name |
EMC® VNX OE for Block v5.31 with Unisphere™ v7.0 running on VNX Series Hardware Model VNX5100™ and EMC® VNX OE for File v7.0 and VNX OE for Block v5.31 with Unisphere™ v7.0 running on VNX Series Hardware Models VNX5300™, VNX5500™, VNX5700™, and VNX7500™ |
SMARTY IQ-GPRS / LTE, Version 1.4 |
category |
Other Devices and Systems |
Other Devices and Systems |
scheme |
CA |
DE |
status |
archived |
active |
not_valid_after |
15.05.2017 |
19.12.2032 |
not_valid_before |
30.05.2011 |
20.12.2024 |
cert_link |
|
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6c_pdf.pdf |
report_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/emc-vnx-v531-cert-eng.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6a_pdf.pdf |
st_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/emc-vnx-v531-sec-eng.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/0822V6b_pdf.pdf |
manufacturer |
EMC Corporation |
Sagemcom Dr. Neuhaus GmbH |
manufacturer_web |
https://www.emc.com/ |
https://sagemcom.com |
security_level |
EAL3+, ALC_FLR.2 |
EAL4+, ALC_FLR.2, AVA_VAN.5 |
dgst |
5c135ac1bf057d70 |
4b7dcf610d994944 |
heuristics/cert_id |
383-4-172 |
BSI-DSZ-CC-0822-V6-2024 |
heuristics/cert_lab |
CANADA |
BSI |
heuristics/cpe_matches |
{} |
{} |
heuristics/verified_cpe_matches |
{} |
{} |
heuristics/related_cves |
{} |
{} |
heuristics/direct_transitive_cves |
{} |
{} |
heuristics/indirect_transitive_cves |
{} |
{} |
heuristics/extracted_sars |
ASE_INT.1, AVA_VAN.2, ALC_CMC.3, ALC_CMS.3, ASE_ECD.1, ATE_COV.2, ASE_TSS.1, ASE_SPD.1, ADV_TDS.2, ALC_DEL.1, ALC_LCD.1, AGD_OPE.1, AGD_PRE.1, ATE_FUN.1, ADV_ARC.1, ASE_OBJ.2, ATE_DPT.1, ALC_FLR.2, ASE_REQ.2, ALC_DVS.1, ATE_IND.2, ADV_FSP.3, ASE_CCL.1 |
ATE_COV.2, ASE_TSS.1, ASE_INT.1, ATE_FUN.1, AVA_VAN.5, ALC_DEL.1, ALC_LCD.1, ADV_ARC.1, AGD_OPE.1, ASE_REQ.2, ASE_CCL.1, ALC_CMC.4, ALC_FLR.2, ADV_IMP.1 |
heuristics/extracted_versions |
7.0, 5.31 |
1.4 |
heuristics/prev_certificates |
{} |
{} |
heuristics/next_certificates |
{} |
{} |
heuristics/report_references/directly_referenced_by |
{} |
{} |
heuristics/report_references/directly_referencing |
{} |
BSI-DSZ-CC-0822-V5-2023 |
heuristics/report_references/indirectly_referenced_by |
{} |
{} |
heuristics/report_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0822-V2-2020, BSI-DSZ-CC-0822-V4-2023, BSI-DSZ-CC-0822-V3-2021, BSI-DSZ-CC-0822-V5-2023 |
heuristics/scheme_data |
|
- category: Intelligent measuring systems
- cert_id: BSI-DSZ-CC-0822-V6-2024
- certification_date: 20.12.2024
- enhanced:
- applicant: Sagemcom Dr. Neuhaus GmbH Papenreye 65 22453 Hamburg
- assurance_level: EAL4+,AVA_VAN.5,ALC_FLR.2
- cert_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6c_pdf.pdf?__blob=publicationFile&v=2
- certification_date: 20.12.2024
