name |
Secure Smart Card Controller E201382 |
SMARTY IQ-GPRS / LTE, Version 1.4 |
category |
ICs, Smart Cards and Smart Card-Related Devices and Systems |
Other Devices and Systems |
scheme |
FR |
DE |
status |
archived |
active |
not_valid_after |
01.03.2021 |
19.12.2032 |
not_valid_before |
29.02.2016 |
20.12.2024 |
cert_link |
|
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6c_pdf.pdf |
report_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI-CC-2016_08fr.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6a_pdf.pdf |
st_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/ANSSI_cible2016_08en.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6b_pdf.pdf |
manufacturer |
NXP Semiconductors |
Sagemcom Dr. Neuhaus GmbH |
manufacturer_web |
https://www.nxp.com/ |
https://sagemcom.com |
security_level |
EAL5+, ASE_TSS.2, ALC_DVS.2, AVA_VAN.5 |
EAL4+, ALC_FLR.2, AVA_VAN.5 |
dgst |
9ea0321b93567d1e |
4b7dcf610d994944 |
heuristics/cert_id |
ANSSI-CC-2016/08 |
BSI-DSZ-CC-0822-V6-2024 |
heuristics/cert_lab |
SERMA |
BSI |
heuristics/cpe_matches |
{} |
{} |
heuristics/verified_cpe_matches |
{} |
{} |
heuristics/related_cves |
{} |
{} |
heuristics/direct_transitive_cves |
{} |
{} |
heuristics/indirect_transitive_cves |
{} |
{} |
heuristics/extracted_sars |
ASE_INT.1, ALC_DVS.2, ALC_CMC.4, ASE_ECD.1, ADV_IMP.1, ATE_COV.2, ASE_SPD.1, ALC_CMS.5, AVA_VAN.5, ALC_DEL.1, ALC_LCD.1, ADV_FSP.5, AGD_OPE.1, ADV_INT.2, AGD_PRE.1, ATE_FUN.1, ATE_DPT.3, ADV_ARC.1, ASE_OBJ.2, ADV_TDS.4, ASE_TSS.2, ALC_TAT.2, ASE_REQ.2, ATE_IND.2, ASE_CCL.1 |
ATE_COV.2, ASE_TSS.1, ASE_INT.1, ATE_FUN.1, AVA_VAN.5, ALC_DEL.1, ALC_LCD.1, ADV_ARC.1, AGD_OPE.1, ASE_REQ.2, ASE_CCL.1, ALC_CMC.4, ALC_FLR.2, ADV_IMP.1 |
heuristics/extracted_versions |
- |
1.4 |
heuristics/prev_certificates |
{} |
{} |
heuristics/next_certificates |
{} |
{} |
heuristics/report_references/directly_referenced_by |
ANSSI-CC-2016/32 |
{} |
heuristics/report_references/directly_referencing |
{} |
BSI-DSZ-CC-0822-V5-2023 |
heuristics/report_references/indirectly_referenced_by |
ANSSI-CC-2016/32 |
{} |
heuristics/report_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0822-V2-2020, BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0822-V3-2021, BSI-DSZ-CC-0822-V5-2023 |
heuristics/scheme_data |
|
- category: Intelligent measuring systems
- cert_id: BSI-DSZ-CC-0822-V6-2024
- certification_date: 20.12.2024
- enhanced:
- applicant: Sagemcom Dr. Neuhaus GmbH Papenreye 65 22453 Hamburg
- assurance_level: EAL4+,AVA_VAN.5,ALC_FLR.2
- cert_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6c_pdf.pdf?__blob=publicationFile&v=2
- certification_date: 20.12.2024
