration Date 10.09.2031
Entries [frozendict({'id': 'BSI-DSZ-CC-1000-2023-MA-01', 'description': '(National Metrology Institute) requirements.'})]
Target Link https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1000b_pdf.pdf?__blob=publicationFile&v=2
Report Link https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1000a_pdf.pdf?__blob=publicationFile&v=2
Cert Link https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1000c_pdf.pdf?__blob=publicationFile&v=2
Description The TOE is the security functionality of a Smart Meter Gateway that serves as the communi-cation unit between devices of private and commercial consumers and commodity industry service providers (e.g., electricity, gas, water, etc.). It also collects, processes and stores Meter Data and is responsible for the distribution of this data to external entities
Subcategory (Smart Meter Gateway)

References ?

Updates ?

  • 21.11.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The following values were inserted: {'prev_certificates': [], 'next_certificates': []}.
  • 09.11.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The scheme_data property was updated, with the {'vendor': 'EFR GmbH', 'certification_date': '2023-09-11', 'enhanced': {'__update__': {'applicant': 'EFR GmbH Nymphenburger Straße 20b 80335 München', 'certification_date': '2023-09-11', 'expiration_date': '2031-09-10'}}} data.
  • 17.10.2024 The certificate data changed.
    Certificate changed

    The Protection Profiles of the certificate were updated.

    • The new value is {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.protection_profile.ProtectionProfile', 'pp_name': 'Protection Profile for the Gateway of a Smart Metering System', 'pp_eal': 'EAL4+', 'pp_link': 'https://www.commoncriteriaportal.org/files/ppfiles/pp0073b_pdf.pdf', 'pp_ids': {'_type': 'Set', 'elements': ['SMARTMETERGATEWAYPP_V1.3']}}]}.
  • 22.08.2024 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The report property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '57b155fe20efc25f3836337c59ac1164724520abc30588f29866132b703456c3', 'txt_hash': 'a2a510aa6f2651e8e8beacd81fc6f74c7242df981100703e46b7aa7d98db895a'} data.
    • The st property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '0a5f42e988f683a33db28884db26fbb433663de623f9554b8736c38e7c8bf9bf', 'txt_hash': '6ecf1f3fa8acc96b7591606fc90abf6f2f24928f242723d43e8172528186fd10'} data.
    • The cert property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '0415a2a4135ec0c104c98563d2bb53128b4f325793b309521286778102fd8f1a', 'txt_hash': '6f21749fdb90fe818f593cea73c31b4b5e4ad0a855413b23edf4a65b00a347bb'} data.

    The PDF extraction data was updated.