- entries: [frozendict({'id': 'BSI-DSZ-CC-0822-V6-2024', 'description': 'The focus of this recertification was on the introduction of a new LTE-Modul for WAN-communication, the GWA-change process implementation following FNN requirements and the introduction of proxy-profiles and communication scenario HKS3 with SOCKSv5.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V5-2023', 'description': 'components.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V4-2023', 'description': 'The focus of this recertification was on the update of the operating system and some libraries, the implementation of changed and added tariff use cases (TAF 2, TAF 9, TAF 10, TAF 14), the support of IPv6 and the support of firmware download.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-RA-02', 'description': 'The CC-certificate BSI-DSZ-CC-0822-V3-2021 remains valid for 2 further years.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-RA-01', 'description': 'Successful Re-Assessment with update of the vulnerability analysis.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-MA-02', 'description': 'Security Target'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021-MA-01', 'description': 'version number remains the same as the alternative components have the same behaviour as the original one.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V3-2021', 'description': 'The previoulsly certified TOE was changed and re-certified to implement minor security-relevant optimizations.'}), frozendict({'id': 'BSI-DSZ-CC-0822-V2-2020', 'description': 'Certificate'}), frozendict({'id': 'BSI-DSZ-CC-0822-2019-MA-01 (20.11.2019)', 'description': 'Certificate invalid'}), frozendict({'id': 'BSI-DSZ-CC-0822-2019 (25.09.2019)', 'description': 'Certificate invalid'})]
- evaluation_facility: TÜV Informationstechnik GmbH
- expiration_date: 19.12.2032
- product: SMARTY IQ-LTE, Version 1.4
- protection_profile: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI-CC-PP-0073-2014
- report_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6a_pdf.pdf?__blob=publicationFile&v=2
- target_link: https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte08/0822V6b_pdf.html?nn=456626
- product: SMARTY IQ-LTE, Version 1.4
- subcategory: (Smart Meter Gateway)
- url: https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/SmartMeter_Gateway/0822_0822V2_0822V3_0822V4_0822V5_0822V6.html
- vendor: Sagemcom Dr. Neuhaus GmbH
|
heuristics/st_references/directly_referenced_by |
{} |
{} |
heuristics/st_references/directly_referencing |
{} |
BSI-DSZ-CC-0957-V2-2016 |
heuristics/st_references/indirectly_referenced_by |
{} |
{} |
heuristics/st_references/indirectly_referencing |
{} |
BSI-DSZ-CC-0957-V2-2016, BSI-DSZ-CC-0978-2016 |
heuristics/protection_profiles |
{} |
6346b04de6859db3 |
maintenance_updates |
|
|
protection_profiles |
|
|
protection_profile_links |
{} |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0073b_pdf.pdf |
pdf_data/cert_filename |
|
0822V6c_pdf.pdf |
pdf_data/cert_frontpage |
|
|
pdf_data/cert_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0822-V6-2024: 1
|
pdf_data/cert_keywords/cc_protection_profile_id |
