name |
Cisco IoT Industrial Ethernet and Connected Grid Switches running IOS 15.2 |
ZEMO VML-GK2 HW V2.0.0 / FW V3.2.0 |
category |
Network and Network-Related Devices and Systems |
Other Devices and Systems |
scheme |
US |
DE |
status |
archived |
active |
not_valid_after |
29.11.2020 |
07.05.2029 |
not_valid_before |
29.11.2018 |
08.05.2024 |
cert_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/st_vid10907-ci.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0623V3c_pdf.pdf |
report_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/st_vid10907-vr.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0623V3a_pdf.pdf |
st_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/st_vid10907-st.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0623V3b_pdf.pdf |
manufacturer |
Cisco Systems, Inc. |
ZEMO GmbH |
manufacturer_web |
https://www.cisco.com |
https://zemo.de |
security_level |
{} |
ADV_FSP.4, ALC_TAT.1, AVA_VAN.5, ADV_IMP.1, EAL3+, ADV_TDS.3 |
dgst |
7e93f6adbb25a3b5 |
d648123b397e3e21 |
heuristics/cert_id |
CCEVS-VR-10907-2018 |
BSI-DSZ-CC-0623-V3-2024 |
heuristics/cert_lab |
US |
BSI |
heuristics/cpe_matches |
{} |
{} |
heuristics/verified_cpe_matches |
{} |
{} |
heuristics/related_cves |
{} |
{} |
heuristics/direct_transitive_cves |
{} |
{} |
heuristics/indirect_transitive_cves |
{} |
{} |
heuristics/extracted_sars |
ADV_FSP.1, ALC_CMC.1, AVA_VAN.1, ATE_IND.1, ALC_CMS.1, AGD_OPE.1, AGD_PRE.1 |
AGD_PRE.1, ALC_DVS.1, ATE_COV.2, ALC_TAT.1, ATE_FUN.1, AVA_VAN.5, ALC_DEL.1, ATE_IND.2, ADV_FSP.4, ALC_LCD.1, ADV_ARC.1, AGD_OPE.1, ADV_TDS.3, ALC_CMC.3, ATE_DPT.1, ALC_CMS.3, ADV_IMP.1 |
heuristics/extracted_versions |
15.2 |
2.0.0, 3.2.0 |
heuristics/prev_certificates |
{} |
{} |
heuristics/next_certificates |
{} |
{} |
heuristics/report_references/directly_referenced_by |
{} |
{} |
heuristics/report_references/directly_referencing |
{} |
{} |
heuristics/report_references/indirectly_referenced_by |
{} |
{} |
heuristics/report_references/indirectly_referencing |
{} |
{} |
heuristics/scheme_data |
- category: Network Device
- certification_date: 29.11.2018
- evaluation_facility: Gossamer Security Solutions
- expiration_date: 29.11.2020
- id: CCEVS-VR-VID10907
- product: Cisco IoT Industrial Ethernet and Connected Grid Switches running IOS 15.2
- scheme: US
- url: https://www.niap-ccevs.org/product/10907
- vendor: Cisco Systems, Inc.
|
- category: eHealth
- cert_id: BSI-DSZ-CC-0623-V3-2024
- certification_date: 08.05.2024
- enhanced:
- applicant: ZEMO GmbH Franz-Mader-Straße 9 94036 Passau
- assurance_level: EAL3,AVA_VAN.5,ALC_TAT.1,ADV_TDS.3,ADV_IMP.1,ADV_FSP.4
- cert_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte06/0623V3c_pdf.pdf?__blob=publicationFile&v=2
- certification_date: 08.05.2024
- description: The Target of Evaluation (TOE) is the ZEMO VML-GK2, FW-Version 3.1.0, HW-Version 2.0.0 by ZEMO GmbH. The TOE is a smart card terminal used for the German healthcare system as a Mobile Card Terminal (MobCT). It is used by medical suppliers during visits to read out insurance data from a German electronic Health Card (eHC) of a health insured person. The TOE fulfils the IT security requirements to be used with the German electronic Health Card (eHC) and the German Health Professional Card (HPC) based on the regulations of the German healthcare system.
