This page was not yet optimized for use on mobile
devices.
STSAFE-J100-BS Smart Meter Security Module V2.1.6
CSV information
| Status | archived |
|---|---|
| Valid from | 17.05.2018 |
| Valid until | 17.05.2023 |
| Scheme | 🇩🇪 DE |
| Manufacturer | STMicroelectronics |
| Category | ICs, Smart Cards and Smart Card-Related Devices and Systems |
| Security level | EAL4+, AVA_VAN.5 |
| Protection profiles |
Heuristics summary
Certificate ID: BSI-DSZ-CC-1037-2018
Certificate
certificate file processing did not finish successfully.
Show more...
Download pdf:
OK
Convert pdf to text:
OK
Extract keywords:
ERROR
Extracted keywords
Vendor
STMicroelectronicsSecurity level
EAL 4, EAL 5, EAL 2, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR, AVA_VAN.5Protection profiles
BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-1037-2018Standards
ISO/IEC 15408, ISO/IEC 18045Certification report
Extracted keywords
Symmetric Algorithms
AES, CMACAsymmetric Algorithms
ECDSA, ECC, Diffie-HellmanHash functions
JHSchemes
Key Agreement, Key agreementProtocols
TLS, PACE, PGPRandomness
TRNG, DRBG, RNGBlock cipher modes
CBCVendor
STMicroelectronicsSecurity level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 2+, EAL 5+, EAL 6, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ADV_ARC, ALC_FLR, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VANProtection profiles
BSI-CC-PP-0077-V2-2015, BSI-CCPP-0073-2014Certificates
BSI-DSZ-CC-1037-2018, ANSSI-CC-2017/23Evaluation facilities
SERMA, TÜV Informationstechnik, TÜViTSide-channel analysis
JILCertification process
being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, Version Rev.I, September 19th , 2017, STSAFE-J100-BS Security Target, STMicroelectronics (confidential document) [7] Evaluation Technical Report, Version 4, April 17th , 2018, Evaluation Technical Report Summary, TÜV Informationstechnik GmbH, (confidential document) [8] Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) -, public document) [10] Configuration list for the TOE, Version 2.1.6, Kerkey2 SMARAGD ConfigList (confidential document) [11] Operational Guidance documentation for the TOE, Rev. E, STSAFE-J100-BS – Operational userStandards
FIPS197, FIPS PUB 180-2, FIPS PUB 186-3, FIPS PUB 197, AIS 34, AIS 36, AIS 26, AIS 20, AIS 35, AIS 1, AIS 14, AIS 19, AIS 23, AIS 32, AIS 37, AIS 45, AIS 46, RFC4493, RFC 4493, RFC 5639, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065, ISO/IEC 10116Technical reports
BSI 7148File metadata
| Title | Certification Report BSI-DSZ-CC-1037-2018 |
|---|---|
| Subject | STSAFE-J100-BS Security Module for Smart Metering V01.03 |
| Keywords | "Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, STSAFE, STM" |
| Author | Bundesamt für Sicherheit in der Informationstechnik |
| Creation date | D:20180523121939+02'00' |
| Modification date | D:20180523123310+02'00' |
| Pages | 27 |
| Creator | Writer |
| Producer | LibreOffice 5.2 |
Frontpage
| Certificate ID | BSI-DSZ-CC-1037-2018 |
|---|---|
| Certified item | STSAFE-J100-BS Smart Meter Security Module V2.1.6 |
| Certification lab | BSI |
| Developer | STMicroelectronics |
References
Outgoing- ANSSI-CC-2017/23 - archived - Plate-forme STSAFE-J, en configuration fermée, version 1.1.4, sur le composant ST31H320 A03
Security target
Extracted keywords
Symmetric Algorithms
AES, CMACAsymmetric Algorithms
ECDH, ECDSA, ECC, Diffie-Hellman, DHHash functions
JHSchemes
MAC, Key Agreement, Key agreementProtocols
TLS, PACERandomness
TRNG, DRBG, RNGElliptic Curves
P-256, P-384, NIST P-256, NIST P-384, secp256r1, secp384r1, brainpoolP256r1, brainpoolP384r1, brainpoolP512r1Block cipher modes
CBCVendor
STMicroelectronicsSecurity level
EAL 4, EAL5+, EAL4, EAL5, EAL4 augmented, EAL5 augmentedClaims
