name |
bizhub PRO 1050 control software Image control program(Image control I1):11-0000 Controller control program(IP control P1):10-0000 |
SMARTY IQ-GPRS / LTE, Version 1.1 |
category |
Other Devices and Systems |
Other Devices and Systems |
scheme |
JP |
DE |
status |
archived |
active |
not_valid_after |
07.10.2013 |
29.03.2029 |
not_valid_before |
21.02.2005 |
30.03.2021 |
cert_link |
|
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3c_pdf.pdf |
report_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/c0019_erpt.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3a_pdf.pdf |
st_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/c0019_est.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V3b_pdf.pdf |
manufacturer |
Konica Minolta Business Technologies, Inc |
Sagemcom Dr. Neuhaus GmbH |
manufacturer_web |
https://www.konicaminolta.com/ |
https://sagemcom.com |
security_level |
EAL3 |
EAL4+, ALC_FLR.2, AVA_VAN.5 |
dgst |
f7247eee0c64bc9d |
867fc6e2eb21f381 |
heuristics/cert_id |
JISEC-CC-CRP-C0019 |
BSI-DSZ-CC-0822-V3-2021 |
heuristics/cert_lab |
[] |
BSI |
heuristics/cpe_matches |
{} |
{} |
heuristics/verified_cpe_matches |
{} |
{} |
heuristics/related_cves |
{} |
{} |
heuristics/direct_transitive_cves |
{} |
{} |
heuristics/indirect_transitive_cves |
{} |
{} |
heuristics/extracted_sars |
ALC_DVS.1, ATE_COV.2, ADV_RCR.1, ADV_FSP.1, ADV_HLD.2, ATE_FUN.1, AGD_USR.1, AVA_VLA.1, ATE_IND.2, AGD_ADM.1, AVA_MSU.1, ATE_DPT.1, AVA_SOF.1 |
ATE_COV.2, ASE_TSS.1, ASE_INT.1, ATE_FUN.1, AVA_VAN.5, ALC_DEL.1, ALC_LCD.1, ADV_ARC.1, AGD_OPE.1, ASE_REQ.2, ASE_CCL.1, ALC_CMC.4, ALC_FLR.2, ADV_IMP.1 |
heuristics/extracted_versions |
11, 1050, 10, 0000 |
1.1 |
heuristics/prev_certificates |
{} |
{} |
heuristics/next_certificates |
{} |
{} |
heuristics/report_references/directly_referenced_by |
{} |
BSI-DSZ-CC-0822-V4-2023 |
heuristics/report_references/directly_referencing |
{} |
BSI-DSZ-CC-0822-V2-2020 |
heuristics/report_references/indirectly_referenced_by |
{} |
BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0822-V6-2024, BSI-DSZ-CC-0822-V5-2023 |
heuristics/report_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0822-V2-2020 |
heuristics/scheme_data |
- cert_id: JISEC-CC-CRP-C0019
- certification_date: 01.02.2005
- claim: EAL3
- enhanced:
- assurance_level: EAL3
- cc_version: 2.1
- cert_link: https://www.ipa.go.jp/en/security/c0019_eimg.pdf
- description: PRODUCT DESCRIPTION This product (it is called "bizhub PRO 1050 control software (*1)", hereafter.) is the software installed with digital MFP (it is called "bizhub PRO 1050 series", hereafter.) manufactured by Konica Minolta Business Technologies, Inc. and for the purpose of reducing the danger to be leaked the document data stored by every user.Bizhub PRO 1050 control software prevents the document data from leaking in the function to use copier and printer etc. To protect the document data, this software has "User BOX" function and several control capabilities, additionally high-confidential hard disk drive (HDD) with lock system (*2) to store the document.Bizhub PRO 1050 control software is provided with bizhub PRO 1050 series. (*1) "bizhub PRO 1050 zentai seigyo software" for Japan and "bizhub PRO 1050 control software" are the same product with different calling name. (*2) HDD has the password so that the hard disk cannot be removed and read in another equipment.
