Compliant Meter Postal Security Device

Certificate details

Certificate ID #261
Status historical
Historical reason Skipjack is no longer approved
Validation dates 11.10.2002 , 21.10.2002 , 20.02.2003 , 07.03.2003
Standard FIPS 140-1
Security level 3
Type Hardware
Embodiment Multi-Chip Stand Alone
Caveat None
Exceptions
  • Physical Security: Level 3 +EFP
Description The Pitney Bowes Compliant Meter Postal Security Device (PSD) has been designed in compliance with the United States Postal Service (USPS), Information-Based Indicia Program (IBIP). It employs strong encryption, decryption, and digital signature techniques for the protection of customer funds in Pitney Bowes IBIP Metering products. The PSD has been designed to support international postal markets and their rapidly evolving requirements for digital indicia.
Version (Hardware) Part number 1A00, Revisions AAA, AAB, AAC, AAD, and AAE.
Vendor Pitney Bowes, Inc. http://www.pb.com
Lab UL Verification Services, Inc.
References

This certificate's webpage directly references 0 certificates, transitively this expands into 0 certificates.

Security policy

Extracted keywords

Symmetric Algorithms
DEA, DES, TDEA, TDES, 3DES, Skipjack
Asymmetric Algorithms
DSA
Hash functions
SHA-1
Schemes
MAC, Key Exchange

Security level
Level 3

Cross-references

Incoming
  • 476 - historical - Incognito TSM410
  • 1931 - historical - SafeZone FIPS Cryptographic Module

Automated analysis

Automated inference - use with caution

All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. This applies equally to the Cross-references section below. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.

No automatically derived data are available in this section.

Cross-references

Loading...

Processing updates

Feed
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate was first processed.