|
|
pdf_data/cert_keywords/cc_security_level |
|
- EAL:
- EAL 2: 1
- EAL 4: 2
- EAL 4 augmented: 1
- EAL 5: 1
|
pdf_data/cert_keywords/cc_sar |
|
|
pdf_data/cert_keywords/cc_sfr |
|
|
pdf_data/cert_keywords/cc_claims |
|
|
pdf_data/cert_keywords/vendor |
|
|
pdf_data/cert_keywords/eval_facility |
|
|
pdf_data/cert_keywords/symmetric_crypto |
|
|
pdf_data/cert_keywords/asymmetric_crypto |
|
|
pdf_data/cert_keywords/pq_crypto |
|
|
pdf_data/cert_keywords/hash_function |
|
|
pdf_data/cert_keywords/crypto_scheme |
|
|
pdf_data/cert_keywords/crypto_protocol |
|
|
pdf_data/cert_keywords/randomness |
|
|
pdf_data/cert_keywords/cipher_mode |
|
|
pdf_data/cert_keywords/ecc_curve |
|
|
pdf_data/cert_keywords/crypto_engine |
|
|
pdf_data/cert_keywords/tls_cipher_suite |
|
|
pdf_data/cert_keywords/crypto_library |
|
|
pdf_data/cert_keywords/vulnerability |
|
|
pdf_data/cert_keywords/side_channel_analysis |
|
|
pdf_data/cert_keywords/technical_report_id |
|
|
pdf_data/cert_keywords/device_model |
|
|
pdf_data/cert_keywords/tee_name |
|
|
pdf_data/cert_keywords/os_name |
|
|
pdf_data/cert_keywords/cplc_data |
|
|
pdf_data/cert_keywords/ic_data_group |
|
|
pdf_data/cert_keywords/standard_id |
|
- ISO:
- ISO/IEC 15408: 2
- ISO/IEC 18045: 2
|
pdf_data/cert_keywords/javacard_version |
|
|
pdf_data/cert_keywords/javacard_api_const |
|
|
pdf_data/cert_keywords/javacard_packages |
|
|
pdf_data/cert_keywords/certification_process |
|
|
pdf_data/cert_metadata |
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid"
- /Subject: Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid
- /Title: Certificate BSI-DSZ-CC-0822-V6-2024
- pdf_file_size_bytes: 335622
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
pdf_data/report_filename |
emc-vnx-v531-cert-eng.pdf |
0822V6a_pdf.pdf |
pdf_data/report_frontpage |
- DE:
- CA:
- cert_id: 383-4-172-CR
- cert_lab: CANADA
|
- DE:
- cc_security_level: Common Criteria Part 3 conformant EAL 4 augmented by ALC_FLR.2 and AVA_VAN.5 valid until: 19 December 2032
- cc_version: PP conformant Common Criteria Part 2 extended
- cert_id: BSI-DSZ-CC-0822-V6-2024
- cert_item: SMARTY IQ-LTE, Version 1.4
- cert_lab: BSI
- developer: Sagemcom Dr. Neuhaus GmbH
- match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
- ref_protection_profiles: Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014, BSI- CC-PP-0073-2014
- CA:
|
pdf_data/report_keywords/cc_cert_id |
- CA:
- 383-4-172: 1
- 383-4-172-CR: 1
|
- DE:
- BSI-DSZ-CC-0822-V5-2023: 3
- BSI-DSZ-CC-0822-V6-2024: 14
- BSI-DSZ-CC-0957-: 1
|
pdf_data/report_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073-2014: 3
- BSI-CC-PP-0077-V2-2015: 2
|
pdf_data/report_keywords/cc_security_level |
|
- EAL:
- EAL 1: 1
- EAL 2: 3
- EAL 4: 8
- EAL 4 augmented: 3
- EAL 5: 3
- EAL 5+: 1
- EAL 6: 1
|
pdf_data/report_keywords/cc_sar |
|
|
pdf_data/report_keywords/cc_sfr |
|
|
pdf_data/report_keywords/cc_claims |
|
|
pdf_data/report_keywords/vendor |
|
|