- evaluation_facility: Japan Electronics and Information Technology Industries Association, Information Technology Security Center(JEITA ITSC)
- product: Japan: bizhub PRO 1050 zentai seigyo software Overseas: bizhub PRO 1050 control software
- product_type: IT Product (data protection function in digital MFD)
- report_link: https://www.ipa.go.jp/en/security/c0019_erpt.pdf
- target_link: https://www.ipa.go.jp/en/security/c0019_est2.pdf
- toe_version: Image control program(Image control I1):11-0000 Controller control program(IP control P1):10-0000
- vendor: Konica Minolta Business Technologies, Inc.
- expiration_date: 01.10.2013
- revalidations: [frozendict({'date': '2008-10', 'link': 'https://www.ipa.go.jp/en/security/jisec/software/certified-cert/c0019_it4027_06.html'})]
- supplier: Konica Minolta Business Technologies, Inc.
- toe_japan_name: bizhub PRO 1050 control software Image control program(Image control I1):11-0000 Controller control program(IP control P1):10-0000
- toe_overseas_link: https://www.ipa.go.jp/en/security/jisec/software/certified-cert/c0019_it4027.html
- toe_overseas_name: bizhub PRO 1050/1050e control software Image control program (Image control I1) : 70-0000 Controller control program (IP control P1) : 31-0000
|
|
heuristics/st_references/directly_referenced_by |
{} |
{} |
heuristics/st_references/directly_referencing |
{} |
{} |
heuristics/st_references/indirectly_referenced_by |
{} |
{} |
heuristics/st_references/indirectly_referencing |
{} |
{} |
heuristics/protection_profiles |
{} |
6346b04de6859db3 |
maintenance_updates |
|
|
protection_profiles |
|
|
protection_profile_links |
{} |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073b_pdf.pdf |
pdf_data/cert_filename |
|
0822V3c_pdf.pdf |
pdf_data/cert_frontpage |
|
|
pdf_data/cert_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0822-V3-2021: 1
|
pdf_data/cert_keywords/cc_protection_profile_id |
|
|
pdf_data/cert_keywords/cc_security_level |
|
- EAL:
- EAL 2: 1
- EAL 4: 2
- EAL 4 augmented: 1
- EAL 5: 1
|
pdf_data/cert_keywords/cc_sar |
|
|
pdf_data/cert_keywords/cc_sfr |
|
|
pdf_data/cert_keywords/cc_claims |
|
|
pdf_data/cert_keywords/vendor |
|
|
pdf_data/cert_keywords/eval_facility |
|
|
pdf_data/cert_keywords/symmetric_crypto |
|
|
pdf_data/cert_keywords/asymmetric_crypto |
|
|
pdf_data/cert_keywords/pq_crypto |
|
|
pdf_data/cert_keywords/hash_function |
|
|
pdf_data/cert_keywords/crypto_scheme |
|
|
pdf_data/cert_keywords/crypto_protocol |
|
|
pdf_data/cert_keywords/randomness |
|
|
pdf_data/cert_keywords/cipher_mode |
|
|
pdf_data/cert_keywords/ecc_curve |
|
|
pdf_data/cert_keywords/crypto_engine |
|
|
pdf_data/cert_keywords/tls_cipher_suite |
|
|
pdf_data/cert_keywords/crypto_library |
|
|
