TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA

CSV information ?

Status active
Valid from 09.02.2015
Valid until 10.02.2025
Scheme 🇩🇪 DE
Manufacturer T-Systems International GMBH
Category ICs, Smart Cards and Smart Card-Related Devices and Systems
Security level EAL4+, AVA_VAN.5

Heuristics summary ?

Certificate ID: BSI-DSZ-CC-0957-2015

Certificate ?

Certification report ?

Extracted keywords

Symmetric Algorithms
AES, CMAC
Asymmetric Algorithms
ECDSA, ECC, DH, Diffie-Hellman
Schemes
MAC, Key Agreement, KA
Protocols
TLS, PACE
Randomness
RNG
Engines
SmartMX2
Block cipher modes
CBC

Vendor
NXP, NXP Semiconductors

Security level
EAL 4, EAL 5, EAL 1, EAL 2, EAL 5+, EAL 6, EAL 3, EAL 7, EAL 4 augmented, ITSEC Evaluation
Security Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.1, ADV_FSP.2, ADV_FSP.3, ADV_FSP.4, ADV_FSP.5, ADV_FSP.6, ADV_IMP.1, ADV_IMP.2, ADV_INT.1, ADV_INT.2, ADV_INT.3, ADV_SPM.1, ADV_TDS.1, ADV_TDS.2, ADV_TDS.3, ADV_TDS.4, ADV_TDS.5, ADV_TDS.6, ADV_ARC, ADV_FSP, ADV_IMP, ADV_INT, ADV_SPM, ADV_TDS, AGD_OPE.1, AGD_PRE.1, AGD_OPE, AGD_PRE, ALC_FLR, ALC_CMC.1, ALC_CMC.2, ALC_CMC.3, ALC_CMC.4, ALC_CMC.5, ALC_CMS.1, ALC_CMS.2, ALC_CMS.3, ALC_CMS.4, ALC_CMS.5, ALC_DEL.1, ALC_DVS.1, ALC_DVS.2, ALC_FLR.1, ALC_FLR.2, ALC_FLR.3, ALC_LCD.1, ALC_LCD.2, ALC_TAT.1, ALC_TAT.2, ALC_TAT.3, ALC_CMC, ALC_CMS, ALC_DEL, ALC_DVS, ALC_TAT, ATE_COV.1, ATE_COV.2, ATE_COV.3, ATE_DPT.1, ATE_DPT.2, ATE_DPT.3, ATE_DPT.4, ATE_FUN.1, ATE_FUN.2, ATE_IND.1, ATE_IND.2, ATE_IND.3, ATE_COV, ATE_DPT, ATE_FUN, ATE_IND, AVA_VAN.5, AVA_VAN.1, AVA_VAN.2, AVA_VAN.3, AVA_VAN.4, AVA_VAN, APE_INT.1, APE_CCL.1, APE_SPD.1, APE_OBJ.1, APE_OBJ.2, APE_ECD.1, APE_REQ.1, APE_REQ.2, ASE_INT.1, ASE_CCL.1, ASE_SPD.1, ASE_OBJ.1, ASE_OBJ.2, ASE_ECD.1, ASE_REQ.1, ASE_REQ.2, ASE_TSS.1, ASE_TSS.2, ASE_CCL, ASE_ECD, ASE_INT, ASE_OBJ, ASE_SPD, ASE_TSS
Security Functional Requirements (SFR)
FCS_COP, FCS_CKM, FCS_RNG.1, FIA_UID.1, FIA_UAU.4, FIA_UAU.5, FTP_ITC.1
Protection profiles
BSI-CC-PP-0077-V2-2015
Certificates
BSI-DSZ-CC-0957-2015, BSI-DSZ-CC-0845-V2-2013, BSI-DSZ-CC-00845-V2-2013
Evaluation facilities
SRC Security Research & Consulting, T-Systems International

Side-channel analysis
side channel, malfunction, fault injection, JIL
Certification process
and certification procedure is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the product or resulting from the evaluation and certification, 1.0 Release 1/P60C144PVA, Version 1.0, 9 February 2015, SRC Security Research & Consulting GmbH (confidential document) [9] Configuration List BSI-DSZ-CC-0957-2015, Konfigurationsliste von TCOS Smart Meter Security, Version 1.0 Release 1/P60C144PVA, Version 1.1, 6 February 2015, T-Systems International GmbH (confidential document) 9 specifically • AIS 1, Version 13, Durchführung der Ortsbesichtigung in der Entwicklungsumgebung

Standards
FIPS 180-2, FIPS 186, FIPS 197, AIS 34, AIS 36, AIS 26, AIS 25, AIS 20, AIS 1, AIS 31, AIS 32, AIS 46, AIS36, RFC 5639, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065
Technical reports
BSI TR-03109-2, BSI 7138, BSI 7125, BSI 7148

File metadata

Title Certification Report BSI-DSZ-CC-0957-2015
Subject Common Criteria Zertifizierung
Keywords "Common Criteria, Certification, Zertifizierung, Smart Meter Security Module"
Author Bundesamt für Sicherheit in der Informationstechnik
Creation date D:20150212092005+01'00'
Modification date D:20150212110928+01'00'
Pages 38
Creator Writer
Producer LibreOffice 4.2

Frontpage

Certificate ID BSI-DSZ-CC-0957-2015
Certified item TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA
Certification lab BSI
Developer T-Systems International GmbH

References

Outgoing
  • BSI-DSZ-CC-0845-V2-2013 - archived - NXP Secure Smart Card Controller P60x144/080PVA/PVA(Y) with IC Dedicated Software FW5.0
Incoming

Security target ?

Extracted keywords

Symmetric Algorithms
AES, DES, Triple-DES, TDES, CMAC
Asymmetric Algorithms
ECDH, ECDSA, ECC, DH, Diffie-Hellman
Schemes
MAC, Key Agreement
Protocols
TLS, PACE
Randomness
RND, RNG
Elliptic Curves
P-256, P-384, NIST P-256, NIST P-384, secp256r1, secp384r1, brainpoolP256r1, brainpoolP384r1, brainpoolP512r1
Block cipher modes
CBC

Vendor
NXP, NXP Semiconductors

Security level
EAL4, EAL 6+, EAL 4, EAL 6, EAL4 augmented, EAL 6 augmented
Claims
O.PACE, O.RND, O.HW_AES, O.MEM_ACCESS, O.SFR_ACCESS, O.FW_HW, T.RND, OE.PACE, OSP.SM
Security Assurance Requirements (SAR)
ADV_TDS, ADV_ARC, ADV_FSP, ADV_IMP.1, ADV_ARC.1, ADV_FSP.4, ADV_TDS.3, AGD_PRE.1, AGD_OPE.1, ALC_FLR.1, ALC_DEL.1, ALC_CMC.4, ALC_CMS.4, ALC_LCD.1, ALC_TAT.1, ALC_DVS.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, AVA_VAN.5, ASE_TSS.2
Security Functional Requirements (SFR)
FAU_SAS.1, FCS_RNG, FCS_RNG.1, FCS_RNG.1.1, FCS_RNG.1.2, FCS_CKM, FCS_CKM.4, FCS_COP, FCS_CKM.1, FCS_CKM.2, FCS_COP.1, FCS_CKM.4.1, FDP_ACF, FDP_ACC.2, FDP_ACF.1, FDP_SDI.2, FDP_RIP.1, FDP_ETC.1, FDP_ITC.1, FDP_UCT.1, FDP_UIT.1, FDP_ITC.2, FDP_ACC.1, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_SDI.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_RIP.1.1, FDP_IFC, FDP_ETC.1.1, FDP_ETC.1.2, FDP_IFC.1, FDP_ITC.1.1, FDP_ITC.1.2, FDP_ITC.1.3, FDP_UIT.1.1, FDP_UIT.1.2, FDP_ITC, FDP_SDI, FDP_RIP, FDP_UIT, FDP_ITT.1, FIA_ATD.1, FIA_SOS.1, FIA_UAU, FIA_UAU.4, FIA_UAU.5, FIA_UID.1, FIA_USB.1, FIA_ATD.1.1, FIA_SOS.1.1, FIA_UAU.1, FIA_UAU.4.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UID.1.1, FIA_UID.1.2, FIA_USB.1.1, FIA_USB.1.2, FIA_USB.1.3, FIA_SOS, FIA_UID, FIA_USB, FMT_LIM, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA.3, FMT_SMF.1.1, FMT_SMR.1.1, FMT_SMR.1.2, FMT_SMR, FMT_MSA.1, FPT_EMS, FPT_EMS.1, FPT_EMS.1.1, FPT_EMS.1.2, FPT_FLS.1, FPT_PHP.3, FPT_TST.1, FPT_FLS.1.1, FPT_PHP.3.1, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FPT_FLS, FPT_PHP, FPT_TST, FPT_ITT.1, FRU_FLT.2, FTP_ITC.1, FTP_TRP.1, FTP_ITC.1.1, FTP_ITC.1.2, FTP_ITC.1.3, FTP_ICT.1, FTP_ITC
Protection profiles
BSI-CC-PP-0077-V2-2015, BSI-CC-PP-0035-2007, BSI-CC-PP-0073-2014
Certificates
BSI-DSZ-CC-0957
Evaluation facilities
T-Systems International