- entries: [frozendict({'id': 'BSI-DSZ-CC-0822-V6-2024', 'description': 'The focus of this recertification was on the introduction of a new LTE-Modul for WAN-communication, the GWA-change process implementation following FNN requirements and the introduction of proxy-profiles and communication scenario HKS3 with SOCKSv5.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V5-2023', 'description': 'components.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V4-2023', 'description': 'The focus of this recertification was on the update of the operating system and some libraries, the implementation of changed and added tariff use cases (TAF 2, TAF 9, TAF 10, TAF 14), the support of IPv6 and the support of firmware download.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-RA-02', 'description': 'The CC-certificate BSI-DSZ-CC-0822-V3-2021 remains valid for 2 further years.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-RA-01', 'description': 'Successful Re-Assessment with update of the vulnerability analysis.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-MA-02', 'description': 'Security Target'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-MA-01', 'description': 'version number remains the same as the alternative components have the same behaviour as the original one.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021', 'description': 'The previoulsly certified TOE was changed and re-certified to implement minor security-relevant optimizations.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V2-2020', 'description': 'Certificate'}), frozendict({'id': 'BSI-DSZ-CC-0822-2019-MA-01 (20.11.2019)', 'description': 'Certificate invalid'}), frozendict({'id': 'BSI-DSZ-CC-0822-2019 (25.09.2019)', 'description': 'Certificate invalid'})]
- evaluation_facility: TÜV Informationstechnik GmbH
- expiration_date: 19.12.2032
- product: SMARTY IQ-LTE, Version 1.4
- protection_profile: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI-CC-PP-0073-2014
- report_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6a_pdf.pdf?__blob=publicationFile&v=2
- target_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6b_pdf.html?nn=456626
- product: SMARTY IQ-LTE, Version 1.4
- subcategory: (Smart Meter Gateway)
- url: https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_Gateway/0822_0822V2_0822V3_0822V4_0822V5_0822V6.html
- vendor: Sagemcom Dr. Neuhaus GmbH
|
heuristics/st_references/directly_referenced_by |
{} |
{} |
heuristics/st_references/directly_referencing |
{} |
BSI-DSZ-CC-0957-V2-2016 |
heuristics/st_references/indirectly_referenced_by |
{} |
{} |
heuristics/st_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0957-V2-2016, BSI-DSZ-CC-0978-2016 |
heuristics/protection_profiles |
cf0f01bcd7be3e9c |
6346b04de6859db3 |
