This page was not yet optimized for use on mobile devices.
Machine Readable Travel Document with [ICAO Application], Extended Access Control, Version 1.2
Web information ?
Status: archivedCertification date: 2008-01-30
Archived date: 2013-01-29
Scheme: 🇩🇪
Category: ICs, Smart Cards and Smart Card-Related Devices and Systems
Security level: ALC_DVS.2, AVA_MSU.3, ADV_IMP.2, AVA_VLA.4, EAL4+
Certification report ?
Extracted keywords
Security level
EAL4Protection profiles
BSI-PP-0026-2006-MA-01, BSI-PP-0026-2006Certification process
Analysis Report (Appendix to the Application for the Maintenanceprocess, dated 19th November 2007, confidential document) [3] Certification Report BSI-PP-0026-2006 for Protection Profile for Machine Readable TravelStandards
CCIMB-2004-02-009File metadata
Title | Assurance Continuity Maintenance Report |
---|---|
Keywords | Machine Readable Travel Document with "ICAO Application", Ectendes Access Control, version 1.2, BMI, PP, Schutzprofile |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20080130131807+01'00' |
Modification date | D:20080130140756+01'00' |
Pages | 2 |
Creator | Acrobat PDFMaker 8.1 für Word |
Producer | Acrobat Distiller 8.1.0 (Windows) |
Profile ?
Extracted keywords
Symmetric Algorithms
DES, Triple-DES, KMACAsymmetric Algorithms
ECDH, ECDSA, Diffie-Hellman, DHHash functions
SHA-1, SHA-224, SHA-256, SHA-384, SHA-512Schemes
MAC, Key AgreementRandomness
RNDBlock cipher modes
ECB, CBCIC data groups
EF.DG1, EF.DG2, EF.DG3, EF.DG4, EF.DG5, EF.DG16, EF.DG13, EF.DG14, EF.DG15, EF.COM, EF.SODSecurity level
EAL4, EAL4 augmentedSecurity Assurance Requirements (SAR)
ADO_DEL, ADO_IGS, ADO_IGS.1, ADV_IMP.2, ADV_SPM.1, ADV_LLD.1, ADV_RCR.1, ADV_FSP.1, ADV_HLD.2, ADV_IMP.1, AGD_ADM.1, AGD_USR.1, ALC_DVS.2, ALC_TAT.1, AVA_MSU.3, AVA_VLA.4, AVA_VLA.2, APE_SRESecurity Functional Requirements (SFR)
FAU_SAS, FAU_GEN, FAU_SAS.1, FAU_SAS.1.1, FCS_RND, FCS_CKM.1, FCS_RND.1, FCS_RND.1.1, FCS_CKM, FCS_CKM.2, FCS_COP.1, FCS_CKM.4, FCS_COP, FDP_ACF, FDP_ITC.1, FDP_ITC.2, FDP_ACC.1, FDP_ACC.1.1, FDP_ACF.1, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_UCT.1, FDP_UCT, FDP_IFC.1, FDP_UIT, FDP_UIT.1, FDP_DAU.1, FDP_DAU, FIA_API, FIA_SOS.2, FIA_API.1, FIA_API.1.1, FIA_UAU, FIA_AFL.1, FIA_UID.1, FIA_UID.1.1, FIA_UID.1.2, FIA_UAU.1, FIA_UAU.1.1, FIA_UAU.1.2, FIA_UAU.4, FIA_UAU.5, FIA_UAU.6, FIA_AFL.1.1, FIA_AFL.1.2, FIA_UAU.5.2, FMT_LIM, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_MTD, FMT_MSA.2, FMT_MSA.3, FMT_MTD.3, FMT_SMF.1, FMT_SMR.1, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_MTD.1, FMT_MTD.3.1, FMT_MDT.3, FMT_MSA.1, FPR_TST.1.1, FPT_FLS.1, FPT_TST.1, FPT_PHP.3, FPT_RVM.1, FPT_SEP.1, FPT_FLS.1.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_AMT.1, FPT_PHP.3.1, FPT_RVM.1.1, FPT_SEP.1.1, FPT_SEP.1.2, FTP_ITC.1, FTP_TRP.1Protection profiles
BSI-PP-0026, BSI-CC-PP-0026, BSI-PP-0017, BSI-PP-0002-2001Side-channel analysis
