Sagem Sécurité Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC
CSV information ?
Status | archived |
---|---|
Valid from | 09.04.2010 |
Valid until | 01.09.2019 |
Scheme | 🇫🇷 FR |
Manufacturer | Sagem Sécurité / STMicroelectronics |
Category | ICs, Smart Cards and Smart Card-Related Devices and Systems |
Security level | EAL4+, AVA_VAN.5, ALC_DVS.2 |
Heuristics summary ?
Certificate ?
Certification report ?
Extracted keywords
Asymmetric Algorithms
ECCLibraries
NesLib v2.0Vendor
STM, SAGEMSecurity level
EAL 4, EAL4, EAL6, EAL7, EAL 1, EAL 3, EAL 5, EAL 7, EAL 4 augmented, ITSEC E6 andSecurity Assurance Requirements (SAR)
ADV_ARC, ADV_FSP, ADV_IMP, ADV_INT, ADV_SPM, ADV_TDS, AGD_OPE, AGD_PRE, ALC_DVS.2, ALC_FLR.1, ALC_FLR, ALC_CMC, ALC_CMS, ALC_DEL, ALC_DVS, ALC_TAT, ATE_DPT.2, ATE_DPT.1, ATE_COV, ATE_DPT, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VAN, ASE_CCL, ASE_ECD, ASE_INT, ASE_OBJ, ASE_REQ, ASE_SPD, ASE_TSSProtection profiles
BSI-CC-PP-0056-2009, BSI-PP-0035-2007Certificates
ANSSI-CC-2010/17, ANSSI-CC-2010/02, ANSSI-2010/02-M01, ANSSI-CC-2009/61Evaluation facilities
CESTI, CEA - LETIStandards
ICAO, CCMB-2006-09-001, CCMB-2007-09-002, CCMB-2007-09-003, CCMB-2007-09-004File metadata
Creation date | D:20100430151153+02'00' |
---|---|
Modification date | D:20100430151153+02'00' |
Pages | 18 |
Producer | Acrobat Distiller 8.0.0 (Windows) |
Frontpage
Certificate ID | ANSSI-CC-2010/17 |
---|---|
Certified item | CC IDeal Citiz SmartCard (on SB23YR80B |
Certification lab | CEA - LETI 17 rue des martyrs, 38054 Grenoble Cedex 9, France Phone: +33 (0)4 38 78 40 87, email : [email protected] |
Developer | SAGEM Sécurité Etablissement d’Osny, 18 Chaussée Jules César, 95520 Osny, France ST Microelectronics 29 Boulevard Romain Rolland, 75669 Paris cedex 14, France Sponsor SAGEM Sécurité Etablissement d’Osny, 18 Chaussée Jules César, 95520 Osny, France |
References
Outgoing- ANSSI-CC-2010/02 - archived - STMicroelectronics SA23YR48/80B and SB23YR48/80B Secure Microcontrollers, including the cryptographic library Neslib v2.0 or v3.0, in SA or SB configuration
- ANSSI-CC-2009/61 - archived - CC IDeal Pass Passport (on SB23YR80A), version 1.3.3
- ANSSI-CC-2010/32 - archived - Sagem Securite CC IDeal Citiz SmartCard (on SB23YR80B), version 1.4
Security target ?
Extracted keywords
Symmetric Algorithms
DES, Triple-DES, TDES, KMACAsymmetric Algorithms
RSA 1024, ECDH, ECDSA, ECC, Diffie-Hellman, DHHash functions
SHA-1, SHA224, SHA-256, SHA-224Schemes
MAC, Key AgreementRandomness
RNGBlock cipher modes
CBCIC data groups
EF.DG3, EF.DG6, EF.DG15, EF.DG14, EF.DG4, EF.DG1, EF.DG2, EF.DG5, EF.DG16, EF.DG13, EF.COM, EF.SODSecurity level
EAL4, EAL4 augmentedClaims
T.CHIP_ID, A.MRTD_, OE.MRTD_, OE.BAC_PP, OE.BAC-PPSecurity Assurance Requirements (SAR)
ADV_COMP.1, ADV_ARC.1, ALC_DVS.2, ALC_COMP.1, ATE_COMP.1, AVA_VAN.5, AVA_VAN, AVA_COMP.1, AVA_VAN.3, APE_SRE, ASE_COMP.1Security Functional Requirements (SFR)
FAU_SAS, FAU_GEN, FAU_SAS.1, FAU_SAS.1.1, FCS_RND, FCS_COP, FCS_CKM.1, FCS_RND.1, FCS_RND.1.1, FCS_CKM, FCS_CKM.1.1, FCS_CKM.4, FCS_CKM.4.1, FCS_COP.1, FCS_COP.1.1, FDP_ACF, FDP_ACC, FDP_ACC.1, FDP_ACC.1.1, FDP_ACF.1, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_UCT, FDP_UCT.1, FDP_UCT.1.1, FDP_UIT, FDP_UIT.1, FDP_UIT.1.1, FDP_UIT.1.2, FIA_API, FIA_SOS.2, FIA_API.1, FIA_API.1.1, FIA_UAU.4, FIA_UAU, FIA_UID, FIA_UID.1, FIA_UID.1.1, FIA_UID.1.2, FIA_UAU.1, FIA_UAU.1.1, FIA_UAU.1.2, FIA_UAU.4.1, FIA_UAU.5, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UAU.6, FIA_UAU.6.1, FMT_LIM, FMT_MTD, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_MTD.3, FMT_SMF.1, FMT_SMR.1, FMT_SMF, FMT_SMF.1.1, FMT_SMR, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MTD.1, FMT_MTD.1.1, FMT_MTD.3.1, FPT_FLS.1, FPT_TST.1, FPT_PHP.3, FPT_FLS, FPT_FLS.1.1, FPT_PHP, FPT_PHP.3.1, FPT_TST, FPT_TST.1.1, FPT_TST.2.1, FPT_TST.3.1Protection profiles
BSI-CC-PP-0056, BSI-PP-0056, BSI-PP-0055, BSI-PP-0002-2001Certificates
DCSSI-2010/02Side-channel analysis
physical probing, side channel, DPA, SPA, timing attacks, Physical Tampering, physical tampering, Physical tampering, Malfunction, malfunction, fault injection, Fault injection, reverse engineeringStandards
FIPS 180-2, FIPS 46-3, FIPS PUB 46-3, PKCS#3, AIS31, RFC 2631, RFC3369, ISO/IEC 7816-2, ISO/IEC 7816-4, ISO/IEC 15946, ICAO, CCMB-2006-09-001, CCMB-2007-09-002, CCMB-2007-09-003, CCMB-2007-09-004Technical reports