Side-channel analysis
Leak-Inherent, Physical Probing, physical probing, side channels, side channel, side-channels, SPA, DPA, timing attacks, Physical tampering, physical tampering, Malfunction, malfunction, DFA, fault injection
Certification process
out of scope, entities. 72 As these external entities only indirectly interact with the TOE, these entities are out of scope for this ST. 73 During its pre-operational phases the TOE interacts with the Integrator and the

Standards
FIPS186, FIPS197, FIPS PUB 186-3, AIS36, AIS 36, RFC5639, RFC 5639, ISO/IEC 7810:2003, X.509, CCMB-2012-09-001, CCMB-2012-09-002, CCMB-2012-09-003, CCMB-2012-09-004
Technical reports
BSI TR-03109

File metadata

Title Security Target TCOS Smart Meter Security Module (NXP)
Subject TCOS Smart Meter Security Module Version 1.0 Release 1
Keywords TCOS Security Module, Sicherheitsmodul, Smart Meter
Author T-Systems International GmbH
Creation date D:20150209010001
Modification date D:20150209135248+01'00'
Pages 75
Creator PScript5.dll Version 5.2.2
Producer TeleSec ps2pdf

Heuristics ?

Certificate ID: BSI-DSZ-CC-0957-2015

Extracted SARs

ASE_CCL.1, ALC_DEL.1, ALC_CMC.4, ATE_DPT.1, AVA_VAN.5, ATE_FUN.1, ADV_ARC.1, ADV_TDS.3, ASE_SPD.1, ASE_REQ.2, ALC_CMS.4, ADV_IMP.1, ALC_TAT.1, ASE_TSS.2, ATE_COV.2, APE_INT.1, AGD_OPE.1, ALC_DVS.1, APE_CCL.1, APE_REQ.2, ATE_IND.3, APE_ECD.1, ASE_ECD.1, ADV_INT.3, ADV_SPM.1, ADV_FSP.4, ASE_INT.1, APE_OBJ.2, AGD_PRE.1, APE_SPD.1, ALC_LCD.1, ALC_FLR.1, ASE_OBJ.2

Scheme data ?

Cert Id BSI-DSZ-CC-1035-2017
Product TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE
Vendor T-Systems International GmbH
Certification Date 06.10.2017
Category Intelligent measuring systems
Url https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_MiniHSM/1035.html
Enhanced
Product TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE
Applicant T-Systems International GmbH Untere Industriestraße 20 57250 Netphen
Evaluation Facility SRC Security Research & Consulting GmbH
Assurance Level EAL4+,AVA_VAN.5
Certification Date 06.10.2017
Expiration Date 05.10.2027
Report Link https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035a_pdf.pdf?__blob=publicationFile&v=1
Target Link https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035b_pdf.pdf?__blob=publicationFile&v=1
Description The Target of Evaluation (TOE) is the product TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE developed by T-Systems International GmbH. The TOE is a Security Module according to the Technical Guideline BSI TR-03109-2 Annex B, Version 1.0 and is intended to be integrated in a so-called Smart Meter Mini-HSM. The TOE serves as a cryptographic service provider and supports different parties (as e.g. the Gateway Administrator) for their specific cryptographic needs in the framework of Smart Metering Systems. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further sensitive data relevant for the user.
Subcategory Security module for an Smart Meter Mini-HSM

References ?

Updates ?

  • 09.11.2024 The certificate data changed.
    Certificate changed

    The computed heuristics were updated.

    • The report_references property was updated, with the {'indirectly_referenced_by': {'__add__': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0831-V8-2024', 'BSI-DSZ-CC-0831-V9-2024']}}} data.
    • The scheme_data property was set to {'cert_id': 'BSI-DSZ-CC-1035-2017', 'product': 'TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE', 'vendor': 'T-Systems International GmbH', 'certification_date': '2017-10-06', 'category': 'Intelligent measuring systems', 'url': 'https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_MiniHSM/1035.html', 'enhanced': {'product': 'TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE', 'applicant': 'T-Systems International GmbH Untere Industriestraße 20 57250 Netphen', 'evaluation_facility': 'SRC Security Research & Consulting GmbH', 'assurance_level': 'EAL4+,AVA_VAN.5', 'certification_date': '2017-10-06', 'expiration_date': '2027-10-05', 'report_link': 'https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035a_pdf.pdf?__blob=publicationFile&v=1', 'target_link': 'https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035b_pdf.pdf?__blob=publicationFile&v=1', 'description': 'The Target of Evaluation (TOE) is the product TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE developed by T-Systems International GmbH. The TOE is a Security Module according to the Technical Guideline BSI TR-03109-2 Annex B, Version 1.0 and is intended to be integrated in a so-called Smart Meter Mini-HSM. The TOE serves as a cryptographic service provider and supports different parties (as e.g. the Gateway Administrator) for their specific cryptographic needs in the framework of Smart Metering Systems. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further sensitive data relevant for the user.'}, 'subcategory': 'Security module for an Smart Meter Mini-HSM'}.
  • 22.08.2024 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The st property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'cb5120b6071479f829d11b4ee58151704004478cab408bec581a673cfb5275a8', 'txt_hash': '112a724c5dc3fcff2799c05109e515d6ffb54da328d412ea3aabdcaf44402a73'} data.

    The PDF extraction data was updated.