- entries: [frozendict({'id': 'BSI-DSZ-CC-0623-V3-2024 (08.05.2024)', 'description': 'Certificate'}), frozendict({'id': 'BSI-DSZ-CC-0623-V2-2018 (28.06.2018)', 'description': 'Certificate'})]
- evaluation_facility: TÜV Informationstechnik GmbH
- expiration_date: 07.05.2029
- product: ZEMO VML-GK2
- protection_profile: Common Criteria Protection Profile Mobile Card Terminal for the German Healthcare System (MobCT), Version 1.4, BSI-CC-PP-0052-2015, 19 January 2015
- report_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte06/0623V3a_pdf.pdf?__blob=publicationFile&v=2
- target_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte06/0623V3b_pdf.pdf?__blob=publicationFile&v=2
- product: ZEMO VML-GK2
- subcategory: Card reader
- url: https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/Gesundheitswesen_Kartenlesegeraete/0623.html
- vendor: ZEMO GmbH
|
heuristics/st_references/directly_referenced_by |
{} |
{} |
heuristics/st_references/directly_referencing |
{} |
{} |
heuristics/st_references/indirectly_referenced_by |
{} |
{} |
heuristics/st_references/indirectly_referencing |
{} |
{} |
heuristics/protection_profiles |
48ac4778e4272298 |
854be21fba7a106c |
maintenance_updates |
|
|
protection_profiles |
|
|
protection_profile_links |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/CPP_ND_V2.0E.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0052b_pdf.pdf |
pdf_data/cert_filename |
st_vid10907-ci.pdf |
0623V3c_pdf.pdf |
pdf_data/cert_frontpage |
|
|
pdf_data/cert_keywords/cc_cert_id |
- US:
- CCEVS-VR-VID10907-2018: 1
|
- DE:
- BSI-DSZ-CC-0623-V3-2024: 1
|
pdf_data/cert_keywords/cc_protection_profile_id |
|
|
pdf_data/cert_keywords/cc_security_level |
|
- EAL:
- EAL 2: 1
- EAL 3: 1
- EAL 3 augmented: 1
- EAL 4: 1
|
pdf_data/cert_keywords/cc_sar |
|
- ADV:
- ADV_FSP.4: 1
- ADV_IMP.1: 1
- ADV_TDS.3: 1
- ALC:
- AVA:
|
pdf_data/cert_keywords/cc_sfr |
|
|
pdf_data/cert_keywords/cc_claims |
|
|
pdf_data/cert_keywords/vendor |
- Cisco:
- Cisco: 1
- Cisco Systems, Inc: 1
|
|
pdf_data/cert_keywords/eval_facility |
|
|
pdf_data/cert_keywords/symmetric_crypto |
|
|
pdf_data/cert_keywords/asymmetric_crypto |
|
|
pdf_data/cert_keywords/pq_crypto |
|
|
pdf_data/cert_keywords/hash_function |
|
|
pdf_data/cert_keywords/crypto_scheme |
|
|
pdf_data/cert_keywords/crypto_protocol |
|
|
pdf_data/cert_keywords/randomness |
|
|
pdf_data/cert_keywords/cipher_mode |
|
|
pdf_data/cert_keywords/ecc_curve |
|
|
pdf_data/cert_keywords/crypto_engine |
|
|
pdf_data/cert_keywords/tls_cipher_suite |
|
|
pdf_data/cert_keywords/crypto_library |
|
|
pdf_data/cert_keywords/vulnerability |
|
|
pdf_data/cert_keywords/side_channel_analysis |
|
|
pdf_data/cert_keywords/technical_report_id |
|
|
pdf_data/cert_keywords/device_model |
|
|
pdf_data/cert_keywords/tee_name |
|
|
