ICU Medical CE3.0 OpenSSL Cryptographic Module

Certificate details

Certificate ID #4234
Status historical
Historical reason Moved to historical list due to sunsetting
Validation dates 24.05.2022
Standard FIPS 140-2
Security level 1
Type Software
Embodiment Multi-Chip Stand Alone
Caveat When operated in FIPS mode. No assurance of the minimum strength of generated keys
Exceptions
  • Physical Security: N/A
  • Mitigation of Other Attacks: N/A
Description ICU Medical CE3.0 OpenSSL Cryptographic Module 2.0.9.1 is used within various ICU Medical Plum360 Infusion Pumps for providing secure communication between Infusion pumps and external server.
Tested configurations
  • Android 2.3.7 running on ICU Medical Plum360 Infusion System with an i.MX53 Arm Cortex-A8 (single user mode)
Vendor ICU Medical, Inc. http://www.icumed.com
Lab UL Verification Services, Inc.
Algorithms
References

This certificate's webpage directly references 0 certificates, transitively this expands into 0 certificates.

Security policy

Extracted keywords

Symmetric Algorithms
AES, AES128, DES, Triple-DES, TDEA, HMAC, CMAC
Asymmetric Algorithms
ECDH, ECDSA, ECC, Diffie-Hellman, DSA
Hash functions
SHA-1, SHA1, SHA-224, SHA224, SHA256, SHA384, SHA512, SHA2, SHA-2
Schemes
MAC, Key Agreement, Key agreement
Protocols
TLS, TLSv1.2
Randomness
DRBG, RNG
Libraries
OpenSSL
Elliptic Curves
P-224, P-384, K-283, K-572, B-283
Block cipher modes
ECB, CBC, CTR, CFB, OFB, GCM, CCM, XTS

Security level
Level 1

Automated analysis

Automated inference - use with caution

All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. This applies equally to the Cross-references section below. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.

No automatically derived data are available in this section.

Cross-references

No references are available for this certificate.

Processing updates

Feed
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate data changed.
  • The certificate was first processed.