physical probing, DPA, SPA, timing attacks, Physical Tampering, physical tampering, Physical tampering, Malfunction, malfunction, fault injection, reverse engineeringStandards
FIPS 180-2, FIPS 46-3, PKCS#3, RFC 2631, RFC3369, ISO/IEC 7816-2, ISO/IEC 14443, ISO/IEC 7816-4, ISO/IEC 9796-2, ISO/IEC 15946-1, ISO/IEC 15946-2, ICAO, CCMB-2005-08-001, CCMB-2005-08-002, CCMB-2005-08-003, CCMB-2005-08-004Technical reports
BSI TR-03110, BSI 2006File metadata
Title | Common Criteria Protection Profile BSI-PP-0026 |
---|---|
Subject | Machine Readable Travel Document with "ICAO Application", Extended Access Control |
Keywords | BSI-CC-PP-0026, Machine Readable Travel Document with "ICAO Application", Extended Access Control, |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20080201090327+01'00' |
Modification date | D:20080201103455+01'00' |
Pages | 96 |
Creator | Acrobat PDFMaker 7.0.7 für Word |
Producer | Acrobat Distiller 7.0.5 (Windows) |
References ?
- ACTIA L2000 Digital Tachograph – SMARTACH Famille Standard (références 921435 Indice B, 921439 Indice B et 921463 Indice B) archived
- PEACOS Electronic Passport with EAC on P5CD080 V0B, version 1.2 archived
- STARCOS 3.3 ID EAC+AA C1 archived
- Sagem Securite CC IDeal Citiz SmartCard (on SB23YR48B), version 1.4.5 ICAO EAC application archived
- eTravel EAC v1.2 masquée sur le composant S3CC9LC archived
Updates ?
-
04.02.2025 The protection profile was first processed.
New Protection Profile
A new Protection Profile with the name Machine Readable Travel Document with [ICAO Application], Extended Access Control, Version 1.2 was processed.
Raw data
{
"_id": "627a214702fd03e7",
"_type": "sec_certs.sample.protection_profile.ProtectionProfile",
"dgst": "627a214702fd03e7",
"heuristics": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.Heuristics"
},
"pdf_data": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.PdfData",
"pp_filename": "pp0026_ma1b.pdf",
"pp_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECDH": {
"ECDH": 3
},
"ECDSA": {
"ECDSA": 2
}
},
"FF": {
"DH": {
"DH": 3,
"Diffie-Hellman": 6
}
}
},
"cc_cert_id": {},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0026": 1,
"BSI-PP-0002-2001": 1,
"BSI-PP-0017": 2,
"BSI-PP-0026": 1
}
},
"cc_sar": {
"ADO": {
"ADO_DEL": 2,
"ADO_IGS": 1,
"ADO_IGS.1": 1
},
"ADV": {
"ADV_FSP.1": 2,
"ADV_HLD.2": 1,
"ADV_IMP.1": 1,
"ADV_IMP.2": 4,
"ADV_LLD.1": 2,
"ADV_RCR.1": 1,
"ADV_SPM.1": 5
},
"AGD": {
"AGD_ADM.1": 2,
"AGD_USR.1": 2
},
"ALC": {
"ALC_DVS.2": 4,
"ALC_TAT.1": 1
},
"APE": {
"APE_SRE": 1
},
"AVA": {
"AVA_MSU.3": 4,
"AVA_VLA.2": 2,
"AVA_VLA.4": 4
}
},
"cc_security_level": {
"EAL": {
"EAL4": 11,
"EAL4 augmented": 2
}
},
"cc_sfr": {
"FAU": {
"FAU_GEN": 1,
"FAU_SAS": 6,
"FAU_SAS.1": 10,
"FAU_SAS.1.1": 2
},
"FCS": {
"FCS_CKM": 56,
"FCS_CKM.1": 47,
"FCS_CKM.2": 10,
"FCS_CKM.4": 53,
"FCS_COP": 106,
"FCS_COP.1": 26,
"FCS_RND": 23,
"FCS_RND.1": 12,
"FCS_RND.1.1": 1
},
"FDP": {
"FDP_ACC.1": 21,
"FDP_ACC.1.1": 1,