BSI TR-03110, BSI 2006File metadata
Creation date | D:20100427185324+02'00' |
---|---|
Modification date | D:20100427185324+02'00' |
Pages | 85 |
Producer | GPL Ghostscript 8.54 |
References
Outgoing- ANSSI-CC-2010/02 - archived - STMicroelectronics SA23YR48/80B and SB23YR48/80B Secure Microcontrollers, including the cryptographic library Neslib v2.0 or v3.0, in SA or SB configuration
Heuristics ?
Extracted SARs
ALC_COMP.1, AVA_COMP.1, ATE_COMP.1, ADV_COMP.1, ALC_DVS.2, ALC_FLR.1, ASE_COMP.1, AVA_VAN.5, ATE_DPT.2, ADV_ARC.1Similar certificates
Scheme data ?
Product | Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC | |
---|---|---|
Url | https://cyber.gouv.fr/produits-certifies/carte-cc-ideal-citiz-sur-composant-sb23yr80b-version-145-application-icao-eac | |
Description | Le produit certifié est la ''Carte CC IDeal Citiz (sur composant SB23YR80B), IDEAL/ST23YR80/1.4.5, Version 1.4.5'' développée par SAGEM Sécurité et ST Microelectronics. Le produit évalué est de type carte à puce duale, avec et sans contact. Il est composé : de trois applications : l'application AIP qui permet de réaliser les opérations de pré-personnalisation et de personna | |
Sponsor | Sagem Sécurité | |
Developer | Sagem Sécurité, ST Microelectronics | |
Cert Id | ANSSI-CC-2010/17 | |
Level | EAL4+ | |
Enhanced | ||
Cert Id | ANSSI-CC-2010/17 | |
Certification Date | 09.04.2010 | |
Category | Cartes à puce | |
Cc Version | Critères Communs version 3.1 | |
Developer | Sagem Sécurité, ST Microelectronics | |
Sponsor | Sagem Sécurité | |
Evaluation Facility | CEA - LETI | |
Level | EAL4+ | |
Protection Profile | BSI-PP-0056-2009 | |
Mutual Recognition | SOG-IS CCRA | |
Augmented | ALC_DVS.2, AVA_VAN.5 | |
Target Link | https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2010-17en.pdf | |
Report Link | https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2010-17en.pdf |
References ?
Updates ?
-
09.11.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was updated, with the
{'product': 'Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC', 'url': 'https://cyber.gouv.fr/produits-certifies/carte-cc-ideal-citiz-sur-composant-sb23yr80b-version-145-application-icao-eac', 'description': 'Le produit certifié est la ''Carte CC IDeal Citiz (sur composant SB23YR80B), IDEAL/ST23YR80/1.4.5, Version 1.4.5'' développée par SAGEM Sécurité et ST Microelectronics. Le produit évalué est de type carte à puce duale, avec et sans contact. Il est composé : de trois applications : l'application AIP qui permet de réaliser les opérations de pré-personnalisation et de personna', 'cert_id': 'ANSSI-CC-2010/17', 'level': 'EAL4+', 'enhanced': {'__update__': {'cert_id': 'ANSSI-CC-2010/17', 'certification_date': '2010-04-09', 'level': 'EAL4+', 'mutual_recognition': 'SOG-IS CCRA', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2010-17en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2010-17en.pdf'}}}
data.
- The scheme_data property was updated, with the
-
14.10.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was set to
{'product': 'Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC', 'url': 'https://cyber.gouv.fr/produits-certifies/carte-cc-ideal-citiz-sur-composant-sb23yr80b-version-145-application-icao-eac-0', 'description': 'Le produit certifié est la « Carte CC IDeal Citiz (sur composant SB23YR80B), IDEAL/ST23YR80/1.4.5, Version 1.4.5 » développée par SAGEM Sécurité et ST Microelectronics.\n\nLe produit certifié est de type carte à puce duale, avec et sans contact. Il est composé :\n- de trois applications :\no l'application AIP qui permet de réaliser les opérations de pré-personnalisation et de personnalisation', 'sponsor': 'Sagem Sécurité', 'developer': 'Sagem Sécurité, ST Microelectronics', 'cert_id': '2010/32', 'level': 'EAL5+', 'enhanced': {'cert_id': '2010/32', 'certification_date': '09/06/2010', 'category': 'Cartes à puce', 'cc_version': 'Critères Communs version 3.1', 'developer': 'Sagem Sécurité, ST Microelectronics', 'sponsor': 'Sagem Sécurité', 'evaluation_facility': 'CEA - LETI', 'level': 'EAL5+', 'protection_profile': 'BSI-PP-0056-2009', 'mutual_recognition': 'SOG-IS\n CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2010-32en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2010-32en.pdf'}}
.