pdf_data/cert_keywords/vulnerability |
|
|
pdf_data/cert_keywords/side_channel_analysis |
|
|
pdf_data/cert_keywords/technical_report_id |
|
|
pdf_data/cert_keywords/device_model |
|
|
pdf_data/cert_keywords/tee_name |
|
|
pdf_data/cert_keywords/os_name |
|
|
pdf_data/cert_keywords/cplc_data |
|
|
pdf_data/cert_keywords/ic_data_group |
|
|
pdf_data/cert_keywords/standard_id |
|
- ISO:
- ISO/IEC 15408: 2
- ISO/IEC 18045: 2
|
pdf_data/cert_keywords/javacard_version |
|
|
pdf_data/cert_keywords/javacard_api_const |
|
|
pdf_data/cert_keywords/javacard_packages |
|
|
pdf_data/cert_keywords/certification_process |
|
|
pdf_data/cert_metadata |
|
- /Author: Bundesamt für Sicherheit in der Informationstechnik
- /CreationDate: D:20210330140145+02'00'
- /Creator: Writer
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus"
- /ModDate: D:20210415101023+02'00'
- /Producer: LibreOffice 6.3
- /Subject: Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH
- /Title: Certification Report BSI-DSZ-CC-0822-V3-2021
- pdf_file_size_bytes: 238250
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
pdf_data/report_filename |
c0019_erpt.pdf |
0822V3a_pdf.pdf |
pdf_data/report_frontpage |
|
- DE:
- cc_security_level: Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5 and ALC_FLR.2
- cc_version: PP conformant Common Criteria Part 2 extended
- cert_id: BSI-DSZ-CC-0822-V3-2021
- cert_item: SMARTY IQ-LTE, Version 1.1
- cert_lab: BSI
- developer: Sagemcom Dr. Neuhaus GmbH
- match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
- ref_protection_profiles: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014
|
pdf_data/report_keywords/cc_cert_id |
- JP:
- CRP-C0019-01: 1
- Certification No. C0019: 1
|
- DE:
- BSI-DSZ-CC-0822-: 1
- BSI-DSZ-CC-0822-V2-2020: 3
- BSI-DSZ-CC-0822-V3-2021: 15
- BSI-DSZ-CC-0957-: 1
|
pdf_data/report_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073-2014: 3
- BSI-CC-PP-0077-V2-2015: 2
|
pdf_data/report_keywords/cc_security_level |
|
- EAL:
- EAL 1: 1
- EAL 2: 3
- EAL 4: 8
- EAL 4 augmented: 3
- EAL 5: 3
- EAL 5+: 1
- EAL 6: 1
|
pdf_data/report_keywords/cc_sar |
|
|
pdf_data/report_keywords/cc_sfr |
|
|
pdf_data/report_keywords/cc_claims |
- T:
- T.ACCESS: 1
- T.HDDACCESS: 1
- T.IMPADMIN: 1
|
|
pdf_data/report_keywords/vendor |
|
|
pdf_data/report_keywords/eval_facility |
- ITSC:
- Information Technology Security Center: 3
|
- TUV:
- TÜV Informationstechnik: 3
|
pdf_data/report_keywords/symmetric_crypto |
|
- AES_competition:
- constructions:
|
pdf_data/report_keywords/asymmetric_crypto |
|
|
pdf_data/report_keywords/pq_crypto |
|
|
pdf_data/report_keywords/hash_function |
|
|
pdf_data/report_keywords/crypto_scheme |
|
|
pdf_data/report_keywords/crypto_protocol |
|
|