maintenance_updates |
|
|
protection_profiles |
|
|
protection_profile_links |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0084b_pdf.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073b_pdf.pdf |
pdf_data/cert_filename |
|
0822V6c_pdf.pdf |
pdf_data/cert_frontpage |
|
|
pdf_data/cert_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0822-V6-2024: 1
|
pdf_data/cert_keywords/cc_protection_profile_id |
|
|
pdf_data/cert_keywords/cc_security_level |
|
- EAL:
- EAL 2: 1
- EAL 4: 2
- EAL 4 augmented: 1
- EAL 5: 1
|
pdf_data/cert_keywords/cc_sar |
|
|
pdf_data/cert_keywords/cc_sfr |
|
|
pdf_data/cert_keywords/cc_claims |
|
|
pdf_data/cert_keywords/vendor |
|
|
pdf_data/cert_keywords/eval_facility |
|
|
pdf_data/cert_keywords/symmetric_crypto |
|
|
pdf_data/cert_keywords/asymmetric_crypto |
|
|
pdf_data/cert_keywords/pq_crypto |
|
|
pdf_data/cert_keywords/hash_function |
|
|
pdf_data/cert_keywords/crypto_scheme |
|
|
pdf_data/cert_keywords/crypto_protocol |
|
|
pdf_data/cert_keywords/randomness |
|
|
pdf_data/cert_keywords/cipher_mode |
|
|
pdf_data/cert_keywords/ecc_curve |
|
|
pdf_data/cert_keywords/crypto_engine |
|
|
pdf_data/cert_keywords/tls_cipher_suite |
|
|
pdf_data/cert_keywords/crypto_library |
|
|
pdf_data/cert_keywords/vulnerability |
|
|
pdf_data/cert_keywords/side_channel_analysis |
|
|
pdf_data/cert_keywords/technical_report_id |
|
|
pdf_data/cert_keywords/device_model |
|
|
pdf_data/cert_keywords/tee_name |
|
|
pdf_data/cert_keywords/os_name |
|
|
pdf_data/cert_keywords/cplc_data |
|
|
pdf_data/cert_keywords/ic_data_group |
|
|
pdf_data/cert_keywords/standard_id |
|
- ISO:
- ISO/IEC 15408: 2
- ISO/IEC 18045: 2
|
pdf_data/cert_keywords/javacard_version |
|
|
pdf_data/cert_keywords/javacard_api_const |
|
|
pdf_data/cert_keywords/javacard_packages |
|
|
pdf_data/cert_keywords/certification_process |
|
|
pdf_data/cert_metadata |
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid"
- /Subject: Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid
- /Title: Certificate BSI-DSZ-CC-0822-V6-2024
- pdf_file_size_bytes: 335622
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
pdf_data/report_filename |
ANSSI-CC-2016_08fr.pdf |
0822V6a_pdf.pdf |
pdf_data/report_frontpage |
- FR:
- cc_security_level: EAL 5 augmenté ALC_DVS.2, AVA_VAN.5, ASE_TSS.2
- cc_version: Critères Communs version 3.1 révision 4
- cert_id: ANSSI-CC-2016/08
- cert_item: Secure Smart Card Controller E201382
- cert_item_version: IC Hardware versions VA and VB, ID Dedicated Support Software version 1.0
- cert_lab: Serma Safety & Technology 14 rue Galilée, CS 10055, 33615 Pessac Cedex, France
- developer: NXP Semiconductors Stresemannallee 101 22529 Hamburg, GERMANY Commanditaire NXP Semiconductors Stresemannallee 101 22529 Hamburg, GERMANY