    • The report_metadata property was set to {'pdf_file_size_bytes': 492094, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 26, '/Author': 'Federal Office for Information Security', '/Keywords': '"Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR"', '/Subject': 'Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR', '/Title': 'Certification Report BSI-DSZ-CC-1000-2023', 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['https://www.bsi.bund.de/', 'https://www.commoncriteriaportal.org/', 'https://www.sogis.eu/', 'https://www.bsi.bund.de/zertifizierung', 'http://www.commoncriteriaportal.org/cc/', 'https://www.bsi.bund.de/zertifizierungsreporte', 'http://www.commoncriteriaportal.org/', 'https://www.bsi.bund.de/AIS']}}.
    • The st_metadata property was set to {'pdf_file_size_bytes': 1849024, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 94, '/Author': 'EFR GmbH', '/Subject': 'Common Criteria Evaluation', '/Title': 'Security Target EFR SGH-S', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}.
    • The cert_metadata property was set to {'pdf_file_size_bytes': 339208, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 1, '/Author': 'Federal Office for Information Security', '/Keywords': '"Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR"', '/Subject': 'Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR', '/Title': 'Certification Report BSI-DSZ-CC-1000-2023', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}.
    • The report_frontpage property was set to {'DE': {'match_rules': ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)'], 'cert_id': 'BSI-DSZ-CC-1000-2023', 'cert_item': 'Secure Smart Grid Hub (SGH-S) V1.00', 'developer': 'EFR GmbH', 'cert_lab': 'BSI', 'ref_protection_profiles': 'Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014', 'cc_version': 'PP conformant Common Criteria Part 2 extended', 'cc_security_level': 'Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2 valid until: 10 September 2031'}}.
    • The report_keywords property was set to {'cc_cert_id': {'DE': {'BSI-DSZ-CC-1000-2023': 13}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0073-2014': 3, 'BSI-CC-PP-0077-V2-2015': 2, 'BSI-CC-PP-0073': 1}}, 'cc_security_level': {'EAL': {'EAL 4': 8, 'EAL 5': 3, 'EAL 2': 3, 'EAL 1': 1, 'EAL 5+': 1, 'EAL 6': 1, 'EAL 4 augmented': 3}}, 'cc_sar': {'ALC': {'ALC_FLR.2': 4, 'ALC_FLR': 3, 'ALC_CMS': 1}, 'ATE': {'ATE_COV': 1, 'ATE_DPT': 1, 'ATE_IND': 1}, 'AVA': {'AVA_VAN.5': 5}}, 'cc_sfr': {'FCS': {'FCS_CKM.1': 1}, 'FMT': {'FMT_SMR.1': 1}}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {'SRC': {'SRC Security Research & Consulting': 1}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 9, 'AES-': 1}}, 'constructions': {'MAC': {'HMAC': 2, 'CMAC': 1}}}, 'asymmetric_crypto': {'ECC': {'ECC': {'ECC': 3}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA256': 5, 'SHA-256': 2, 'SHA-384': 1, 'SHA-512': 1}}}, 'crypto_scheme': {'MAC': {'MAC': 1}, 'KA': {'Key Agreement': 2}}, 'crypto_protocol': {'SSH': {'SSH': 1}, 'TLS': {'TLS': {'TLS': 7}}}, 'randomness': {'TRNG': {'TRNG': 1}}, 'cipher_mode': {'CBC': {'CBC': 1}, 'GCM': {'GCM': 3}}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'SCA': {'side channel': 1}, 'FI': {'physical tampering': 1, 'malfunction': 1}}, 'technical_report_id': {'BSI': {'BSI TR-03116': 1, 'BSI TR-02102-1': 1, 'BSI TR-03111': 1, 'BSI 7148': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS 197': 3, 'FIPS 180-4': 1}, 'BSI': {'AIS 34': 2, 'AIS 46': 2, 'AIS 48': 2, 'AIS 32': 1}, 'RFC': {'RFC 5289': 4, 'RFC-2104': 1, 'RFC-3394': 1, 'RFC 5084': 3, 'RFC 5652': 3, 'RFC 4493': 3, 'RFC4493': 1, 'RFC 2104': 2, 'RFC 3394': 2, 'RFC5246': 1, 'RFC 5246': 1}, 'ISO': {'ISO/IEC 15408': 4, 'ISO/IEC 18045': 4, 'ISO/IEC 17065': 2, 'ISO/IEC 18033-': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'OutOfScope': {'out of scope': 1, '2. Multiple Communication Modules for LTE exist, however these are non-TOE components and as such out of scope for this certification. 9. Results of the Evaluation 9.1. CC specific results The Evaluation': 1}, 'ConfidentialDocument': {'being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification': 1, 'ID BSI- DSZ-CC-1000, Version 1.3.2, 06.09.2023, SRC Security Research & Consulting GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014': 1, 'ALC_CMS “Konfigurations-Management-Scope Kon- figurationsliste”, v1.13, 30.08.2023, EFR GmbH (confidential document) [11] Servicetechniker Handbuch für das Smart-Meter-Gateway (SMGW) Secure Smart Grid Hub EFR SGH-S': 1}}}.