- The scheme_data property was set to
-
02.09.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was set to
None
.
- The scheme_data property was set to
-
22.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'fdd1c6673f30697d17c87b9a496c337afeb378d65e071622328ddcec117c4736', 'txt_hash': '7b73a323c79f33802cb2024c2a26ad8d49af62aa83d2a59d176d64d6af809aa2'}
data. - The st property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '7d54dbf2d061038151d26c82d464e38839a1f9404ef3565b27730933a91ddbde', 'txt_hash': '7053cf5276de96e55dc776d906b5d8afcf7a61149fba5d5269e3718c6ec4efd4'}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
{'pdf_file_size_bytes': 111774, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 18, '/CreationDate': "D:20100430151153+02'00'", '/Keywords': '', '/Producer': 'Acrobat Distiller 8.0.0 (Windows)', '/ModDate': "D:20100430151153+02'00'", 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}
. - The st_metadata property was set to
{'pdf_file_size_bytes': 915483, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 85, '/CreationDate': "D:20100427185324+02'00'", '/Keywords': '', '/Producer': 'GPL Ghostscript 8.54', '/ModDate': "D:20100427185324+02'00'", 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}
. - The report_frontpage property was set to
{'FR': {'match_rules': ['Certification report reference(.+)Product name(.+)Product reference(.+)Protection profile conformity(.+)Evaluation criteria and version(.+)Evaluation level(.+)Developers(.+)Evaluation facility(.+)Recognition arrangements'], 'cert_id': 'ANSSI-CC-2010/17', 'cert_item': 'CC IDeal Citiz SmartCard (on SB23YR80B', 'cert_item_version': ' version IDEAL/ST23YR80/1.4.5, Version 1.4.5', 'ref_protection_profiles': 'PP EAC] Machine Readable Travel Document with “ICAO Application”, Extented Access Control, version 1.10', 'cc_version': 'Common Criteria version 3.1', 'cc_security_level': 'EAL 4 augmented ALC_DVS.2, AVA_VAN.5', 'developer': 'SAGEM Sécurité Etablissement d’Osny, 18 Chaussée Jules César, 95520 Osny, France ST Microelectronics 29 Boulevard Romain Rolland, 75669 Paris cedex 14, France Sponsor SAGEM Sécurité Etablissement d’Osny, 18 Chaussée Jules César, 95520 Osny, France', 'cert_lab': 'CEA - LETI 17 rue des martyrs, 38054 Grenoble Cedex 9, France Phone: +33 (0)4 38 78 40 87, email : [email protected]'}}
. - The report_keywords property was set to
{'cc_cert_id': {'FR': {'ANSSI-CC-2010/17': 19, 'ANSSI-CC-2010/02': 3, 'ANSSI-2010/02-M01': 2, 'ANSSI-CC-2009/61': 2}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0056-2009': 1, 'BSI-PP-0035-2007': 1}}, 'cc_security_level': {'EAL': {'EAL 4': 2, 'EAL4': 3, 'EAL6': 1, 'EAL7': 1, 'EAL 1': 1, 'EAL 3': 1, 'EAL 5': 1, 'EAL 7': 1, 'EAL 4 augmented': 2}, 'ITSEC': {'ITSEC E6 and': 1}}, 'cc_sar': {'ADV': {'ADV_ARC': 1, 'ADV_FSP': 1, 'ADV_IMP': 1, 'ADV_INT': 1, 'ADV_SPM': 1, 'ADV_TDS': 1}, 'AGD': {'AGD_OPE': 1, 'AGD_PRE': 1}, 'ALC': {'ALC_DVS.2': 1, 'ALC_FLR.1': 1, 'ALC_FLR': 2, 'ALC_CMC': 1, 'ALC_CMS': 1, 'ALC_DEL': 1, 'ALC_DVS': 1, 'ALC_TAT': 1}, 'ATE': {'ATE_DPT.2': 1, 'ATE_DPT.1': 1, 'ATE_COV': 1, 'ATE_DPT': 1, 'ATE_FUN': 1, 'ATE_IND': 1}, 'AVA': {'AVA_VAN.5': 1, 'AVA_VAN': 2}, 'ASE': {'ASE_CCL': 1, 'ASE_ECD': 1, 'ASE_INT': 1, 'ASE_OBJ': 1, 'ASE_REQ': 1, 'ASE_SPD': 1, 'ASE_TSS': 1}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {'STMicroelectronics': {'STM': 6}, 'Sagem': {'SAGEM': 10}}, 'eval_facility': {'CESTI': {'CESTI': 2}, 'CEA-LETI': {'CEA - LETI': 1}}, 'symmetric_crypto': {}, 'asymmetric_crypto': {'ECC': {'ECC': {'ECC': 2}}}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {'Neslib': {'NesLib v2.0': 1}}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'ICAO': {'ICAO': 11}, 'CC': {'CCMB-2006-09-001': 1, 'CCMB-2007-09-002': 1, 'CCMB-2007-09-003': 1, 'CCMB-2007-09-004': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}
. - The st_keywords property was set to