- match_rules: ['Référence du rapport de certification(.+)Nom du produit(.+)Référence/version du produit(.+)Conformité à un profil de protection(.+)Critères d’évaluation et version(.+)Niveau d’évaluation(.+)Développeur (.+)Centre d’évaluation(.+)Accords de reconnaissance applicables']
- ref_protection_profiles: Security IC Platform Protection Profile with Augmentation Packages, version 1.0, certifié BSI-CC-PP-0084-2014 le 19 february 2014 avec conformité à “Package 1: Loader dedicated for usage in Secured Environment only
- DE:
|
- FR:
- DE:
- cc_security_level: Common Criteria Part 3 conformant EAL 4 augmented by ALC_FLR.2 and AVA_VAN.5 valid until: 19 December 2032
- cc_version: PP conformant Common Criteria Part 2 extended
- cert_id: BSI-DSZ-CC-0822-V6-2024
- cert_item: SMARTY IQ-LTE, Version 1.4
- cert_lab: BSI
- developer: Sagemcom Dr. Neuhaus GmbH
- match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
- ref_protection_profiles: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014
|
pdf_data/report_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0822-V5-2023: 3
- BSI-DSZ-CC-0822-V6-2024: 14
- BSI-DSZ-CC-0957-: 1
|
pdf_data/report_keywords/cc_protection_profile_id |
- BSI:
- BSI-CC-PP- 0084-2014: 1
- BSI-CC-PP-0084-2014: 1
|
- BSI:
- BSI-CC-PP-0073-2014: 3
- BSI-CC-PP-0077-V2-2015: 2
|
pdf_data/report_keywords/cc_security_level |
- EAL:
- EAL 1: 1
- EAL 3: 1
- EAL 5: 3
- EAL 7: 1
- EAL2: 2
- EAL7: 1
- ITSEC:
|
- EAL:
- EAL 1: 1
- EAL 2: 3
- EAL 4: 8
- EAL 4 augmented: 3
- EAL 5: 3
- EAL 5+: 1
- EAL 6: 1
|
pdf_data/report_keywords/cc_sar |
- ADV:
- ADV_ARC: 1
- ADV_FSP: 1
- ADV_IMP: 1
- ADV_INT: 1
- ADV_SPM: 1
- ADV_TDS: 1
- AGD:
- ALC:
- ALC_CMC: 1
- ALC_CMS: 1
- ALC_DEL: 1
- ALC_DVS: 1
- ALC_DVS.2: 2
- ALC_FLR: 2
- ALC_TAT: 1
- ASE:
- ASE_CCL: 1
- ASE_ECD: 1
- ASE_INT: 1
- ASE_OBJ: 1
- ASE_REQ: 1
- ASE_SPD: 1
- ASE_TSS: 1
- ASE_TSS.2: 2
- ATE:
- ATE_COV: 1
- ATE_DPT: 1
- ATE_FUN: 1
- ATE_IND: 1
- AVA:
|
|
pdf_data/report_keywords/cc_sfr |
|
|
pdf_data/report_keywords/cc_claims |
|
|
pdf_data/report_keywords/vendor |
- NXP:
- NXP: 19
- NXP Semiconductors: 2
|
|
pdf_data/report_keywords/eval_facility |
|
- TUV:
- TÜV Informationstechnik: 3
|
pdf_data/report_keywords/symmetric_crypto |
|
- AES_competition:
- constructions:
|
pdf_data/report_keywords/asymmetric_crypto |
|
|
pdf_data/report_keywords/pq_crypto |
|
|
pdf_data/report_keywords/hash_function |
|
|
pdf_data/report_keywords/crypto_scheme |
|
|
pdf_data/report_keywords/crypto_protocol |
|
|
pdf_data/report_keywords/randomness |
|
|
pdf_data/report_keywords/cipher_mode |
|
|
pdf_data/report_keywords/ecc_curve |
|
|
pdf_data/report_keywords/crypto_engine |