    • The st_keywords property was set to {'cc_cert_id': {'DE': {'BSI-DSZ-CC-1003-2018': 2, 'BSI-DSZ-CC-1003-': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0077-2015': 2, 'BSI-CC-PP-0073-2014': 5, 'BSI-CC-PP-0073-': 1, 'BSI-CC-PP-0077-': 1, 'BSI-CC-PP-0077-V2-2015': 1}}, 'cc_security_level': {'EAL': {'EAL4': 1, 'EAL 4': 4, 'EAL4 augmented': 1, 'EAL 4 augmented': 1}}, 'cc_sar': {'ADV': {'ADV_ARC.1': 1, 'ADV_IMP.1': 1}, 'AGD': {'AGD_OPE.1': 1}, 'ALC': {'ALC_FLR.2': 5, 'ALC_CMC.4': 1, 'ALC_DEL.1': 1, 'ALC_LCD.1': 1}, 'ATE': {'ATE_COV.2': 1, 'ATE_FUN.1': 1}, 'AVA': {'AVA_VAN.5': 6}, 'ASE': {'ASE_CCL': 2, 'ASE_SPD': 3, 'ASE_OBJ': 2, 'ASE_CCL.1': 1, 'ASE_INT.1': 1, 'ASE_OBJ.2': 1, 'ASE_SPD.1': 1}}, 'cc_sfr': {'FAU': {'FAU_ARP': 9, 'FAU_GEN': 30, 'FAU_SAA': 9, 'FAU_SAR': 21, 'FAU_STG': 23, 'FAU_GEN.2': 6, 'FAU_STG.2': 10, 'FAU_GEN.1': 22, 'FAU_SAA.1': 5, 'FAU_SAR.1': 9, 'FAU_STG.4': 3, 'FAU_STG.3': 3, 'FAU_STG.1': 8, 'FAU_GEN.2.1': 1, 'FAU_STG.2.1': 1, 'FAU_STG.2.2': 1, 'FAU_STG.2.3': 2, 'FAU_STG.4.1': 1}, 'FCO': {'FCO_NRO': 3, 'FCO_NRO.2': 8, 'FCO_NRO.2.1': 1, 'FCO_NRO.2.2': 1, 'FCO_NRO.2.3': 1, 'FCO_NRO.1': 1}, 'FCS': {'FCS_CKM': 48, 'FCS_COP': 49, 'FCS_CKM.4': 28, 'FCS_CKM.1': 6, 'FCS_CKM.2': 5, 'FCS_COP.1': 10, 'FCS_CKM.4.1': 2}, 'FDP': {'FDP_IFC': 24, 'FDP_ACC.2': 8, 'FDP_ACF.1': 7, 'FDP_IFF': 20, 'FDP_RIP.2': 7, 'FDP_SDI.2': 5, 'FDP_ITC.1': 12, 'FDP_ITC.2': 12, 'FDP_ACC': 2, 'FDP_ACC.2.1': 1, 'FDP_ACC.2.2': 1, 'FDP_ACC.1': 9, 'FDP_ACF': 1, 'FDP_ACF.1.1': 1, 'FDP_ACF.1.2': 1, 'FDP_ACF.1.3': 1, 'FDP_ACF.1.4': 1, 'FDP_IFC.2': 4, 'FDP_IFC.1': 12, 'FDP_IFF.1': 22, 'FDP_IFF.1.3': 1, 'FDP_RIP': 2, 'FDP_RIP.2.1': 1, 'FDP_RIP.1': 1, 'FDP_SDI': 2, 'FDP_SDI.2.1': 1, 'FDP_SDI.2.2': 2, 'FDP_SDI.1': 1}, 'FIA': {'FIA_ATD': 3, 'FIA_AFL': 3, 'FIA_UAU': 5, 'FIA_UID': 3, 'FIA_USB': 3, 'FIA_ATD.1': 11, 'FIA_AFL.1': 6, 'FIA_UAU.2': 6, 'FIA_UAU.5': 5, 'FIA_UAU.6': 6, 'FIA_UID.2': 10, 'FIA_USB.1': 6, 'FIA_UID.1': 8, 'FIA_ATD.1.1': 1, 'FIA_AFL.1.1': 1, 'FIA_AFL.1.2': 1, 'FIA_UAU.1': 2, 'FIA_UAU.2.1': 1, 'FIA_UAU.5.1': 1, 'FIA_UAU.5.2': 1, 'FIA_UAU.6.1': 1, 'FIA_UID.2.1': 1, 'FIA_USB.1.1': 1, 'FIA_USB.1.2': 1, 'FIA_USB.1.3': 1}, 'FMT': {'FMT_SMR': 3, 'FMT_MOF.1': 6, 'FMT_SMF.1': 18, 'FMT_SMR.1': 25, 'FMT_MSA': 44, 'FMT_MSA.3': 11, 'FMT_MOF': 1, 'FMT_MOF.1.1': 1, 'FMT_SMF': 2, 'FMT_SMF.1.1': 1, 'FMT_SMR.1.1': 1, 'FMT_SMR.1.2': 1, 'FMT_MSA.1': 10}, 'FPR': {'FPR_CON': 6, 'FPR_CON.1': 9, 'FPR_PSE': 2, 'FPR_CON.1.2': 4, 'FPR_CON.1.1': 2, 'FPR_PSE.1': 7, 'FPR_PSE.1.1': 1, 'FPR_PSE.1.2': 1, 'FPR_PSE.1.3': 1}, 'FPT': {'FPT_FLS': 3, 'FPT_RPL': 3, 'FPT_STM': 3, 'FPT_TST': 3, 'FPT_FLS.1': 10, 'FPT_RPL.1': 6, 'FPT_STM.1': 18, 'FPT_TST.1': 8, 'FPT_PHP.1': 6, 'FPT_FLS.1.1': 1, 'FPT_RPL.1.1': 1, 'FPT_RPL.1.2': 1, 'FPT_STM.1.1': 1, 'FPT_TST.1.1': 1, 'FPT_TST.1.2': 1, 'FPT_TST.1.3': 1, 'FPT_PHP': 1, 'FPT_PHP.1.1': 1, 'FPT_PHP.1.2': 1}, 'FTP': {'FTP_ITC': 23, 'FTP_ITC.1': 8}}, 'cc_claims': {'OE': {'OE.SM': 3}, 'OSP': {'OSP.SM': 4}}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 16, 'AES-': 1}}, 'constructions': {'MAC': {'HMAC': 2, 'CMAC': 1}}}, 'asymmetric_crypto': {'ECC': {'ECDSA': {'ECDSA': 1}, 'ECC': {'ECC': 2}}, 'FF': {'DH': {'Diffie-Hellman': 1}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA-256': 2, 'SHA-384': 2, 'SHA-512': 1, 'SHA-2': 3}}, 'JH': {'JH': 1}}, 'crypto_scheme': {'MAC': {'MAC': 8}, 'KA': {'Key agreement': 2, 'Key Agreement': 3}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 44, 'TLSv1.2': 2}}, 'PACE': {'PACE': 1}, 'VPN': {'VPN': 1}}, 'randomness': {'TRNG': {'TRNG': 3}}, 'cipher_mode': {'GCM': {'GCM': 3}}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {'TLS': {'TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256': 3, 'TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384': 3, 'TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256': 3, 'TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384': 3}}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'FI': {'physical tampering': 3, 'malfunction': 3}}, 'technical_report_id': {'BSI': {'BSI TR-03109-1': 2, 'BSI TR-03111': 1, 'BSI TR-03116-3': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS 180-4': 1, 'FIPS 197': 1}, 'NIST': {'NIST SP 800-38A': 1, 'NIST SP 800-38D': 1}, 'RFC': {'RFC-5289': 3, 'RFC-5246': 3, 'RFC-2104': 2, 'RFC-3394': 2, 'RFC-5084': 2, 'RFC-5652': 3, 'RFC-4493': 3, 'RFC 2104': 1, 'RFC 3394': 1, 'RFC 4493': 1, 'RFC 5084': 1, 'RFC 5246': 1, 'RFC 5289': 1, 'RFC 5652': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}.
    • The cert_keywords property was set to {'cc_cert_id': {'DE': {'BSI-DSZ-CC-1000-2023': 1}}, 'cc_protection_profile_id': {}, 'cc_security_level': {'EAL': {'EAL 4': 2, 'EAL 5': 1, 'EAL 2': 1, 'EAL 4 augmented': 1}}, 'cc_sar': {'ALC': {'ALC_FLR.2': 1, 'ALC_FLR': 1}, 'AVA': {'AVA_VAN.5': 1}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {}, 'asymmetric_crypto': {}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'ISO': {'ISO/IEC 15408': 2, 'ISO/IEC 18045': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}.
    • The report_filename property was set to 1000a_pdf.pdf.
    • The st_filename property was set to 1000b_pdf.pdf.
    • The cert_filename property was set to 1000c_pdf.pdf.

