This page was not yet optimized for use on mobile devices.
Smart Meter Gateway Security Module Application on MultiApp V4 Revision A
Certificate details
| Status | active |
|---|---|
| Valid from | 18.09.2018 |
| Valid until | 18.09.2028 |
| Scheme | 🇩🇪 DE |
| Manufacturer | Gemalto |
| Category | ICs, Smart Cards and Smart Card-Related Devices and Systems |
| Security level | AVA_VAN.5, EAL4 |
| Protection profiles |
Certificate
Extracted keywords
Vendor
GemaltoSecurity level
EAL 4, EAL 5, EAL 2, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR, AVA_VAN.5Protection profiles
BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-1003-2018Certification report
Extracted keywords
Symmetric Algorithms
AES, CMACAsymmetric Algorithms
ECDSA, ECC, DH, Diffie-HellmanHash functions
SHA-2, JHSchemes
MAC, Key Agreement, KAProtocols
TLS, PACERandomness
RNGBlock cipher modes
CBCVendor
Infineon, Infineon Technologies AG, GemaltoSecurity level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 2+, EAL 5+, EAL 6, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ADV_ARC, ADV_COMP.1, AGD_PRE, AGD_OPE, ALC_FLR, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, AVA_VAN.5, AVA_VANSecurity Functional Requirements (SFR)
FCS_COP, FCS_CKM, FCS_RNG.1, FIA_UID.1, FIA_UAU.4, FIA_UAU.5, FTP_ITC.1Protection profiles
BSI-CC-PP-0077-V2-2015, BSI-CC-PP0077-V2-2015, BSI-CCPP-0077-V2-2015Certificates
BSI-DSZ-CC-1003-2018, BSI-DSZ-CC-0891-V2-2016, ANSSI-CC-2017/54Evaluation facilities
Serma Safety & Security, TÜV InformationstechnikSide-channel analysis
malfunction, JILCertification process
being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, Target of Security Module for Smart Meter Gateway, D1359877, Version 2.1, 3 August 2018, Gemalto (confidential document, Application on MultiApp V4 Revision A, Version 3, 10 August 2018, TÜV Informationstechnik GmbH (confidential document, v1.1,Version 1.2, 3 August 2018, and File LIS_SMGWSMV11_CAR_LBL03_1.65.1.7.1.5.1.20, Gemalto (confidential documentStandards
FIPS 180-4, FIPS 186-3, FIPS 197, FIPS PUB 180-4, FIPS PUB 186-3, FIPS PUB 197, AIS 34, AIS 36, AIS 26, AIS 25, AIS 20, AIS 31, AIS 35, AIS 1, AIS 14, AIS 19, AIS 32, AIS 37, AIS 38, AIS 46, RFC 5639, RFC 4493, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065, ISO/IEC 10116, ISO/IEC 7816-4Technical reports
BSI TR-3109-2, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03116-3, BSI TR-03110-2, BSI TR-03110-3, BSI 7148Frontpage
| Certificate ID | BSI-DSZ-CC-1003-2018 |
|---|---|
| Certified item | on MultiApp V4 Revision A |
| Certification lab | BSI |
| Developer | ## Gemalto SA BSI - |
Cross-references
Outgoing- BSI-DSZ-CC-0891-V2-2016 - archived - Infineon Security Controller, M7892 Design Steps D11 and G12, with optional RSA2048/4096 v2.03.008, EC v2.03.008, SHA-2 v1.01 and Toolbox v2.03.008 libraries, symmetric crypto library v2.02.010 and with specific IC dedicated software (firmware)
- ANSSI-CC-2017/54 - archived - Plateforme JavaCard MultiApp V4.0 - PACE en configuration ouverte basée sur l'Operating System JLEP3 masquée sur le composant SLE78CLFX4000PH (M7892 G12)
Security target
Extracted keywords
Symmetric Algorithms
AES, DES, CMACAsymmetric Algorithms
ECDH, ECDSA, ECC, Diffie-Hellman, DHSchemes
MAC, Key Exchange, Key AgreementProtocols
TLS, PACE, IKERandomness
RNG, RNDElliptic Curves
