Intrusion Detection System System Protection Profile, Version 1.6

Profile details

Status archived
Valid from 04.04.2006
Valid until 21.03.2008
Scheme πŸ‡ΊπŸ‡Έ US
Category Detection Devices and Systems
Security level EAL2

Certification report

certification report file processing did not finish successfully.
Download pdf: OK
Convert pdf to text: ERROR
Extract keywords: ERROR

Protection profile

Extracted keywords

Security level
EAL 2, EAL2
Claims
O.PROTCT, O.IDSCAN, O.IDSENS, O.IDANLZ, O.RESPON, O.EADMIN, O.ACCESS, O.IDAUTH, O.OFLOWS, O.AUDITS, O.INTEGR, O.EXPORT, O.INSTAL, O.CREDEN, O.PERSON, O.INTROP, O.PHYCAL, T.COMINT, T.COMDIS, T.LOSSOF, T.NOHALT, T.PRIVIL, T.IMPCON, T.INFLUX, T.FACCNT, T.SCNCFG, T.SCNMLC, T.SCNVUL, T.FALACT, T.FALREC, T.FALASC, T.MISUSE, T.INADVE, T.MISACT, A.ACCESS, A.DYNMIC, A.ASCOPE, A.PROTCT, A.LOCATE, A.MANAGE, A.NOEVIL, A.NOTRST, A.NOTRUST, OE.TIME, OE.PROTECT, OE.AUDIT_PROTECTION, OE.AUDIT_SORT
Security Assurance Requirements (SAR)
ACM_CAP.2, ADO_DEL.1, ADO_IGS.1, ADV_FSP.1, ADV_HLD.1, ADV_RCR.1, AGD_ADM.1, AGD_USR.1, ATE_COV.1, ATE_FUN.1, ATE_IND.2, AVA_SOF.1, AVA_VLA.1
Security Functional Requirements (SFR)
FAU_GEN.1, FAU_SAR.1, FAU_SAR.2, FAU_SAR.3, FAU_SEL.1, FAU_STG.2, FAU_STG.4, FAU_GEN.1.1, FAU_GEN.1.2, FAU_SAR.1.1, FAU_SAR.1.2, FAU_SAR.2.1, FAU_SAR.3.1, FAU_SEL.1.1, FAU_STG.2.1, FAU_STG.2.2, FAU_STG.2.3, FAU_STG.4.1, FAU_SAR, FIA_UAU.1, FIA_ATD.1, FIA_UID.1, FIA_UAU, FIA_UAU.1.1, FIA_UAU.1.2, FIA_AFL.1, FIA_AFL.1.1, FIA_AFL.1.2, FIA_ATD.1.1, FIA_UID.1.1, FIA_UID.1.2, FMT_MOF.1, FMT_MTD.1, FMT_SMR.1, FMT_MDT.1, FMT_MOF.1.1, FMT_MTD.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FPT_ITA.1, FPT_ITC.1, FPT_ITI.1, FPT_RVM.1, FPT_SEP.1, FPT_STM.1, FPT_ITA.1.1, FPT_ITC.1.1, FPT_ITI.1.1, FPT_ITI.1.2, FPT_RVM.1.1, FPT_SEP.1.1, FPT_STM.1.1

Side-channel analysis
malfunction

Standards
ISO/IEC 15408:1999

References

Automated inference - use with caution

All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.

Processing updates

Feed
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile data changed.
  • The protection profile was first processed.