pdf_data/report_keywords/eval_facility |
|
- TUV:
- TÜV Informationstechnik: 3
|
pdf_data/report_keywords/symmetric_crypto |
|
- AES_competition:
- constructions:
|
pdf_data/report_keywords/asymmetric_crypto |
|
|
pdf_data/report_keywords/pq_crypto |
|
|
pdf_data/report_keywords/hash_function |
|
|
pdf_data/report_keywords/crypto_scheme |
|
|
pdf_data/report_keywords/crypto_protocol |
|
|
pdf_data/report_keywords/randomness |
|
|
pdf_data/report_keywords/cipher_mode |
|
|
pdf_data/report_keywords/ecc_curve |
|
|
pdf_data/report_keywords/crypto_engine |
|
|
pdf_data/report_keywords/tls_cipher_suite |
|
|
pdf_data/report_keywords/crypto_library |
|
|
pdf_data/report_keywords/vulnerability |
|
|
pdf_data/report_keywords/side_channel_analysis |
|
|
pdf_data/report_keywords/technical_report_id |
|
- BSI:
- BSI 7148: 1
- BSI TR-03109: 1
- BSI TR-03116: 1
|
pdf_data/report_keywords/device_model |
|
|
pdf_data/report_keywords/tee_name |
|
|
pdf_data/report_keywords/os_name |
|
|
pdf_data/report_keywords/cplc_data |
|
|
pdf_data/report_keywords/ic_data_group |
|
|
pdf_data/report_keywords/standard_id |
|
- BSI:
- AIS 32: 1
- AIS 34: 2
- AIS 38: 1
- AIS 46: 2
- AIS 48: 1
- FIPS:
- FIPS 186-4: 1
- FIPS PUB 180-4: 1
- FIPS PUB 186: 1
- FIPS180-4: 3
- ISO:
- ISO/IEC 15408: 4
- ISO/IEC 17065: 2
- ISO/IEC 18045: 4
- RFC:
- RFC 2104: 1
- RFC 5246: 1
- RFC 5639: 1
- RFC 5652: 1
- RFC 8289: 1
- RFC 8422: 1
- RFC2104: 2
- RFC4493: 6
- RFC5084: 2
- RFC5246: 6
- RFC5288: 2
- RFC5289: 3
- RFC5639: 6
- RFC5652: 4
- RFC6033: 2
- RFC6090: 4
- RFC6161: 2
- RFC8422: 2
|
pdf_data/report_keywords/javacard_version |
|
|
pdf_data/report_keywords/javacard_api_const |
|
|
pdf_data/report_keywords/javacard_packages |
|
|
pdf_data/report_keywords/certification_process |
|
- ConfidentialDocument:
- 23 / 27 Certification Report BSI-DSZ-CC-0822-V6-2024 [9] Configuration list for the TOE (confidential documents): filelist_OS, 2024-11-12 filelist_sln8209, 2024-11-12 8209SE011_SMGw_CPU_USB, Version 3.3: 1
- Technical Report BSI-DSZ-CC-0822-V6, Version 1, 2024-11-15, TÜV Informationstechnik GmbH, (confidential document) [8] Protection Profile for the Gateway of a Smart Metering System, Version 1.3, 31 March 2014: 1
- being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
|
pdf_data/report_metadata |
- /AM_ACPP_Date: [dd month yyyy]
- /AM_ACPP_Doc#: [AM_AMCPP_Doc#]
- /AM_ACPP_Title: Assurance Continuity Program Plan (ACPP)
- /AM_ACPP_Version: [AM_AMCPP_Version]
- /AM_IAR_Date: [dd month yyyy]
- /AM_IAR_Doc#: [AM_IAR_Doc#]
- /AM_IAR_Title: Assurance Maintenace Impact Analysis Report
- /AM_IAR_Version: [AM_IAR_Version]
- /AM_ST Date: [dd month yyyy]
- /AM_ST Title: [AM_ST Title]
- /AM_ST Version: [AM_ST Version]
- /AM_TOE: [AM_TOE]
- /AM_TOE Short: [AM_TOE Short]
- /AM_TOE Version: [AM_TOE Version]
- /Author: sjackson
- /CC Version: 3.1R3
- /CC date: July 2009
- /CEM Version: 3.1R3
- /CEM date: July 2009
- /CR_Date: TBD
- /CR_Version: 1.0
- /Client City: Hopkinton