O.PACE, O.OPERATE, O.SCP, O.CIPHER, O.TRANSACTION, O.SIDE_CHANNEL, O.PIN-MNGT, O.ALARM, O.SID, O.ROLES, O.GLOBAL_ARRAYS_INTEG, O.NATIVE, O.LIFE_CYCLE, O.RESOURCES, O.FIREWALL, OE.PACE, OSP.SMSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE.1, AGD_PRE.1, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ALC_DVS.2, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5, AVA_VAN.3, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1Security Functional Requirements (SFR)
FCS_RNG, FCS_CKM.1, FCS_COP.1, FCS_RNG.1, FCS_RNG.1.1, FCS_RNG.1.2, FCS_CKM, FCS_CKM.4, FCS_COP, FCS_CKM.2, FCS_CKM.4.1, FDP_ACF, FDP_ACC.2, FDP_ACF.1, FDP_SDI.2, FDP_RIP.1, FDP_ETC.1, FDP_ITC.1, FDP_UCT.1, FDP_UIT.1, FDP_ITC.2, FDP_ACC.1, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_SDI.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_RIP.1.1, FDP_IFC, FDP_ETC.1.1, FDP_ETC.1.2, FDP_IFC.1, FDP_ITC.1.1, FDP_ITC.1.2, FDP_ITC.1.3, FDP_UIT.1.2, FDP_ITC, FIA_ATD.1, FIA_SOS.1, FIA_UAU, FIA_UAU.4, FIA_UAU.5, FIA_UID.1, FIA_USB.1, FIA_ATD.1.1, FIA_SOS.1.1, FIA_UAU.1, FIA_UAU.4.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UID.1.1, FIA_UID.1.2, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_LIM, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA.3, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FPT_EMS, FPT_EMS.1, FPT_EMS.1.1, FPT_EMS.1.2, FPT_FLS.1, FPT_PHP.3, FPT_TST.1, FPT_FLS.1.1, FPT_PHP.3.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FTP_ITC.1, FTP_TRP.1, FTP_ITC.1.1, FTP_ITC.1.2, FTP_ITC.1.3, FTP_ICT.1Protection profiles
BSI-CC-PP-0084-2014, BSI-CC-PP-0077-V2, ANSSI-CC-PP-2010/07-M01Certificates
ANSSI-CC-PP-2010/07-M01, ANSSI-CC-2015/59-M01, ANSSI-CC-2015/59-S01, ANSSI-CC-2017/23, ANSSI-CC-2015/59Side-channel analysis
physical probing, side channels, side channel, DPA, SPA, timing attacks, Physical tampering, physical tampering, Malfunction, malfunction, DFA, fault injectionCertification process
out of scope, entities. 62 As these external entities only indirectly interact with the TOE, these entities are out of scope for this ST. 63 During its pre-operational phases the TOE interacts with the Integrator and theStandards
FIPS186, FIPS197, AIS 31, AIS36, AIS 36, RFC4493, RFC5639, RFC 5639, ISO/IEC 10116, ISO/IEC 7810:2003, X.509, CCMB-2012-09-001, CCMB-2012-09-004, CCMB-2012-09-002, CCMB-2012-09-003Technical reports
BSI TR-03109, BSI TR-03109-2, BSI TR-03116-3File metadata
| Title | STSAFE-J100-BS_SecurtyTarget_LITE |
|---|---|
| Subject | The document is the security target public version of the of a security module for a smart meter gateway- Product Name STSAFE-J100-BS - Company STMicroelectronics |
| Keywords | Elliptic Curve Cryptography, Gateway, Gateway administrator, Key Derivation Function, Personal Identification Number, Random Number Generator, Security Functional Requirement, Security Function, Security module, Smart meter, Secure Hash Algorithm,Target Of Evaluation |
| Author | Saverio Donatiello - STMicroelectronics |
| Creation date | D:20180416181359+02'00' |
| Modification date | D:20180416181359+02'00' |
| Pages | 72 |
| Creator | PDFCreator 2.0.0.0 |
| Producer | PDFCreator 2.0.0.0 |
References
Outgoing- ANSSI-CC-2017/23 - archived - Plate-forme STSAFE-J, en configuration fermée, version 1.1.4, sur le composant ST31H320 A03
- ANSSI-CC-2015/59 - archived - ST31H320 A01 including optional cryptographic library NESLIB
Heuristics
Automated inference - use with caution
All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. For details on our data sources and inference methods, see our methodology. If you believe any information here is inaccurate or harmful, please submit feedback.Certificate ID
BSI-DSZ-CC-1037-2018Extracted SARs
ADV_ARC.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE.1, AGD_PRE.1, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.2, ALC_LCD.1, ALC_TAT.1, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5References
Loading...