    • The st_metadata property was set to {'pdf_file_size_bytes': 631545, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 75, '/Producer': 'TeleSec ps2pdf', '/CreationDate': 'D:20150209010001', '/ModDate': "D:20150209135248+01'00'", '/Title': 'Security Target TCOS Smart Meter Security Module (NXP)', '/Creator': 'PScript5.dll Version 5.2.2', '/Author': 'T-Systems International GmbH', '/Subject': 'TCOS Smart Meter Security Module Version 1.0 Release 1', '/Keywords': 'TCOS Security Module, Sicherheitsmodul, Smart Meter', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}.
    • The st_keywords property was set to {'cc_cert_id': {'DE': {'BSI-DSZ-CC-0957': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0077-V2-2015': 2, 'BSI-CC-PP-0035-2007': 1, 'BSI-CC-PP-0073-2014': 1}}, 'cc_security_level': {'EAL': {'EAL4': 4, 'EAL 6+': 1, 'EAL 4': 5, 'EAL 6': 1, 'EAL4 augmented': 3, 'EAL 6 augmented': 1}}, 'cc_sar': {'ADV': {'ADV_TDS': 2, 'ADV_ARC': 1, 'ADV_FSP': 1, 'ADV_IMP.1': 3, 'ADV_ARC.1': 1, 'ADV_FSP.4': 1, 'ADV_TDS.3': 1}, 'AGD': {'AGD_PRE.1': 3, 'AGD_OPE.1': 1}, 'ALC': {'ALC_FLR.1': 2, 'ALC_DEL.1': 3, 'ALC_CMC.4': 1, 'ALC_CMS.4': 1, 'ALC_LCD.1': 1, 'ALC_TAT.1': 1, 'ALC_DVS.1': 1}, 'ATE': {'ATE_COV.2': 1, 'ATE_DPT.1': 1, 'ATE_FUN.1': 1}, 'AVA': {'AVA_VAN.5': 10}, 'ASE': {'ASE_TSS.2': 2}}, 'cc_sfr': {'FAU': {'FAU_SAS.1': 1}, 'FCS': {'FCS_RNG': 6, 'FCS_RNG.1': 20, 'FCS_RNG.1.1': 2, 'FCS_RNG.1.2': 2, 'FCS_CKM': 49, 'FCS_CKM.4': 45, 'FCS_COP': 59, 'FCS_CKM.1': 16, 'FCS_CKM.2': 8, 'FCS_COP.1': 17, 'FCS_CKM.4.1': 1}, 'FDP': {'FDP_ACF': 2, 'FDP_ACC.2': 17, 'FDP_ACF.1': 9, 'FDP_SDI.2': 7, 'FDP_RIP.1': 7, 'FDP_ETC.1': 7, 'FDP_ITC.1': 20, 'FDP_UCT.1': 8, 'FDP_UIT.1': 7, 'FDP_ITC.2': 14, 'FDP_ACC.1': 13, 'FDP_ACC.2.1': 1, 'FDP_ACC.2.2': 1, 'FDP_ACF.1.1': 1, 'FDP_ACF.1.2': 1, 'FDP_ACF.1.3': 1, 'FDP_ACF.1.4': 1, 'FDP_SDI.1': 1, 'FDP_SDI.2.1': 1, 'FDP_SDI.2.2': 1, 'FDP_RIP.1.1': 1, 'FDP_IFC': 1, 'FDP_ETC.1.1': 1, 'FDP_ETC.1.2': 1, 'FDP_IFC.1': 8, 'FDP_ITC.1.1': 1, 'FDP_ITC.1.2': 1, 'FDP_ITC.1.3': 1, 'FDP_UIT.1.1': 1, 'FDP_UIT.1.2': 1, 'FDP_ITC': 8, 'FDP_SDI': 1, 'FDP_RIP': 1, 'FDP_UIT': 1, 'FDP_ITT.1': 1}, 'FIA': {'FIA_ATD.1': 10, 'FIA_SOS.1': 3, 'FIA_UAU': 18, 'FIA_UAU.4': 6, 'FIA_UAU.5': 6, 'FIA_UID.1': 14, 'FIA_USB.1': 6, 'FIA_ATD.1.1': 1, 'FIA_SOS.1.1': 1, 'FIA_UAU.1': 5, 'FIA_UAU.4.1': 1, 'FIA_UAU.5.1': 1, 'FIA_UAU.5.2': 1, 'FIA_UID.1.1': 1, 'FIA_UID.1.2': 1, 'FIA_USB.1.1': 1, 'FIA_USB.1.2': 1, 'FIA_USB.1.3': 1, 'FIA_SOS': 1, 'FIA_UID': 1, 'FIA_USB': 1}, 'FMT': {'FMT_LIM': 6, 'FMT_LIM.1': 25, 'FMT_LIM.2': 23, 'FMT_LIM.1.1': 2, 'FMT_LIM.2.1': 2, 'FMT_SMF.1': 10, 'FMT_SMR.1': 6, 'FMT_MSA.3': 6, 'FMT_SMF.1.1': 1, 'FMT_SMR.1.1': 1, 'FMT_SMR.1.2': 1, 'FMT_SMR': 1, 'FMT_MSA.1': 2}, 'FPT': {'FPT_EMS': 6, 'FPT_EMS.1': 15, 'FPT_EMS.1.1': 2, 'FPT_EMS.1.2': 2, 'FPT_FLS.1': 11, 'FPT_PHP.3': 10, 'FPT_TST.1': 7, 'FPT_FLS.1.1': 1, 'FPT_PHP.3.1': 1, 'FPT_TST.1.1': 1, 'FPT_TST.1.2': 1, 'FPT_TST.1.3': 1, 'FPT_FLS': 1, 'FPT_PHP': 1, 'FPT_TST': 1, 'FPT_ITT.1': 1}, 'FRU': {'FRU_FLT.2': 1}, 'FTP': {'FTP_ITC.1': 10, 'FTP_TRP.1': 4, 'FTP_ITC.1.1': 1, 'FTP_ITC.1.2': 1, 'FTP_ITC.1.3': 1, 'FTP_ICT.1': 4, 'FTP_ITC': 1}}, 'cc_claims': {'O': {'O.PACE': 5, 'O.RND': 3, 'O.HW_AES': 4, 'O.MEM_ACCESS': 3, 'O.SFR_ACCESS': 3, 'O.FW_HW': 1}, 'T': {'T.RND': 1}, 'OE': {'OE.PACE': 1}, 'OSP': {'OSP.SM': 1}}, 'vendor': {'NXP': {'NXP': 2, 'NXP Semiconductors': 1}}, 'eval_facility': {'TSystems': {'T-Systems International': 78}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 16}}, 'DES': {'DES': {'DES': 4}, '3DES': {'Triple-DES': 2, 'TDES': 3}}, 'constructions': {'MAC': {'CMAC': 4}}}, 'asymmetric_crypto': {'ECC': {'ECDH': {'ECDH': 1}, 'ECDSA': {'ECDSA': 19}, 'ECC': {'ECC': 11}}, 'FF': {'DH': {'DH': 13, 'Diffie-Hellman': 5}}}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {'MAC': {'MAC': 2}, 'KA': {'Key Agreement': 17}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 28}}, 'PACE': {'PACE': 66}}, 'randomness': {'RNG': {'RND': 4, 'RNG': 8}}, 'cipher_mode': {'CBC': {'CBC': 4}}, 'ecc_curve': {'NIST': {'P-256': 13, 'P-384': 15, 'NIST P-256': 1, 'NIST P-384': 1, 'secp256r1': 1, 'secp384r1': 1}, 'Brainpool': {'brainpoolP256r1': 2, 'brainpoolP384r1': 2, 'brainpoolP512r1': 2}}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'SCA': {'Leak-Inherent': 4, 'Physical Probing': 2, 'physical probing': 2, 'side channels': 1, 'side channel': 1, 'side-channels': 1, 'SPA': 2, 'DPA': 2, 'timing attacks': 1}, 'FI': {'Physical tampering': 1, 'physical tampering': 5, 'Malfunction': 12, 'malfunction': 3, 'DFA': 1, 'fault injection': 1}}, 'technical_report_id': {'BSI': {'BSI TR-03109': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS186': 10, 'FIPS197': 3, 'FIPS PUB 186-3': 1}, 'BSI': {'AIS36': 3, 'AIS 36': 1}, 'RFC': {'RFC5639': 11, 'RFC 5639': 1}, 'ISO': {'ISO/IEC 7810:2003': 1}, 'X509': {'X.509': 2}, 'CC': {'CCMB-2012-09-001': 1, 'CCMB-2012-09-002': 1, 'CCMB-2012-09-003': 2, 'CCMB-2012-09-004': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'OutOfScope': {'out of scope': 1, 'entities. 72 As these external entities only indirectly interact with the TOE, these entities are out of scope for this ST. 73 During its pre-operational phases the TOE interacts with the Integrator and the': 1}}}.
    • The st_filename property was set to 0957b_pdf.pdf.