    The computed heuristics were updated.

    • The cert_lab property was set to ['BSI'].
    • The cert_id property was set to BSI-DSZ-CC-1000-2023.
    • The st_references property was updated, with the {'directly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-1003-2018']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-1003-2018', 'ANSSI-CC-2017/54', 'BSI-DSZ-CC-0891-V2-2016']}} data.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]} values added.
  • 17.08.2024 The certificate data changed.
    Certificate changed

    The report_link was updated.

    • The new value is https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000a_pdf.pdf.

    The st_link was updated.

    • The new value is https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000b_pdf.pdf.

    The state of the certificate object was updated.

    • The report property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.
    • The st property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.

    The PDF extraction data was updated.

    • The report_metadata property was set to None.
    • The st_metadata property was set to None.
    • The report_frontpage property was set to None.
    • The report_keywords property was set to None.
    • The st_keywords property was set to None.
    • The report_filename property was set to None.
    • The st_filename property was set to None.

    The computed heuristics were updated.

    • The cert_lab property was set to None.
    • The cert_id property was set to None.
    • The st_references property was updated, with the {'directly_referencing': None, 'indirectly_referencing': None} data.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]} values discarded.
  • 12.08.2024 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The cert property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.

    The PDF extraction data was updated.

    • The cert_metadata property was set to None.
    • The cert_keywords property was set to None.
    • The cert_filename property was set to None.

    The computed heuristics were updated.

    • The st_references property was updated, with the {'indirectly_referencing': {'__discard__': {'_type': 'Set', 'elements': ['ANSSI-CC-2017/54', 'BSI-DSZ-CC-0891-V2-2016']}}} data.
  • 23.07.2024 The certificate was first processed.
    New certificate

    A new Common Criteria certificate with the product name Secure Smart Grid Hub (SGH-S), V1.00 was processed.