Raw data

{
  "_type": "sec_certs.sample.fips.FIPSCertificate",
  "cert_id": 4234,
  "dgst": "b2ca4c32632ea0ae",
  "heuristics": {
    "_type": "sec_certs.sample.fips.FIPSCertificate.Heuristics",
    "algorithms": {
      "_type": "Set",
      "elements": [
        "DRBG#A1878",
        "ECDSA#A1878",
        "#A1878",
        "SHS#A1878",
        "KAS#A1878",
        "AES#A1878",
        "HMAC#A1878",
        "RSA#A1878",
        "CVL#A1878",
        "KAS-SSC#A1878"
      ]
    },
    "cpe_matches": null,
    "direct_transitive_cves": null,
    "extracted_versions": {
      "_type": "Set",
      "elements": [
        "3.0"
      ]
    },
    "indirect_transitive_cves": null,
    "module_processed_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "module_prunned_references": {
      "_type": "Set",
      "elements": []
    },
    "policy_processed_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "policy_prunned_references": {
      "_type": "Set",
      "elements": []
    },
    "related_cves": null,
    "verified_cpe_matches": null
  },
  "pdf_data": {
    "_type": "sec_certs.sample.fips.FIPSCertificate.PdfData",
    "br1_deviations": 42,
    "br1_tables": null,
    "is_br1_format": false,
    "keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 2
          },
          "ECDH": {
            "ECDH": 1
          },
          "ECDSA": {
            "ECDSA": 16
          }
        },
        "FF": {
          "DH": {
            "Diffie-Hellman": 7
          },
          "DSA": {
            "DSA": 6
          }
        }
      },
      "certification_process": {},
      "cipher_mode": {
        "CBC": {
          "CBC": 4
        },
        "CCM": {
          "CCM": 5
        },
        "CFB": {
          "CFB": 4
        },
        "CTR": {
          "CTR": 2
        },
        "ECB": {
          "ECB": 3
        },
        "GCM": {
          "GCM": 6
        },
        "OFB": {
          "OFB": 2
        },
        "XTS": {
          "XTS": 3
        }
      },
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {
        "OpenSSL": {
          "OpenSSL": 19
        }
      },
      "crypto_protocol": {
        "TLS": {
          "TLS": {
            "TLS": 6,
            "TLSv1.2": 3
          }
        }
      },
      "crypto_scheme": {
        "KA": {
          "Key Agreement": 2,
          "Key agreement": 3
        },
        "MAC": {
          "MAC": 1
        }
      },
      "device_model": {},
      "ecc_curve": {
        "NIST": {
          "B-283": 2,
          "K-283": 2,
          "K-572": 2,
          "P-224": 4,
          "P-384": 4
        }
      },
      "eval_facility": {},
      "fips_cert_id": {},
      "fips_certlike": {
        "Certlike": {
          "AES 128/192/256": 2,
          "AES128": 1,
          "DRBG 3": 1,
          "DSA 5": 2,
          "HMAC 4": 2,
          "HMAC-SHA-1": 4,
          "HMACSHA1": 1,
          "PKCS1": 4,
          "SHA- 224": 1,
          "SHA-1": 2,
          "SHA-1, 224": 15,
          "SHA-2": 6,
          "SHA-224": 35,
          "SHA1": 17,
          "SHA1, 224": 3,
          "SHA2": 1,
          "SHA2 (224": 2,
          "SHA2-256": 2,
          "SHA2-384": 2,
          "SHA224": 1,
          "SHA256": 5,
          "SHA384": 3,
          "SHA512": 2
        }
      },
      "fips_security_level": {
        "Level": {
          "Level 1": 4
        }
      },
      "hash_function": {
        "SHA": {
          "SHA1": {
            "SHA-1": 17,
            "SHA1": 20
          },
          "SHA2": {
            "SHA-2": 6,
            "SHA-224": 35,
            "SHA2": 3,
            "SHA224": 1,
            "SHA256": 5,
            "SHA384": 3,
            "SHA512": 2
          }
        }
      },
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "PRNG": {
          "DRBG": 18
        },
        "RNG": {
          "RNG": 4
        }
      },
      "side_channel_analysis": {},
      "standard_id": {
        "FIPS": {
          "FIPS 140-2": 23,
          "FIPS 180-4": 2,
          "FIPS 186-2": 4,
          "FIPS 186-4": 5,
          "FIPS 197": 2,
          "FIPS 198-1": 2,
          "FIPS PUB 140-2": 1,
          "FIPS140-2": 3
        },
        "NIST": {
          "SP 800-131A": 2,
          "SP 800-38A": 1,
          "SP 800-38B": 2,
          "SP 800-38C": 2,
          "SP 800-38D": 2,
          "SP 800-38E": 1,
          "SP 800-56A": 4,
          "SP 800-56B": 1,
          "SP 800-67": 1,
          "SP 800-89": 1,
          "SP 800-90A": 3
        },
        "PKCS": {
          "PKCS1": 2
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 23,