    The computed heuristics were updated.

    • The report_references property was updated, with the {'indirectly_referenced_by': {'__add__': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0831-V6-2023', 'BSI-DSZ-CC-0919-V3-2023', 'BSI-DSZ-CC-0918-V5-2023', 'BSI-DSZ-CC-1035-2017', 'BSI-DSZ-CC-0831-V2-2020', 'BSI-DSZ-CC-0831-V3-2021', 'BSI-DSZ-CC-0831-V5-2022', 'BSI-DSZ-CC-0918-V4-2022', 'BSI-DSZ-CC-0919-V2-2021', 'BSI-DSZ-CC-0831-V7-2023', 'BSI-DSZ-CC-0831-V4-2021', 'BSI-DSZ-CC-0918-V6-2024']}}, 'directly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0845-V2-2013']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0666-2012', 'BSI-DSZ-CC-0845-2012', 'BSI-DSZ-CC-0845-V2-2013']}} data.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DVS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_FLR', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 4}]} values added.
  • 19.08.2024 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The report property was updated, with the {'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'ea00160fcee4f78538be1c86549e6382c013030bb017992b97e52bd704a9ef00', 'txt_hash': '94fabf42b757720ecc5075548e90b46379477647d421144f719ebd1e9c78bf3d'} data.

    The PDF extraction data was updated.

    • The report_metadata property was set to {'pdf_file_size_bytes': 1269846, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 38, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20150212092005+01'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, Smart Meter Security Module"', '/ModDate': "D:20150212110928+01'00'", '/Producer': 'LibreOffice 4.2', '/Subject': 'Common Criteria Zertifizierung', '/Title': 'Certification Report BSI-DSZ-CC-0957-2015', 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['https://www.bsi.bund.de/zertifizierung', 'http://www.commoncriteriaportal.org/', 'https://www.bsi.bund.de/']}}.
    • The report_frontpage property was set to {'DE': {'match_rules': ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)'], 'cert_id': 'BSI-DSZ-CC-0957-2015', 'cert_item': 'TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA', 'developer': 'T-Systems International GmbH', 'cert_lab': 'BSI', 'ref_protection_profiles': 'Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015', 'cc_version': 'PP conformant Common Criteria Part 2 extended', 'cc_security_level': 'Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 Valid until (*): 9 February 2025 SOGIS Recognition Agreement'}}.
    • The report_keywords property was set to {'cc_cert_id': {'DE': {'BSI-DSZ-CC-0957-2015': 24, 'BSI-DSZ-CC-0845-V2-2013': 4, 'BSI-DSZ-CC-00845-V2-2013': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0077-V2-2015': 4}}, 'cc_security_level': {'EAL': {'EAL 4': 13, 'EAL 5': 10, 'EAL 1': 7, 'EAL 2': 4, 'EAL 5+': 1, 'EAL 6': 4, 'EAL 3': 4, 'EAL 7': 4, 'EAL 4 augmented': 3}, 'ITSEC': {'ITSEC Evaluation': 1}}, 'cc_sar': {'ADV': {'ADV_ARC.1': 1, 'ADV_FSP.1': 1, 'ADV_FSP.2': 1, 'ADV_FSP.3': 1, 'ADV_FSP.4': 1, 'ADV_FSP.5': 1, 'ADV_FSP.6': 1, 'ADV_IMP.1': 1, 'ADV_IMP.2': 1, 'ADV_INT.1': 1, 'ADV_INT.2': 1, 'ADV_INT.3': 1, 'ADV_SPM.1': 1, 'ADV_TDS.1': 1, 'ADV_TDS.2': 1, 'ADV_TDS.3': 1, 'ADV_TDS.4': 1, 'ADV_TDS.5': 1, 'ADV_TDS.6': 1, 'ADV_ARC': 1, 'ADV_FSP': 1, 'ADV_IMP': 1, 'ADV_INT': 1, 'ADV_SPM': 1, 'ADV_TDS': 1}, 'AGD': {'AGD_OPE.1': 1, 'AGD_PRE.1': 1, 'AGD_OPE': 1, 'AGD_PRE': 1}, 'ALC': {'ALC_FLR': 3, 'ALC_CMC.1': 1, 'ALC_CMC.2': 1, 'ALC_CMC.3': 1, 'ALC_CMC.4': 2, 'ALC_CMC.5': 1, 'ALC_CMS.1': 1, 'ALC_CMS.2': 1, 'ALC_CMS.3': 1, 'ALC_CMS.4': 2, 'ALC_CMS.5': 1, 'ALC_DEL.1': 2, 'ALC_DVS.1': 2, 'ALC_DVS.2': 1, 'ALC_FLR.1': 1, 'ALC_FLR.2': 1, 'ALC_FLR.3': 1, 'ALC_LCD.1': 2, 'ALC_LCD.2': 1, 'ALC_TAT.1': 2, 'ALC_TAT.2': 1, 'ALC_TAT.3': 1, 'ALC_CMC': 1, 'ALC_CMS': 1, 'ALC_DEL': 1, 'ALC_DVS': 1, 'ALC_TAT': 1}, 'ATE': {'ATE_COV.1': 1, 'ATE_COV.2': 1, 'ATE_COV.3': 1, 'ATE_DPT.1': 1, 'ATE_DPT.2': 1, 'ATE_DPT.3': 1, 'ATE_DPT.4': 1, 'ATE_FUN.1': 1, 'ATE_FUN.2': 1, 'ATE_IND.1': 1, 'ATE_IND.2': 1, 'ATE_IND.3': 1, 'ATE_COV': 1, 'ATE_DPT': 1, 'ATE_FUN': 1, 'ATE_IND': 1}, 'AVA': {'AVA_VAN.5': 6, 'AVA_VAN.1': 1, 'AVA_VAN.2': 1, 'AVA_VAN.3': 1, 'AVA_VAN.4': 1, 'AVA_VAN': 2}, 'APE': {'APE_INT.1': 1, 'APE_CCL.1': 1, 'APE_SPD.1': 1, 'APE_OBJ.1': 1, 'APE_OBJ.2': 1, 'APE_ECD.1': 1, 'APE_REQ.1': 1, 'APE_REQ.2': 1}, 'ASE': {'ASE_INT.1': 1, 'ASE_CCL.1': 1, 'ASE_SPD.1': 1, 'ASE_OBJ.1': 1, 'ASE_OBJ.2': 1, 'ASE_ECD.1': 1, 'ASE_REQ.1': 1, 'ASE_REQ.2': 1, 'ASE_TSS.1': 1, 'ASE_TSS.2': 1, 'ASE_CCL': 1, 'ASE_ECD': 1, 'ASE_INT': 1, 'ASE_OBJ': 1, 'ASE_SPD': 1, 'ASE_TSS': 1}}, 'cc_sfr': {'FCS': {'FCS_COP': 6, 'FCS_CKM': 4, 'FCS_RNG.1': 1}, 'FIA': {'FIA_UID.1': 1, 'FIA_UAU.4': 1, 'FIA_UAU.5': 1}, 'FTP': {'FTP_ITC.1': 1}}, 'cc_claims': {}, 'vendor': {'NXP': {'NXP': 11, 'NXP Semiconductors': 4}}, 'eval_facility': {'SRC': {'SRC Security Research & Consulting': 3}, 'TSystems': {'T-Systems International': 13}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 6}}, 'constructions': {'MAC': {'CMAC': 3}}}, 'asymmetric_crypto': {'ECC': {'ECDSA': {'ECDSA': 6}, 'ECC': {'ECC': 3}}, 'FF': {'DH': {'DH': 2, 'Diffie-Hellman': 2}}}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {'MAC': {'MAC': 3}, 'KA': {'Key Agreement': 8, 'KA': 1}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 6}}, 'PACE': {'PACE': 7}}, 'randomness': {'RNG': {'RNG': 2}}, 'cipher_mode': {'CBC': {'CBC': 3}}, 'ecc_curve': {}, 'crypto_engine': {'SmartMX': {'SmartMX2': 2}}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'SCA': {'side channel': 2}, 'FI': {'malfunction': 1, 'fault injection': 2}, 'other': {'JIL': 2}}, 'technical_report_id': {'BSI': {'BSI TR-03109-2': 1, 'BSI 7138': 2, 'BSI 7125': 2, 'BSI 7148': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS 180-2': 2, 'FIPS 186': 5, 'FIPS 197': 2}, 'BSI': {'AIS 34': 2, 'AIS 36': 4, 'AIS 26': 3, 'AIS 25': 1, 'AIS 20': 3, 'AIS 1': 1, 'AIS 31': 1, 'AIS 32': 1, 'AIS 46': 1, 'AIS36': 1}, 'RFC': {'RFC 5639': 5}, 'ISO': {'ISO/IEC 15408': 4, 'ISO/IEC 18045': 4, 'ISO/IEC 17065': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'ConfidentialDocument': {'and certification procedure is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the product or resulting from the evaluation and certification': 1, '1.0 Release 1/P60C144PVA, Version 1.0, 9 February 2015, SRC Security Research & Consulting GmbH (confidential document) [9] Configuration List BSI-DSZ-CC-0957-2015, Konfigurationsliste von TCOS Smart Meter Security': 1, 'Version 1.0 Release 1/P60C144PVA, Version 1.1, 6 February 2015, T-Systems International GmbH (confidential document) 9 specifically • AIS 1, Version 13, Durchführung der Ortsbesichtigung in der Entwicklungsumgebung': 1}}}.
    • The report_filename property was set to 0957a_pdf.pdf.