pdf_data/cert_keywords/os_name |
|
|
pdf_data/cert_keywords/cplc_data |
|
|
pdf_data/cert_keywords/ic_data_group |
|
|
pdf_data/cert_keywords/standard_id |
|
- ISO:
- ISO/IEC 15408: 2
- ISO/IEC 18045: 2
|
pdf_data/cert_keywords/javacard_version |
|
|
pdf_data/cert_keywords/javacard_api_const |
|
|
pdf_data/cert_keywords/javacard_packages |
|
|
pdf_data/cert_keywords/certification_process |
|
|
pdf_data/cert_metadata |
- /CreationDate: D:20181210153145-05'00'
- /ModDate: D:20181210153145-05'00'
- /Producer: iText 2.1.0 (by lowagie.com)
- pdf_file_size_bytes: 180932
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, Mobile Card Terminal for the German Healthcare System (MobCT), BSI-CC-PP-0052-2015"
- /Subject: Common Criteria, Certification, Zertifizierung, Mobile Card Terminal for the German Healthcare System (MobCT), BSI-CC-PP-0052-2015
- /Title: Certification Report BSI-DSZ-CC-0623-V3-2024
- pdf_file_size_bytes: 232618
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
pdf_data/report_filename |
st_vid10907-vr.pdf |
0623V3a_pdf.pdf |
pdf_data/report_frontpage |
- DE:
- US:
- cert_id: CCEVS-VR-10907-2018
- cert_item: Cisco Systems, Inc. IoT Industrial Ethernet and Connected Grid Switches running IOS 15.2
- cert_lab: US NIAP
|
- DE:
- cc_security_level: Common Criteria Part 3 conformant EAL 3 augmented by ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, ALC_TAT.1, AVA_VAN.5 valid until: 7 May 2029
- cc_version: PP conformant Common Criteria Part 2 extended
- cert_id: BSI-DSZ-CC-0623-V3-2024
- cert_item: ZEMO VML-GK2 HW V2.0.0 / FW V3.2.0
- cert_lab: BSI
- developer: ZEMO GmbH
- match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
- ref_protection_profiles: Common Criteria Protection Profile Mobile Card Terminal for the German Healthcare System (MobCT), Version 1.4, BSI-CC-PP-0052-2015, 24 September 2014
- US:
|
pdf_data/report_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0623-V3-2024: 12
|
pdf_data/report_keywords/cc_protection_profile_id |
|
|
pdf_data/report_keywords/cc_security_level |
|
- EAL:
- EAL 1: 1
- EAL 2: 3
- EAL 3: 4
- EAL 3 augmented: 3
- EAL 4: 4
- EAL3+: 1
|
pdf_data/report_keywords/cc_sar |
|
- ADV:
- ADV_FSP.4: 4
- ADV_IMP.1: 4
- ADV_TDS.3: 4
- ALC:
- ATE:
- AVA:
|
pdf_data/report_keywords/cc_sfr |
|
|
pdf_data/report_keywords/cc_claims |
|
- OE:
- OE.ENVIRONMENT: 1
- OE.MEDIC: 1
- OE.PHYSICAL: 1
|
pdf_data/report_keywords/vendor |
- Cisco:
- Cisco: 33
- Cisco Systems, Inc: 4
|
|
pdf_data/report_keywords/eval_facility |
|
- TUV:
- TÜV Informationstechnik: 3
|
pdf_data/report_keywords/symmetric_crypto |
- AES_competition:
- constructions:
|
|
pdf_data/report_keywords/asymmetric_crypto |
|
|
pdf_data/report_keywords/pq_crypto |
|
|
pdf_data/report_keywords/hash_function |
|
|
pdf_data/report_keywords/crypto_scheme |
- KEX:
- Key Exchange: 1