pdf_data/report_keywords/randomness |
|
|
pdf_data/report_keywords/cipher_mode |
|
|
pdf_data/report_keywords/ecc_curve |
|
|
pdf_data/report_keywords/crypto_engine |
|
|
pdf_data/report_keywords/tls_cipher_suite |
|
|
pdf_data/report_keywords/crypto_library |
|
|
pdf_data/report_keywords/vulnerability |
|
|
pdf_data/report_keywords/side_channel_analysis |
|
|
pdf_data/report_keywords/technical_report_id |
|
- BSI:
- BSI 7148: 1
- BSI TR-03109: 1
|
pdf_data/report_keywords/device_model |
|
|
pdf_data/report_keywords/tee_name |
|
|
pdf_data/report_keywords/os_name |
|
|
pdf_data/report_keywords/cplc_data |
|
|
pdf_data/report_keywords/ic_data_group |
|
|
pdf_data/report_keywords/standard_id |
- CC:
- CCIMB-99-031: 1
- CCIMB-99-032: 2
- CCIMB-99-033: 2
|
- BSI:
- AIS 32: 1
- AIS 34: 2
- AIS 46: 2
- AIS 48: 1
- FIPS:
- FIPS 186-4: 1
- FIPS PUB 180-4: 1
- FIPS PUB 186: 1
- FIPS180-4: 3
- ISO:
- ISO/IEC 15408: 4
- ISO/IEC 17065: 2
- ISO/IEC 18045: 4
- RFC:
- RFC 2104: 1
- RFC 5246: 1
- RFC 5639: 1
- RFC 5652: 1
- RFC 8289: 1
- RFC 8422: 1
- RFC2104: 2
- RFC4493: 6
- RFC5084: 2
- RFC5246: 6
- RFC5288: 2
- RFC5289: 3
- RFC5639: 6
- RFC5652: 4
- RFC6033: 2
- RFC6090: 4
- RFC6161: 2
- RFC8422: 2
|
pdf_data/report_keywords/javacard_version |
|
|
pdf_data/report_keywords/javacard_api_const |
|
|
pdf_data/report_keywords/javacard_packages |
|
|
pdf_data/report_keywords/certification_process |
|
- ConfidentialDocument:
- 9] Configuration list for the TOE (confidential documents) filelist_os3036, 2021-03-16 filelist_3036, 2020-12-09 8209SE011_SMGw_CPU_USB.xls, Version 3.3: 1
- Technical Report BSI-DSZ-CC-0822-V3, Version 2, 2021-03-04, TÜV Informationstechnik GmbH (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014: 1
- being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
|
pdf_data/report_metadata |
- /CreationDate: D:20050812114303+09'00'
- /ModDate: D:20050812114303+09'00'
- /Producer: Acrobat Distiller 6.0.1 (Windows)
- /Title: untitled
- pdf_file_size_bytes: 203262
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 24
|
- /Author: Bundesamt für Sicherheit in der Informationstechnik
- /CreationDate: D:20210726131537+02'00'
- /Creator: Writer
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smart Metering, Smart Grid, Sagemcom Dr. Neuhaus"
- /ModDate: D:20210726135603+02'00'
- /Producer: LibreOffice 6.3
- /Subject: Certification Report SMARTY IQ-LTE, Version 1.1 from Sagemcom Dr. Neuhaus GmbH
- /Title: Certification Report BSI-DSZ-CC-0822-V3-2021
- pdf_file_size_bytes: 656098
- pdf_hyperlinks: http://www.commoncriteriaportal.org/cc/, https://www.sogis.eu/, http://tools.ietf.org/html/rfc5652, https://www.bsi.bund.de/AIS, https://tools.ietf.org/html/rfc5289, http://www.commoncriteriaportal.org/, http://www.ietf.org/rfc/rfc5246.txt, https://www.bsi.bund.de/zertifizierung, https://tools.ietf.org/html/rfc4493, https://www.bsi.bund.de/zertifizierungsreporte, https://tools.ietf.org/html/rfc5084, https://www.bsi.bund.de/