|
|
pdf_data/report_keywords/tls_cipher_suite |
|
|
pdf_data/report_keywords/crypto_library |
|
|
pdf_data/report_keywords/vulnerability |
|
|
pdf_data/report_keywords/side_channel_analysis |
|
|
pdf_data/report_keywords/technical_report_id |
|
- BSI:
- BSI 7148: 1
- BSI TR-03109: 1
- BSI TR-03116: 1
|
pdf_data/report_keywords/device_model |
|
|
pdf_data/report_keywords/tee_name |
|
|
pdf_data/report_keywords/os_name |
|
|
pdf_data/report_keywords/cplc_data |
|
|
pdf_data/report_keywords/ic_data_group |
|
|
pdf_data/report_keywords/standard_id |
- CC:
- CCMB-2012-09-001: 1
- CCMB-2012-09-002: 1
- CCMB-2012-09-003: 1
- CCMB-2012-09-004: 1
|
- BSI:
- AIS 32: 1
- AIS 34: 2
- AIS 38: 1
- AIS 46: 2
- AIS 48: 1
- FIPS:
- FIPS 186-4: 1
- FIPS PUB 180-4: 1
- FIPS PUB 186: 1
- FIPS180-4: 3
- ISO:
- ISO/IEC 15408: 4
- ISO/IEC 17065: 2
- ISO/IEC 18045: 4
- RFC:
- RFC 2104: 1
- RFC 5246: 1
- RFC 5639: 1
- RFC 5652: 1
- RFC 8289: 1
- RFC 8422: 1
- RFC2104: 2
- RFC4493: 6
- RFC5084: 2
- RFC5246: 6
- RFC5288: 2
- RFC5289: 3
- RFC5639: 6
- RFC5652: 4
- RFC6033: 2
- RFC6090: 4
- RFC6161: 2
- RFC8422: 2
|
pdf_data/report_keywords/javacard_version |
|
|
pdf_data/report_keywords/javacard_api_const |
|
|
pdf_data/report_keywords/javacard_packages |
|
|
pdf_data/report_keywords/certification_process |
|
- ConfidentialDocument:
- 23 / 27 Certification Report BSI-DSZ-CC-0822-V6-2024 [9] Configuration list for the TOE (confidential documents): filelist_OS, 2024-11-12 filelist_sln8209, 2024-11-12 8209SE011_SMGw_CPU_USB, Version 3.3: 1
- Technical Report BSI-DSZ-CC-0822-V6, Version 1, 2024-11-15, TÜV Informationstechnik GmbH, (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014: 1
- being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
|
pdf_data/report_metadata |
- /Author: Coralie
- /CreationDate: D:20160303092000+01'00'
- /Creator: Microsoft® Word 2010
- /Keywords: ANSSI-CC-CER-F-07.017
- /ModDate: D:20160303092000+01'00'
- /Producer: Microsoft® Word 2010
- /Subject: Secure Smart Card Controller E201382
- /Title: ANSSI-CC-2016/08
- pdf_file_size_bytes: 549301
- pdf_hyperlinks: http://www.ssi.gouv.fr/, mailto:[email protected]
- pdf_is_encrypted: False
- pdf_number_of_pages: 14
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid"
- /Subject: Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid
- /Title: Certification Report BSI-DSZ-CC-0822-V6-2024
- pdf_file_size_bytes: 661868
- pdf_hyperlinks: http://www.commoncriteriaportal.org/cc/, https://www.sogis.eu/, https://www.bsi.bund.de/AIS, http://www.commoncriteriaportal.org/, https://www.commoncriteriaportal.org/, https://www.bsi.bund.de/zertifizierung, https://www.bsi.bund.de/zertifizierungsreporte, https://www.bsi.bund.de/