Updates Feed
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate was first processed.
Raw data
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
"cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1037c_pdf.pdf",
"dgst": "8150f131f14ae24a",
"heuristics": {
"_type": "sec_certs.sample.cc_eucc_common.Heuristics",
"annotated_references": null,
"cert_id": "BSI-DSZ-CC-1037-2018",
"cert_lab": [
"BSI"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"eal": "EAL4+",
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_SPD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_INT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_ECD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_IND",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DVS",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMS",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_FUN",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_TDS",
"level": 3
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_TSS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMC",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_REQ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_OBJ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DEL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_LCD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_PRE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_TAT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_CCL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_DPT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_OPE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COV",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_IMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_FSP",
"level": 4
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"2.1.6"
]
},
"indirect_transitive_cves": null,
"next_certificates": null,
"prev_certificates": null,
"protection_profiles": {
"_type": "Set",
"elements": [
"15eda6dafddbf8ca"
]
},
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2017/23"
]
},
"indirectly_referenced_by": null,
"indirectly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2017/23",
"ANSSI-CC-2015/59",
"ANSSI-CC-2017/10"
]
}
},
"scheme_data": null,
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2017/23",
"ANSSI-CC-2015/59"
]
},
"indirectly_referenced_by": null,
"indirectly_referencing": {
"_type": "Set",
"elements": [
"ANSSI-CC-2017/23",
"ANSSI-CC-2015/59"
]
}
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": []
},
"manufacturer": "STMicroelectronics",
"manufacturer_web": "https://www.st.com/",
"name": "STSAFE-J100-BS Smart Meter Security Module V2.1.6",
"not_valid_after": "2023-05-17",
"not_valid_before": "2018-05-17",
"pdf_data": {
"_type": "sec_certs.sample.cc_eucc_common.PdfData",
"cert_filename": "1037c_pdf.pdf",
"cert_frontpage": null,
"cert_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-1037-2018": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077-V2-2015": 1
}
},
"cc_sar": {
"ALC": {
"ALC_FLR": 1
},
"AVA": {
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 2": 1,
"EAL 4": 1,
"EAL 4 augmented": 1,
"EAL 5": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"ISO": {
"ISO/IEC 15408": 2,
"ISO/IEC 18045": 2
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"STMicroelectronics": {
"STMicroelectronics": 1
}
},
"vulnerability": {}
},
"cert_metadata": null,
"report_filename": "1037a_pdf.pdf",
"report_frontpage": {
"DE": {
"cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5",
"cc_version": "PP conformant Common Criteria Part 2 extended",