{'cc_cert_id': {'FR': {'DCSSI-2010/02': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0056': 1, 'BSI-PP-0056': 1, 'BSI-PP-0055': 1, 'BSI-PP-0002-2001': 1}}, 'cc_security_level': {'EAL': {'EAL4': 3, 'EAL4 augmented': 1}}, 'cc_sar': {'ADV': {'ADV_COMP.1': 1, 'ADV_ARC.1': 1}, 'ALC': {'ALC_DVS.2': 3, 'ALC_COMP.1': 1}, 'ATE': {'ATE_COMP.1': 1}, 'AVA': {'AVA_VAN.5': 4, 'AVA_VAN': 1, 'AVA_COMP.1': 1, 'AVA_VAN.3': 1}, 'APE': {'APE_SRE': 1}, 'ASE': {'ASE_COMP.1': 1}}, 'cc_sfr': {'FAU': {'FAU_SAS': 6, 'FAU_GEN': 1, 'FAU_SAS.1': 7, 'FAU_SAS.1.1': 2}, 'FCS': {'FCS_RND': 8, 'FCS_COP': 10, 'FCS_CKM.1': 2, 'FCS_RND.1': 6, 'FCS_RND.1.1': 2, 'FCS_CKM': 4, 'FCS_CKM.1.1': 1, 'FCS_CKM.4': 2, 'FCS_CKM.4.1': 1, 'FCS_COP.1': 1, 'FCS_COP.1.1': 5}, 'FDP': {'FDP_ACF': 2, 'FDP_ACC': 1, 'FDP_ACC.1': 2, 'FDP_ACC.1.1': 1, 'FDP_ACF.1': 3, 'FDP_ACF.1.1': 1, 'FDP_ACF.1.2': 2, 'FDP_ACF.1.3': 1, 'FDP_ACF.1.4': 1, 'FDP_UCT': 1, 'FDP_UCT.1': 4, 'FDP_UCT.1.1': 1, 'FDP_UIT': 1, 'FDP_UIT.1': 4, 'FDP_UIT.1.1': 1, 'FDP_UIT.1.2': 1}, 'FIA': {'FIA_API': 11, 'FIA_SOS.2': 1, 'FIA_API.1': 5, 'FIA_API.1.1': 3, 'FIA_UAU.4': 4, 'FIA_UAU': 5, 'FIA_UID': 2, 'FIA_UID.1': 1, 'FIA_UID.1.1': 1, 'FIA_UID.1.2': 1, 'FIA_UAU.1': 2, 'FIA_UAU.1.1': 1, 'FIA_UAU.1.2': 1, 'FIA_UAU.4.1': 1, 'FIA_UAU.5': 4, 'FIA_UAU.5.1': 1, 'FIA_UAU.5.2': 1, 'FIA_UAU.6': 2, 'FIA_UAU.6.1': 1}, 'FMT': {'FMT_LIM': 8, 'FMT_MTD': 17, 'FMT_LIM.1': 15, 'FMT_LIM.2': 14, 'FMT_LIM.1.1': 3, 'FMT_LIM.2.1': 4, 'FMT_MTD.3': 5, 'FMT_SMF.1': 3, 'FMT_SMR.1': 3, 'FMT_SMF': 1, 'FMT_SMF.1.1': 1, 'FMT_SMR': 1, 'FMT_SMR.1.1': 2, 'FMT_SMR.1.2': 1, 'FMT_MTD.1': 2, 'FMT_MTD.1.1': 9, 'FMT_MTD.3.1': 1}, 'FPT': {'FPT_FLS.1': 3, 'FPT_TST.1': 5, 'FPT_PHP.3': 4, 'FPT_FLS': 1, 'FPT_FLS.1.1': 1, 'FPT_PHP': 1, 'FPT_PHP.3.1': 1, 'FPT_TST': 1, 'FPT_TST.1.1': 1, 'FPT_TST.2.1': 1, 'FPT_TST.3.1': 1}}, 'cc_claims': {'T': {'T.CHIP_ID': 1}, 'A': {'A.MRTD_': 2}, 'OE': {'OE.MRTD_': 4, 'OE.BAC_PP': 1, 'OE.BAC-PP': 4}}, 'vendor': {}, 'eval_facility': {}, 'symmetric_crypto': {'DES': {'DES': {'DES': 3}, '3DES': {'Triple-DES': 6, 'TDES': 2}}, 'constructions': {'MAC': {'KMAC': 1}}}, 'asymmetric_crypto': {'RSA': {'RSA 1024': 1}, 'ECC': {'ECDH': {'ECDH': 2}, 'ECDSA': {'ECDSA': 2}, 'ECC': {'ECC': 1}}, 'FF': {'DH': {'Diffie-Hellman': 5, 'DH': 3}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA1': {'SHA-1': 3}, 'SHA2': {'SHA224': 1, 'SHA-256': 3, 'SHA-224': 3}}}, 'crypto_scheme': {'MAC': {'MAC': 4}, 'KA': {'Key Agreement': 1}}, 'crypto_protocol': {}, 'randomness': {'RNG': {'RNG': 3}}, 'cipher_mode': {'CBC': {'CBC': 1}}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'SCA': {'physical probing': 4, 'side channel': 1, 'DPA': 2, 'SPA': 1, 'timing attacks': 1}, 'FI': {'Physical Tampering': 4, 'physical tampering': 3, 'Physical tampering': 2, 'Malfunction': 4, 'malfunction': 4, 'fault injection': 2, 'Fault injection': 1}, 'other': {'reverse engineering': 1}}, 'technical_report_id': {'BSI': {'BSI TR-03110': 1, 'BSI 2006': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {'EF': {'EF.DG3': 18, 'EF.DG6': 1, 'EF.DG15': 5, 'EF.DG14': 9, 'EF.DG4': 16, 'EF.DG1': 14, 'EF.DG2': 7, 'EF.DG5': 6, 'EF.DG16': 14, 'EF.DG13': 1, 'EF.COM': 10, 'EF.SOD': 11}}, 'standard_id': {'FIPS': {'FIPS 180-2': 1, 'FIPS 46-3': 1, 'FIPS PUB 46-3': 2}, 'PKCS': {'PKCS#3': 3}, 'BSI': {'AIS31': 2}, 'RFC': {'RFC 2631': 1, 'RFC3369': 1}, 'ISO': {'ISO/IEC 7816-2': 1, 'ISO/IEC 7816-4': 1, 'ISO/IEC 15946': 2}, 'ICAO': {'ICAO': 13}, 'CC': {'CCMB-2006-09-001': 1, 'CCMB-2007-09-002': 1, 'CCMB-2007-09-003': 1, 'CCMB-2007-09-004': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}
. - The report_filename property was set to
ANSSI-CC_2010-17en.pdf
. - The st_filename property was set to
ANSSI-CC-cible_2010-17en.pdf
.
The computed heuristics were updated.
- The cert_lab property was set to
['CEA']
. - The cert_id property was set to
ANSSI-CC-2010/17
. - The st_references property was updated, with the
{'directly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2010/02']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2010/02']}}