P-256, P-384, NIST P-256, NIST P-384, secp256r1, secp384r1, brainpoolP256r1, brainpoolP384r1, brainpoolP512r1Block cipher modes
CBCCPLC
IC Fabricator, IC TypeVendor
Infineon, GemaltoSecurity level
EAL 4, EAL 5, EAL4, EAL 5 augmented, EAL4 augmentedClaims
O.PACE, T.CONFID-JCS-CODE, T.CONFID-JCS-DATA, T.INTEG-JCS-CODE, T.INTEG-JCS-DATA, T.INTEG-APPLI-DATA, T.SID, T.EXE-CODE, T.NATIVE, T.INSTALL, T.OBJ-DELETION, T.RESOURCES, T.CONFID-APPLI-DATA, T.INTEG-APPLI-CODE, T.PHYSICAL, A.VERIFICATION, A.APPLET, OE.PACE, OSP.SM, OSP.VERIFICATION, OSP.RNDSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE_PLTF, AGD_OPE, AGD_PRE_PLTF, AGD_PRE, AGD_OPE_SMGW, AGD_PRE_SMGW, AGD_OPE.1, AGD_PRE.1, ALC_DVS, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5, AVA_VAN, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1Security Functional Requirements (SFR)
FCS_RNG, FCS_RNG.1, FCS_RNG.1.1, FCS_RNG.1.2, FCS_CKM, FCS_CKM.4, FCS_COP, FCS_CKM.1, FCS_COP.1, FCS_CKM.2, FCS_CKM.4.1, FDP_ACF, FDP_ACC.2, FDP_ACF.1, FDP_SDI.2, FDP_RIP.1, FDP_ETC.1, FDP_ITC.1, FDP_UCT.1, FDP_UIT.1, FDP_ITC.2, FDP_ACC, FDP_ACC.1, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_SDI, FDP_SDI.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_RIP, FDP_RIP.1.1, FDP_ETC, FDP_ETC.1.1, FDP_ETC.1.2, FDP_IFC.1, FDP_ITC, FDP_ITC.1.1, FDP_ITC.1.2, FDP_ITC.1.3, FDP_UCT, FDP_UCT.1.1, FDP_UIT, FDP_UIT.1.1, FDP_UIT.1.2, FIA_ATD.1, FIA_SOS.1, FIA_UAU, FIA_UAU.4, FIA_UAU.5, FIA_UID.1, FIA_USB.1, FIA_ATD, FIA_ATD.1.1, FIA_SOS, FIA_SOS.1.1, FIA_UAU.1, FIA_UAU.4.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UID, FIA_UID.1.1, FIA_UID.1.2, FIA_USB, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FMT_LIM, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA.3, FMT_SMF, FMT_SMF.1.1, FMT_SMR, FMT_SMR.1.1, FMT_SMR.1.2, FPT_EMS, FPT_EMS.1, FPT_EMS.1.1, FPT_EMS.1.2, FPT_FLS.1, FPT_PHP.3, FPT_TST.1, FPT_FLS, FPT_FLS.1.1, FPT_PHP, FPT_PHP.3.1, FPT_TST, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FTP_ITC.1, FTP_TRP.1, FTP_ITC, FTP_ITC.1.1, FTP_ITC.1.2, FTP_ITC.1.3Protection profiles
BSI-CC-PP- 0084-2014, BSI-CC-PP-0073-2014, BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-1003-2017, BSI-DSZ-CC-1003-2018, BSI-DSZ-CC-0891-V2-2016, ANSSI-CC-2017/54, CC-1, CC-2, CC-3Side-channel analysis
physical probing, side channels, side channel, DPA, SPA, timing attacks, physical tampering, Physical Tampering, Malfunction, malfunction, DFA, fault injectionCertification process
out of scope, As these external entities do not directly interact with the TOE, these entities are out of scope for this STStandards
FIPS180-4, FIPS186, FIPS PUB 186-3, FIPS197, FIPS46-3, FIPS PUB 46-3, FIPS 197, PKCS#3, AIS31, AIS 31, AIS36, AIS 36, AIS 20, RFC 2409, RFC 4493, RFC 4993, RFC5639, RFC 5639, ISO/IEC 10116, X.509, CCMB-2012-09-001, CCMB-2012-09-002, CCMB-2012-09-003Technical reports
BSI TR-03109-3, BSI TR-03110-1, BSI TR-03110-2, BSI TR-03110-3, BSI TR-03116-3Cross-references
Outgoing- BSI-DSZ-CC-0891-V2-2016 - archived - Infineon Security Controller, M7892 Design Steps D11 and G12, with optional RSA2048/4096 v2.03.008, EC v2.03.008, SHA-2 v1.01 and Toolbox v2.03.008 libraries, symmetric crypto library v2.02.010 and with specific IC dedicated software (firmware)
- ANSSI-CC-2017/54 - archived - Plateforme JavaCard MultiApp V4.0 - PACE en configuration ouverte basée sur l'Operating System JLEP3 masquée sur le composant SLE78CLFX4000PH (M7892 G12)