"cert_id": "BSI-DSZ-CC-1037-2018",
"cert_item": "STSAFE-J100-BS Smart Meter Security Module V2.1.6",
"cert_lab": "BSI",
"developer": "STMicroelectronics",
"match_rules": [
"(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
],
"ref_protection_profiles": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil f\u00fcr das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015"
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 1
},
"ECDSA": {
"ECDSA": 3
}
},
"FF": {
"DH": {
"Diffie-Hellman": 1
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-1037-2018": 16
},
"FR": {
"ANSSI-CC-2017/23": 2
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077-V2-2015": 4,
"BSI-CCPP-0073-2014": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC": 1
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS.1": 1,
"ALC_FLR": 3,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"ATE": {
"ATE_FUN": 1,
"ATE_IND": 1
},
"AVA": {
"AVA_VAN": 3,
"AVA_VAN.5": 4
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 2": 2,
"EAL 2+": 1,
"EAL 4": 5,
"EAL 4 augmented": 3,
"EAL 5": 4,
"EAL 5+": 1,
"EAL 6": 1
}
},
"cc_sfr": {},
"certification_process": {
"ConfidentialDocument": {
"T\u00dcV Informationstechnik GmbH, (confidential document) [8] Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) -": 1,
"Version Rev.I, September 19th , 2017, STSAFE-J100-BS Security Target, STMicroelectronics (confidential document) [7] Evaluation Technical Report, Version 4, April 17th , 2018, Evaluation Technical Report Summary": 1,
"being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1,
"public document) [10] Configuration list for the TOE, Version 2.1.6, Kerkey2 SMARAGD ConfigList (confidential document) [11] Operational Guidance documentation for the TOE, Rev. E, STSAFE-J100-BS \u2013 Operational user": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 2
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 6
},
"PGP": {
"PGP": 1
},
"TLS": {
"TLS": {
"TLS": 2
}
}
},
"crypto_scheme": {
"KA": {
"Key Agreement": 8,
"Key agreement": 1
}
},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"Serma": {
"SERMA": 1
},
"TUV": {
"T\u00dcV Informationstechnik": 3,
"T\u00dcViT": 1
}
},
"hash_function": {
"JH": {
"JH": 1
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"PRNG": {
"DRBG": 1
},
"RNG": {
"RNG": 3
},
"TRNG": {
"TRNG": 1
}
},
"side_channel_analysis": {
"other": {
"JIL": 3
}
},
"standard_id": {
"BSI": {
"AIS 1": 1,
"AIS 14": 1,
"AIS 19": 1,
"AIS 20": 2,
"AIS 23": 1,
"AIS 26": 2,
"AIS 32": 1,
"AIS 34": 2,
"AIS 35": 2,
"AIS 36": 2,
"AIS 37": 1,
"AIS 45": 1,
"AIS 46": 1
},
"FIPS": {
"FIPS PUB 180-2": 1,
"FIPS PUB 186-3": 1,
"FIPS PUB 197": 1,
"FIPS197": 2
},
"ISO": {
"ISO/IEC 10116": 2,
"ISO/IEC 15408": 4,
"ISO/IEC 17065": 2,
"ISO/IEC 18045": 4
},
"RFC": {
"RFC 4493": 1,
"RFC 5639": 1,
"RFC4493": 1
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 7
}
},
"constructions": {
"MAC": {
"CMAC": 2
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7148": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"STMicroelectronics": {
"STMicroelectronics": 15
}
},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20180523121939+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, STSAFE, STM\"",
"/ModDate": "D:20180523123310+02\u002700\u0027",
"/Producer": "LibreOffice 5.2",
"/Subject": "STSAFE-J100-BS Security Module for Smart Metering V01.03",
"/Title": "Certification Report BSI-DSZ-CC-1037-2018",
"pdf_file_size_bytes": 796336,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"http://www.commoncriteriaportal.org/",