Raw data

{
  "_type": "sec_certs.sample.fips.FIPSCertificate",
  "cert_id": 261,
  "dgst": "e888a676e1926d0c",
  "heuristics": {
    "_type": "sec_certs.sample.fips.FIPSCertificate.Heuristics",
    "algorithms": {
      "_type": "Set",
      "elements": [
        "Skipjack#6",
        "Triple-DES#98",
        "Triple-DES MAC; DSA#58",
        "SHA-1#86"
      ]
    },
    "cpe_matches": null,
    "direct_transitive_cves": null,
    "extracted_versions": {
      "_type": "Set",
      "elements": [
        "-"
      ]
    },
    "indirect_transitive_cves": null,
    "module_processed_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "module_prunned_references": {
      "_type": "Set",
      "elements": []
    },
    "policy_processed_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": {
        "_type": "Set",
        "elements": [
          "1931",
          "476"
        ]
      },
      "directly_referencing": null,
      "indirectly_referenced_by": {
        "_type": "Set",
        "elements": [
          "1931",
          "476",
          "2640"
        ]
      },
      "indirectly_referencing": null
    },
    "policy_prunned_references": {
      "_type": "Set",
      "elements": []
    },
    "related_cves": null,
    "verified_cpe_matches": null
  },
  "pdf_data": {
    "_type": "sec_certs.sample.fips.FIPSCertificate.PdfData",
    "keywords": {
      "asymmetric_crypto": {
        "FF": {
          "DSA": {
            "DSA": 15
          }
        }
      },
      "certification_process": {},
      "cipher_mode": {},
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {},
      "crypto_scheme": {
        "KEX": {
          "Key Exchange": 13
        },
        "MAC": {
          "MAC": 3
        }
      },
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {},
      "fips_cert_id": {},
      "fips_certlike": {
        "Certlike": {
          "PKCS#1": 4,
          "SHA-1": 11
        }
      },
      "fips_security_level": {
        "Level": {
          "Level 3": 1
        }
      },
      "hash_function": {
        "SHA": {
          "SHA1": {
            "SHA-1": 11
          }
        }
      },
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {},
      "side_channel_analysis": {},
      "standard_id": {
        "FIPS": {
          "FIPS 140-1": 2,
          "FIPS PUB 140-1": 1,
          "FIPS PUB 180-1": 1,
          "FIPS PUB 186-2": 1,
          "FIPS PUB 46-3": 1
        },
        "PKCS": {
          "PKCS#1": 2
        }
      },
      "symmetric_crypto": {
        "DES": {
          "3DES": {
            "3DES": 3,
            "TDEA": 5,
            "TDES": 2
          },
          "DES": {
            "DEA": 5,
            "DES": 4
          }
        },
        "miscellaneous": {
          "Skipjack": {
            "Skipjack": 2
          }
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "policy_metadata": {
      "/Author": "David Collings",
      "/CreationDate": "D:20020919194841Z",
      "/Creator": "Acrobat PDFMaker 5.0 for Word",
      "/ModDate": "D:20021011100806-04\u002700\u0027",
      "/Producer": "Acrobat Distiller 5.0.5 (Windows)",
      "/Subject": "VA97004",
      "/Title": "Compliant Meter PSD Security Policy",
      "pdf_file_size_bytes": 544026,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 33
    }
  },
  "state": {
    "_type": "sec_certs.sample.fips.InternalState",
    "module": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": null,
      "txt_hash": null
    },
    "policy": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": "b9317922d811d905d08a6848ce22af43014288043ac2f0d2c6abda66ba985d50",
      "txt_hash": "79ee25a6b2bac815baf5f82f927fbd244a5d69aa5c3703dfc8aec372a2c638dc"
    }
  },
  "web_data": {
    "_type": "sec_certs.sample.fips.FIPSCertificate.WebData",
    "caveat": "None",
    "certificate_pdf_url": "https://csrc.nist.gov/CSRC/media/projects/cryptographic-module-validation-program/documents/certificates/140crt261.pdf",
    "date_sunset": null,
    "description": "The Pitney Bowes Compliant Meter Postal Security Device (PSD) has been designed in compliance with the United States Postal Service (USPS), Information-Based Indicia Program (IBIP). It employs strong encryption, decryption, and digital signature techniques for the protection of customer funds in Pitney Bowes IBIP Metering products. The PSD has been designed to support international postal markets and their rapidly evolving requirements for digital indicia.",
    "embodiment": "Multi-Chip Stand Alone",
    "exceptions": [
      "Physical Security: Level 3 +EFP"
    ],
    "fw_versions": null,
    "historical_reason": "Skipjack is no longer approved",
    "hw_versions": "Part number 1A00, Revisions AAA, AAB, AAC, AAD, and AAE.",
    "level": 3,
    "mentioned_certs": {},
    "module_name": "Compliant Meter Postal Security Device",
    "module_type": "Hardware",
    "revoked_link": null,
    "revoked_reason": null,
    "standard": "FIPS 140-1",
    "status": "historical",
    "sw_versions": null,
    "tested_conf": null,
    "validation_history": [
      {
        "_type": "sec_certs.sample.fips.FIPSCertificate.ValidationHistoryEntry",
        "date": "2002-10-11",
        "lab": "UL Verification Services, Inc.",
        "validation_type": "Initial"
      },
      {
        "_type": "sec_certs.sample.fips.FIPSCertificate.ValidationHistoryEntry",
        "date": "2002-10-21",
        "lab": "",
        "validation_type": "Update"
      },
      {
        "_type": "sec_certs.sample.fips.FIPSCertificate.ValidationHistoryEntry",
        "date": "2003-02-20",
        "lab": "",
        "validation_type": "Update"
      },
      {
        "_type": "sec_certs.sample.fips.FIPSCertificate.ValidationHistoryEntry",
        "date": "2003-03-07",
        "lab": "",
        "validation_type": "Update"
      }
    ],
    "vendor": "Pitney Bowes, Inc.",
    "vendor_url": "http://www.pb.com"
  }
}