- BSI-DSZ-CC-1000-V2-2025 - active - Secure Smart Grid Hub (SGH-S), V1.02
- BSI-DSZ-CC-1000-2023 - active - Secure Smart Grid Hub (SGH-S), V1.00
Automated analysis
Automated inference - use with caution
All attributes shown in this section (e.g., links between certificates, products, vendors, and known CVEs) are generated by automated heuristics and have not been reviewed by humans. These methods can produce false positives or false negatives and should not be treated as definitive without independent verification. This applies equally to the Cross-references section below. If you want to know more about how this data is computed and how reliable it is, see our documentation on automated analysis. If you believe any information here is inaccurate or harmful, please submit feedback.Certificate ID
BSI-DSZ-CC-1003-2018Extracted SARs
ADV_ARC.1, ADV_COMP.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE.1, AGD_PRE.1, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5Cross-references
Loading...
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate data changed.
-
The certificate was first processed.
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
"cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003c_pdf.pdf",
"dgst": "969f3d54aa5e2ed8",
"heuristics": {
"_type": "sec_certs.sample.cc_eucc_common.Heuristics",
"annotated_references": null,
"cert_id": "BSI-DSZ-CC-1003-2018",
"cert_lab": [
"BSI"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"eal": "EAL4",
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_PRE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_TAT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_LCD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_OBJ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_DPT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_FSP",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DVS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMC",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_FUN",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_REQ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_OPE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_ECD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DEL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_SPD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_TSS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMS",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_IMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COV",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_IND",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_INT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_TDS",
"level": 3
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_CCL",
"level": 1
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"-"
]
},
"indirect_transitive_cves": null,
"next_certificates": null,
"prev_certificates": null,
"protection_profiles": {
"_type": "Set",
"elements": [
"15eda6dafddbf8ca"
]
},
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/54"
]
},
"indirectly_referenced_by": null,
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0782-2012",
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/07",
"ANSSI-CC-2017/54",
"BSI-DSZ-CC-0891-2015"
]
}
},
"scheme_data": null,
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-1000-2023",