            "AES128": 1
          }
        },
        "DES": {
          "3DES": {
            "TDEA": 1,
            "Triple-DES": 4
          },
          "DES": {
            "DES": 2
          }
        },
        "constructions": {
          "MAC": {
            "CMAC": 12,
            "HMAC": 8
          }
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {},
      "vulnerability": {}
    },
    "module_algorithms": {
      "_type": "Set",
      "elements": [
        "DRBG#A1878",
        "ECDSA#A1878",
        "SHS#A1878",
        "KAS#A1878",
        "AES#A1878",
        "HMAC#A1878",
        "RSA#A1878",
        "CVL#A1878",
        "KAS-SSC#A1878"
      ]
    },
    "policy_algorithms": {
      "_type": "Set",
      "elements": [
        "#A1878"
      ]
    },
    "policy_metadata": {
      "/Author": "[email protected]",
      "/Company": "Hospira, Inc.",
      "/ContentTypeId": "0x0101008C5B9B9B68FFBA41B886274865C2AEE6",
      "/CreationDate": "D:20220505153040-07\u002700\u0027",
      "/Creator": "Acrobat PDFMaker 17 for Word",
      "/ModDate": "D:20220505153046-07\u002700\u0027",
      "/Producer": "Adobe PDF Library 17.11.238",
      "/SourceModified": "D:20220505223022",
      "/Subject": "Sapphire LVP CE 3.1",
      "/Title": "820873-0006 Sapphire Large volume Pump communications interface",
      "/Topic": "",
      "pdf_file_size_bytes": 310885,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": [
          "http://csrc.nist.gov/publications/fips/fips197/fips-197.pdf",
          "http://csrc.nist.gov/publications/nistpubs/800-38C/SP800-38C_updated-July20_2007.pdf",
          "http://csrc.nist.gov/publications/nistpubs/800-38D/SP-800-38D.pdf",
          "http://csrc.nist.gov/publications/fips/fips140-2/fips1402.pdf",
          "http://csrc.nist.gov/publications/fips/fips186-3/fips_186-3.pdf",
          "http://csrc.nist.gov/publications/fips/fips180-3/fips180-3_final.pdf",
          "http://csrc.nist.gov/publications/nistpubs/800-56A/SP800-56A_Revision1_Mar08-2007.pdf",
          "http://csrc.nist.gov/publications/nistpubs/800-131A/sp800-131A.pdf",
          "http://csrc.nist.gov/publications/fips/fips198-1/FIPS-198-1_final.pdf",
          "http://csrc.nist.gov/publications/nistpubs/800-89/SP-800-89_November2006.pdf"
        ]
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 16
    }
  },
  "state": {
    "_type": "sec_certs.sample.fips.InternalState",
    "module": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": null,
      "source_hash": null,
      "txt_hash": null
    },
    "policy": {
      "_type": "sec_certs.sample.document_state.DocumentState",
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "json_hash": "ebd0a7cd0665f1f858da6d6299ffe2bbb713886887b87f6ea995bd26b3895e0c",
      "source_hash": "5027e65262a965b1ba80a77a857d62ca298fbb83bb7d9ed7c94b76b9bd717d15",
      "txt_hash": "aa90a2ee61a8938ded57a450194d3fb4602c0f2983f9fd9fb5d174aa84f7f693"
    }
  },
  "web_data": {
    "_type": "sec_certs.sample.fips.FIPSCertificate.WebData",
    "caveat": "When operated in FIPS mode. No assurance of the minimum strength of generated keys",
    "certificate_pdf_url": "https://csrc.nist.gov/CSRC/media/projects/cryptographic-module-validation-program/documents/certificates/May 2022_010622_0641_signed.pdf",
    "date_sunset": null,
    "description": "ICU Medical CE3.0 OpenSSL Cryptographic Module 2.0.9.1 is used within various ICU Medical Plum360 Infusion Pumps for providing secure communication between Infusion pumps and external server.",
    "embodiment": "Multi-Chip Stand Alone",
    "exceptions": [
      "Physical Security: N/A",
      "Mitigation of Other Attacks: N/A"
    ],
    "fw_versions": null,
    "historical_reason": "Moved to historical list due to sunsetting",
    "hw_versions": null,
    "level": 1,
    "mentioned_certs": {},
    "module_name": "ICU Medical CE3.0 OpenSSL Cryptographic Module",
    "module_type": "Software",
    "revoked_link": null,
    "revoked_reason": null,
    "standard": "FIPS 140-2",
    "status": "historical",
    "sw_versions": "2.0.9.1",
    "tested_conf": [
      "Android 2.3.7 running on ICU Medical Plum360 Infusion System with an i.MX53 Arm Cortex-A8 (single user mode)"
    ],
    "validation_history": [
      {
        "_type": "sec_certs.sample.fips.FIPSCertificate.ValidationHistoryEntry",
        "date": "2022-05-24",
        "lab": "UL Verification Services, Inc.",
        "validation_type": "Initial"
      }
    ],
    "vendor": "ICU Medical, Inc.",
    "vendor_url": "http://www.icumed.com"
  }
}