"FDP_ACF": 1,
"FDP_ACF.1": 11,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 2,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 2,
"FDP_DAU": 7,
"FDP_DAU.1": 4,
"FDP_IFC.1": 8,
"FDP_ITC.1": 27,
"FDP_ITC.2": 28,
"FDP_UCT": 14,
"FDP_UCT.1": 5,
"FDP_UIT": 14,
"FDP_UIT.1": 5
},
"FIA": {
"FIA_AFL.1": 5,
"FIA_AFL.1.1": 3,
"FIA_AFL.1.2": 3,
"FIA_API": 25,
"FIA_API.1": 8,
"FIA_API.1.1": 1,
"FIA_SOS.2": 1,
"FIA_UAU": 65,
"FIA_UAU.1": 10,
"FIA_UAU.1.1": 1,
"FIA_UAU.1.2": 1,
"FIA_UAU.4": 9,
"FIA_UAU.5": 7,
"FIA_UAU.5.2": 1,
"FIA_UAU.6": 6,
"FIA_UID.1": 12,
"FIA_UID.1.1": 1,
"FIA_UID.1.2": 1
},
"FMT": {
"FMT_LIM": 7,
"FMT_LIM.1": 18,
"FMT_LIM.1.1": 2,
"FMT_LIM.2": 17,
"FMT_LIM.2.1": 2,
"FMT_MDT.3": 1,
"FMT_MSA.1": 1,
"FMT_MSA.2": 37,
"FMT_MSA.3": 2,
"FMT_MTD": 49,
"FMT_MTD.1": 14,
"FMT_MTD.3": 7,
"FMT_MTD.3.1": 1,
"FMT_SMF.1": 23,
"FMT_SMF.1.1": 1,
"FMT_SMR.1": 23,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPR": {
"FPR_TST.1.1": 1
},
"FPT": {
"FPT_AMT.1": 1,
"FPT_FLS.1": 10,
"FPT_FLS.1.1": 1,
"FPT_PHP.3": 8,
"FPT_PHP.3.1": 1,
"FPT_RVM.1": 6,
"FPT_RVM.1.1": 1,
"FPT_SEP.1": 7,
"FPT_SEP.1.1": 1,
"FPT_SEP.1.2": 1,
"FPT_TST.1": 9,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 2
},
"FTP": {
"FTP_ITC.1": 9,
"FTP_TRP.1": 8
}
},
"certification_process": {},
"cipher_mode": {
"CBC": {
"CBC": 3
},
"ECB": {
"ECB": 1
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {
"KA": {
"Key Agreement": 1
},
"MAC": {
"MAC": 9
}
},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {
"SHA": {
"SHA1": {
"SHA-1": 8
},
"SHA2": {
"SHA-224": 3,
"SHA-256": 3,
"SHA-384": 1,
"SHA-512": 1
}
}
},
"ic_data_group": {
"EF": {
"EF.COM": 8,
"EF.DG1": 26,
"EF.DG13": 3,
"EF.DG14": 10,
"EF.DG15": 1,
"EF.DG16": 26,
"EF.DG2": 9,
"EF.DG3": 13,
"EF.DG4": 12,
"EF.DG5": 6,
"EF.SOD": 8
}
},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RND": 3
}
},
"side_channel_analysis": {
"FI": {
"Malfunction": 3,
"Physical Tampering": 5,
"Physical tampering": 1,
"fault injection": 1,
"malfunction": 6,
"physical tampering": 2
},
"SCA": {
"DPA": 2,
"SPA": 1,
"physical probing": 4,
"timing attacks": 1
},
"other": {
"reverse engineering": 1
}
},
"standard_id": {
"CC": {
"CCMB-2005-08-001": 2,
"CCMB-2005-08-002": 2,
"CCMB-2005-08-003": 2,
"CCMB-2005-08-004": 1
},
"FIPS": {
"FIPS 180-2": 4,
"FIPS 46-3": 3
},
"ICAO": {
"ICAO": 23
},
"ISO": {
"ISO/IEC 14443": 2,
"ISO/IEC 15946-1": 1,
"ISO/IEC 15946-2": 1,
"ISO/IEC 7816-2": 1,
"ISO/IEC 7816-4": 1,
"ISO/IEC 9796-2": 1
},
"PKCS": {
"PKCS#3": 2
},
"RFC": {
"RFC 2631": 1,
"RFC3369": 1
}
},
"symmetric_crypto": {
"DES": {
"3DES": {
"Triple-DES": 20
},
"DES": {
"DES": 5
}
},
"constructions": {
"MAC": {
"KMAC": 1
}
}
},
"technical_report_id": {
"BSI": {
"BSI 2006": 1,
"BSI TR-03110": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"pp_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/Company": "BSI, Godesberger Allee 185-189, 53175 Bonn",
"/CreationDate": "D:20080201090327+01\u002700\u0027",