- pdf_is_encrypted: False
- pdf_number_of_pages: 28
|
pdf_data/st_filename |
c0019_est.pdf |
0822V3b_pdf.pdf |
pdf_data/st_frontpage |
|
|
pdf_data/st_keywords/cc_cert_id |
|
|
pdf_data/st_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073: 1
- BSI-CC-PP-0077-2013: 1
|
pdf_data/st_keywords/cc_security_level |
|
- EAL:
- EAL 4: 5
- EAL 4 augmented: 2
- EAL4: 1
- EAL4 augmented: 1
|
pdf_data/st_keywords/cc_sar |
- ACM:
- ACM_CAP.3: 2
- ACM_SCP.1: 2
- ADO:
- ADO_DEL.1: 2
- ADO_IGS.1: 2
- ADV:
- ADV_FSP.1: 2
- ADV_HLD.2: 2
- ADV_RCR.1: 2
- AGD:
- AGD_ADM.1: 2
- AGD_USR.1: 2
- ALC:
- ATE:
- ATE_COV.2: 2
- ATE_DPT.1: 2
- ATE_FUN.1: 2
- ATE_IND.2: 2
- AVA:
- AVA_MSU.1: 2
- AVA_SOF.1: 2
- AVA_VLA.1: 2
|
- ADV:
- ADV_ARC.1: 1
- ADV_IMP.1: 1
- AGD:
- ALC:
- ALC_CMC.4: 1
- ALC_DEL.1: 1
- ALC_FLR.2: 6
- ALC_LCD.1: 1
- ASE:
- ASE_CCL.1: 1
- ASE_INT.1: 1
- ASE_REQ.2: 1
- ASE_TSS.1: 1
- ATE:
- ATE_COV.2: 1
- ATE_FUN.1: 1
- AVA:
|
pdf_data/st_keywords/cc_sfr |
- FAU:
- FAU_GEN: 3
- FAU_GEN.1: 16
- FAU_GEN.1.1: 1
- FAU_GEN.1.2: 1
- FAU_SAR.1: 13
- FAU_SAR.1.1: 1
- FAU_SAR.2: 11
- FAU_SAR.2.1: 1
- FAU_STG.1: 13
- FAU_STG.1.1: 1
- FAU_STG.1.2: 1
- FAU_STG.3: 1
- FAU_STG.4: 10
- FDP:
- FDP_ACC.1: 26
- FDP_ACC.1.1: 2
- FDP_ACF.1: 28
- FDP_ACF.1.1: 2
- FDP_ACF.1.2: 2
- FDP_ACF.1.3: 2
- FDP_ACF.1.4: 2
- FDP_IFC.1: 1
- FDP_MTD.1: 16
- FDP_MTD.1.1: 1
- FDP_SOS: 1
- FDP_SOS.1: 20
- FDP_SOS.1.1: 1
- FDP_UAU.2: 1
- FDP_UID.2: 1
- FIA:
- FIA_AFL: 1
- FIA_AFL.1: 13
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_SOS: 2
- FIA_SOS.1: 32
- FIA_SOS.1.1: 2
- FIA_UAU: 2
- FIA_UAU.1: 9
- FIA_UAU.2: 20
- FIA_UAU.2.1: 1
- FIA_UAU.7: 15
- FIA_UAU.7.1: 1
- FIA_UID: 1
- FIA_UID.1: 10
- FIA_UID.2: 23
- FMT:
- FMT_MOF.1: 43
- FMT_MOF.1.1: 1
- FMT_MSA.1: 13
- FMT_MSA.1.1: 1
- FMT_MSA.3: 15
- FMT_MSA.3.1: 1
- FMT_MSA.3.2: 1
- FMT_MTD.1: 56
- FMT_MTD.1.1: 5
- FMT_RVM.1: 1
- FMT_SMF.1: 24
- FMT_SMF.1.1: 1
- FMT_SMR.1: 29
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPT:
- FPT_RVM.1: 39
- FPT_RVM.1.1: 1
- FPT_SEP.1: 1
- FPT_STM.1: 10
- FPT_STM.1.1: 1
|
- FAU:
- FAU_ARP: 10
- FAU_ARP.1: 1
- FAU_CON.1.2: 1
- FAU_GEN: 39
- FAU_GEN.1: 17
- FAU_GEN.2: 10
- FAU_GEN.2.1: 1
- FAU_SAA: 15
- FAU_SAA.1: 4
- FAU_SAR: 30
- FAU_SAR.1: 6
- FAU_STG: 34
- FAU_STG.1: 8
- FAU_STG.2: 10
- FAU_STG.2.1: 1
- FAU_STG.2.2: 1
- FAU_STG.2.3: 1
- FAU_STG.3: 3
- FAU_STG.4: 3
- FCO:
- FCO_NRO: 3
- FCO_NRO.1: 1
- FCO_NRO.2: 10
- FCO_NRO.2.1: 1
- FCO_NRO.2.2: 1
- FCO_NRO.2.3: 1
- FCS:
- FCS_CKM: 51
- FCS_CKM.1: 16
- FCS_CKM.2: 6