    The computed heuristics were updated.

    • The cert_lab property was set to ['BSI'].
    • The cert_id property was set to BSI-DSZ-CC-0957-2015.
    • The report_references property was updated, with the {'directly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0957-V2-2016']}, 'indirectly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0957-V2-2016']}} data.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 5}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DVS', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 5}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 6}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_FLR', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_IND', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_INT', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_SPM', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 6}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_PRE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}]} values added.
  • 17.08.2024 The certificate data changed.
    Certificate changed

    The report_link was updated.

    • The new value is https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957a_pdf.pdf.

    The st_link was updated.

    • The new value is https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957b_pdf.pdf.
  • 12.08.2024 The certificate data changed.
    Certificate changed

    The state of the certificate object was updated.

    • The report property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.
    • The st property was updated, with the {'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None} data.

    The PDF extraction data was updated.

    • The report_metadata property was set to None.
    • The st_metadata property was set to None.
    • The report_frontpage property was set to None.
    • The report_keywords property was set to None.
    • The st_keywords property was set to None.
    • The report_filename property was set to None.
    • The st_filename property was set to None.

    The computed heuristics were updated.

    • The cert_lab property was set to None.
    • The cert_id property was set to None.
    • The report_references property was updated, with the {'directly_referenced_by': None, 'indirectly_referenced_by': None, 'directly_referencing': None, 'indirectly_referencing': None} data.
    • The extracted_sars property was updated, with the {'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DVS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_IND', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_INT', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_SPM', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_PRE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'APE_SPD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_FLR', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}]} values discarded.
  • 23.07.2024 The certificate was first processed.
    New certificate

    A new Common Criteria certificate with the product name TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA was processed.