"http://www.sogisportal.eu/",
"https://www.bsi.bund.de/AIS",
"https://www.bsi.bund.de/",
"https://www.bsi.bund.de/zertifizierungsreporte",
"https://www.bsi.bund.de/zertifizierung",
"http://www.commoncriteriaportal.org/cc/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 27
},
"st_filename": "1037b_pdf.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 12
},
"ECDH": {
"ECDH": 1
},
"ECDSA": {
"ECDSA": 23
}
},
"FF": {
"DH": {
"DH": 17,
"Diffie-Hellman": 3
}
}
},
"cc_cert_id": {
"FR": {
"ANSSI-CC-2015/59": 1,
"ANSSI-CC-2015/59-M01": 1,
"ANSSI-CC-2015/59-S01": 1,
"ANSSI-CC-2017/23": 1,
"ANSSI-CC-PP-2010/07-M01": 1
}
},
"cc_claims": {
"O": {
"O.ALARM": 1,
"O.CIPHER": 1,
"O.FIREWALL": 1,
"O.GLOBAL_ARRAYS_INTEG": 1,
"O.LIFE_CYCLE": 1,
"O.NATIVE": 1,
"O.OPERATE": 1,
"O.PACE": 10,
"O.PIN-MNGT": 1,
"O.RESOURCES": 1,
"O.ROLES": 1,
"O.SCP": 3,
"O.SID": 1,
"O.SIDE_CHANNEL": 1,
"O.TRANSACTION": 1
},
"OE": {
"OE.PACE": 4
},
"OSP": {
"OSP.SM": 1
}
},
"cc_protection_profile_id": {
"ANSSI": {
"ANSSI-CC-PP-2010/07-M01": 1
},
"BSI": {
"BSI-CC-PP-0077-V2": 2,
"BSI-CC-PP-0084-2014": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_FSP.4": 1,
"ADV_IMP.1": 1,
"ADV_TDS.3": 1
},
"AGD": {
"AGD_OPE.1": 1,
"AGD_PRE.1": 1
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS.1": 1,
"ALC_DVS.2": 1,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_ECD.1": 1,
"ASE_INT.1": 1,
"ASE_OBJ.2": 1,
"ASE_REQ.2": 1,
"ASE_SPD.1": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_DPT.1": 1,
"ATE_FUN.1": 1,
"ATE_IND.2": 1
},
"AVA": {
"AVA_VAN.3": 1,
"AVA_VAN.5": 11
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 5,
"EAL4": 6,
"EAL4 augmented": 2,
"EAL5": 1,
"EAL5 augmented": 1,
"EAL5+": 1
}
},
"cc_sfr": {
"FCS": {
"FCS_CKM": 57,
"FCS_CKM.1": 16,
"FCS_CKM.2": 8,
"FCS_CKM.4": 48,
"FCS_CKM.4.1": 1,
"FCS_COP": 47,
"FCS_COP.1": 13,
"FCS_RNG": 5,
"FCS_RNG.1": 16,
"FCS_RNG.1.1": 2,
"FCS_RNG.1.2": 2
},
"FDP": {
"FDP_ACC.1": 11,
"FDP_ACC.2": 17,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 1,
"FDP_ACF.1": 9,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_ETC.1": 6,
"FDP_ETC.1.1": 1,
"FDP_ETC.1.2": 1,
"FDP_IFC": 1,
"FDP_IFC.1": 7,
"FDP_ITC": 7,
"FDP_ITC.1": 19,
"FDP_ITC.1.1": 1,
"FDP_ITC.1.2": 1,
"FDP_ITC.1.3": 1,
"FDP_ITC.2": 14,
"FDP_RIP.1": 12,
"FDP_RIP.1.1": 1,
"FDP_SDI.1": 1,
"FDP_SDI.2": 11,
"FDP_SDI.2.1": 2,
"FDP_SDI.2.2": 1,
"FDP_UCT.1": 7,
"FDP_UIT.1": 7,
"FDP_UIT.1.2": 1
},
"FIA": {
"FIA_ATD.1": 9,
"FIA_ATD.1.1": 1,
"FIA_SOS.1": 6,
"FIA_SOS.1.1": 2,
"FIA_UAU": 14,
"FIA_UAU.1": 4,
"FIA_UAU.4": 6,
"FIA_UAU.4.1": 1,
"FIA_UAU.5": 6,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UID.1": 14,
"FIA_UID.1.1": 1,
"FIA_UID.1.2": 1,
"FIA_USB.1": 6,
"FIA_USB.1.1": 1,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_LIM": 5,
"FMT_LIM.1": 22,
"FMT_LIM.1.1": 2,
"FMT_LIM.2": 19,
"FMT_LIM.2.1": 2,
"FMT_MSA.3": 4,
"FMT_SMF.1": 9,
"FMT_SMF.1.1": 1,
"FMT_SMR.1": 8,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPT": {
"FPT_EMS": 5,
"FPT_EMS.1": 18,
"FPT_EMS.1.1": 2,
"FPT_EMS.1.2": 2,
"FPT_FLS.1": 15,
"FPT_FLS.1.1": 1,
"FPT_PHP.3": 14,
"FPT_PHP.3.1": 1,
"FPT_TST.1": 15,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ICT.1": 4,
"FTP_ITC.1": 13,
"FTP_ITC.1.1": 1,
"FTP_ITC.1.2": 1,
"FTP_ITC.1.3": 1,
"FTP_TRP.1": 4
}
},
"certification_process": {
"OutOfScope": {
"entities. 62 As these external entities only indirectly interact with the TOE, these entities are out of scope for this ST. 63 During its pre-operational phases the TOE interacts with the Integrator and the": 1,