- /Client Country: USA
- /Client Full Name: EMC Corporation
- /Client Postal Code: 01748
- /Client Short Name: EMC
- /Client State: MA
- /Client Street: 171 South Street
- /Comments: PCR Template Version 0.1-EWA-C (for CC 3.1)
- /Company: Hewlett-Packard
- /CreationDate: D:20110708105045-04'00'
- /Creator: Acrobat PDFMaker 10.0 for Word
- /Developer Long Name: EMC Corporation
- /Developer Short Name: EMC
- /EAL Level: 3+
- /EAL Level Base: 3
- /EAL Level Text: 3 augmented
- /EAL Long: EAL 3 Augmented
- /EAL Short: EAL 3+
- /ER Document Date: 15 September 2010
- /ER Version: Version 1.0
- /ETPlan_Doc#: 1683-000-D003
- /ETPlan_Title: Evaluation Test Plan
- /ETPlan_Version: 1.0
- /ETPlan_date: 7 April 2011
- /ETProcRes_Date: 7 April 2011
- /ETProcRes_Doc#: 1683-000-D004
- /ETProcRes_Title: Evaluation Test Procedures and Test results
- /ETProcRes_Version: 1.0
- /ETProc_Date: 7 April 2011
- /ETProc_Doc#: 1683-000-D004
- /ETProc_Title: Evaluation Test Procedures and Test results
- /ETProc_Version: 1.0
- /ETReport_Date: 30 May 2011
- /ETReport_Doc#: 1683-000-D002
- /ETReport_Title: Evaluation Technical Report
- /ETReport_TitleShort: ETR
- /ETReport_Version: 1.2
- /EWP_Date: 12 November 2010
- /EWP_Doc#: 1683-000-D001
- /EWP_Title: Evaluation Work Plan
- /EWP_Version: 1.0
- /Eval number: 383-4-172
- /Eval_End_Date: 1 July 2011
- /Eval_Start_Date: 2 August 2010
- /Keywords:
- /LeadEvaluator: Greg Lague
- /LeadEvaluatorInitials: GL
- /ModDate: D:20110708105130-04'00'
- /Producer: Acrobat Distiller 10.0.0 (Windows)
- /ProjectManager: M. Gauvreau
- /ProjectManagerInitials: MG
- /ProjectNumber: 1683
- /ST_Date: 27 May 2011
- /ST_Title: EMC® VNX OE for Block v5.31 with Unisphere™ running on VNX Series Hardware Model VNX5100™ and EMC® VNX OE (VNX for File v7.0 and VNX for Block v5.31) with Unisphere™ running on VNX Series Hardware Models VNX5300™, VNX5500™, VNX5700™, and VNX7500™
- /ST_Version: 0.8
- /SVC_Date: 9 December 2009
- /SVC_Doc#: 1683-000-D007
- /SVC_Title: Site Visit Checklist
- /SVC_Version: 0.1
- /SVR_Date: 7 April 2011
- /SVR_Doc#: 1683-000-D006
- /SVR_Title: Site Visit Report
- /SVR_Version: 1.0
- /SV_City: Hopkinton, MA
- /Security Classification: EWA-Canada & EMC Proprietary
- /SourceModified: D:20110708141631
- /Sponsor: EMC
- /Sponsor City: Hopkinton
- /Sponsor Country: USA
- /Sponsor Postal Code: 01748
- /Sponsor State: MA
- /Sponsor Street: 171 South Street
- /Subject:
- /TOE: EMC® VNX OE for Block v5.31 with Unisphere™ running on VNX Series Hardware Model VNX5100™ and EMC® VNX OE (VNX for File v7.0 and VNX for Block v5.31) with Unisphere™ running on VNX Series Hardware Models VNX5300™, VNX5500™, VNX5700™, and VNX7500™
- /TOE Short: EMC® VNX OE
- /TOE Short with version: EMC® VNX OE
- /TOE Short-NoTM: EMC® VNX OE
- /TOE Version: Block v5.31 and File v7.0
- /TOE with version: EMC® VNX OE for Block v5.31 and File v7.0 with Unisphere™ running on VNX Series Hardware