- Key exchange: 1
|
|
pdf_data/report_keywords/crypto_protocol |
|
|
pdf_data/report_keywords/randomness |
|
|
pdf_data/report_keywords/cipher_mode |
|
|
pdf_data/report_keywords/ecc_curve |
|
|
pdf_data/report_keywords/crypto_engine |
|
|
pdf_data/report_keywords/tls_cipher_suite |
|
|
pdf_data/report_keywords/crypto_library |
|
|
pdf_data/report_keywords/vulnerability |
|
|
pdf_data/report_keywords/side_channel_analysis |
|
|
pdf_data/report_keywords/technical_report_id |
|
|
pdf_data/report_keywords/device_model |
|
|
pdf_data/report_keywords/tee_name |
|
|
pdf_data/report_keywords/os_name |
|
|
pdf_data/report_keywords/cplc_data |
|
|
pdf_data/report_keywords/ic_data_group |
|
|
pdf_data/report_keywords/standard_id |
|
- BSI:
- FIPS:
- ISO:
- ISO/IEC 15408: 4
- ISO/IEC 17065: 2
- ISO/IEC 18045: 4
- RFC:
- X509:
|
pdf_data/report_keywords/javacard_version |
|
|
pdf_data/report_keywords/javacard_api_const |
|
|
pdf_data/report_keywords/javacard_packages |
|
|
pdf_data/report_keywords/certification_process |
|
- ConfidentialDocument:
- 1170, 2024-03-21; SVN Liste aller entwicklungsrelevanten Dokumente, Version 809, 2024-03-22, (confidential documents) [11] Guidance documentation for the TOE, Version 2.2.0, 2023-11-24, Bedienungsanleitung: 1
- Report, Version 3, 2024-03-25, EVALUATION TECHNICAL REPORT SUMMARY, TÜV Informationstechnik GmbH, (confidential document) [8] Common Criteria Protection Profile Mobile Card Terminal for the German Healthcare System: 1
- being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
|
pdf_data/report_metadata |
- /CreationDate: D:20181210152644-05'00'
- /ModDate: D:20181210152644-05'00'
- pdf_file_size_bytes: 822095
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 18
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, Mobile Card Terminal for the German Healthcare System (MobCT), BSI-CC-PP-0052-2015"
- /Subject: Common Criteria, Certification, Zertifizierung, Mobile Card Terminal for the German Healthcare System (MobCT), BSI-CC-PP-0052-2015
- /Title: Certification Report BSI-DSZ-CC-0623-V3-2024
- pdf_file_size_bytes: 336199
- pdf_hyperlinks: http://www.commoncriteriaportal.org/cc/, https://www.sogis.eu/, https://www.bsi.bund.de/AIS, http://www.commoncriteriaportal.org/, https://www.commoncriteriaportal.org/, https://www.bsi.bund.de/zertifizierung, https://www.bsi.bund.de/zertifizierungsreporte, https://www.bsi.bund.de/
- pdf_is_encrypted: False
- pdf_number_of_pages: 23
|
pdf_data/st_filename |
st_vid10907-st.pdf |
0623V3b_pdf.pdf |
pdf_data/st_frontpage |
|
|
pdf_data/st_keywords/cc_cert_id |
|
|
pdf_data/st_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0032: 1
- BSI-CC-PP-0052: 2
|
pdf_data/st_keywords/cc_security_level |
|
- EAL:
- EAL 3: 4
- EAL 3 augmented: 3
- EAL3+: 2
|
pdf_data/st_keywords/cc_sar |
- ADV:
- AGD:
- AGD_OPE.1: 2
- AGD_PRE.1: 2
- ALC:
- ALC_CMC.1: 2
- ALC_CMS.1: 2
- ATE:
- AVA:
|
- ADV:
- ADV_ARC.1: 1
- ADV_FSP.4: 5
- ADV_IMP.1: 5
- ADV_TDS.3: 5
- AGD:
- AGD_OPE.1: 1
- AGD_PRE.1: 1
- ALC:
- ALC_CMC.3: 1
- ALC_CMS.3: 1
- ALC_DEL.1: 1
- ALC_DVS.1: 1
- ALC_LCD.1: 1
- ALC_TAT.1: 5
- ATE:
- ATE_COV.2: 1
- ATE_DPT.1: 1
- ATE_FUN.1: 1
- ATE_IND.2: 1
- AVA:
|
pdf_data/st_keywords/cc_sfr |
- FAU:
- FAU_GEN.1: 5
- FAU_GEN.1.1: 1
- FAU_GEN.1.2: 1
- FAU_GEN.2: 4
- FAU_GEN.2.1: 1
- FAU_STG_EXT.1: 4
- FAU_STG_EXT.1.1: 1
- FAU_STG_EXT.1.2: 1
- FAU_STG_EXT.1.3: 1
- FCS:
- FCS_CKM.1: 7
- FCS_CKM.1.1: 2
- FCS_CKM.2: 4
- FCS_CKM.2.1: 1
- FCS_CKM.4: 4
- FCS_CKM.4.1: 1
- FCS_COP: 22
- FCS_COP.1: 4
- FCS_DTLS: 1
- FCS_RBG_EXT.1: 7
- FCS_RBG_EXT.1.1: 1
- FCS_RBG_EXT.1.2: 1
- FCS_SSHC_EXT.1: 1
- FCS_SSHC_EXT.1.5: 1
- FCS_SSHC_EXT.1.8: 2
- FCS_SSHC_EXT.1.9: 1
- FCS_SSHS_EXT.1: 5
- FCS_SSHS_EXT.1.1: 1
- FCS_SSHS_EXT.1.2: 3
- FCS_SSHS_EXT.1.3: 1
- FCS_SSHS_EXT.1.4: 1
- FCS_SSHS_EXT.1.5: 1
- FCS_SSHS_EXT.1.6: 1
- FCS_SSHS_EXT.1.7: 1
- FCS_SSHS_EXT.1.8: 3
- FCS_TLSC_EXT: 1
- FCS_TLSC_EXT.1.1: 1
- FCS_TLSC_EXT.1.2: 2
- FCS_TLSC_EXT.2: 1
- FCS_TLSC_EXT.2.1: 1
- FCS_TLSC_EXT.2.2: 1
- FCS_TLSS_EXT.1: 1
- FCS_TLSS_EXT.2: 1
- FCS_TLSS_EXT.2.4: 1
- FCS_TLSS_EXT.2.5: 1
- FIA:
- FIA_AFL.1: 4
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_PMG_EXT.1: 4
- FIA_PMG_EXT.1.1: 1
- FIA_UAU.7: 3
- FIA_UAU.7.1: 1
- FIA_UAU_EXT.2: 4
- FIA_UAU_EXT.2.1: 1
- FIA_UIA_EXT.1: 5
- FIA_UIA_EXT.1.1: 1
- FIA_UIA_EXT.1.2: 1
- FMT:
- FMT_MOF: 4
- FMT_MOF.1: 1
- FMT_MTD: 9
- FMT_MTD.1: 1
- FMT_SMF.1: 4
- FMT_SMF.1.1: 1
- FMT_SMR.2: 4
- FMT_SMR.2.1: 1
- FMT_SMR.2.2: 1
- FMT_SMR.2.3: 1
- FPT:
- FPT_APW_EXT: 1
- FPT_APW_EXT.1: 3
- FPT_APW_EXT.1.1: 1
- FPT_APW_EXT.1.2: 1
- FPT_ITT.1: 1
- FPT_SKP_EXT.1: 4
- FPT_SKP_EXT.1.1: 1
- FPT_STM_EXT.1: 5
- FPT_STM_EXT.1.1: 1
- FPT_STM_EXT.1.2: 1
- FPT_TST_EXT: 1
- FPT_TST_EXT.1: 3
- FPT_TST_EXT.1.1: 1
- FPT_TUD_EXT.1: 4
- FPT_TUD_EXT.1.1: 1
- FPT_TUD_EXT.1.2: 1
- FPT_TUD_EXT.1.3: 1
- FTA:
- FTA_SSL.3: 5
- FTA_SSL.4: 4
- FTA_SSL.4.1: 1
- FTA_SSL_EXT.1: 4
- FTA_SSL_EXT.1.1: 1
- FTA_TAB.1: 7
- FTP:
- FTP_ITC.1: 8
- FTP_ITC.1.2: 1
- FTP_TRP: 3
- FTP_TRP.1: 5
|
- FCS:
- FCS_CKM.1: 23
- FCS_CKM.1.1: 1
- FCS_CKM.2: 2
- FCS_CKM.4: 22
- FCS_CKM.4.1: 1
- FCS_COP: 31
- FCS_COP.1: 5
- FDP:
- FDP_ACC.1: 30
- FDP_ACC.1.1: 1
- FDP_ACF.1: 25
- FDP_ACF.1.1: 1
- FDP_ACF.1.2: 5
- FDP_ACF.1.3: 1
- FDP_ACF.1.4: 5
- FDP_IFC: 41
- FDP_IFC.1: 11
- FDP_IFF: 45
- FDP_IFF.1: 25
- FDP_ITC.1: 21
- FDP_ITC.1.1: 1
- FDP_ITC.1.2: 1
- FDP_ITC.1.3: 1
- FDP_ITC.2: 9
- FDP_RIP: 15
- FDP_RIP.1: 2
- FDP_SDI.1: 1
- FDP_SDI.2: 9
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FDP_SVR: 2
- FDP_SVR.1: 12
- FDP_SVR.1.1: 5
- FDP_SVR.1.2: 3
- FDP_SVR.1.3: 3
- FIA:
- FIA_AFL.1: 10
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_SOS.1: 8