"BSI-DSZ-CC-1000-V2-2025"
]
},
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/54"
]
},
"indirectly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-1000-2023",
"BSI-DSZ-CC-1000-V2-2025"
]
},
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/54"
]
}
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": []
},
"manufacturer": "Gemalto",
"manufacturer_web": "https://www.gemalto.com/",
"name": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"not_valid_after": "2028-09-18",
"not_valid_before": "2018-09-18",
"pdf_data": {
"_type": "sec_certs.sample.cc_eucc_common.PdfData",
"cert_filename": "1003c_pdf.pdf",
"cert_frontpage": null,
"cert_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-1003-2018": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077-V2-2015": 1
}
},
"cc_sar": {
"ALC": {
"ALC_FLR": 1
},
"AVA": {
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 2": 1,
"EAL 4": 1,
"EAL 4 augmented": 1,
"EAL 5": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"ISO": {
"ISO/IEC 15408": 2,
"ISO/IEC 18045": 2
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"Gemalto": {
"Gemalto": 1
}
},
"vulnerability": {}
},
"cert_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20180920083617+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto\"",
"/ModDate": "D:20180928134141+02\u002700\u0027",
"/Producer": "LibreOffice 5.2",
"/Subject": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"/Title": "Certification Report BSI-DSZ-CC-1003-2018",
"pdf_file_size_bytes": 355322,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 1
},
"report_filename": "1003a_pdf.pdf",
"report_frontpage": {
"DE": {
"cc_security_level": "Gemalto SA Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil f\u00fcr das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen, Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015 PP conformant Common Criteria Part 2 extended Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 SOGIS Recognition Agreement",
"cc_version": "",
"cert_id": "BSI-DSZ-CC-1003-2018",
"cert_item": "on MultiApp V4 Revision A",
"cert_lab": "BSI",
"developer": "## Gemalto SA BSI -",
"match_rules": [
"(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
],
"ref_protection_profiles": ""
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 3
},
"ECDSA": {
"ECDSA": 7
}
},
"FF": {
"DH": {
"DH": 2,
"Diffie-Hellman": 1
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0891-V2-2016": 3,
"BSI-DSZ-CC-1003-2018": 36
},
"FR": {
"ANSSI-CC-2017/54": 3
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077-V2-2015": 2,
"BSI-CC-PP0077-V2-2015": 1,
"BSI-CCPP-0077-V2-2015": 1
}
},
"cc_sar": {
"ADV": {
"ADV_ARC": 1,
"ADV_COMP.1": 1
},
"AGD": {
"AGD_OPE": 2,
"AGD_PRE": 2
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS.1": 1,
"ALC_FLR": 3,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"AVA": {
"AVA_VAN": 1,
"AVA_VAN.5": 4
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 2": 2,
"EAL 2+": 1,
"EAL 4": 5,
"EAL 4 augmented": 3,
"EAL 5": 4,
"EAL 5+": 1,
"EAL 6": 1
}
},
"cc_sfr": {
"FCS": {
"FCS_CKM": 5,
"FCS_COP": 6,
"FCS_RNG.1": 1
},
"FIA": {
"FIA_UAU.4": 1,
"FIA_UAU.5": 1,
"FIA_UID.1": 1
},
"FTP": {
"FTP_ITC.1": 1
}
},
"certification_process": {
"ConfidentialDocument": {
"Application on MultiApp V4 Revision A, Version 3, 10 August 2018, T\u00dcV Informationstechnik GmbH (confidential document": 1,