- /TOE-NoTM: EMC VNX OE for Block v5.31 and File v7.0 with Unisphere running on VNX Series Hardware
- /Title: EAL X+ Evaluation of [Developer Long Name]
- pdf_file_size_bytes: 89946
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 12
|
- /Author: Federal Office for Information Security
- /Keywords: "Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid"
- /Subject: Common Criteria, Certification, Zertifizierung, SMGW, Smartmeter Gateway, Sagemcom, Dr. Neuhaus, Smart Grid
- /Title: Certification Report BSI-DSZ-CC-0822-V6-2024
- pdf_file_size_bytes: 661868
- pdf_hyperlinks: http://www.commoncriteriaportal.org/cc/, https://www.sogis.eu/, https://www.bsi.bund.de/AIS, http://www.commoncriteriaportal.org/, https://www.commoncriteriaportal.org/, https://www.bsi.bund.de/zertifizierung, https://www.bsi.bund.de/zertifizierungsreporte, https://www.bsi.bund.de/
- pdf_is_encrypted: False
- pdf_number_of_pages: 27
|
pdf_data/st_filename |
emc-vnx-v531-sec-eng.pdf |
0822V6b_pdf.pdf |
pdf_data/st_frontpage |
|
|
pdf_data/st_keywords/cc_cert_id |
|
- DE:
- BSI-DSZ-CC-0957-V2-2016: 1
|
pdf_data/st_keywords/cc_protection_profile_id |
|
- BSI:
- BSI-CC-PP-0073: 4
- BSI-CC-PP-0077-2013: 1
|
pdf_data/st_keywords/cc_security_level |
- EAL:
- EAL3: 1
- EAL3 augmented: 1
- EAL3+: 4
|
- EAL:
- EAL 4: 5
- EAL 4 augmented: 2
- EAL4: 1
- EAL4 augmented: 1
|
pdf_data/st_keywords/cc_sar |
- ADV:
- ADV_ARC.1: 1
- ADV_FSP.3: 1
- ADV_TDS.2: 1
- AGD:
- AGD_OPE.1: 1
- AGD_PRE.1: 1
- ALC:
- ALC_CMC.3: 1
- ALC_CMS.3: 1
- ALC_DEL.1: 1
- ALC_DVS.1: 1
- ALC_FLR.2: 4
- ALC_LCD.1: 1
- ASE:
- ASE_CCL.1: 1
- ASE_ECD.1: 1
- ASE_INT.1: 1
- ASE_OBJ.2: 1
- ASE_REQ.2: 1
- ASE_SPD.1: 1
- ASE_TSS.1: 1
- ATE:
- ATE_COV.2: 1
- ATE_DPT.1: 1
- ATE_FUN.1: 1
- ATE_IND.2: 1
- AVA:
|
- ADV:
- ADV_ARC.1: 1
- ADV_IMP.1: 1
- AGD:
- ALC:
- ALC_CMC.4: 1
- ALC_DEL.1: 1
- ALC_FLR.2: 6
- ALC_LCD.1: 1
- ASE:
- ASE_CCL.1: 1
- ASE_INT.1: 1
- ASE_REQ.2: 1
- ASE_TSS.1: 1
- ATE:
- ATE_COV.2: 1
- ATE_FUN.1: 1
- AVA:
|
pdf_data/st_keywords/cc_sfr |
- FAU:
- FAU_GEN: 2
- FAU_GEN.1: 7
- FAU_GEN.1.1: 1
- FAU_GEN.1.2: 1
- FAU_SAR.1: 6
- FAU_SAR.1.1: 1
- FAU_SAR.1.2: 1
- FDP:
- FDP_ACC: 20
- FDP_ACC.1: 2
- FDP_ACF: 17
- FDP_ACF.1: 8
- FDP_SDI.1: 1
- FDP_SDI.2: 7
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FIA:
- FIA_ATD.1: 6
- FIA_ATD.1.1: 1
- FIA_UAU.1: 1
- FIA_UAU.2: 7
- FIA_UAU.2.1: 1
- FIA_UID.1: 8
- FIA_UID.2: 9
- FIA_UID.2.1: 1
- FMT:
- FMT_MSA: 32
- FMT_MSA.1: 2
- FMT_MSA.3: 4
- FMT_MTD: 18
- FMT_MTD.1: 3
- FMT_SMF.1: 16
- FMT_SMF.1.1: 1
- FMT_SMR.1: 20
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPT:
|
- FAU:
- FAU_ARP: 10
- FAU_ARP.1: 1
- FAU_CON.1.2: 1
- FAU_GEN: 39
- FAU_GEN.1: 17
- FAU_GEN.2: 10
- FAU_GEN.2.1: 1
- FAU_SAA: 15
- FAU_SAA.1: 4
- FAU_SAR: 30
- FAU_SAR.1: 6
- FAU_STG: 34
- FAU_STG.1: 8
- FAU_STG.2: 10
- FAU_STG.2.1: 1
- FAU_STG.2.2: 1
- FAU_STG.2.3: 1
- FAU_STG.3: 3
- FAU_STG.4: 3
- FCO:
- FCO_NRO: 3
- FCO_NRO.1: 1
- FCO_NRO.2: 11
- FCO_NRO.2.1: 1
- FCO_NRO.2.2: 1