Raw data

{
  "_type": "sec_certs.sample.cc.CCCertificate",
  "category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
  "cert_link": null,
  "dgst": "d6739d0e1ce9ed2c",
  "heuristics": {
    "_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
    "annotated_references": null,
    "cert_id": "BSI-DSZ-CC-0957-2015",
    "cert_lab": [
      "BSI"
    ],
    "cpe_matches": null,
    "direct_transitive_cves": null,
    "extracted_sars": {
      "_type": "Set",
      "elements": [
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "APE_CCL",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_SPD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "APE_REQ",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_FSP",
          "level": 4
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_IMP",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "APE_OBJ",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AVA_VAN",
          "level": 5
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_COV",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_TDS",
          "level": 3
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_TAT",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AGD_PRE",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "AGD_OPE",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_CMC",
          "level": 4
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_FUN",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_FLR",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_IND",
          "level": 3
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_OBJ",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "APE_SPD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_LCD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_ECD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "APE_INT",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_INT",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_REQ",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_DVS",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_ARC",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ATE_DPT",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_SPM",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_CMS",
          "level": 4
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "APE_ECD",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_TSS",
          "level": 2
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ADV_INT",
          "level": 3
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ASE_CCL",
          "level": 1
        },
        {
          "_type": "sec_certs.sample.sar.SAR",
          "family": "ALC_DEL",
          "level": 1
        }
      ]
    },
    "extracted_versions": {
      "_type": "Set",
      "elements": [
        "1.0"
      ]
    },
    "indirect_transitive_cves": null,
    "related_cves": null,
    "report_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": {
        "_type": "Set",
        "elements": [
          "BSI-DSZ-CC-0957-V2-2016"
        ]
      },
      "directly_referencing": {
        "_type": "Set",
        "elements": [
          "BSI-DSZ-CC-0845-V2-2013"
        ]
      },
      "indirectly_referenced_by": {
        "_type": "Set",
        "elements": [
          "BSI-DSZ-CC-0918-V4-2022",
          "BSI-DSZ-CC-0919-V2-2021",
          "BSI-DSZ-CC-0831-V9-2024",
          "BSI-DSZ-CC-0831-V5-2022",
          "BSI-DSZ-CC-0918-V5-2023",
          "BSI-DSZ-CC-0831-V3-2021",
          "BSI-DSZ-CC-0831-V7-2023",
          "BSI-DSZ-CC-0831-V4-2021",
          "BSI-DSZ-CC-1035-2017",
          "BSI-DSZ-CC-0831-V8-2024",
          "BSI-DSZ-CC-0831-V2-2020",
          "BSI-DSZ-CC-0831-V6-2023",
          "BSI-DSZ-CC-0957-V2-2016",
          "BSI-DSZ-CC-0918-V6-2024",
          "BSI-DSZ-CC-0919-V3-2023"
        ]
      },
      "indirectly_referencing": {
        "_type": "Set",
        "elements": [
          "BSI-DSZ-CC-0845-2012",
          "BSI-DSZ-CC-0845-V2-2013",
          "BSI-DSZ-CC-0666-2012"
        ]
      }
    },
    "scheme_data": {
      "category": "Intelligent measuring systems",
      "cert_id": "BSI-DSZ-CC-1035-2017",
      "certification_date": "2017-10-06",
      "enhanced": {
        "applicant": "T-Systems International GmbH Untere Industriestra\u00dfe 20 57250 Netphen",
        "assurance_level": "EAL4+,AVA_VAN.5",
        "certification_date": "2017-10-06",
        "description": "The Target of Evaluation (TOE) is the product TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE developed by T-Systems International GmbH. The TOE is a Security Module according to the Technical Guideline BSI TR-03109-2 Annex B, Version 1.0 and is intended to be integrated in a so-called Smart Meter Mini-HSM. The TOE serves as a cryptographic service provider and supports different parties (as e.g. the Gateway Administrator) for their specific cryptographic needs in the framework of Smart Metering Systems. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further sensitive data relevant for the user.",
        "evaluation_facility": "SRC Security Research \u0026 Consulting GmbH",
        "expiration_date": "2027-10-05",
        "product": "TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE",
        "report_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035a_pdf.pdf?__blob=publicationFile\u0026v=1",
        "target_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1035b_pdf.pdf?__blob=publicationFile\u0026v=1"
      },
      "product": "TCOS Secure Crypto Module Version 1.0 Release 1/P60C144PVE",
      "subcategory": "Security module for an Smart Meter Mini-HSM",
      "url": "https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_MiniHSM/1035.html",
      "vendor": "T-Systems International GmbH"
    },
    "st_references": {
      "_type": "sec_certs.sample.certificate.References",
      "directly_referenced_by": null,
      "directly_referencing": null,
      "indirectly_referenced_by": null,
      "indirectly_referencing": null
    },
    "verified_cpe_matches": null
  },
  "maintenance_updates": {
    "_type": "Set",
    "elements": []
  },
  "manufacturer": "T-Systems International GMBH",
  "manufacturer_web": "https://www.t-systems.de/",
  "name": "TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA",
  "not_valid_after": "2025-02-10",
  "not_valid_before": "2015-02-09",
  "pdf_data": {
    "_type": "sec_certs.sample.cc.CCCertificate.PdfData",
    "cert_filename": null,
    "cert_frontpage": null,
    "cert_keywords": null,
    "cert_metadata": null,
    "report_filename": "0957a_pdf.pdf",
    "report_frontpage": {
      "DE": {
        "cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 Valid until (*): 9 February 2025 SOGIS Recognition Agreement",
        "cc_version": "PP conformant Common Criteria Part 2 extended",
        "cert_id": "BSI-DSZ-CC-0957-2015",
        "cert_item": "TCOS Smart Meter Security Module Version 1.0 Release 1/P60C144PVA",
        "cert_lab": "BSI",
        "developer": "T-Systems International GmbH",
        "match_rules": [
          "(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
        ],
        "ref_protection_profiles": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil f\u00fcr das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015"
      }
    },
    "report_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 3
          },
          "ECDSA": {
            "ECDSA": 6
          }
        },
        "FF": {
          "DH": {
            "DH": 2,
            "Diffie-Hellman": 2
          }
        }
      },
      "cc_cert_id": {
        "DE": {
          "BSI-DSZ-CC-00845-V2-2013": 1,
          "BSI-DSZ-CC-0845-V2-2013": 4,
          "BSI-DSZ-CC-0957-2015": 24
        }
      },
      "cc_claims": {},
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0077-V2-2015": 4
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC": 1,
          "ADV_ARC.1": 1,
          "ADV_FSP": 1,
          "ADV_FSP.1": 1,
          "ADV_FSP.2": 1,
          "ADV_FSP.3": 1,
          "ADV_FSP.4": 1,
          "ADV_FSP.5": 1,
          "ADV_FSP.6": 1,
          "ADV_IMP": 1,
          "ADV_IMP.1": 1,
          "ADV_IMP.2": 1,
          "ADV_INT": 1,
          "ADV_INT.1": 1,
          "ADV_INT.2": 1,
          "ADV_INT.3": 1,
          "ADV_SPM": 1,
          "ADV_SPM.1": 1,
          "ADV_TDS": 1,
          "ADV_TDS.1": 1,
          "ADV_TDS.2": 1,
          "ADV_TDS.3": 1,
          "ADV_TDS.4": 1,