"out of scope": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 9
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 67
},
"TLS": {
"TLS": {
"TLS": 26
}
}
},
"crypto_scheme": {
"KA": {
"Key Agreement": 19,
"Key agreement": 2
},
"MAC": {
"MAC": 1
}
},
"device_model": {},
"ecc_curve": {
"Brainpool": {
"brainpoolP256r1": 2,
"brainpoolP384r1": 2,
"brainpoolP512r1": 2
},
"NIST": {
"NIST P-256": 1,
"NIST P-384": 1,
"P-256": 3,
"P-384": 3,
"secp256r1": 1,
"secp384r1": 1
}
},
"eval_facility": {},
"hash_function": {
"JH": {
"JH": 1
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"PRNG": {
"DRBG": 1
},
"RNG": {
"RNG": 9
},
"TRNG": {
"TRNG": 2
}
},
"side_channel_analysis": {
"FI": {
"DFA": 1,
"Malfunction": 12,
"Physical tampering": 1,
"fault injection": 1,
"malfunction": 3,
"physical tampering": 7
},
"SCA": {
"DPA": 2,
"SPA": 2,
"physical probing": 2,
"side channel": 3,
"side channels": 1,
"timing attacks": 1
}
},
"standard_id": {
"BSI": {
"AIS 31": 1,
"AIS 36": 1,
"AIS36": 2
},
"CC": {
"CCMB-2012-09-001": 2,
"CCMB-2012-09-002": 1,
"CCMB-2012-09-003": 1,
"CCMB-2012-09-004": 2
},
"FIPS": {
"FIPS186": 11,
"FIPS197": 7
},
"ISO": {
"ISO/IEC 10116": 2,
"ISO/IEC 7810:2003": 1
},
"RFC": {
"RFC 5639": 1,
"RFC4493": 4,
"RFC5639": 10
},
"X509": {
"X.509": 2
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 20
}
},
"constructions": {
"MAC": {
"CMAC": 5
}
}
},
"technical_report_id": {
"BSI": {
"BSI TR-03109": 1,
"BSI TR-03109-2": 1,
"BSI TR-03116-3": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"STMicroelectronics": {
"STMicroelectronics": 15
}
},
"vulnerability": {}
},
"st_metadata": {
"/Author": "Saverio Donatiello - STMicroelectronics",
"/CreationDate": "D:20180416181359+02\u002700\u0027",
"/Creator": "PDFCreator 2.0.0.0",
"/Keywords": "Elliptic Curve Cryptography, Gateway, Gateway administrator, Key Derivation Function, Personal Identification Number, Random Number Generator, Security Functional Requirement, Security Function, Security module, Smart meter, Secure Hash Algorithm,Target Of Evaluation",
"/ModDate": "D:20180416181359+02\u002700\u0027",
"/Producer": "PDFCreator 2.0.0.0",
"/Subject": "The document is the security target public version of the of a security module for a smart meter gateway- Product Name STSAFE-J100-BS - Company STMicroelectronics",
"/Title": "STSAFE-J100-BS_SecurtyTarget_LITE",
"pdf_file_size_bytes": 543894,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 72
}
},
"protection_profile_links": {
"_type": "Set",
"elements": [
"https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0077V2b_pdf.pdf"
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1037a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"AVA_VAN.5",
"EAL4+"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1037b_pdf.pdf",
"state": {
"_type": "sec_certs.sample.cc_eucc_common.InternalState",
"cert": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": false,
"json_hash": null,
"pdf_hash": "16351da4f798f6fd2561e4d664998114ed8c387a05d2f9a1a11191daa33658bb",
"txt_hash": "5096f8df4bbddb9fd90425cf94f0ab4109601967a8fa37301a44863203cfc8c8"
},
"report": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"pdf_hash": "6f066b6e8f8867c348b7a261a1380b35d3e1a700cb2d1f60439c300452cf08c5",
"txt_hash": "2da2714404c613cf9a0c0b84920900ed9bd0cc251967c6bc8259a8233c3d2b31"
},
"st": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": null,
"pdf_hash": "f5ab7a82b4d646d6e3eb25b9be8a6183ff49b93bb5bc395d2822986ef2362da3",
"txt_hash": "cdada41f4dfae942cf9bc28c476310e327b842cfd9c797bdfbe1a16083c53c70"
}
},
"status": "archived"
}