Raw data

{
  "_type": "sec_certs.sample.cc.CCCertificate",
  "category": "Other Devices and Systems",
  "cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000c_pdf.pdf",
  "dgst": "8624af6c59deae47",
  "heuristics": {
    "_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
    "annotated_references": null,
    "cert_id": "BSI-DSZ-CC-1000-2023",
    "cert_lab": [
      "BSI"
    ],
    "cpe_matches": null,
    "direct_transitive_cves": null,
    "extracted_sars": {
      "_type": "Set",
      "elements": [
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_CMC",
          "level": 4
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_OBJ",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_INT",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_FLR",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_DEL",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_IMP",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_SPD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_ARC",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AGD_OPE",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_LCD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_CCL",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_FUN",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_COV",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AVA_VAN",
          "level": 5
        }
      ]
    },
    "extracted_versions": {
      "_type": "Set",
      "elements": [
        "1.00"
      ]
    },
    "indirect_transitive_cves": null,
    "next_certificates": [],
    "prev_certificates": [],
    "related_cves": null,
    "report_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "scheme_data": {
      "category": "Intelligent measuring systems",
      "cert_id": "BSI-DSZ-CC-1000-2023",
      "certification_date": "2023-09-11",
      "enhanced": {
        "applicant": "EFR GmbH Nymphenburger Stra\u00dfe 20b 80335 M\u00fcnchen",
        "assurance_level": "EAL4+,ALC_FLR.2,AVA_VAN.5",
        "cert_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1000c_pdf.pdf?__blob=publicationFile\u0026v=2",
        "certification_date": "2023-09-11",
        "description": "The TOE is the security functionality of a Smart Meter Gateway that serves as the communi-cation unit between devices of private and commercial consumers and commodity industry service providers (e.g., electricity, gas, water, etc.). It also collects, processes and stores Meter Data and is responsible for the distribution of this data to external entities",
        "entries": [
          {
            "description": "(National Metrology Institute) requirements.",
            "id": "BSI-DSZ-CC-1000-2023-MA-01"
          }
        ],
        "evaluation_facility": "SRC Security Research \u0026 Consulting GmbH",
        "expiration_date": "2031-09-10",
        "product": "Secure Smart Grid Hub (SGH-S), V1.00",
        "protection_profile": "Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI-CC-PP-0073-2014",
        "report_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1000a_pdf.pdf?__blob=publicationFile\u0026v=2",
        "target_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1000b_pdf.pdf?__blob=publicationFile\u0026v=2"
      },
      "product": "Secure Smart Grid Hub (SGH-S), V1.00",
      "subcategory": "(Smart Meter Gateway)",
      "url": "https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_Gateway/1000.html",
      "vendor": "EFR GmbH"
    },
    "st_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": {
        "_type": "Set",
        "elements": [
          "BSI-DSZ-CC-1003-2018"
        ]
      },
      "indirectly_referenced_by": null,
      "indirectly_referencing": {
        "_type": "Set",
        "elements": [
          "BSI-DSZ-CC-1003-2018",
          "BSI-DSZ-CC-0891-V2-2016",
          "ANSSI-CC-2017/54"
        ]
      }
    },
    "verified_cpe_matches": null
  },
  "maintenance_updates": {
    "_type": "Set",
    "elements": [
      {
        "_type": "sec_certs.sample.cc.CCCertificate.MaintenanceReport",
        "maintenance_date": "2024-01-16",
        "maintenance_report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000ma1a_pdf.pdf",
        "maintenance_st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000ma1b_pdf.pdf",
        "maintenance_title": "Secure Smart Grid Hub (SGH-S) in the variants SGH-S-AL1-B-100 \u0026 SGH-S-AM1-B-100, V1.01"
      }
    ]
  },
  "manufacturer": "EFR GmbH",
  "manufacturer_web": "https://www.efr.de",
  "name": "Secure Smart Grid Hub (SGH-S), V1.00",
  "not_valid_after": "2031-09-10",
  "not_valid_before": "2023-09-11",
  "pdf_data": {
    "_type": "sec_certs.sample.cc.CCCertificate.PdfData",
    "cert_filename": "1000c_pdf.pdf",
    "cert_frontpage": null,
    "cert_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {
        "DE": {
          "BSI-DSZ-CC-1000-2023": 1
        }
      },
      "cc_claims": {},
      "cc_protection_profile_id": {},
      "cc_sar": {
        "ALC": {
          "ALC_FLR": 1,
          "ALC_FLR.2": 1
        },
        "AVA": {
          "AVA_VAN.5": 1
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 2": 1,