- FCO_NRO.2.3: 1
- FCS:
- FCS_CKM: 51
- FCS_CKM.1: 16
- FCS_CKM.2: 6
- FCS_CKM.4: 30
- FCS_CKM.4.1: 1
- FCS_COP: 68
- FCS_COP.1: 11
- FDP:
- FDP_ACC: 2
- FDP_ACC.1: 9
- FDP_ACC.2: 12
- FDP_ACC.2.1: 1
- FDP_ACC.2.2: 1
- FDP_ACF: 1
- FDP_ACF.1: 11
- FDP_ACF.1.1: 1
- FDP_ACF.1.2: 1
- FDP_ACF.1.3: 1
- FDP_ACF.1.4: 1
- FDP_IFC: 29
- FDP_IFC.1: 12
- FDP_IFC.2: 4
- FDP_IFF: 26
- FDP_IFF.1: 18
- FDP_ITC.1: 12
- FDP_ITC.2: 12
- FDP_RIP: 2
- FDP_RIP.1: 1
- FDP_RIP.2: 8
- FDP_RIP.2.1: 1
- FDP_SDI: 2
- FDP_SDI.1: 1
- FDP_SDI.2: 9
- FDP_SDI.2.1: 1
- FDP_SDI.2.2: 1
- FIA:
- FIA_AFL: 3
- FIA_AFL.1: 10
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_ATD: 3
- FIA_ATD.1: 13
- FIA_ATD.1.1: 1
- FIA_UAU: 5
- FIA_UAU.1: 2
- FIA_UAU.2: 9
- FIA_UAU.2.1: 1
- FIA_UAU.5: 9
- FIA_UAU.5.1: 1
- FIA_UAU.5.2: 1
- FIA_UAU.6: 10
- FIA_UAU.6.1: 1
- FIA_UID: 3
- FIA_UID.1: 8
- FIA_UID.2: 14
- FIA_UID.2.1: 1
- FIA_USB: 3
- FIA_USB.1: 9
- FIA_USB.1.1: 1
- FIA_USB.1.2: 1
- FIA_USB.1.3: 1
- FMT:
- FMT_MOF: 1
- FMT_MOF.1: 9
- FMT_MOF.1.1: 1
- FMT_MSA: 64
- FMT_MSA.1: 9
- FMT_MSA.3: 12
- FMT_SMF: 2
- FMT_SMF.1: 19
- FMT_SMF.1.1: 1
- FMT_SMR: 3
- FMT_SMR.1: 29
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPR:
- FPR_CON: 6
- FPR_CON.1: 12
- FPR_CON.1.1: 3
- FPR_CON.1.2: 3
- FPR_PSE: 3
- FPR_PSE.1: 9
- FPR_PSE.1.1: 1
- FPR_PSE.1.2: 1
- FPR_PSE.1.3: 1
- FPT:
- FPT_FLS: 3
- FPT_FLS.1: 9
- FPT_FLS.1.1: 2
- FPT_PHP: 3
- FPT_PHP.1: 8
- FPT_PHP.1.1: 1
- FPT_PHP.1.2: 1
- FPT_RPL: 3
- FPT_RPL.1: 10
- FPT_RPL.1.1: 1
- FPT_RPL.1.2: 1
- FPT_STM: 3
- FPT_STM.1: 20
- FPT_STM.1.1: 1
- FPT_TST: 3
- FPT_TST.1: 10
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FTP:
|
pdf_data/st_keywords/cc_claims |
- A:
- A.MANAGE: 2
- A.NOEVIL: 2
- A.PHYSICAL: 2
- A.PROTECT: 2
- A.TIMESTAMP: 2
- O:
- O.ADMIN: 23
- O.AUDIT: 4
- O.AUDIT_REVIEW: 4
- O.BYPASS: 7
- O.PROTECT: 16
- OE:
- OE.PROPER_NAME_ASSIGNME: 2
- OE.PROPER_NAME_ASSIGNMEN: 1
- OE.SECURE_COMMUNICATIO: 6
- OE.SECURE_COMMUNICATION: 1
- OE.SECURE_SERVERS: 7
- OE.TIME: 3
- T:
- T.DATA_CORRUPTION: 2
- T.IMPROPER_CONFIG: 2
- T.IMPROPER_SERVER: 2
- T.MEDIATE_ACCESS: 2
- T.UNAUTH: 2
|
|
pdf_data/st_keywords/vendor |
|
|
pdf_data/st_keywords/eval_facility |
|
|
pdf_data/st_keywords/symmetric_crypto |
|
- AES_competition:
- constructions:
|
pdf_data/st_keywords/asymmetric_crypto |
|
|
pdf_data/st_keywords/pq_crypto |
|
|
pdf_data/st_keywords/hash_function |
|
- JH:
- SHA:
- SHA2:
- SHA-256: 3
- SHA-384: 2
- SHA256: 1
|
pdf_data/st_keywords/crypto_scheme |
|
|
pdf_data/st_keywords/crypto_protocol |
|
|
pdf_data/st_keywords/randomness |
|
|
pdf_data/st_keywords/cipher_mode |
|
|
pdf_data/st_keywords/ecc_curve |
|
- NIST:
- NIST P-256: 2
- NIST P-384: 1
- P-256: 2
- P-384: 1
|
pdf_data/st_keywords/crypto_engine |
|
|
pdf_data/st_keywords/tls_cipher_suite |
|
- TLS:
- TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256: 2
- TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256: 2
- TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384: 2
- TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384: 2
|
pdf_data/st_keywords/crypto_library |
|
|
pdf_data/st_keywords/vulnerability |
|
|
pdf_data/st_keywords/side_channel_analysis |
|
- FI:
- malfunction: 3
- physical tampering: 2
|
pdf_data/st_keywords/technical_report_id |
|
- BSI:
- BSI 7586: 1
- BSI TR-02102-2: 1
- BSI TR-03109: 1
- BSI TR-03109-1: 9
- BSI TR-03109-2: 1
- BSI TR-03109-3: 1
- BSI TR-03109-4: 1
- BSI TR-03111: 1
- BSI TR-03116-3: 1
- BSI TR-03116-4: 1
|
pdf_data/st_keywords/device_model |
|
|
pdf_data/st_keywords/tee_name |
|
|
pdf_data/st_keywords/os_name |
|
|
pdf_data/st_keywords/cplc_data |
|
|
pdf_data/st_keywords/ic_data_group |
|
|
pdf_data/st_keywords/standard_id |
|
- BSI:
- FIPS:
- FIPS 140-2: 1
- FIPS 180-4: 3
- FIPS 197: 6
- RFC:
- RFC 2104: 4
- RFC 4493: 5
- RFC 5084: 3
- RFC 5246: 4
- RFC 5289: 4
- RFC 5652: 1
- RFC 5905: 3
- RFC5246: 2
- RFC5905: 1
|
pdf_data/st_keywords/javacard_version |
|
|
pdf_data/st_keywords/javacard_api_const |
|
- curves:
- SECP256R1: 2
- SECP384R1: 1
|
pdf_data/st_keywords/javacard_packages |
|
|
pdf_data/st_keywords/certification_process |
|
|
pdf_data/st_metadata |
- /Author: Greg Milliken
- /CreationDate: D:20110527131502Z
- /Creator: Microsoft® Office Word 2007
- /ModDate: D:20110621111006-04'00'
- /Producer: Microsoft® Office Word 2007
- /Subject: EMC® VNX OE for Block v5.31 with Unisphere™ v7.0 running on VNX Series Hardware Model VNX5100™ and EMC® VNX OE for File v7.0 and VNX OE for Block v5.31 with Unisphere™ v7.0 running on VNX Series Hardware Models VNX5300™, VNX5500™, VNX5700™, and VNX7500™
- /Title: Security Target
- pdf_file_size_bytes: 887892
- pdf_hyperlinks: mailto:[email protected], http://www.corsec.com/, http://www.emc.com/
- pdf_is_encrypted: False
- pdf_number_of_pages: 49
|
- /Author: Federal Office for Information Security
- /Keywords: Smart Meter System, Gateway, Common Criteria, Smart Meter Gateway PP
- /Subject: Schutzprofil für die Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen
- /Title: Sagemcom Dr. Neuhaus SMARTY IQ-LTE Security Target
- pdf_file_size_bytes: 2020364
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 112
|
state/cert/convert_garbage |
False |
False |
state/cert/convert_ok |
False |
True |
state/cert/download_ok |
False |
True |
state/cert/extract_ok |
False |
True |
state/cert/pdf_hash |
Different |
Different |
state/cert/txt_hash |
Different |
Different |
state/report/convert_garbage |
False |
False |
state/report/convert_ok |
True |
True |
state/report/download_ok |
True |
True |
state/report/extract_ok |
True |
True |
state/report/pdf_hash |
Different |
Different |
state/report/txt_hash |
Different |
Different |
state/st/convert_garbage |
False |
False |
state/st/convert_ok |
True |
True |
state/st/download_ok |
True |
True |
state/st/extract_ok |
True |
True |
state/st/pdf_hash |
Different |
Different |
state/st/txt_hash |
Different |
Different |