          "ADV_TDS.5": 1,
          "ADV_TDS.6": 1
        },
        "AGD": {
          "AGD_OPE": 1,
          "AGD_OPE.1": 1,
          "AGD_PRE": 1,
          "AGD_PRE.1": 1
        },
        "ALC": {
          "ALC_CMC": 1,
          "ALC_CMC.1": 1,
          "ALC_CMC.2": 1,
          "ALC_CMC.3": 1,
          "ALC_CMC.4": 2,
          "ALC_CMC.5": 1,
          "ALC_CMS": 1,
          "ALC_CMS.1": 1,
          "ALC_CMS.2": 1,
          "ALC_CMS.3": 1,
          "ALC_CMS.4": 2,
          "ALC_CMS.5": 1,
          "ALC_DEL": 1,
          "ALC_DEL.1": 2,
          "ALC_DVS": 1,
          "ALC_DVS.1": 2,
          "ALC_DVS.2": 1,
          "ALC_FLR": 3,
          "ALC_FLR.1": 1,
          "ALC_FLR.2": 1,
          "ALC_FLR.3": 1,
          "ALC_LCD.1": 2,
          "ALC_LCD.2": 1,
          "ALC_TAT": 1,
          "ALC_TAT.1": 2,
          "ALC_TAT.2": 1,
          "ALC_TAT.3": 1
        },
        "APE": {
          "APE_CCL.1": 1,
          "APE_ECD.1": 1,
          "APE_INT.1": 1,
          "APE_OBJ.1": 1,
          "APE_OBJ.2": 1,
          "APE_REQ.1": 1,
          "APE_REQ.2": 1,
          "APE_SPD.1": 1
        },
        "ASE": {
          "ASE_CCL": 1,
          "ASE_CCL.1": 1,
          "ASE_ECD": 1,
          "ASE_ECD.1": 1,
          "ASE_INT": 1,
          "ASE_INT.1": 1,
          "ASE_OBJ": 1,
          "ASE_OBJ.1": 1,
          "ASE_OBJ.2": 1,
          "ASE_REQ.1": 1,
          "ASE_REQ.2": 1,
          "ASE_SPD": 1,
          "ASE_SPD.1": 1,
          "ASE_TSS": 1,
          "ASE_TSS.1": 1,
          "ASE_TSS.2": 1
        },
        "ATE": {
          "ATE_COV": 1,
          "ATE_COV.1": 1,
          "ATE_COV.2": 1,
          "ATE_COV.3": 1,
          "ATE_DPT": 1,
          "ATE_DPT.1": 1,
          "ATE_DPT.2": 1,
          "ATE_DPT.3": 1,
          "ATE_DPT.4": 1,
          "ATE_FUN": 1,
          "ATE_FUN.1": 1,
          "ATE_FUN.2": 1,
          "ATE_IND": 1,
          "ATE_IND.1": 1,
          "ATE_IND.2": 1,
          "ATE_IND.3": 1
        },
        "AVA": {
          "AVA_VAN": 2,
          "AVA_VAN.1": 1,
          "AVA_VAN.2": 1,
          "AVA_VAN.3": 1,
          "AVA_VAN.4": 1,
          "AVA_VAN.5": 6
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 1": 7,
          "EAL 2": 4,
          "EAL 3": 4,
          "EAL 4": 13,
          "EAL 4 augmented": 3,
          "EAL 5": 10,
          "EAL 5+": 1,
          "EAL 6": 4,
          "EAL 7": 4
        },
        "ITSEC": {
          "ITSEC Evaluation": 1
        }
      },
      "cc_sfr": {
        "FCS": {
          "FCS_CKM": 4,
          "FCS_COP": 6,
          "FCS_RNG.1": 1
        },
        "FIA": {
          "FIA_UAU.4": 1,
          "FIA_UAU.5": 1,
          "FIA_UID.1": 1
        },
        "FTP": {
          "FTP_ITC.1": 1
        }
      },
      "certification_process": {
        "ConfidentialDocument": {
          "1.0 Release 1/P60C144PVA, Version 1.0, 9 February 2015, SRC Security Research \u0026 Consulting GmbH (confidential document) [9] Configuration List BSI-DSZ-CC-0957-2015, Konfigurationsliste von TCOS Smart Meter Security": 1,
          "Version 1.0 Release 1/P60C144PVA, Version 1.1, 6 February 2015, T-Systems International GmbH (confidential document) 9 specifically \u2022 AIS 1, Version 13, Durchf\u00fchrung der Ortsbesichtigung in der Entwicklungsumgebung": 1,
          "and certification procedure is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the product or resulting from the evaluation and certification": 1
        }
      },
      "cipher_mode": {
        "CBC": {
          "CBC": 3
        }
      },
      "cplc_data": {},
      "crypto_engine": {
        "SmartMX": {
          "SmartMX2": 2
        }
      },
      "crypto_library": {},
      "crypto_protocol": {
        "PACE": {
          "PACE": 7
        },
        "TLS": {
          "TLS": {
            "TLS": 6
          }
        }
      },
      "crypto_scheme": {
        "KA": {
          "KA": 1,
          "Key Agreement": 8
        },
        "MAC": {
          "MAC": 3
        }
      },
      "device_model": {},
      "ecc_curve": {},
      "eval_facility": {
        "SRC": {
          "SRC Security Research \u0026 Consulting": 3
        },
        "TSystems": {
          "T-Systems International": 13
        }
      },
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "RNG": {
          "RNG": 2
        }
      },
      "side_channel_analysis": {
        "FI": {
          "fault injection": 2,
          "malfunction": 1
        },
        "SCA": {
          "side channel": 2
        },
        "other": {
          "JIL": 2
        }
      },
      "standard_id": {
        "BSI": {
          "AIS 1": 1,
          "AIS 20": 3,
          "AIS 25": 1,
          "AIS 26": 3,
          "AIS 31": 1,
          "AIS 32": 1,
          "AIS 34": 2,
          "AIS 36": 4,
          "AIS 46": 1,
          "AIS36": 1
        },
        "FIPS": {
          "FIPS 180-2": 2,
          "FIPS 186": 5,
          "FIPS 197": 2
        },
        "ISO": {
          "ISO/IEC 15408": 4,
          "ISO/IEC 17065": 2,
          "ISO/IEC 18045": 4
        },
        "RFC": {
          "RFC 5639": 5
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 6
          }
        },
        "constructions": {
          "MAC": {
            "CMAC": 3
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI 7125": 2,
          "BSI 7138": 2,
          "BSI 7148": 1,
          "BSI TR-03109-2": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {
        "NXP": {
          "NXP": 11,
          "NXP Semiconductors": 4
        }
      },
      "vulnerability": {}
    },
    "report_metadata": {
      "/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
      "/CreationDate": "D:20150212092005+01\u002700\u0027",
      "/Creator": "Writer",
      "/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter Security Module\"",
      "/ModDate": "D:20150212110928+01\u002700\u0027",
      "/Producer": "LibreOffice 4.2",
      "/Subject": "Common Criteria Zertifizierung",
      "/Title": "Certification Report BSI-DSZ-CC-0957-2015",
      "pdf_file_size_bytes": 1269846,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": [
          "https://www.bsi.bund.de/",
          "https://www.bsi.bund.de/zertifizierung",
          "http://www.commoncriteriaportal.org/"
        ]
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 38
    },
    "st_filename": "0957b_pdf.pdf",
    "st_frontpage": null,
    "st_keywords": {
      "asymmetric_crypto": {
        "ECC": {
          "ECC": {
            "ECC": 11
          },
          "ECDH": {
            "ECDH": 1
          },
          "ECDSA": {
            "ECDSA": 19
          }
        },
        "FF": {
          "DH": {
            "DH": 13,
            "Diffie-Hellman": 5
          }
        }
      },
      "cc_cert_id": {
        "DE": {
          "BSI-DSZ-CC-0957": 1
        }
      },
      "cc_claims": {
        "O": {
          "O.FW_HW": 1,
          "O.HW_AES": 4,
          "O.MEM_ACCESS": 3,
          "O.PACE": 5,
          "O.RND": 3,
          "O.SFR_ACCESS": 3
        },
        "OE": {
          "OE.PACE": 1
        },
        "OSP": {
          "OSP.SM": 1
        },
        "T": {
          "T.RND": 1
        }
      },
      "cc_protection_profile_id": {
        "BSI": {
          "BSI-CC-PP-0035-2007": 1,
          "BSI-CC-PP-0073-2014": 1,
          "BSI-CC-PP-0077-V2-2015": 2
        }
      },
      "cc_sar": {
        "ADV": {
          "ADV_ARC": 1,
          "ADV_ARC.1": 1,
          "ADV_FSP": 1,
          "ADV_FSP.4": 1,
          "ADV_IMP.1": 3,
          "ADV_TDS": 2,
          "ADV_TDS.3": 1
        },
        "AGD": {
          "AGD_OPE.1": 1,
          "AGD_PRE.1": 3
        },
        "ALC": {
          "ALC_CMC.4": 1,
          "ALC_CMS.4": 1,
          "ALC_DEL.1": 3,
          "ALC_DVS.1": 1,
          "ALC_FLR.1": 2,
          "ALC_LCD.1": 1,
          "ALC_TAT.1": 1
        },
        "ASE": {
          "ASE_TSS.2": 2
        },
        "ATE": {
          "ATE_COV.2": 1,
          "ATE_DPT.1": 1,
          "ATE_FUN.1": 1
        },
        "AVA": {
          "AVA_VAN.5": 10
        }
      },
      "cc_security_level": {
        "EAL": {
          "EAL 4": 5,
          "EAL 6": 1,
          "EAL 6 augmented": 1,
          "EAL 6+": 1,
          "EAL4": 4,
          "EAL4 augmented": 3
        }
      },
      "cc_sfr": {
        "FAU": {
          "FAU_SAS.1": 1
        },
        "FCS": {