          "EAL 4": 2,
          "EAL 4 augmented": 1,
          "EAL 5": 1
        }
      },
      "cc_sfr": {},
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {},
      "standard_id": {
        "ISO": {
          "ISO/IEC 15408": 2,
          "ISO/IEC 18045": 2
        }
      },
      "symmetric_crypto": {},
      "technical_report_id": {},
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "cert_metadata": {
      "/Author": "Federal Office for Information Security",
      "/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR\"",
      "/Subject": "Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR",
      "/Title": "Certification Report BSI-DSZ-CC-1000-2023",
      "pdf_file_size_bytes": 339208,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 1
    },
    "report_filename": "1000a_pdf.pdf",
    "report_frontpage": {
      "DE": {
        "cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2 valid until: 10 September 2031",
        "cc_version": "PP conformant Common Criteria Part 2 extended",
        "cert_id": "BSI-DSZ-CC-1000-2023",
        "cert_item": "Secure Smart Grid Hub (SGH-S) V1.00",
        "cert_lab": "BSI",
        "developer": "EFR GmbH",
        "match_rules": [
          "(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
        ],
        "ref_protection_profiles": "Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014"
      }
    },
    "report_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 3
          }
        }
      },
      "cc_cert_id": {
        "DE": {
          "BSI-DSZ-CC-1000-2023": 13
        }
      },
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0073": 1,
          "BSI-CC-PP-0073-2014": 3,
          "BSI-CC-PP-0077-V2-2015": 2
        }
      },
      "cc_sar": {
        "ALC": {
          "ALC_CMS": 1,
          "ALC_FLR": 3,
          "ALC_FLR.2": 4
        },
        "ATE": {
          "ATE_COV": 1,
          "ATE_DPT": 1,
          "ATE_IND": 1
        },
        "AVA": {
          "AVA_VAN.5": 5
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 1": 1,
          "EAL 2": 3,
          "EAL 4": 8,
          "EAL 4 augmented": 3,
          "EAL 5": 3,
          "EAL 5+": 1,
          "EAL 6": 1
        }
      },
      "cc_sfr": {
        "FCS": {
          "FCS_CKM.1": 1
        },
        "FMT": {
          "FMT_SMR.1": 1
        }
      },
      "certification_process": {
        "ConfidentialDocument": {
          "ALC_CMS \u201cKonfigurations-Management-Scope Kon- figurationsliste\u201d, v1.13, 30.08.2023, EFR GmbH (confidential document) [11] Servicetechniker Handbuch f\u00fcr das Smart-Meter-Gateway (SMGW) Secure Smart Grid Hub EFR SGH-S": 1,
          "ID BSI- DSZ-CC-1000, Version 1.3.2, 06.09.2023, SRC Security Research \u0026 Consulting GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014": 1,
          "being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1
        },
        "OutOfScope": {
          "2. Multiple Communication Modules for LTE exist, however these are non-TOE components and as such out of scope for this certification. 9. Results of the Evaluation 9.1. CC specific results The Evaluation": 1,
          "out of scope": 1
        }
      },
      "cipher_mode": {
        "CBC": {
          "CBC": 1
        },
        "GCM": {
          "GCM": 3
        }
      },
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {
        "SSH": {
          "SSH": 1
        },
        "TLS": {
          "TLS": {
            "TLS": 7
          }
        }
      },
      "crypto_scheme": {
        "KA": {
          "Key Agreement": 2
        },
        "MAC": {
          "MAC": 1
        }
      },
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {
        "SRC": {
          "SRC Security Research \u0026 Consulting": 1
        }
      },
      "hash_function": {
        "SHA": {
          "SHA2": {
            "SHA-256": 2,
            "SHA-384": 1,
            "SHA-512": 1,
            "SHA256": 5
          }
        }
      },
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "TRNG": {
          "TRNG": 1
        }
      },
      "side_channel_analysis": {
        "FI": {
          "malfunction": 1,
          "physical tampering": 1
        },
        "SCA": {
          "side channel": 1
        }
      },
      "standard_id": {
        "BSI": {
          "AIS 32": 1,
          "AIS 34": 2,
          "AIS 46": 2,
          "AIS 48": 2
        },
        "FIPS": {
          "FIPS 180-4": 1,
          "FIPS 197": 3
        },
        "ISO": {
          "ISO/IEC 15408": 4,
          "ISO/IEC 17065": 2,
          "ISO/IEC 18033-": 1,
          "ISO/IEC 18045": 4
        },
        "RFC": {
          "RFC 2104": 2,
          "RFC 3394": 2,
          "RFC 4493": 3,
          "RFC 5084": 3,
          "RFC 5246": 1,
          "RFC 5289": 4,
          "RFC 5652": 3,
          "RFC-2104": 1,
          "RFC-3394": 1,
          "RFC4493": 1,
          "RFC5246": 1
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 9,
            "AES-": 1
          }
        },
        "constructions": {
          "MAC": {
            "CMAC": 1,
            "HMAC": 2
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI 7148": 1,