"/Creator": "Acrobat PDFMaker 7.0.7 f\u00fcr Word",
"/Keywords": "BSI-CC-PP-0026, Machine Readable Travel Document with \"ICAO Application\", Extended Access Control, ",
"/ModDate": "D:20080201103455+01\u002700\u0027",
"/Producer": "Acrobat Distiller 7.0.5 (Windows)",
"/SourceModified": "D:20080201075032",
"/Subject": "Machine Readable Travel Document with \"ICAO Application\", Extended Access Control",
"/Title": "Common Criteria Protection Profile BSI-PP-0026",
"pdf_file_size_bytes": 781970,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 96
},
"report_filename": "pp0026_ma1a.pdf",
"report_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-PP-0026-2006": 6,
"BSI-PP-0026-2006-MA-01": 1
}
},
"cc_sar": {},
"cc_security_level": {
"EAL": {
"EAL4": 1
}
},
"cc_sfr": {},
"certification_process": {
"ConfidentialDocument": {
"Analysis Report (Appendix to the Application for the Maintenanceprocess, dated 19th November 2007, confidential document) [3] Certification Report BSI-PP-0026-2006 for Protection Profile for Machine Readable Travel": 1
}
},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"CC": {
"CCIMB-2004-02-009": 1
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/Company": "BSI, Godesberger Allee 185-189, 53175 Bonn",
"/CreationDate": "D:20080130131807+01\u002700\u0027",
"/Creator": "Acrobat PDFMaker 8.1 f\u00fcr Word",
"/Keywords": "Machine Readable Travel Document with \"ICAO Application\", Ectendes Access Control, version 1.2, BMI, PP, Schutzprofile",
"/ModDate": "D:20080130140756+01\u002700\u0027",
"/Producer": "Acrobat Distiller 8.1.0 (Windows)",
"/SourceModified": "D:20080130121600",
"/Title": "Assurance Continuity Maintenance Report",
"pdf_file_size_bytes": 44503,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 2
}
},
"state": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.InternalState",
"pp": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "7d57e498adf71a91730ac852a4c276c49848068f536ffa4b693b6d20d66679ce",
"txt_hash": "0bb54538e0970408b6cc29bed9e6b81a94fc9a621b096f3c6b2be0b0f0128bdb"
},
"report": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "9301d10fc1c42022ce20aaba1ec0b7541283190406b37556dd6bc6d02710ae1b",
"txt_hash": "ca58eb41f0746c7dabf5b587035cc7edc56ef8a8b0f3cfb268c39579383d4ac3"
}
},
"web_data": {
"_type": "sec_certs.sample.protection_profile.ProtectionProfile.WebData",
"category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
"is_collaborative": false,
"maintenances": [],
"name": "Machine Readable Travel Document with [ICAO Application], Extended Access Control, Version 1.2",
"not_valid_after": "2013-01-29",
"not_valid_before": "2008-01-30",
"pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0026_ma1b.pdf",
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0026_ma1a.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"AVA_VLA.4",
"EAL4+",
"ALC_DVS.2",
"AVA_MSU.3",
"ADV_IMP.2"
]
},
"status": "archived",
"version": "1.2"
}
}