- FIA_SOS.1.1: 1
- FIA_UAU.1: 13
- FIA_UAU.1.1: 1
- FIA_UAU.1.2: 1
- FIA_UAU.5: 11
- FIA_UAU.5.1: 1
- FIA_UAU.5.2: 1
- FIA_UAU.7: 10
- FIA_UAU.7.1: 2
- FIA_UID.1: 17
- FIA_UID.1.1: 1
- FIA_UID.1.2: 1
- FMT:
- FMT_MSA.1: 12
- FMT_MSA.1.1: 1
- FMT_MSA.3: 26
- FMT_MSA.3.1: 1
- FMT_MSA.3.2: 1
- FMT_MTD.1: 11
- FMT_MTD.1.1: 1
- FMT_MTD.3: 8
- FMT_MTD.3.1: 1
- FMT_SMF.1: 14
- FMT_SMF.1.1: 1
- FMT_SMR.1: 20
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPT:
- FPT_PHP.1: 7
- FPT_PHP.1.1: 1
- FPT_PHP.1.2: 1
- FPT_STM.1: 12
- FPT_STM.1.1: 1
- FPT_TST.1: 7
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FTA:
- FTA_SSL.3: 10
- FTA_SSL.3.1: 2
- FTA_SSL.4: 10
- FTA_SSL.4.1: 1
- FTP:
|
pdf_data/st_keywords/cc_claims |
- A:
- A.ADMIN_CREDENTIALS_SECURE: 1
- A.LIMITED_FUNCTIONALITY: 1
- A.NO_THRU_TRAFFIC_PROTECTION: 1
- A.PHYSICAL_PROTECTION: 2
- A.REGULAR_UPDATES: 1
- A.RESIDUAL_INFORMATION: 1
- A.TRUSTED_ADMINISTRATOR: 1
- OE:
- OE.ADMIN_CREDENTIALS_SECURE: 1
- OE.NO_GENERAL_PURPOSE: 1
- OE.NO_THRU_TRAFFIC_PROTECTION: 1
- OE.PHYSICAL: 1
- OE.RESIDUAL_INFORMATION: 1
- OE.TRUSTED_ADMIN: 1
- OE.UPDATES: 1
- T:
- T.PASSWORD_CRACKING: 1
- T.SECURITY_FUNCTIONALITY_COMPROMISE: 1
- T.SECURITY_FUNCTIONALITY_FAILURE: 1
- T.UNAUTHORIZED_ADMINISTRATOR_ACCESS: 1
- T.UNDETECTED_ACTIVITY: 1
- T.UNTRUSTED_COMMUNICATION_CHANNELS: 1
- T.UPDATE_COMPROMISE: 1
- T.WEAK_AUTHENTICATION_ENDPOINTS: 1
- T.WEAK_CRYPTOGRAPHY: 1
|
- A:
- A.ADMIN: 3
- A.CARDS: 4
- A.DEVELOPER: 1
- A.DMS: 3
- A.ENVIRONMEN: 1
- A.ENVIRONMENT: 2
- A.MEDIC: 3
- A.PHYSICAL: 3
- O:
- O.AUTH_STATE: 9
- O.DMS_CONNECT: 1
- O.DMS_CONNECTION: 5
- O.LOG_CARDS: 3
- O.LOG_DATA: 6
- O.MANAGEMENT: 9
- O.PIN: 7
- O.PROTECTION: 8
- O.RESIDUAL: 6
- O.SEALING: 3
- O.SELFTESTS: 6
- O.TIME: 6
- O.TRANSFER: 3
- OE:
- OE.ADMIN: 9
- OE.CARDS: 8
- OE.DEVELOPER: 1
- OE.DMS: 4
- OE.ENVIRONMENT: 6
- OE.MEDIC: 10
- OE.PHYSICAL: 6
- OSP:
- OSP.DMS_CONN: 1
- OSP.DMS_CONNE: 1
- OSP.DMS_CONNECTION: 1
- OSP.EMERGENC: 1
- OSP.EMERGENCY_: 1
- OSP.EMERGENCY_DATA: 1
- OSP.LOG_CARD: 1
- OSP.LOG_CARDS: 1
- OSP.LOG_DATA: 3
- OSP.SEALING: 3
- OSP.SELFTESTS: 3
- OSP.TIME: 3
- OSP.TRANSFER: 3
- T:
- T.ACCESS: 3
- T.ADMIN_PIN: 3
- T.AUTH_STATE: 3
- T.DATA: 3
- T.FIRMWARE: 3
- T.MAN_HW: 3
|
pdf_data/st_keywords/vendor |
- Cisco:
- Cisco: 52
- Cisco Systems: 1
- Cisco Systems, Inc: 3
|
|
pdf_data/st_keywords/eval_facility |
|
|
pdf_data/st_keywords/symmetric_crypto |
- AES_competition:
- AES:
- AES: 18
- AES128: 2
- AES256: 2
- constructions:
- MAC:
- HMAC: 8
- HMAC-SHA-256: 4
- HMAC-SHA-512: 3
|
|
pdf_data/st_keywords/asymmetric_crypto |
- ECC:
- FF:
- DH:
- DH: 14
- Diffie-Hellman: 10
|
|
pdf_data/st_keywords/pq_crypto |
|
|
pdf_data/st_keywords/hash_function |
- PBKDF:
- SHA:
- SHA1:
- SHA2:
- SHA-256: 5
- SHA-512: 10
- SHA512: 1
|
|