- pdf_is_encrypted: False
- pdf_number_of_pages: 27
|
pdf_data/st_filename |
ANSSI_cible2016_08en.pdf |
0822V6b_pdf.pdf |
pdf_data/st_frontpage |
|
|
pdf_data/st_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0957-V2-2016: 1
|
pdf_data/st_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073: 4
- BSI-CC-PP-0077-2013: 1
|
pdf_data/st_keywords/cc_security_level |
- EAL:
- EAL4: 3
- EAL4+: 1
- EAL5: 11
- EAL5 augmented: 2
|
- EAL:
- EAL 4: 5
- EAL 4 augmented: 2
- EAL4: 1
- EAL4 augmented: 1
|
pdf_data/st_keywords/cc_sar |
- ADV:
- ADV_ARC: 1
- ADV_ARC.1: 1
- ADV_FSP: 3
- ADV_FSP.4: 3
- ADV_FSP.5: 11
- ADV_IMP: 1
- ADV_IMP.1: 1
- ADV_INT.2: 1
- ADV_TDS.4: 1
- AGD:
- AGD_OPE: 1
- AGD_OPE.1: 1
- AGD_PRE: 1
- AGD_PRE.1: 1
- ALC:
- ALC_CMC: 1
- ALC_CMC.4: 1
- ALC_CMS: 3
- ALC_CMS.4: 3
- ALC_CMS.5: 5
- ALC_DEL: 1
- ALC_DEL.1: 1
- ALC_DVS: 1
- ALC_DVS.2: 2
- ALC_LCD.1: 1
- ALC_TAT.2: 1
- ASE:
- ASE_CCL.1: 1
- ASE_ECD.1: 1
- ASE_INT.1: 1
- ASE_OBJ.2: 1
- ASE_REQ.2: 1
- ASE_SPD.1: 1
- ASE_TSS.2: 4
- ATE:
- ATE_COV: 1
- ATE_COV.2: 1
- ATE_DPT.3: 1
- ATE_FUN.1: 1
- ATE_IND.2: 1
- AVA:
|
- ADV:
- ADV_ARC.1: 1
- ADV_IMP.1: 1
- AGD:
- ALC:
- ALC_CMC.4: 1
- ALC_DEL.1: 1
- ALC_FLR.2: 6
- ALC_LCD.1: 1
- ASE:
- ASE_CCL.1: 1
- ASE_INT.1: 1
- ASE_REQ.2: 1
- ASE_TSS.1: 1
- ATE:
- ATE_COV.2: 1
- ATE_FUN.1: 1
- AVA:
|
pdf_data/st_keywords/cc_sfr |
- FAU:
- FAU_SAS.1: 7
- FAU_SAS.1.1: 1
- FCS:
- FCS_CKM.1: 9
- FCS_CKM.4: 9
- FCS_COP.1: 47
- FCS_COP.1.1: 4
- FCS_RNG.1: 17
- FCS_RNG.1.1: 4
- FCS_RNG.1.2: 3
- FDP:
- FDP_ACC.1: 32
- FDP_ACC.1.1: 2
- FDP_ACF.1: 23
- FDP_ACF.1.1: 2
- FDP_ACF.1.2: 2
- FDP_ACF.1.3: 2
- FDP_ACF.1.4: 2
- FDP_IFC.1: 13
- FDP_ITC.1: 9
- FDP_ITC.2: 9
- FDP_ITT.1: 9
- FDP_ITT.1.1: 1
- FDP_RIP.1: 13
- FDP_RIP.1.1: 2
- FDP_SDC.1: 7
- FDP_SDC.1.1: 1
- FDP_SDI.1: 1
- FDP_SDI.2: 8
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FMT:
- FMT_LIM.1: 15
- FMT_LIM.1.1: 1
- FMT_LIM.2: 17
- FMT_LIM.2.1: 1
- FMT_MSA.1: 23
- FMT_MSA.1.1: 2
- FMT_MSA.3: 20
- FMT_MSA.3.1: 2
- FMT_MSA.3.2: 2
- FMT_SMF.1: 25
- FMT_SMF.1.1: 2
- FMT_SMR.1: 13
- FPT:
- FPT_FLS.1: 9
- FPT_ITT.1: 11
- FPT_ITT.1.1: 1
- FPT_PHP.3: 8
- FPT_TST.1: 7
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FRU:
|
- FAU:
- FAU_ARP: 10
- FAU_ARP.1: 1
- FAU_CON.1.2: 1
- FAU_GEN: 39
- FAU_GEN.1: 17
- FAU_GEN.2: 10
- FAU_GEN.2.1: 1
- FAU_SAA: 15
- FAU_SAA.1: 4
- FAU_SAR: 30
- FAU_SAR.1: 6
- FAU_STG: 34
- FAU_STG.1: 8
- FAU_STG.2: 10
- FAU_STG.2.1: 1
- FAU_STG.2.2: 1
- FAU_STG.2.3: 1
- FAU_STG.3: 3
- FAU_STG.4: 3
- FCO:
- FCO_NRO: 3
- FCO_NRO.1: 1
- FCO_NRO.2: 11
- FCO_NRO.2.1: 1
- FCO_NRO.2.2: 1
- FCO_NRO.2.3: 1
- FCS:
- FCS_CKM: 51
- FCS_CKM.1: 16
- FCS_CKM.2: 6
- FCS_CKM.4: 30
- FCS_CKM.4.1: 1
- FCS_COP: 68