data. - The report_references property was updated, with the
{'directly_referenced_by': {'_type': 'Set', 'elements': ['ANSSI-CC-2010/32']}, 'indirectly_referenced_by': {'_type': 'Set', 'elements': ['ANSSI-CC-2010/32', 'ANSSI-CC-2011/62']}, 'directly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2010/02', 'ANSSI-CC-2009/61']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2009/05', 'ANSSI-CC-2009/61', 'ANSSI-CC-2009/26', 'ANSSI-CC-2009/28', 'ANSSI-CC-2009/50', 'ANSSI-CC-2009/06', 'ANSSI-CC-2009/62', 'ANSSI-CC-2010/02', 'ANSSI-CC-2009/51', 'ANSSI-CC-2010/01']}}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AVA_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_FLR', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}]}
values added.
- The report property was updated, with the
-
17.08.2024 The certificate data changed.
Certificate changed
The report_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC_2010-17en.pdf
.
The st_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC-cible_2010-17en.pdf
.
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
None
. - The report_frontpage property was set to
None
. - The report_keywords property was set to
None
. - The report_filename property was set to
None
.
The computed heuristics were updated.
- The cert_lab property was set to
None
. - The cert_id property was set to
None
. - The report_references property was updated, with the
{'directly_referenced_by': None, 'indirectly_referenced_by': None, 'directly_referencing': None, 'indirectly_referencing': None}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_FLR', 'level': 1}]}
values discarded.
- The new value is
-
12.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The st property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data.
The PDF extraction data was updated.
- The st_metadata property was set to
None
. - The st_keywords property was set to
None
. - The st_filename property was set to
None
.
The computed heuristics were updated.
- The st_references property was updated, with the
{'directly_referencing': None, 'indirectly_referencing': None}
data. - The report_references property was updated, with the
{'directly_referencing': {'__discard__': {'_type': 'Set', 'elements': ['ANSSI-CC-2009/61']}}, 'indirectly_referencing': {'__discard__': {'_type': 'Set', 'elements': ['ANSSI-CC-2009/28', 'ANSSI-CC-2009/61']}}}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AVA_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}]}
values discarded. - The scheme_data property was set to
{'product': 'Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC', 'url': 'https://cyber.gouv.fr/produits-certifies/carte-cc-ideal-citiz-sur-composant-sb23yr80b-version-145-application-icao-eac-0', 'description': 'Le produit certifié est la « Carte CC IDeal Citiz (sur composant SB23YR80B), IDEAL/ST23YR80/1.4.5, Version 1.4.5 » développée par SAGEM Sécurité et ST Microelectronics.\n\nLe produit certifié est de type carte à puce duale, avec et sans contact. Il est composé :\n- de trois applications :\no l'application AIP qui permet de réaliser les opérations de pré-personnalisation et de personnalisation', 'sponsor': 'Sagem Sécurité', 'developer': 'Sagem Sécurité, ST Microelectronics', 'cert_id': '2010/32', 'level': 'EAL5+', 'enhanced': {'cert_id': '2010/32', 'certification_date': '09/06/2010', 'category': 'Cartes à puce', 'cc_version': 'Critères Communs version 3.1', 'developer': 'Sagem Sécurité, ST Microelectronics', 'sponsor': 'Sagem Sécurité', 'evaluation_facility': 'CEA - LETI', 'level': 'EAL5+', 'protection_profile': 'BSI-PP-0056-2009', 'mutual_recognition': 'SOG-IS\n CCRA', 'augmented': 'ALC_DVS.2, AVA_VAN.5', 'target_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2010-32en.pdf', 'report_link': 'https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2010-32en.pdf'}}
.