- FCS_CKM.4: 30
- FCS_CKM.4.1: 1
- FCS_COP: 68
- FCS_COP.1: 11
- FDP:
- FDP_ACC: 2
- FDP_ACC.1: 9
- FDP_ACC.2: 12
- FDP_ACC.2.1: 1
- FDP_ACC.2.2: 1
- FDP_ACF: 1
- FDP_ACF.1: 11
- FDP_ACF.1.1: 1
- FDP_ACF.1.2: 1
- FDP_ACF.1.3: 1
- FDP_ACF.1.4: 1
- FDP_IFC: 29
- FDP_IFC.1: 12
- FDP_IFC.2: 4
- FDP_IFF: 26
- FDP_IFF.1: 18
- FDP_ITC.1: 12
- FDP_ITC.2: 12
- FDP_RIP: 2
- FDP_RIP.1: 1
- FDP_RIP.2: 8
- FDP_RIP.2.1: 1
- FDP_SDI: 2
- FDP_SDI.1: 1
- FDP_SDI.2: 9
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FIA:
- FIA_AFL: 3
- FIA_AFL.1: 10
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_ATD: 3
- FIA_ATD.1: 13
- FIA_ATD.1.1: 1
- FIA_UAU: 5
- FIA_UAU.1: 2
- FIA_UAU.2: 9
- FIA_UAU.2.1: 1
- FIA_UAU.5: 9
- FIA_UAU.5.1: 1
- FIA_UAU.5.2: 1
- FIA_UAU.6: 10
- FIA_UAU.6.1: 1
- FIA_UID: 3
- FIA_UID.1: 8
- FIA_UID.2: 14
- FIA_UID.2.1: 1
- FIA_USB: 3
- FIA_USB.1: 9
- FIA_USB.1.1: 1
- FIA_USB.1.2: 1
- FIA_USB.1.3: 1
- FMT:
- FMT_MOF: 1
- FMT_MOF.1: 9
- FMT_MOF.1.1: 1
- FMT_MSA: 64
- FMT_MSA.1: 9
- FMT_MSA.3: 12
- FMT_SMF: 2
- FMT_SMF.1: 19
- FMT_SMF.1.1: 1
- FMT_SMR: 3
- FMT_SMR.1: 29
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPR:
- FPR_CON: 6
- FPR_CON.1: 12
- FPR_CON.1.1: 3
- FPR_CON.1.2: 3
- FPR_PSE: 3
- FPR_PSE.1: 8
- FPR_PSE.1.1: 1
- FPR_PSE.1.2: 1
- FPR_PSE.1.3: 1
- FPT:
- FPT_FLS: 3
- FPT_FLS.1: 9
- FPT_FLS.1.1: 2
- FPT_PHP: 3
- FPT_PHP.1: 8
- FPT_PHP.1.1: 1
- FPT_PHP.1.2: 1
- FPT_RPL: 3
- FPT_RPL.1: 10
- FPT_RPL.1.1: 1
- FPT_RPL.1.2: 1
- FPT_STM: 3
- FPT_STM.1: 20
- FPT_STM.1.1: 1
- FPT_TST: 3
- FPT_TST.1: 10
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FTP:
|
pdf_data/st_keywords/cc_claims |
- O:
- O.AUDIT: 9
- O.CE: 5
- O.DATAACCESS: 8
- O.IA: 11
- O.MANAGE: 7
- OE:
- OE.ADMIN: 4
- OE.CE: 4
- OE.HDD: 6
- OE.NET: 4
- OE.PLACE: 4
- OE.USR: 4
- T:
- T.ACCESS: 2
- T.HDDACCESS: 2
- T.IMPADMIN: 2
|
|
pdf_data/st_keywords/vendor |
|
|
pdf_data/st_keywords/eval_facility |
|
|
pdf_data/st_keywords/symmetric_crypto |
|
- AES_competition:
- constructions:
|
pdf_data/st_keywords/asymmetric_crypto |
|
|
pdf_data/st_keywords/pq_crypto |
|
|
pdf_data/st_keywords/hash_function |
|
- JH:
- SHA:
- SHA2:
- SHA-256: 3
- SHA-384: 2
- SHA256: 1
|
pdf_data/st_keywords/crypto_scheme |
|
|
pdf_data/st_keywords/crypto_protocol |
|
|
pdf_data/st_keywords/randomness |
|
|
pdf_data/st_keywords/cipher_mode |
|
|
pdf_data/st_keywords/ecc_curve |
|
- NIST:
- NIST P-256: 1
- NIST P-384: 1
- P-256: 1
- P-384: 1
|
pdf_data/st_keywords/crypto_engine |
|
|
pdf_data/st_keywords/tls_cipher_suite |
|
- TLS:
- TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256: 6
- TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256: 4
- TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384: 6
- TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384: 4
|
pdf_data/st_keywords/crypto_library |
|
|
pdf_data/st_keywords/vulnerability |
|
|
pdf_data/st_keywords/side_channel_analysis |
|
- FI:
- malfunction: 3
- physical tampering: 2
|
pdf_data/st_keywords/technical_report_id |
|
- BSI:
- BSI 7586: 1
- BSI TR-02102-2: 1
- BSI TR-03109: 1
- BSI TR-03109-1: 8
- BSI TR-03109-2: 1
- BSI TR-03109-3: 1
- BSI TR-03109-4: 1
- BSI TR-03111: 1
- BSI TR-03116-3: 1
- BSI TR-03116-4: 1
|
pdf_data/st_keywords/device_model |
|
|
pdf_data/st_keywords/tee_name |
|
|
pdf_data/st_keywords/os_name |
|
|
pdf_data/st_keywords/cplc_data |
|
|
pdf_data/st_keywords/ic_data_group |
|
|
pdf_data/st_keywords/standard_id |
- CC:
- CCIMB-99-031: 2
- CCIMB-99-032: 2
- CCIMB-99-033: 2
- ISO:
|
- BSI:
- FIPS:
- FIPS 140-2: 1
- FIPS 180-4: 3
- FIPS 197: 6
- RFC:
- RFC 2104: 4
- RFC 4493: 5
- RFC 5084: 3
- RFC 5246: 4
- RFC 5289: 4
- RFC 5652: 1
- RFC 5905: 3
- RFC5246: 2
- RFC5905: 1
|
pdf_data/st_keywords/javacard_version |
|
|
pdf_data/st_keywords/javacard_api_const |
|
- curves:
- SECP256R1: 1
- SECP384R1: 1
|
pdf_data/st_keywords/javacard_packages |
|
|
pdf_data/st_keywords/certification_process |
|
|
pdf_data/st_metadata |
- /CreationDate: D:20050713110304+09'00'
- /ModDate: D:20050713110304+09'00'
- /Producer: Acrobat Distiller 6.0.1 (Windows)
- /Title: untitled
- pdf_file_size_bytes: 342087
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 90
|
- /Author: Dr. Neuhaus Telekommunikation
- /CreationDate: D:20210203170405+01'00'
- /Creator: Microsoft® Office Word 2007
- /Keywords: Smart Meter System,Gateway,Common Criteria,Smart Meter Gateway PP
- /ModDate: D:20210203170405+01'00'
- /Producer: Microsoft® Office Word 2007
- /Subject: Schutzprofil für die Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen
- /Title: Protection Profile for the Gateway of a Smart Metering System (Smart Meter Gateway PP)
- pdf_file_size_bytes: 1662000
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 111
|
state/cert/convert_garbage |
False |
False |
state/cert/convert_ok |
False |
True |
state/cert/download_ok |
False |
True |
state/cert/extract_ok |
False |
True |
state/cert/pdf_hash |
Different |
Different |
state/cert/txt_hash |
Different |
Different |
state/report/convert_garbage |
False |
False |
state/report/convert_ok |
True |
True |
state/report/download_ok |
True |
True |
state/report/extract_ok |
True |
True |
state/report/pdf_hash |
Different |
Different |
state/report/txt_hash |
Different |
Different |
state/st/convert_garbage |
False |
False |
state/st/convert_ok |
True |
True |
state/st/download_ok |
True |
True |
state/st/extract_ok |
True |
True |
state/st/pdf_hash |
Different |
Different |
state/st/txt_hash |
Different |
Different |