          "FCS_CKM": 49,
          "FCS_CKM.1": 16,
          "FCS_CKM.2": 8,
          "FCS_CKM.4": 45,
          "FCS_CKM.4.1": 1,
          "FCS_COP": 59,
          "FCS_COP.1": 17,
          "FCS_RNG": 6,
          "FCS_RNG.1": 20,
          "FCS_RNG.1.1": 2,
          "FCS_RNG.1.2": 2
        },
        "FDP": {
          "FDP_ACC.1": 13,
          "FDP_ACC.2": 17,
          "FDP_ACC.2.1": 1,
          "FDP_ACC.2.2": 1,
          "FDP_ACF": 2,
          "FDP_ACF.1": 9,
          "FDP_ACF.1.1": 1,
          "FDP_ACF.1.2": 1,
          "FDP_ACF.1.3": 1,
          "FDP_ACF.1.4": 1,
          "FDP_ETC.1": 7,
          "FDP_ETC.1.1": 1,
          "FDP_ETC.1.2": 1,
          "FDP_IFC": 1,
          "FDP_IFC.1": 8,
          "FDP_ITC": 8,
          "FDP_ITC.1": 20,
          "FDP_ITC.1.1": 1,
          "FDP_ITC.1.2": 1,
          "FDP_ITC.1.3": 1,
          "FDP_ITC.2": 14,
          "FDP_ITT.1": 1,
          "FDP_RIP": 1,
          "FDP_RIP.1": 7,
          "FDP_RIP.1.1": 1,
          "FDP_SDI": 1,
          "FDP_SDI.1": 1,
          "FDP_SDI.2": 7,
          "FDP_SDI.2.1": 1,
          "FDP_SDI.2.2": 1,
          "FDP_UCT.1": 8,
          "FDP_UIT": 1,
          "FDP_UIT.1": 7,
          "FDP_UIT.1.1": 1,
          "FDP_UIT.1.2": 1
        },
        "FIA": {
          "FIA_ATD.1": 10,
          "FIA_ATD.1.1": 1,
          "FIA_SOS": 1,
          "FIA_SOS.1": 3,
          "FIA_SOS.1.1": 1,
          "FIA_UAU": 18,
          "FIA_UAU.1": 5,
          "FIA_UAU.4": 6,
          "FIA_UAU.4.1": 1,
          "FIA_UAU.5": 6,
          "FIA_UAU.5.1": 1,
          "FIA_UAU.5.2": 1,
          "FIA_UID": 1,
          "FIA_UID.1": 14,
          "FIA_UID.1.1": 1,
          "FIA_UID.1.2": 1,
          "FIA_USB": 1,
          "FIA_USB.1": 6,
          "FIA_USB.1.1": 1,
          "FIA_USB.1.2": 1,
          "FIA_USB.1.3": 1
        },
        "FMT": {
          "FMT_LIM": 6,
          "FMT_LIM.1": 25,
          "FMT_LIM.1.1": 2,
          "FMT_LIM.2": 23,
          "FMT_LIM.2.1": 2,
          "FMT_MSA.1": 2,
          "FMT_MSA.3": 6,
          "FMT_SMF.1": 10,
          "FMT_SMF.1.1": 1,
          "FMT_SMR": 1,
          "FMT_SMR.1": 6,
          "FMT_SMR.1.1": 1,
          "FMT_SMR.1.2": 1
        },
        "FPT": {
          "FPT_EMS": 6,
          "FPT_EMS.1": 15,
          "FPT_EMS.1.1": 2,
          "FPT_EMS.1.2": 2,
          "FPT_FLS": 1,
          "FPT_FLS.1": 11,
          "FPT_FLS.1.1": 1,
          "FPT_ITT.1": 1,
          "FPT_PHP": 1,
          "FPT_PHP.3": 10,
          "FPT_PHP.3.1": 1,
          "FPT_TST": 1,
          "FPT_TST.1": 7,
          "FPT_TST.1.1": 1,
          "FPT_TST.1.2": 1,
          "FPT_TST.1.3": 1
        },
        "FRU": {
          "FRU_FLT.2": 1
        },
        "FTP": {
          "FTP_ICT.1": 4,
          "FTP_ITC": 1,
          "FTP_ITC.1": 10,
          "FTP_ITC.1.1": 1,
          "FTP_ITC.1.2": 1,
          "FTP_ITC.1.3": 1,
          "FTP_TRP.1": 4
        }
      },
      "certification_process": {
        "OutOfScope": {
          "entities. 72 As these external entities only indirectly interact with the TOE, these entities are out of scope for this ST. 73 During its pre-operational phases the TOE interacts with the Integrator and the": 1,
          "out of scope": 1
        }
      },
      "cipher_mode": {
        "CBC": {
          "CBC": 4
        }
      },
      "cplc_data": {},
      "crypto_engine": {},
      "crypto_library": {},
      "crypto_protocol": {
        "PACE": {
          "PACE": 66
        },
        "TLS": {
          "TLS": {
            "TLS": 28
          }
        }
      },
      "crypto_scheme": {
        "KA": {
          "Key Agreement": 17
        },
        "MAC": {
          "MAC": 2
        }
      },
      "device_model": {},
      "ecc_curve": {
        "Brainpool": {
          "brainpoolP256r1": 2,
          "brainpoolP384r1": 2,
          "brainpoolP512r1": 2
        },
        "NIST": {
          "NIST P-256": 1,
          "NIST P-384": 1,
          "P-256": 13,
          "P-384": 15,
          "secp256r1": 1,
          "secp384r1": 1
        }
      },
      "eval_facility": {
        "TSystems": {
          "T-Systems International": 78
        }
      },
      "hash_function": {},
      "ic_data_group": {},
      "javacard_api_const": {},
      "javacard_packages": {},
      "javacard_version": {},
      "os_name": {},
      "pq_crypto": {},
      "randomness": {
        "RNG": {
          "RND": 4,
          "RNG": 8
        }
      },
      "side_channel_analysis": {
        "FI": {
          "DFA": 1,
          "Malfunction": 12,
          "Physical tampering": 1,
          "fault injection": 1,
          "malfunction": 3,
          "physical tampering": 5
        },
        "SCA": {
          "DPA": 2,
          "Leak-Inherent": 4,
          "Physical Probing": 2,
          "SPA": 2,
          "physical probing": 2,
          "side channel": 1,
          "side channels": 1,
          "side-channels": 1,
          "timing attacks": 1
        }
      },
      "standard_id": {
        "BSI": {
          "AIS 36": 1,
          "AIS36": 3
        },
        "CC": {
          "CCMB-2012-09-001": 1,
          "CCMB-2012-09-002": 1,
          "CCMB-2012-09-003": 2,
          "CCMB-2012-09-004": 2
        },
        "FIPS": {
          "FIPS PUB 186-3": 1,
          "FIPS186": 10,
          "FIPS197": 3
        },
        "ISO": {
          "ISO/IEC 7810:2003": 1
        },
        "RFC": {
          "RFC 5639": 1,
          "RFC5639": 11
        },
        "X509": {
          "X.509": 2
        }
      },
      "symmetric_crypto": {
        "AES_competition": {
          "AES": {
            "AES": 16
          }
        },
        "DES": {
          "3DES": {
            "TDES": 3,
            "Triple-DES": 2
          },
          "DES": {
            "DES": 4
          }
        },
        "constructions": {
          "MAC": {
            "CMAC": 4
          }
        }
      },
      "technical_report_id": {
        "BSI": {
          "BSI TR-03109": 1
        }
      },
      "tee_name": {},
      "tls_cipher_suite": {},
      "vendor": {
        "NXP": {
          "NXP": 2,
          "NXP Semiconductors": 1
        }
      },
      "vulnerability": {}
    },
    "st_metadata": {
      "/Author": "T-Systems International GmbH",
      "/CreationDate": "D:20150209010001",
      "/Creator": "PScript5.dll Version 5.2.2",
      "/Keywords": "TCOS Security Module, Sicherheitsmodul, Smart Meter",
      "/ModDate": "D:20150209135248+01\u002700\u0027",
      "/Producer": "TeleSec ps2pdf",
      "/Subject": "TCOS Smart Meter Security Module Version 1.0 Release 1",
      "/Title": "Security Target TCOS Smart Meter Security Module (NXP)",
      "pdf_file_size_bytes": 631545,
      "pdf_hyperlinks": {
        "_type": "Set",
        "elements": []
      },
      "pdf_is_encrypted": false,
      "pdf_number_of_pages": 75
    }
  },
  "protection_profiles": {
    "_type": "Set",
    "elements": [
      {
        "_type": "sec_certs.sample.protection_profile.ProtectionProfile",
        "pp_eal": null,
        "pp_ids": null,
        "pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0077V2b_pdf.pdf",
        "pp_name": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - ..."
      }
    ]
  },
  "report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957a_pdf.pdf",
  "scheme": "DE",
  "security_level": {
    "_type": "Set",
    "elements": [
      "AVA_VAN.5",
      "EAL4+"
    ]
  },
  "st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0957b_pdf.pdf",
  "state": {
    "_type": "sec_certs.sample.cc.CCCertificate.InternalState",
    "cert": {
      "_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
      "convert_garbage": false,
      "convert_ok": false,
      "download_ok": false,
      "extract_ok": false,
      "pdf_hash": null,
      "txt_hash": null
    },
    "report": {
      "_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "ea00160fcee4f78538be1c86549e6382c013030bb017992b97e52bd704a9ef00",
      "txt_hash": "94fabf42b757720ecc5075548e90b46379477647d421144f719ebd1e9c78bf3d"
    },
    "st": {
      "_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
      "convert_garbage": false,
      "convert_ok": true,
      "download_ok": true,
      "extract_ok": true,
      "pdf_hash": "cb5120b6071479f829d11b4ee58151704004478cab408bec581a673cfb5275a8",
      "txt_hash": "112a724c5dc3fcff2799c05109e515d6ffb54da328d412ea3aabdcaf44402a73"
    }
  },
  "status": "active"
}