- The st property was updated, with the
-
31.07.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was set to
None
.
- The scheme_data property was set to
-
23.07.2024 The certificate was first processed.
New certificate
A new Common Criteria certificate with the product name Sagem Sécurité Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC was processed.
Raw data
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
"cert_link": null,
"dgst": "75426eeb4747d266",
"heuristics": {
"_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
"annotated_references": null,
"cert_id": "ANSSI-CC-2010/17",
"cert_lab": [
"CEA"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_FLR",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DVS",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_DPT",
"level": 2
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"1.4.5"
]
},
"indirect_transitive_cves": null,
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": {
"_type": "Set",
"elements": [
"ANSSI-CC-2010/32"
]
},
"directly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2010/02",
"ANSSI-CC-2009/61"
]
},
"indirectly_referenced_by": {
"_type": "Set",
"elements": [
"ANSSI-CC-2011/62",
"ANSSI-CC-2010/32"
]
},
"indirectly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2010/01",
"ANSSI-CC-2009/50",
"ANSSI-CC-2009/05",
"ANSSI-CC-2009/06",
"ANSSI-CC-2009/61",
"ANSSI-CC-2010/02",
"ANSSI-CC-2009/28",
"ANSSI-CC-2009/51",
"ANSSI-CC-2009/62",
"ANSSI-CC-2009/26"
]
}
},
"scheme_data": {
"cert_id": "ANSSI-CC-2010/17",
"description": "Le produit certifi\u00e9 est la \u0026#39;\u0026#39;Carte CC IDeal Citiz (sur composant SB23YR80B), IDEAL/ST23YR80/1.4.5, Version 1.4.5\u0026#39;\u0026#39; d\u00e9velopp\u00e9e par SAGEM S\u00e9curit\u00e9 et ST Microelectronics. Le produit \u00e9valu\u00e9 est de type carte \u00e0 puce duale, avec et sans contact. Il est compos\u00e9 : de trois applications : l\u0026#39;application AIP qui permet de r\u00e9aliser les op\u00e9rations de pr\u00e9-personnalisation et de personna",
"developer": "Sagem S\u00e9curit\u00e9, ST Microelectronics",
"enhanced": {
"augmented": "ALC_DVS.2, AVA_VAN.5",
"category": "Cartes \u00e0 puce",
"cc_version": "Crit\u00e8res Communs version 3.1",
"cert_id": "ANSSI-CC-2010/17",
"certification_date": "2010-04-09",
"developer": "Sagem S\u00e9curit\u00e9, ST Microelectronics",
"evaluation_facility": "CEA - LETI",
"level": "EAL4+",
"mutual_recognition": "SOG-IS CCRA",
"protection_profile": "BSI-PP-0056-2009",
"report_link": "https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC_2010-17en.pdf",
"sponsor": "Sagem S\u00e9curit\u00e9",
"target_link": "https://cyber.gouv.fr/sites/default/files/IMG/certificat/ANSSI-CC-cible_2010-17en.pdf"
},
"level": "EAL4+",
"product": "Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC",
"sponsor": "Sagem S\u00e9curit\u00e9",
"url": "https://cyber.gouv.fr/produits-certifies/carte-cc-ideal-citiz-sur-composant-sb23yr80b-version-145-application-icao-eac"
},
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2010/02"
]
},
"indirectly_referenced_by": null,
"indirectly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2010/02"
]
}
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": []
},
"manufacturer": "Sagem S\u00e9curit\u00e9 / STMicroelectronics",
"manufacturer_web": "https://www.st.com/",
"name": "Sagem S\u00e9curit\u00e9 Carte CC IDeal Citiz (sur composant SB23YR80B), version 1.4.5 Application ICAO EAC",
"not_valid_after": "2019-09-01",
"not_valid_before": "2010-04-09",
"pdf_data": {
"_type": "sec_certs.sample.cc.CCCertificate.PdfData",
"cert_filename": null,
"cert_frontpage": null,
"cert_keywords": null,
"cert_metadata": null,
"report_filename": "ANSSI-CC_2010-17en.pdf",
"report_frontpage": {
"FR": {
"cc_security_level": "EAL 4 augmented ALC_DVS.2, AVA_VAN.5",
"cc_version": "Common Criteria version 3.1",
"cert_id": "ANSSI-CC-2010/17",
"cert_item": "CC IDeal Citiz SmartCard (on SB23YR80B",