"Target of Security Module for Smart Meter Gateway, D1359877, Version 2.1, 3 August 2018, Gemalto (confidential document": 1,
"being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1,
"v1.1,Version 1.2, 3 August 2018, and File LIS_SMGWSMV11_CAR_LBL03_1.65.1.7.1.5.1.20, Gemalto (confidential document": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 4
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 7
},
"TLS": {
"TLS": {
"TLS": 4
}
}
},
"crypto_scheme": {
"KA": {
"KA": 1,
"Key Agreement": 7
},
"MAC": {
"MAC": 3
}
},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"Serma": {
"Serma Safety \u0026 Security": 1
},
"TUV": {
"T\u00dcV Informationstechnik": 3
}
},
"hash_function": {
"JH": {
"JH": 1
},
"SHA": {
"SHA2": {
"SHA-2": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RNG": 2
}
},
"side_channel_analysis": {
"FI": {
"malfunction": 1
},
"other": {
"JIL": 5
}
},
"standard_id": {
"BSI": {
"AIS 1": 1,
"AIS 14": 1,
"AIS 19": 1,
"AIS 20": 4,
"AIS 25": 1,
"AIS 26": 3,
"AIS 31": 2,
"AIS 32": 1,
"AIS 34": 2,
"AIS 35": 2,
"AIS 36": 4,
"AIS 37": 1,
"AIS 38": 1,
"AIS 46": 1
},
"FIPS": {
"FIPS 180-4": 2,
"FIPS 186-3": 5,
"FIPS 197": 2,
"FIPS PUB 180-4": 1,
"FIPS PUB 186-3": 1,
"FIPS PUB 197": 1
},
"ISO": {
"ISO/IEC 10116": 2,
"ISO/IEC 15408": 4,
"ISO/IEC 17065": 2,
"ISO/IEC 18045": 4,
"ISO/IEC 7816-4": 1
},
"RFC": {
"RFC 4493": 2,
"RFC 5639": 7
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 7
}
},
"constructions": {
"MAC": {
"CMAC": 5
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7148": 1,
"BSI TR-03109-2": 9,
"BSI TR-03109-3": 2,
"BSI TR-03110-2": 1,
"BSI TR-03110-3": 1,
"BSI TR-03116-3": 2,
"BSI TR-3109-2": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"Gemalto": {
"Gemalto": 27
},
"Infineon": {
"Infineon": 11,
"Infineon Technologies AG": 2
}
},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20180920083559+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto\"",
"/ModDate": "D:20180928133832+02\u002700\u0027",
"/Producer": "LibreOffice 5.2",
"/Subject": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"/Title": "Certification Report BSI-DSZ-CC-1003-2018",
"pdf_file_size_bytes": 899116,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"https://www.bsi.bund.de/",
"http://www.commoncriteriaportal.org/",
"http://www.sogisportal.eu/",
"https://www.bsi.bund.de/zertifizierung",
"https://www.bsi.bund.de/AIS",
"https://www.bsi.bund.de/zertifizierungsreporte",
"http://www.commoncriteriaportal.org/cc/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 32
},
"st_filename": "1003b_pdf.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 10
},
"ECDH": {
"ECDH": 1
},
"ECDSA": {
"ECDSA": 26
}
},
"FF": {
"DH": {
"DH": 16,
"Diffie-Hellman": 3
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0891-V2-2016": 1,
"BSI-DSZ-CC-1003-2017": 1,
"BSI-DSZ-CC-1003-2018": 1
},
"FR": {
"ANSSI-CC-2017/54": 1
},
"NL": {
"CC-1": 5,
"CC-2": 2,
"CC-3": 3
}
},
"cc_claims": {
"A": {
"A.APPLET": 1,
"A.VERIFICATION": 3
},
"O": {
"O.PACE": 1
},
"OE": {
"OE.PACE": 1
},
"OSP": {
"OSP.RND": 3,
"OSP.SM": 1,
"OSP.VERIFICATION": 2
},
"T": {
"T.CONFID-APPLI-DATA": 1,
"T.CONFID-JCS-CODE": 1,
"T.CONFID-JCS-DATA": 2,
"T.EXE-CODE": 6,
"T.INSTALL": 2,
"T.INTEG-APPLI-CODE": 2,
"T.INTEG-APPLI-DATA": 2,
"T.INTEG-JCS-CODE": 3,
"T.INTEG-JCS-DATA": 2,
"T.NATIVE": 3,
"T.OBJ-DELETION": 4,
"T.PHYSICAL": 4,