pdf_data/st_keywords/crypto_scheme |
- KEX:
- Key Exchange: 2
- Key exchange: 1
- MAC:
|
|
pdf_data/st_keywords/crypto_protocol |
|
|
pdf_data/st_keywords/randomness |
|
|
pdf_data/st_keywords/cipher_mode |
|
|
pdf_data/st_keywords/ecc_curve |
|
|
pdf_data/st_keywords/crypto_engine |
|
|
pdf_data/st_keywords/tls_cipher_suite |
|
|
pdf_data/st_keywords/crypto_library |
|
|
pdf_data/st_keywords/vulnerability |
|
|
pdf_data/st_keywords/side_channel_analysis |
|
|
pdf_data/st_keywords/technical_report_id |
|
|
pdf_data/st_keywords/device_model |
|
|
pdf_data/st_keywords/tee_name |
|
|
pdf_data/st_keywords/os_name |
|
|
pdf_data/st_keywords/cplc_data |
|
|
pdf_data/st_keywords/ic_data_group |
|
|
pdf_data/st_keywords/standard_id |
- FIPS:
- FIPS 140-2: 3
- FIPS 186-4: 1
- FIPS PUB 140-2: 1
- FIPS PUB 180-3: 2
- FIPS PUB 186-3: 1
- FIPS PUB 186-4: 7
- FIPS PUB 198-1: 1
- ISO:
- ISO/IEC 18031:2011: 3
- ISO/IEC 9796-2: 1
- NIST:
- NIST SP 800-56B: 2
- SP 800-56A: 1
- SP 800-56B: 2
- SP 800-90: 2
- SP 800-90A: 1
- PKCS:
- RFC:
- RFC 2986: 1
- RFC 3526: 4
- RFC 3602: 2
- RFC 4109: 1
- RFC 4253: 1
- RFC 4301: 1
- RFC 4303: 1
- RFC 4945: 1
- RFC 5280: 4
- RFC 5759: 1
- RFC 6187: 1
- X509:
|
|
pdf_data/st_keywords/javacard_version |
|
|
pdf_data/st_keywords/javacard_api_const |
|
|
pdf_data/st_keywords/javacard_packages |
|
|
pdf_data/st_keywords/certification_process |
|
- OutOfScope:
- done by an authorised card that is out of scope of this ST: 1
- out of scope: 1
- the TOE • Signature generation for emergency data1 on the eHC (done by an authorised card that is out of scope of this ST) 1.4.6 Physical Protection of the TOE The TOE cannot counter physical attacks concerning: 1
|
pdf_data/st_metadata |
|
- /Author: Bundesamt für Sicherheit in der Informationstechnik
- /Keywords: Protection Profile, Mobile Card Terminal, Electronic Health Card
- /Subject: Mobile Card Terminal, electronic Health Card
- /Title: Common Criteria Protection Profile BSI-PP-0052
- pdf_file_size_bytes: 461165
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 75
|
state/cert/convert_garbage |
True |
False |
state/cert/convert_ok |
True |
True |
state/cert/download_ok |
True |
True |
state/cert/extract_ok |
True |
True |
state/cert/pdf_hash |
Different |
Different |
state/cert/txt_hash |
Different |
Different |
state/report/convert_garbage |
False |
False |
state/report/convert_ok |
True |
True |
state/report/download_ok |
True |
True |
state/report/extract_ok |
True |
True |
state/report/pdf_hash |
Different |
Different |
state/report/txt_hash |
Different |
Different |
state/st/convert_garbage |
False |
False |
state/st/convert_ok |
True |
True |
state/st/download_ok |
True |
True |
state/st/extract_ok |
True |
True |
state/st/pdf_hash |
Different |
Different |
state/st/txt_hash |
Different |
Different |