"cert_item_version": " version IDEAL/ST23YR80/1.4.5, Version 1.4.5",
"cert_lab": "CEA - LETI 17 rue des martyrs, 38054 Grenoble Cedex 9, France Phone: +33 (0)4 38 78 40 87, email : [email protected]",
"developer": "SAGEM S\u00e9curit\u00e9 Etablissement d\u2019Osny, 18 Chauss\u00e9e Jules C\u00e9sar, 95520 Osny, France ST Microelectronics 29 Boulevard Romain Rolland, 75669 Paris cedex 14, France Sponsor SAGEM S\u00e9curit\u00e9 Etablissement d\u2019Osny, 18 Chauss\u00e9e Jules C\u00e9sar, 95520 Osny, France",
"match_rules": [
"Certification report reference(.+)Product name(.+)Product reference(.+)Protection profile conformity(.+)Evaluation criteria and version(.+)Evaluation level(.+)Developers(.+)Evaluation facility(.+)Recognition arrangements"
],
"ref_protection_profiles": "PP EAC] Machine Readable Travel Document with \u201cICAO Application\u201d, Extented Access Control, version 1.10"
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 2
}
}
},
"cc_cert_id": {
"FR": {
"ANSSI-2010/02-M01": 2,
"ANSSI-CC-2009/61": 2,
"ANSSI-CC-2010/02": 3,
"ANSSI-CC-2010/17": 19
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0056-2009": 1,
"BSI-PP-0035-2007": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC": 1,
"ADV_FSP": 1,
"ADV_IMP": 1,
"ADV_INT": 1,
"ADV_SPM": 1,
"ADV_TDS": 1
},
"AGD": {
"AGD_OPE": 1,
"AGD_PRE": 1
},
"ALC": {
"ALC_CMC": 1,
"ALC_CMS": 1,
"ALC_DEL": 1,
"ALC_DVS": 1,
"ALC_DVS.2": 1,
"ALC_FLR": 2,
"ALC_FLR.1": 1,
"ALC_TAT": 1
},
"ASE": {
"ASE_CCL": 1,
"ASE_ECD": 1,
"ASE_INT": 1,
"ASE_OBJ": 1,
"ASE_REQ": 1,
"ASE_SPD": 1,
"ASE_TSS": 1
},
"ATE": {
"ATE_COV": 1,
"ATE_DPT": 1,
"ATE_DPT.1": 1,
"ATE_DPT.2": 1,
"ATE_FUN": 1,
"ATE_IND": 1
},
"AVA": {
"AVA_VAN": 2,
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 3": 1,
"EAL 4": 2,
"EAL 4 augmented": 2,
"EAL 5": 1,
"EAL 7": 1,
"EAL4": 3,
"EAL6": 1,
"EAL7": 1
},
"ITSEC": {
"ITSEC E6 and": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {
"Neslib": {
"NesLib v2.0": 1
}
},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"CEA-LETI": {
"CEA - LETI": 1
},
"CESTI": {
"CESTI": 2
}
},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"CC": {
"CCMB-2006-09-001": 1,
"CCMB-2007-09-002": 1,
"CCMB-2007-09-003": 1,
"CCMB-2007-09-004": 1
},
"ICAO": {
"ICAO": 11
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"STMicroelectronics": {
"STM": 6
},
"Sagem": {
"SAGEM": 10
}
},
"vulnerability": {}
},
"report_metadata": {
"/CreationDate": "D:20100430151153+02\u002700\u0027",
"/Keywords": "",
"/ModDate": "D:20100430151153+02\u002700\u0027",
"/Producer": "Acrobat Distiller 8.0.0 (Windows)",
"pdf_file_size_bytes": 111774,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 18
},
"st_filename": "ANSSI-CC-cible_2010-17en.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 1
},
"ECDH": {
"ECDH": 2
},
"ECDSA": {
"ECDSA": 2
}
},
"FF": {
"DH": {
"DH": 3,
"Diffie-Hellman": 5
}
},
"RSA": {
"RSA 1024": 1
}
},
"cc_cert_id": {
"FR": {
"DCSSI-2010/02": 1
}
},
"cc_claims": {
"A": {
"A.MRTD_": 2
},
"OE": {
"OE.BAC-PP": 4,
"OE.BAC_PP": 1,
"OE.MRTD_": 4
},
"T": {
"T.CHIP_ID": 1
}
},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0056": 1,
"BSI-PP-0002-2001": 1,
"BSI-PP-0055": 1,
"BSI-PP-0056": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_COMP.1": 1
},
"ALC": {
"ALC_COMP.1": 1,
"ALC_DVS.2": 3
},
"APE": {
"APE_SRE": 1
},
"ASE": {
"ASE_COMP.1": 1
},
"ATE": {
"ATE_COMP.1": 1
},
"AVA": {
"AVA_COMP.1": 1,
"AVA_VAN": 1,
"AVA_VAN.3": 1,
"AVA_VAN.5": 4
}
},
"cc_security_level": {
"EAL": {
"EAL4": 3,
"EAL4 augmented": 1
}
},
"cc_sfr": {
"FAU": {
"FAU_GEN": 1,
"FAU_SAS": 6,
"FAU_SAS.1": 7,
"FAU_SAS.1.1": 2
},
"FCS": {
"FCS_CKM": 4,
"FCS_CKM.1": 2,
"FCS_CKM.1.1": 1,
"FCS_CKM.4": 2,
"FCS_CKM.4.1": 1,
"FCS_COP": 10,
"FCS_COP.1": 1,
"FCS_COP.1.1": 5,
"FCS_RND": 8,
"FCS_RND.1": 6,
"FCS_RND.1.1": 2
},
"FDP": {
"FDP_ACC": 1,
"FDP_ACC.1": 2,
"FDP_ACC.1.1": 1,
"FDP_ACF": 2,
"FDP_ACF.1": 3,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 2,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_UCT": 1,