- FCS_COP.1: 11
- FDP:
- FDP_ACC: 2
- FDP_ACC.1: 9
- FDP_ACC.2: 12
- FDP_ACC.2.1: 1
- FDP_ACC.2.2: 1
- FDP_ACF: 1
- FDP_ACF.1: 11
- FDP_ACF.1.1: 1
- FDP_ACF.1.2: 1
- FDP_ACF.1.3: 1
- FDP_ACF.1.4: 1
- FDP_IFC: 29
- FDP_IFC.1: 12
- FDP_IFC.2: 4
- FDP_IFF: 26
- FDP_IFF.1: 18
- FDP_ITC.1: 12
- FDP_ITC.2: 12
- FDP_RIP: 2
- FDP_RIP.1: 1
- FDP_RIP.2: 8
- FDP_RIP.2.1: 1
- FDP_SDI: 2
- FDP_SDI.1: 1
- FDP_SDI.2: 9
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FIA:
- FIA_AFL: 3
- FIA_AFL.1: 10
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_ATD: 3
- FIA_ATD.1: 13
- FIA_ATD.1.1: 1
- FIA_UAU: 5
- FIA_UAU.1: 2
- FIA_UAU.2: 9
- FIA_UAU.2.1: 1
- FIA_UAU.5: 9
- FIA_UAU.5.1: 1
- FIA_UAU.5.2: 1
- FIA_UAU.6: 10
- FIA_UAU.6.1: 1
- FIA_UID: 3
- FIA_UID.1: 8
- FIA_UID.2: 14
- FIA_UID.2.1: 1
- FIA_USB: 3
- FIA_USB.1: 9
- FIA_USB.1.1: 1
- FIA_USB.1.2: 1
- FIA_USB.1.3: 1
- FMT:
- FMT_MOF: 1
- FMT_MOF.1: 9
- FMT_MOF.1.1: 1
- FMT_MSA: 64
- FMT_MSA.1: 9
- FMT_MSA.3: 12
- FMT_SMF: 2
- FMT_SMF.1: 19
- FMT_SMF.1.1: 1
- FMT_SMR: 3
- FMT_SMR.1: 29
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPR:
- FPR_CON: 6
- FPR_CON.1: 12
- FPR_CON.1.1: 3
- FPR_CON.1.2: 3
- FPR_PSE: 3
- FPR_PSE.1: 9
- FPR_PSE.1.1: 1
- FPR_PSE.1.2: 1
- FPR_PSE.1.3: 1
- FPT:
- FPT_FLS: 3
- FPT_FLS.1: 9
- FPT_FLS.1.1: 2
- FPT_PHP: 3
- FPT_PHP.1: 8
- FPT_PHP.1.1: 1
- FPT_PHP.1.2: 1
- FPT_RPL: 3
- FPT_RPL.1: 10
- FPT_RPL.1.1: 1
- FPT_RPL.1.2: 1
- FPT_STM: 3
- FPT_STM.1: 20
- FPT_STM.1.1: 1
- FPT_TST: 3
- FPT_TST.1: 10
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FTP:
|
pdf_data/st_keywords/cc_claims |
- O:
- O.AES: 5
- O.DES: 4
- O.HW_REUSE: 5
- O.INTEGRITY_CHK: 4
- O.MEM_ACCESS: 5
- O.NVM_INTEGRITY: 5
- O.REUSE: 6
- O.RND: 4
- O.SFR_ACCESS: 4
- T:
|
|
pdf_data/st_keywords/vendor |
- NXP:
- NXP: 22
- NXP Semiconductors: 30
|
|
pdf_data/st_keywords/eval_facility |
|
|
pdf_data/st_keywords/symmetric_crypto |
- AES_competition:
- DES:
- 3DES:
- 3DES: 2
- TDEA: 1
- TDES: 6
- Triple-DES: 7
- DES:
- constructions:
|
- AES_competition:
- constructions:
|
pdf_data/st_keywords/asymmetric_crypto |
|
|
pdf_data/st_keywords/pq_crypto |
|
|
pdf_data/st_keywords/hash_function |
|
- JH:
- SHA:
- SHA2:
- SHA-256: 3
- SHA-384: 2
- SHA256: 1
|
pdf_data/st_keywords/crypto_scheme |
|
|
pdf_data/st_keywords/crypto_protocol |
|
|
pdf_data/st_keywords/randomness |
|
|
pdf_data/st_keywords/cipher_mode |
|
|
pdf_data/st_keywords/ecc_curve |
|
- NIST:
- NIST P-256: 2
- NIST P-384: 1
- P-256: 2
- P-384: 1
|
pdf_data/st_keywords/crypto_engine |
|
|
pdf_data/st_keywords/tls_cipher_suite |
|
- TLS:
- TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256: 2
- TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256: 2
- TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384: 2
- TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384: 2
|
pdf_data/st_keywords/crypto_library |
|
|
pdf_data/st_keywords/vulnerability |
|
|
pdf_data/st_keywords/side_channel_analysis |
- FI:
- Malfunction: 7
- malfunction: 3
- physical tampering: 1
- SCA:
- DPA: 1
- Leak-Inherent: 9
- Physical Probing: 2
- physical probing: 1
- side channel: 3
- other:
|
- FI:
- malfunction: 3
- physical tampering: 2
|
pdf_data/st_keywords/technical_report_id |
|
- BSI:
- BSI 7586: 1
- BSI TR-02102-2: 1
- BSI TR-03109: 1
- BSI TR-03109-1: 9
- BSI TR-03109-2: 1
- BSI TR-03109-3: 1
- BSI TR-03109-4: 1
- BSI TR-03111: 1
- BSI TR-03116-3: 1
- BSI TR-03116-4: 1
|
pdf_data/st_keywords/device_model |
|
|
pdf_data/st_keywords/tee_name |
|
|
pdf_data/st_keywords/os_name |
|
|
pdf_data/st_keywords/cplc_data |
|
|
pdf_data/st_keywords/ic_data_group |
|
|
pdf_data/st_keywords/standard_id |
- BSI:
- CC:
- CCMB-2012-09-001: 2
- CCMB-2012-09-002: 2
- CCMB-2012-09-003: 2
- CCMB-2012-09-004: 2
- FIPS:
- FIPS PUB 197: 1
- FIPS PUB 46-3: 2
- ISO:
- ISO/IEC 14443: 2
- ISO/IEC 14443-3: 1
- ISO/IEC 14443-4: 2
|
- BSI:
- FIPS:
- FIPS 140-2: 1
- FIPS 180-4: 3
- FIPS 197: 6
- RFC:
- RFC 2104: 4
- RFC 4493: 5
- RFC 5084: 3
- RFC 5246: 4
- RFC 5289: 4
- RFC 5652: 1
- RFC 5905: 3
- RFC5246: 2
- RFC5905: 1
|
pdf_data/st_keywords/javacard_version |
|
|
pdf_data/st_keywords/javacard_api_const |
|
- curves:
- SECP256R1: 2
- SECP384R1: 1
|
pdf_data/st_keywords/javacard_packages |
|
|
pdf_data/st_keywords/certification_process |
|
|
pdf_data/st_metadata |
|
- /Author: Federal Office for Information Security
- /Keywords: Smart Meter System, Gateway, Common Criteria, Smart Meter Gateway PP
- /Subject: Schutzprofil für die Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen
- /Title: Sagemcom Dr. Neuhaus SMARTY IQ-LTE Security Target
- pdf_file_size_bytes: 2020364
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 112
|
state/cert/convert_garbage |
False |
False |
state/cert/convert_ok |
False |
True |
state/cert/download_ok |
False |
True |
state/cert/extract_ok |
False |
True |
state/cert/pdf_hash |
Different |
Different |
state/cert/txt_hash |
Different |
Different |
state/report/convert_garbage |
False |
False |
state/report/convert_ok |
True |
True |
state/report/download_ok |
True |
True |
state/report/extract_ok |
True |
True |
state/report/pdf_hash |
Different |
Different |
state/report/txt_hash |
Different |
Different |
state/st/convert_garbage |
False |
False |
state/st/convert_ok |
True |
True |
state/st/download_ok |
True |
True |
state/st/extract_ok |
True |
True |
state/st/pdf_hash |
Different |
Different |
state/st/txt_hash |
Different |
Different |