Raw data

{
  "_id": "3af2791847aec55b",
  "_type": "sec_certs.sample.protection_profile.ProtectionProfile",
  "dgst": "3af2791847aec55b",
  "heuristics": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.Heuristics"
  },
  "pdf_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.PdfData",
    "pp_filename": "pp_ids_sys_v1.6.pdf",
    "pp_keywords": {
      "asymmetric_crypto": {},
      "cc_cert_id": {},
      "cc_claims": {
        "A": {
          "A.ACCESS": 3,
          "A.ASCOPE": 3,
          "A.DYNMIC": 3,
          "A.LOCATE": 3,
          "A.MANAGE": 3,
          "A.NOEVIL": 3,
          "A.NOTRST": 2,
          "A.NOTRUST": 1,
          "A.PROTCT": 3
        },
        "O": {
          "O.ACCESS": 10,
          "O.AUDITS": 12,
          "O.CREDEN": 4,
          "O.EADMIN": 8,
          "O.EXPORT": 7,
          "O.IDANLZ": 9,
          "O.IDAUTH": 23,
          "O.IDSCAN": 7,
          "O.IDSENS": 7,
          "O.INSTAL": 4,
          "O.INTEGR": 5,
          "O.INTROP": 4,
          "O.OFLOWS": 4,
          "O.PERSON": 7,
          "O.PHYCAL": 7,
          "O.PROTCT": 12,
          "O.RESPON": 3
        },
        "OE": {
          "OE.AUDIT_PROTECTION": 1,
          "OE.AUDIT_SORT": 1,
          "OE.PROTECT": 2,
          "OE.TIME": 1
        },
        "T": {
          "T.COMDIS": 4,
          "T.COMINT": 4,
          "T.FACCNT": 3,
          "T.FALACT": 3,
          "T.FALASC": 3,
          "T.FALREC": 3,
          "T.IMPCON": 3,
          "T.INADVE": 3,
          "T.INFLUX": 3,
          "T.LOSSOF": 3,
          "T.MISACT": 3,
          "T.MISUSE": 3,
          "T.NOHALT": 3,
          "T.PRIVIL": 3,
          "T.SCNCFG": 3,
          "T.SCNMLC": 3,
          "T.SCNVUL": 3
        }
      },
      "cc_protection_profile_id": {},
      "cc_sar": {
        "ACM": {
          "ACM_CAP.2": 13
        },
        "ADO": {
          "ADO_DEL.1": 7,
          "ADO_IGS.1": 7
        },
        "ADV": {
          "ADV_FSP.1": 10,
          "ADV_HLD.1": 13,
          "ADV_RCR.1": 6
        },
        "AGD": {
          "AGD_ADM.1": 13,
          "AGD_USR.1": 11
        },
        "ATE": {
          "ATE_COV.1": 6,
          "ATE_FUN.1": 11,
          "ATE_IND.2": 9
        },
        "AVA": {
          "AVA_SOF.1": 8,
          "AVA_VLA.1": 8
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 2": 1,
          "EAL2": 3
        }
      },
      "cc_sfr": {
        "FAU": {
          "FAU_GEN.1": 9,
          "FAU_GEN.1.1": 2,
          "FAU_GEN.1.2": 2,
          "FAU_SAR": 1,
          "FAU_SAR.1": 5,
          "FAU_SAR.1.1": 2,
          "FAU_SAR.1.2": 2,
          "FAU_SAR.2": 7,
          "FAU_SAR.2.1": 2,
          "FAU_SAR.3": 6,
          "FAU_SAR.3.1": 2,
          "FAU_SEL.1": 6,
          "FAU_SEL.1.1": 2,
          "FAU_STG.2": 10,
          "FAU_STG.2.1": 2,
          "FAU_STG.2.2": 1,
          "FAU_STG.2.3": 1,
          "FAU_STG.4": 6,
          "FAU_STG.4.1": 2
        },
        "FIA": {
          "FIA_AFL.1": 1,
          "FIA_AFL.1.1": 2,
          "FIA_AFL.1.2": 1,
          "FIA_ATD.1": 4,
          "FIA_ATD.1.1": 2,
          "FIA_UAU": 1,
          "FIA_UAU.1": 6,
          "FIA_UAU.1.1": 2,
          "FIA_UAU.1.2": 2,
          "FIA_UID.1": 7,
          "FIA_UID.1.1": 2,
          "FIA_UID.1.2": 2
        },
        "FMT": {
          "FMT_MDT.1": 1,
          "FMT_MOF.1": 8,
          "FMT_MOF.1.1": 2,
          "FMT_MTD.1": 9,
          "FMT_MTD.1.1": 2,
          "FMT_SMR.1": 6,
          "FMT_SMR.1.1": 2,
          "FMT_SMR.1.2": 1
        },
        "FPT": {
          "FPT_ITA.1": 4,
          "FPT_ITA.1.1": 2,
          "FPT_ITC.1": 5,
          "FPT_ITC.1.1": 2,
          "FPT_ITI.1": 5,
          "FPT_ITI.1.1": 2,
          "FPT_ITI.1.2": 1,
          "FPT_RVM.1": 9,
          "FPT_RVM.1.1": 2,
          "FPT_SEP.1": 10,
          "FPT_SEP.1.1": 3,
          "FPT_STM.1": 6,
          "FPT_STM.1.1": 2
        }
      },
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {},
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {
        "FI": {
          "malfunction": 2
        }
      },
      "standard_id": {
        "ISO": {
          "ISO/IEC 15408:1999": 1
        }
      },
      "symmetric_crypto": {},
      "technical_report_id": {},
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "pp_metadata": {
      "/Author": "Glen Lee",
      "/Company": "CIST-EAST",
      "/CreationDate": "D:20060911152225-04\u002700\u0027",
      "/Creator": "Acrobat PDFMaker 7.0 for Word",
      "/ModDate": "D:20060911152246-04\u002700\u0027",
      "/Producer": "Acrobat Distiller 7.0 (Windows)",
      "/SourceModified": "D:20060502132440",
      "/Title": "1 PROTECTION PROFILE (PP) INTRODUCTION",
      "pdf_file_size_bytes": 349947,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 59
    },
    "report_filename": "",
    "report_keywords": null,
    "report_metadata": null
  },
  "scheme_metadata": {
    "cc_version": "2.x",
    "pp_short_name": "PP_IDS_SYS_V1.6",
    "pp_sponsor_id": "NSA",
    "pp_transition": null,
    "predecessor": "PP_IDS_SYS_V1.5",
    "source_scheme": "US",
    "successor": "PP_IDS_SYS_BR_V1.7"
  },
  "state": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.InternalState",
    "pp": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": "3c41cf785d06255f8dfa51ccd5b8815702afc455fdc63f95aff0ad56ef371430",
      "txt_hash": "34dacd30df28eeae468748afa0dbc115625145523bf81764455ec6e74a20626e"
    },
    "report": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": false,
      "download_ok": true,
      "extract_ok": false,
      "json_hash": null,
      "source_hash": "6adef86c67e4bbbcbc8872bedf10c93c33839884a5cb1ca1d36f080444041ca7",
      "txt_hash": null
    }
  },
  "web_data": {
    "_type": "sec_certs.sample.protection_profile.ProtectionProfile.WebData",
    "category": "Detection Devices and Systems",
    "is_collaborative": false,
    "maintenances": [],
    "name": "Intrusion Detection System System Protection Profile, Version 1.6",
    "not_valid_after": "2008-03-21",
    "not_valid_before": "2006-04-04",
    "pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp_ids_sys_v1.6.pdf",
    "report_link": "https://www.commoncriteriaportal.org#no_cert",
    "scheme": "US",
    "security_level": {
      "_type": "Set",
      "elements": [
        "EAL2"
      ]
    },
    "status": "archived",
    "version": "1.6"
  }
}