"T.RESOURCES": 3,
"T.SID": 4
}
},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP- 0084-2014": 1,
"BSI-CC-PP-0073-2014": 1,
"BSI-CC-PP-0077-V2-2015": 3
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_FSP.4": 1,
"ADV_IMP.1": 1,
"ADV_TDS.3": 1
},
"AGD": {
"AGD_OPE": 1,
"AGD_OPE.1": 1,
"AGD_OPE_PLTF": 6,
"AGD_OPE_SMGW": 4,
"AGD_PRE": 1,
"AGD_PRE.1": 1,
"AGD_PRE_PLTF": 4,
"AGD_PRE_SMGW": 2
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS": 2,
"ALC_DVS.1": 1,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_ECD.1": 1,
"ASE_INT.1": 1,
"ASE_OBJ.2": 1,
"ASE_REQ.2": 1,
"ASE_SPD.1": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_DPT.1": 1,
"ATE_FUN.1": 1,
"ATE_IND.2": 1
},
"AVA": {
"AVA_VAN": 2,
"AVA_VAN.5": 12
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 2,
"EAL 5": 1,
"EAL 5 augmented": 1,
"EAL4": 2,
"EAL4 augmented": 1
}
},
"cc_sfr": {
"FCS": {
"FCS_CKM": 29,
"FCS_CKM.1": 16,
"FCS_CKM.2": 4,
"FCS_CKM.4": 23,
"FCS_CKM.4.1": 1,
"FCS_COP": 26,
"FCS_COP.1": 11,
"FCS_RNG": 7,
"FCS_RNG.1": 10,
"FCS_RNG.1.1": 2,
"FCS_RNG.1.2": 2
},
"FDP": {
"FDP_ACC": 1,
"FDP_ACC.1": 6,
"FDP_ACC.2": 7,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 2,
"FDP_ACF.1": 4,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_ETC": 1,
"FDP_ETC.1": 3,
"FDP_ETC.1.1": 1,
"FDP_ETC.1.2": 1,
"FDP_IFC.1": 4,
"FDP_ITC": 1,
"FDP_ITC.1": 13,
"FDP_ITC.1.1": 1,
"FDP_ITC.1.2": 1,
"FDP_ITC.1.3": 1,
"FDP_ITC.2": 7,
"FDP_RIP": 1,
"FDP_RIP.1": 5,
"FDP_RIP.1.1": 1,
"FDP_SDI": 1,
"FDP_SDI.1": 1,
"FDP_SDI.2": 4,
"FDP_SDI.2.1": 2,
"FDP_SDI.2.2": 1,
"FDP_UCT": 1,
"FDP_UCT.1": 3,
"FDP_UCT.1.1": 1,
"FDP_UIT": 1,
"FDP_UIT.1": 3,
"FDP_UIT.1.1": 1,
"FDP_UIT.1.2": 1
},
"FIA": {
"FIA_ATD": 1,
"FIA_ATD.1": 5,
"FIA_ATD.1.1": 1,
"FIA_SOS": 1,
"FIA_SOS.1": 3,
"FIA_SOS.1.1": 1,
"FIA_UAU": 9,
"FIA_UAU.1": 4,
"FIA_UAU.4": 3,
"FIA_UAU.4.1": 1,
"FIA_UAU.5": 3,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UID": 1,
"FIA_UID.1": 9,
"FIA_UID.1.1": 1,
"FIA_UID.1.2": 1,
"FIA_USB": 1,
"FIA_USB.1": 3,
"FIA_USB.1.1": 1,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_LIM": 5,
"FMT_LIM.1": 17,
"FMT_LIM.1.1": 2,
"FMT_LIM.2": 16,
"FMT_LIM.2.1": 2,
"FMT_MSA.3": 2,
"FMT_SMF": 1,
"FMT_SMF.1": 4,
"FMT_SMF.1.1": 1,
"FMT_SMR": 1,
"FMT_SMR.1": 3,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPT": {
"FPT_EMS": 6,
"FPT_EMS.1": 7,
"FPT_EMS.1.1": 3,
"FPT_EMS.1.2": 3,
"FPT_FLS": 1,
"FPT_FLS.1": 4,
"FPT_FLS.1.1": 1,
"FPT_PHP": 1,
"FPT_PHP.3": 3,
"FPT_PHP.3.1": 1,
"FPT_TST": 1,
"FPT_TST.1": 4,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ITC": 1,
"FTP_ITC.1": 7,
"FTP_ITC.1.1": 1,
"FTP_ITC.1.2": 1,
"FTP_ITC.1.3": 1,
"FTP_TRP.1": 2
}
},
"certification_process": {
"OutOfScope": {
"As these external entities do not directly interact with the TOE, these entities are out of scope for this ST": 1,
"out of scope": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 5
}
},
"cplc_data": {
"ICFab": {
"IC Fabricator": 1
},
"ICType": {
"IC Type": 1
}
},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"IKE": {
"IKE": 1
},
"PACE": {
"PACE": 77
},
"TLS": {
"TLS": {
"TLS": 19
}
}
},
"crypto_scheme": {
"KA": {
"Key Agreement": 9
},
"KEX": {
"Key Exchange": 1
},
"MAC": {
"MAC": 1
}
},
"device_model": {},
"ecc_curve": {
"Brainpool": {
"brainpoolP256r1": 1,
"brainpoolP384r1": 1,
"brainpoolP512r1": 1
},
"NIST": {
"NIST P-256": 1,
"NIST P-384": 1,
"P-256": 1,
"P-384": 1,
