Protection Profile for electronic Health Card eHC elektronische Gesundheitskarte eGK, Version 2.5

Profile details

Status archived
Valid from 26.03.2008
Valid until 01.11.2012
Scheme πŸ‡©πŸ‡ͺ DE
Category ICs, Smart Cards and Smart Card-Related Devices and Systems
Security level AVA_MSU.3, ADV_IMP.2, EAL4+, AVA_VLA.4

Certification report

Extracted keywords

Security level
EAL 4, EAL 4 augmented
Security Assurance Requirements (SAR)
ADV_IMP.2, AVA_MSU.3, AVA_VLA.4
Protection profiles
BSI-PP-0020-V2-2007-MA-01, BSI-PP-0020-V2-2007, BSI-PP-0020-V2-2007-MA01

Standards
CCIMB-2004-02-009

Protection profile

Extracted keywords

Symmetric Algorithms
HPC
Schemes
MAC
Protocols
SSL

Security level
EAL4, EAL4 augmented
Security Assurance Requirements (SAR)
ADO_DEL, ADO_IGS, ADO_IGS.1, ADV_IMP.2, ADV_SPM.1, ADV_LLD.1, ADV_RCR.1, ADV_FSP.1, ADV_HLD.2, ADV_IMP.1, AGD_ADM.1, AGD_USR.1, ALC_TAT.1, AVA_MSU.3, AVA_VLA, AVA_VLA.4, ASE_PPC.1, ASE_PPC
Security Functional Requirements (SFR)
FCS_RND, FCS_CKM.1, FCS_CKM, FCS_CKM.2, FCS_COP.1, FCS_CKM.4, FCS_RND.1, FCS_CKM.4.1, FCS_COP, FCS_RND.1.1, FDP_ITC.1, FDP_ITC.2, FDP_ACC.2, FDP_ACF.1, FDP_UCT.1, FDP_UCT, FDP_ACC.1, FDP_ACC.2.1, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_RIP.1, FDP_RIP.1.1, FDP_SDI.2, FDP_SDI.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_UIT.1, FDP_UCT.1.1, FDP_IFC.1, FDP_UIT.1.1, FDP_UIT.1.2, FDP_ACF, FDP_ACC, FDP_UIT, FIA_UAU.4, FIA_AFL.1, FIA_AFL, FIA_UAU.1, FIA_ATD.1, FIA_ATD.1.1, FIA_UID.1, FIA_UID.1.1, FIA_UID.1.2, FIA_UAU.1.1, FIA_UAU.1.2, FIA_UAU, FIA_UAU.4.1, FMT_LIM, FMT_MSA.2, FMT_MTD.1, FMT_MSA.3, FMT_SMF.1, FMT_SMR.1, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_MTD, FMT_MSA.1, FPT_FLS.1, FPT_TST.1, FPT_PHP.3, FPT_RVM.1, FPT_SEP.1, FPT_FLS.1.1, FPT_PHP.3.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_AMT.1, FPT_TST, FPT_RVM.1.1, FPT_SEP.1.1, FPT_SEP.1.2, FTP_ITC.1, FTP_TRP.1, FTP_ITC.1.1, FTP_ITC.1.2, FTP_ITC.1.3
Protection profiles
BSI-PP-0020-V2-2007-MA01, BSI-PP-0002, BSI-PP-0005-2002, BSI-PP-0006-2002, BSI-PP-****, BSI-PP-0005-2002T, BSI-PP-0006-2002T, BSI-PP-0002-2001
Evaluation facilities
SRC Security Research & Consulting

Side-channel analysis
physical probing, side channels, DPA, Physical Tampering, physical tampering, Physical tampering, Malfunction, malfunction, fault injection, reverse engineering, Bleichenbacher attack
Certification process
out of scope, - 101 Application note 30: Keys and other data for creation of qualified signatures are out of scope of this protection profile

Standards
ISO/IEC 7816-2, ISO/IEC 7816-4, X.509, CCIMB-2005-08-001, CCIMB-2005-08-002, CCIMB-2005-08-003, CCIMB-2005-08-004
Technical reports
BSI TR-03116

References

No references are available for this protection profile.

Processing updates

Feed
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile was first processed.