"FDP_UCT.1": 4,
"FDP_UCT.1.1": 1,
"FDP_UIT": 1,
"FDP_UIT.1": 4,
"FDP_UIT.1.1": 1,
"FDP_UIT.1.2": 1
},
"FIA": {
"FIA_API": 11,
"FIA_API.1": 5,
"FIA_API.1.1": 3,
"FIA_SOS.2": 1,
"FIA_UAU": 5,
"FIA_UAU.1": 2,
"FIA_UAU.1.1": 1,
"FIA_UAU.1.2": 1,
"FIA_UAU.4": 4,
"FIA_UAU.4.1": 1,
"FIA_UAU.5": 4,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UAU.6": 2,
"FIA_UAU.6.1": 1,
"FIA_UID": 2,
"FIA_UID.1": 1,
"FIA_UID.1.1": 1,
"FIA_UID.1.2": 1
},
"FMT": {
"FMT_LIM": 8,
"FMT_LIM.1": 15,
"FMT_LIM.1.1": 3,
"FMT_LIM.2": 14,
"FMT_LIM.2.1": 4,
"FMT_MTD": 17,
"FMT_MTD.1": 2,
"FMT_MTD.1.1": 9,
"FMT_MTD.3": 5,
"FMT_MTD.3.1": 1,
"FMT_SMF": 1,
"FMT_SMF.1": 3,
"FMT_SMF.1.1": 1,
"FMT_SMR": 1,
"FMT_SMR.1": 3,
"FMT_SMR.1.1": 2,
"FMT_SMR.1.2": 1
},
"FPT": {
"FPT_FLS": 1,
"FPT_FLS.1": 3,
"FPT_FLS.1.1": 1,
"FPT_PHP": 1,
"FPT_PHP.3": 4,
"FPT_PHP.3.1": 1,
"FPT_TST": 1,
"FPT_TST.1": 5,
"FPT_TST.1.1": 1,
"FPT_TST.2.1": 1,
"FPT_TST.3.1": 1
}
},
"certification_process": {},
"cipher_mode": {
"CBC": {
"CBC": 1
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {
"KA": {
"Key Agreement": 1
},
"MAC": {
"MAC": 4
}
},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {
"SHA": {
"SHA1": {
"SHA-1": 3
},
"SHA2": {
"SHA-224": 3,
"SHA-256": 3,
"SHA224": 1
}
}
},
"ic_data_group": {
"EF": {
"EF.COM": 10,
"EF.DG1": 14,
"EF.DG13": 1,
"EF.DG14": 9,
"EF.DG15": 5,
"EF.DG16": 14,
"EF.DG2": 7,
"EF.DG3": 18,
"EF.DG4": 16,
"EF.DG5": 6,
"EF.DG6": 1,
"EF.SOD": 11
}
},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RNG": 3
}
},
"side_channel_analysis": {
"FI": {
"Fault injection": 1,
"Malfunction": 4,
"Physical Tampering": 4,
"Physical tampering": 2,
"fault injection": 2,
"malfunction": 4,
"physical tampering": 3
},
"SCA": {
"DPA": 2,
"SPA": 1,
"physical probing": 4,
"side channel": 1,
"timing attacks": 1
},
"other": {
"reverse engineering": 1
}
},
"standard_id": {
"BSI": {
"AIS31": 2
},
"CC": {
"CCMB-2006-09-001": 1,
"CCMB-2007-09-002": 1,
"CCMB-2007-09-003": 1,
"CCMB-2007-09-004": 1
},
"FIPS": {
"FIPS 180-2": 1,
"FIPS 46-3": 1,
"FIPS PUB 46-3": 2
},
"ICAO": {
"ICAO": 13
},
"ISO": {
"ISO/IEC 15946": 2,
"ISO/IEC 7816-2": 1,
"ISO/IEC 7816-4": 1
},
"PKCS": {
"PKCS#3": 3
},
"RFC": {
"RFC 2631": 1,
"RFC3369": 1
}
},
"symmetric_crypto": {
"DES": {
"3DES": {
"TDES": 2,
"Triple-DES": 6
},
"DES": {
"DES": 3
}
},
"constructions": {
"MAC": {
"KMAC": 1
}
}
},
"technical_report_id": {
"BSI": {
"BSI 2006": 1,
"BSI TR-03110": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"st_metadata": {
"/CreationDate": "D:20100427185324+02\u002700\u0027",
"/Keywords": "",
"/ModDate": "D:20100427185324+02\u002700\u0027",
"/Producer": "GPL Ghostscript 8.54",
"pdf_file_size_bytes": 915483,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 85
}
},
"protection_profiles": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.protection_profile.ProtectionProfile",
"pp_eal": null,
"pp_ids": null,
"pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0056b.pdf",
"pp_name": "Machine Readable Travel Document with [ICAO Application] Extended Access Control, Version 1..."
}
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC_2010-17en.pdf",
"scheme": "FR",
"security_level": {
"_type": "Set",
"elements": [
"ALC_DVS.2",
"AVA_VAN.5",
"EAL4+"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC-cible_2010-17en.pdf",
"state": {
"_type": "sec_certs.sample.cc.CCCertificate.InternalState",
"cert": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": false,
"download_ok": false,
"extract_ok": false,
"pdf_hash": null,
"txt_hash": null
},
"report": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "fdd1c6673f30697d17c87b9a496c337afeb378d65e071622328ddcec117c4736",
"txt_hash": "7b73a323c79f33802cb2024c2a26ad8d49af62aa83d2a59d176d64d6af809aa2"
},
"st": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "7d54dbf2d061038151d26c82d464e38839a1f9404ef3565b27730933a91ddbde",
"txt_hash": "7053cf5276de96e55dc776d906b5d8afcf7a61149fba5d5269e3718c6ec4efd4"
}
},
"status": "archived"
}