          "BSI TR-02102-1": 1,
          "BSI TR-03111": 1,
          "BSI TR-03116": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "report_metadata": {
      "/Author": "Federal Office for Information Security",
      "/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR\"",
      "/Subject": "Common Criteria, Certification, Zertifizierung, Smart Meter Gateway, SMGW, EFR",
      "/Title": "Certification Report BSI-DSZ-CC-1000-2023",
      "pdf_file_size_bytes": 492094,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": [
          "https://www.sogis.eu/",
          "https://www.commoncriteriaportal.org/",
          "https://www.bsi.bund.de/",
          "https://www.bsi.bund.de/zertifizierung",
          "http://www.commoncriteriaportal.org/",
          "https://www.bsi.bund.de/zertifizierungsreporte",
          "https://www.bsi.bund.de/AIS",
          "http://www.commoncriteriaportal.org/cc/"
        ]
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 26
    },
    "st_filename": "1000b_pdf.pdf",
    "st_frontpage": null,
    "st_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 2
          },
          "ECDSA": {
            "ECDSA": 1
          }
        },
        "FF": {
          "DH": {
            "Diffie-Hellman": 1
          }
        }
      },
      "cc_cert_id": {
        "DE": {
          "BSI-DSZ-CC-1003-": 1,
          "BSI-DSZ-CC-1003-2018": 2
        }
      },
      "cc_claims": {
        "OE": {
          "OE.SM": 3
        },
        "OSP": {
          "OSP.SM": 4
        }
      },
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0073-": 1,
          "BSI-CC-PP-0073-2014": 5,
          "BSI-CC-PP-0077-": 1,
          "BSI-CC-PP-0077-2015": 2,
          "BSI-CC-PP-0077-V2-2015": 1
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC.1": 1,
          "ADV_IMP.1": 1
        },
        "AGD": {
          "AGD_OPE.1": 1
        },
        "ALC": {
          "ALC_CMC.4": 1,
          "ALC_DEL.1": 1,
          "ALC_FLR.2": 5,
          "ALC_LCD.1": 1
        },
        "ASE": {
          "ASE_CCL": 2,
          "ASE_CCL.1": 1,
          "ASE_INT.1": 1,
          "ASE_OBJ": 2,
          "ASE_OBJ.2": 1,
          "ASE_SPD": 3,
          "ASE_SPD.1": 1
        },
        "ATE": {
          "ATE_COV.2": 1,
          "ATE_FUN.1": 1
        },
        "AVA": {
          "AVA_VAN.5": 6
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 4": 4,
          "EAL 4 augmented": 1,
          "EAL4": 1,
          "EAL4 augmented": 1
        }
      },
      "cc_sfr": {
        "FAU": {
          "FAU_ARP": 9,
          "FAU_GEN": 30,
          "FAU_GEN.1": 22,
          "FAU_GEN.2": 6,
          "FAU_GEN.2.1": 1,
          "FAU_SAA": 9,
          "FAU_SAA.1": 5,
          "FAU_SAR": 21,
          "FAU_SAR.1": 9,
          "FAU_STG": 23,
          "FAU_STG.1": 8,
          "FAU_STG.2": 10,
          "FAU_STG.2.1": 1,
          "FAU_STG.2.2": 1,
          "FAU_STG.2.3": 2,
          "FAU_STG.3": 3,
          "FAU_STG.4": 3,
          "FAU_STG.4.1": 1
        },
        "FCO": {
          "FCO_NRO": 3,
          "FCO_NRO.1": 1,
          "FCO_NRO.2": 8,
          "FCO_NRO.2.1": 1,
          "FCO_NRO.2.2": 1,
          "FCO_NRO.2.3": 1
        },
        "FCS": {
          "FCS_CKM": 48,
          "FCS_CKM.1": 6,
          "FCS_CKM.2": 5,
          "FCS_CKM.4": 28,
          "FCS_CKM.4.1": 2,
          "FCS_COP": 49,
          "FCS_COP.1": 10
        },
        "FDP": {
          "FDP_ACC": 2,
          "FDP_ACC.1": 9,
          "FDP_ACC.2": 8,
          "FDP_ACC.2.1": 1,
          "FDP_ACC.2.2": 1,
          "FDP_ACF": 1,
          "FDP_ACF.1": 7,
          "FDP_ACF.1.1": 1,
          "FDP_ACF.1.2": 1,
          "FDP_ACF.1.3": 1,
          "FDP_ACF.1.4": 1,
          "FDP_IFC": 24,
          "FDP_IFC.1": 12,
          "FDP_IFC.2": 4,
          "FDP_IFF": 20,
          "FDP_IFF.1": 22,
          "FDP_IFF.1.3": 1,
          "FDP_ITC.1": 12,
          "FDP_ITC.2": 12,
          "FDP_RIP": 2,
          "FDP_RIP.1": 1,
          "FDP_RIP.2": 7,
          "FDP_RIP.2.1": 1,
          "FDP_SDI": 2,
          "FDP_SDI.1": 1,
          "FDP_SDI.2": 5,
          "FDP_SDI.2.1": 1,
          "FDP_SDI.2.2": 2
        },
        "FIA": {
          "FIA_AFL": 3,
          "FIA_AFL.1": 6,
          "FIA_AFL.1.1": 1,
          "FIA_AFL.1.2": 1,
          "FIA_ATD": 3,
          "FIA_ATD.1": 11,
          "FIA_ATD.1.1": 1,
          "FIA_UAU": 5,
          "FIA_UAU.1": 2,
          "FIA_UAU.2": 6,
          "FIA_UAU.2.1": 1,
          "FIA_UAU.5": 5,
          "FIA_UAU.5.1": 1,
          "FIA_UAU.5.2": 1,
          "FIA_UAU.6": 6,
          "FIA_UAU.6.1": 1,
          "FIA_UID": 3,
          "FIA_UID.1": 8,
          "FIA_UID.2": 10,
          "FIA_UID.2.1": 1,
          "FIA_USB": 3,
          "FIA_USB.1": 6,
          "FIA_USB.1.1": 1,
          "FIA_USB.1.2": 1,
          "FIA_USB.1.3": 1
        },
        "FMT": {
          "FMT_MOF": 1,
          "FMT_MOF.1": 6,
          "FMT_MOF.1.1": 1,
          "FMT_MSA": 44,
          "FMT_MSA.1": 10,
          "FMT_MSA.3": 11,
          "FMT_SMF": 2,
          "FMT_SMF.1": 18,
          "FMT_SMF.1.1": 1,
          "FMT_SMR": 3,