"secp256r1": 1,
"secp384r1": 1
}
},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RND": 5,
"RNG": 10
}
},
"side_channel_analysis": {
"FI": {
"DFA": 1,
"Malfunction": 14,
"Physical Tampering": 2,
"fault injection": 1,
"malfunction": 4,
"physical tampering": 4
},
"SCA": {
"DPA": 7,
"SPA": 2,
"physical probing": 4,
"side channel": 1,
"side channels": 1,
"timing attacks": 2
}
},
"standard_id": {
"BSI": {
"AIS 20": 1,
"AIS 31": 2,
"AIS 36": 1,
"AIS31": 1,
"AIS36": 1
},
"CC": {
"CCMB-2012-09-001": 1,
"CCMB-2012-09-002": 1,
"CCMB-2012-09-003": 1
},
"FIPS": {
"FIPS 197": 1,
"FIPS PUB 186-3": 1,
"FIPS PUB 46-3": 1,
"FIPS180-4": 1,
"FIPS186": 3,
"FIPS197": 2,
"FIPS46-3": 1
},
"ISO": {
"ISO/IEC 10116": 2
},
"PKCS": {
"PKCS#3": 1
},
"RFC": {
"RFC 2409": 2,
"RFC 4493": 2,
"RFC 4993": 1,
"RFC 5639": 1,
"RFC5639": 4
},
"X509": {
"X.509": 2
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 10
}
},
"DES": {
"DES": {
"DES": 1
}
},
"constructions": {
"MAC": {
"CMAC": 2
}
}
},
"technical_report_id": {
"BSI": {
"BSI TR-03109-3": 1,
"BSI TR-03110-1": 1,
"BSI TR-03110-2": 1,
"BSI TR-03110-3": 1,
"BSI TR-03116-3": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"Gemalto": {
"Gemalto": 496
},
"Infineon": {
"Infineon": 6
}
},
"vulnerability": {}
},
"st_metadata": {
"/Author": "F.GUERIN",
"/CreationDate": "D:20180803120200+02\u002700\u0027",
"/Creator": "Microsoft\u00ae Word 2013",
"/Keywords": "Security Target, CC, Smart Meter",
"/ModDate": "D:20180803120200+02\u002700\u0027",
"/Producer": "Microsoft\u00ae Word 2013",
"/Subject": "SM for Smart Meter (Public Version)",
"/Title": "Security Target of Security Module for Smart Meter Gateway (PUBLIC version) BSI-DSZ-CC-1003-2017 TOE NAME: Smart Meter Gateway SM applet on MultiApp V4",
"pdf_file_size_bytes": 2286486,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"http://csrc.nist.gov/publications/fips/fips180-4/fips-180-4.pdf",
"http://www.sogisportal.eu/documents/cc/common/JIL-Collection-of-Developer-Evidence-v1-5.pdf"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 79
}
},
"protection_profile_links": {
"_type": "Set",
"elements": [
"https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0077V2b_pdf.pdf"
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"AVA_VAN.5",
"EAL4"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003b_pdf.pdf",
"state": {
"_type": "sec_certs.sample.cc_eucc_common.InternalState",
"cert": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": "e645f3043e589fb287099ee3e20357f69fe4a0bf73589b397976ce63b7070449",
"source_hash": "bd54eb702e1947dac6a3ec5a67e202a9796ee8c7656efb7a4d797acd924a4256",
"txt_hash": "c98bd63306614a21de4502dbb30eabebea4f07b64042c6f55d17001737d5f892"
},
"report": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": "514de9b876fa85f4dc7f0437ba77ebd881845829253bcac7654a358f578c941c",
"source_hash": "816b42d78af6250abeae0a03ea39a6e129c268fe4a44e7ae17f3eaa4fce68ce4",
"txt_hash": "9a7dc5a7d7ee2a35b0e596b60cc59c897520d7b4d389866008ed1d3807618fc0"
},
"st": {
"_type": "sec_certs.sample.document_state.DocumentState",
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"json_hash": "e848b25557ce734735adee9f846c85fcba278ec54d2de888b935d38091e2c6a3",
"source_hash": "cf320913a582afd299839285636da64608d093a6d96e2ef6d72988533fd0443e",
"txt_hash": "a0a54c6e2e64d5578ce35d47fa90309f4f1b1745f9c7a90faf97aa200837e32a"
}
},
"status": "active"
}