Raw data

{
  "_id": "9fcf9db57f6c076d",
  "_type": "sec_certs.sample.protection_profile.ProtectionProfile",
  "dgst": "9fcf9db57f6c076d",
  "heuristics": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.Heuristics"
  },
  "pdf_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.PdfData",
    "pp_filename": "pp0020_v2_ma1b.pdf",
    "pp_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {},
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-PP-****": 1,
          "BSI-PP-0002": 2,
          "BSI-PP-0002-2001": 1,
          "BSI-PP-0005-2002": 2,
          "BSI-PP-0005-2002T": 1,
          "BSI-PP-0006-2002": 3,
          "BSI-PP-0006-2002T": 1,
          "BSI-PP-0020-V2-2007-MA01": 2
        }
      },
      "cc_sar": {
        "ADO": {
          "ADO_DEL": 1,
          "ADO_IGS": 2,
          "ADO_IGS.1": 1
        },
        "ADV": {
          "ADV_FSP.1": 2,
          "ADV_HLD.2": 1,
          "ADV_IMP.1": 1,
          "ADV_IMP.2": 6,
          "ADV_LLD.1": 2,
          "ADV_RCR.1": 1,
          "ADV_SPM.1": 2
        },
        "AGD": {
          "AGD_ADM.1": 2,
          "AGD_USR.1": 2
        },
        "ALC": {
          "ALC_TAT.1": 1
        },
        "ASE": {
          "ASE_PPC": 1,
          "ASE_PPC.1": 3
        },
        "AVA": {
          "AVA_MSU.3": 5,
          "AVA_VLA": 1,
          "AVA_VLA.4": 4
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL4": 12,
          "EAL4 augmented": 2
        }
      },
      "cc_sfr": {
        "FCS": {
          "FCS_CKM": 8,
          "FCS_CKM.1": 21,
          "FCS_CKM.2": 2,
          "FCS_CKM.4": 25,
          "FCS_CKM.4.1": 1,
          "FCS_COP": 44,
          "FCS_COP.1": 13,
          "FCS_RND": 5,
          "FCS_RND.1": 13,
          "FCS_RND.1.1": 2
        },
        "FDP": {
          "FDP_ACC": 1,
          "FDP_ACC.1": 7,
          "FDP_ACC.2": 12,
          "FDP_ACC.2.1": 2,
          "FDP_ACF": 3,
          "FDP_ACF.1": 12,
          "FDP_ACF.1.1": 1,
          "FDP_ACF.1.2": 1,
          "FDP_ACF.1.3": 1,
          "FDP_ACF.1.4": 1,
          "FDP_IFC.1": 4,
          "FDP_ITC.1": 16,
          "FDP_ITC.2": 16,
          "FDP_RIP.1": 7,
          "FDP_RIP.1.1": 1,
          "FDP_SDI.1": 2,
          "FDP_SDI.2": 5,
          "FDP_SDI.2.1": 1,
          "FDP_SDI.2.2": 1,
          "FDP_UCT": 2,
          "FDP_UCT.1": 10,
          "FDP_UCT.1.1": 1,
          "FDP_UIT": 1,
          "FDP_UIT.1": 7,
          "FDP_UIT.1.1": 1,
          "FDP_UIT.1.2": 1
        },
        "FIA": {
          "FIA_AFL": 12,
          "FIA_AFL.1": 5,
          "FIA_ATD.1": 7,
          "FIA_ATD.1.1": 1,
          "FIA_UAU": 1,
          "FIA_UAU.1": 10,
          "FIA_UAU.1.1": 1,
          "FIA_UAU.1.2": 1,
          "FIA_UAU.4": 7,
          "FIA_UAU.4.1": 1,
          "FIA_UID.1": 8,
          "FIA_UID.1.1": 1,
          "FIA_UID.1.2": 1
        },
        "FMT": {
          "FMT_LIM": 5,
          "FMT_LIM.1": 19,
          "FMT_LIM.1.1": 2,
          "FMT_LIM.2": 18,
          "FMT_LIM.2.1": 1,
          "FMT_MSA.1": 1,
          "FMT_MSA.2": 19,
          "FMT_MSA.3": 2,
          "FMT_MTD": 22,
          "FMT_MTD.1": 9,
          "FMT_SMF.1": 18,
          "FMT_SMF.1.1": 1,
          "FMT_SMR.1": 18,
          "FMT_SMR.1.1": 1,
          "FMT_SMR.1.2": 1
        },
        "FPT": {
          "FPT_AMT.1": 5,
          "FPT_FLS.1": 10,
          "FPT_FLS.1.1": 1,
          "FPT_PHP.3": 9,
          "FPT_PHP.3.1": 1,
          "FPT_RVM.1": 9,
          "FPT_RVM.1.1": 1,
          "FPT_SEP.1": 9,
          "FPT_SEP.1.1": 1,
          "FPT_SEP.1.2": 1,
          "FPT_TST": 1,
          "FPT_TST.1": 10,
          "FPT_TST.1.1": 1,
          "FPT_TST.1.2": 1,
          "FPT_TST.1.3": 1
        },
        "FTP": {
          "FTP_ITC.1": 14,
          "FTP_ITC.1.1": 1,
          "FTP_ITC.1.2": 1,
          "FTP_ITC.1.3": 1,
          "FTP_TRP.1": 4
        }
      },
      "certification_process": {
        "OutOfScope": {
          "- 101 Application note 30: Keys and other data for creation of qualified signatures are out of scope of this protection profile": 1,
          "out of scope": 1
        }
      },
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {
        "TLS": {
          "SSL": {
            "SSL": 1
          }
        }
      },
      "crypto_scheme": {
        "MAC": {
          "MAC": 13
        }
      },
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {
        "SRC": {
          "SRC Security Research \u0026 Consulting": 1
        }
      },
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {
        "FI": {
          "Malfunction": 4,
          "Physical Tampering": 3,
          "Physical tampering": 1,
          "fault injection": 1,
          "malfunction": 4,
          "physical tampering": 4
        },