          "FMT_SMR.1": 25,
          "FMT_SMR.1.1": 1,
          "FMT_SMR.1.2": 1
        },
        "FPR": {
          "FPR_CON": 6,
          "FPR_CON.1": 9,
          "FPR_CON.1.1": 2,
          "FPR_CON.1.2": 4,
          "FPR_PSE": 2,
          "FPR_PSE.1": 7,
          "FPR_PSE.1.1": 1,
          "FPR_PSE.1.2": 1,
          "FPR_PSE.1.3": 1
        },
        "FPT": {
          "FPT_FLS": 3,
          "FPT_FLS.1": 10,
          "FPT_FLS.1.1": 1,
          "FPT_PHP": 1,
          "FPT_PHP.1": 6,
          "FPT_PHP.1.1": 1,
          "FPT_PHP.1.2": 1,
          "FPT_RPL": 3,
          "FPT_RPL.1": 6,
          "FPT_RPL.1.1": 1,
          "FPT_RPL.1.2": 1,
          "FPT_STM": 3,
          "FPT_STM.1": 18,
          "FPT_STM.1.1": 1,
          "FPT_TST": 3,
          "FPT_TST.1": 8,
          "FPT_TST.1.1": 1,
          "FPT_TST.1.2": 1,
          "FPT_TST.1.3": 1
        },
        "FTP": {
          "FTP_ITC": 23,
          "FTP_ITC.1": 8
        }
      },
      "certification_process": {},
      "cipher_mode": {
        "GCM": {
          "GCM": 3
        }
      },
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {
        "PACE": {
          "PACE": 1
        },
        "TLS": {
          "TLS": {
            "TLS": 44,
            "TLSv1.2": 2
          }
        },
        "VPN": {
          "VPN": 1
        }
      },
      "crypto_scheme": {
        "KA": {
          "Key Agreement": 3,
          "Key agreement": 2
        },
        "MAC": {
          "MAC": 8
        }
      },
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {
        "JH": {
          "JH": 1
        },
        "SHA": {
          "SHA2": {
            "SHA-2": 3,
            "SHA-256": 2,
            "SHA-384": 2,
            "SHA-512": 1
          }
        }
      },
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "TRNG": {
          "TRNG": 3
        }
      },
      "side_channel_analysis": {
        "FI": {
          "malfunction": 3,
          "physical tampering": 3
        }
      },
      "standard_id": {
        "FIPS": {
          "FIPS 180-4": 1,
          "FIPS 197": 1
        },
        "NIST": {
          "NIST SP 800-38A": 1,
          "NIST SP 800-38D": 1
        },
        "RFC": {
          "RFC 2104": 1,
          "RFC 3394": 1,
          "RFC 4493": 1,
          "RFC 5084": 1,
          "RFC 5246": 1,
          "RFC 5289": 1,
          "RFC 5652": 1,
          "RFC-2104": 2,
          "RFC-3394": 2,
          "RFC-4493": 3,
          "RFC-5084": 2,
          "RFC-5246": 3,
          "RFC-5289": 3,
          "RFC-5652": 3
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 16,
            "AES-": 1
          }
        },
        "constructions": {
          "MAC": {
            "CMAC": 1,
            "HMAC": 2
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI TR-03109-1": 2,
          "BSI TR-03111": 1,
          "BSI TR-03116-3": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {
        "TLS": {
          "TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256": 3,
          "TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256": 3,
          "TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384": 3,
          "TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384": 3
        }
      },
      "vendor": {},
      "vulnerability": {}
    },
    "st_metadata": {
      "/Author": "EFR GmbH",
      "/Subject": "Common Criteria Evaluation",
      "/Title": "Security Target EFR SGH-S",
      "pdf_file_size_bytes": 1849024,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 94
    }
  },
  "protection_profiles": {
    "_type": "Set",
    "elements": [
      {
        "_type": "sec_certs.sample.protection_profile.ProtectionProfile",
        "pp_eal": "EAL4+",
        "pp_ids": {
          "_type": "Set",
          "elements": [
            "SMARTMETERGATEWAYPP_V1.3"
          ]
        },
        "pp_link": "https://www.commoncriteriaportal.org/files/ppfiles/pp0073b_pdf.pdf",
        "pp_name": "Protection Profile for the Gateway of a Smart Metering System"
      }
    ]
  },
  "report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000a_pdf.pdf",
  "scheme": "DE",
  "security_level": {
    "_type": "Set",
    "elements": [
      "AVA_VAN.5",
      "ALC_FLR.2",
      "EAL4+"
    ]
  },
  "st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1000b_pdf.pdf",
  "state": {
    "_type": "sec_certs.sample.cc.CCCertificate.InternalState",
    "cert": {
      "_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "0415a2a4135ec0c104c98563d2bb53128b4f325793b309521286778102fd8f1a",
      "txt_hash": "6f21749fdb90fe818f593cea73c31b4b5e4ad0a855413b23edf4a65b00a347bb"
    },
    "report": {
      "_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "57b155fe20efc25f3836337c59ac1164724520abc30588f29866132b703456c3",
      "txt_hash": "a2a510aa6f2651e8e8beacd81fc6f74c7242df981100703e46b7aa7d98db895a"
    },
    "st": {
      "_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "0a5f42e988f683a33db28884db26fbb433663de623f9554b8736c38e7c8bf9bf",
      "txt_hash": "6ecf1f3fa8acc96b7591606fc90abf6f2f24928f242723d43e8172528186fd10"
    }
  },
  "status": "active"
}