        "SCA": {
          "DPA": 1,
          "physical probing": 4,
          "side channels": 2
        },
        "other": {
          "Bleichenbacher attack": 1,
          "reverse engineering": 1
        }
      },
      "standard_id": {
        "CC": {
          "CCIMB-2005-08-001": 2,
          "CCIMB-2005-08-002": 2,
          "CCIMB-2005-08-003": 2,
          "CCIMB-2005-08-004": 1
        },
        "ISO": {
          "ISO/IEC 7816-2": 1,
          "ISO/IEC 7816-4": 1
        },
        "X509": {
          "X.509": 7
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "HPC": {
            "HPC": 31
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI TR-03116": 2
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "pp_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
      "/CreationDate": "D:20080403081514+02\u002700\u0027",
      "/Creator": "Writer",
      "/Keywords": "electronic Health Card, eHC, BSI, BSI-PP-0020-V2-2007-MA01",
      "/ModDate": "D:20080403125401+02\u002700\u0027",
      "/Producer": "StarOffice 8",
      "/Subject": "Common Criteria Protection Profile",
      "/Title": "electronic Health Card (eHC)",
      "pdf_file_size_bytes": 1032259,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": [
          "http://www.gematik.de/",
          "http://www.dimdi.de/de/ehealth/karte/bit4health",
          "http://www.bundesnetzagentur.de/"
        ]
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 82
    },
    "report_filename": "pp0020_v2_ma1a.pdf",
    "report_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {},
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-PP-0020-V2-2007": 4,
          "BSI-PP-0020-V2-2007-MA-01": 3,
          "BSI-PP-0020-V2-2007-MA01": 1
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_IMP.2": 1
        },
        "AVA": {
          "AVA_MSU.3": 1,
          "AVA_VLA.4": 1
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 4": 1,
          "EAL 4 augmented": 1
        }
      },
      "cc_sfr": {},
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {},
      "standard_id": {
        "CC": {
          "CCIMB-2004-02-009": 1
        }
      },
      "symmetric_crypto": {},
      "technical_report_id": {},
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "report_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
      "/Category": "Protection Profile electronic Health Card (eHC)\u2013 elektronische Gesundheitskarte (eGK), Version 2.5, Gesundheitskarte, BSI-PP-0020-V2-2007-MA-01",
      "/Company": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik, Godesberger Allee 185-189, 53175 Bonn ",
      "/CreationDate": "D:20080327145802+01\u002700\u0027",
      "/Creator": "Acrobat PDFMaker 8.1 f\u00fcr Word",
      "/Keywords": "Protection Profile, electronic Health Card, eHC, eGK, elektronische Gesundheitskarte",
      "/ModDate": "D:20080327150123+01\u002700\u0027",
      "/Producer": "Acrobat Distiller 8.1.0 (Windows)",
      "/SourceModified": "D:20080327135754",
      "/Title": "Assurance Continuity Maintenance Report zum Protection Profile electronic Health Card (eHC)\u2013 elektronische Gesundheitskarte (eGK), Version 2.5 ",
      "pdf_file_size_bytes": 41744,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 3
    }
  },
  "scheme_metadata": null,
  "state": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.InternalState",
    "pp": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": "9418569de12980ccff0d87278a70e1d7737e3801842bfae0ae50a0c0e47a1276",
      "source_hash": "38d12be643cfef1c65584bec7f7236987feb2b086b075765d03c70ce2bbb4598",
      "txt_hash": "d4e97e78c38edf4294355cf8f4cc58d06b6267bc2844356b9e4105eb123decb2"
    },
    "report": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": "e62364b47bf0f37f45c3e9b021788d9fbe8a4de5ce7f6856a167492666afaa74",
      "source_hash": "3f90510190687bfba76270ffd954f63f1bb6bf9927a73022e17753ef246b5d17",
      "txt_hash": "44e55b65acd9fdb78e7ad206532d1fdf97ccc248641f132c5dc64d0e1c25f169"
    }
  },
  "web_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.WebData",
    "category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
    "is_collaborative": false,
    "maintenances": [],
    "name": "Protection Profile for electronic Health Card eHC elektronische Gesundheitskarte eGK, Version 2.5",
    "not_valid_after": "2012-11-01",
    "not_valid_before": "2008-03-26",
    "pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0020_v2_ma1b.pdf",
    "report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0020_v2_ma1a.pdf",
    "scheme": "DE",
    "security_level": {
      "_type": "Set",
      "elements": [
        "AVA_MSU.3",
        "EAL4+",
        "ADV_IMP.2",
        "AVA_VLA.4"
      ]
    },
    "status": "archived",
    "version": "2.5"
  }
}