Smart Meter Gateway Security Module Application on MultiApp V4 Revision A
CSV information ?
Status | active |
---|---|
Valid from | 18.09.2018 |
Valid until | 18.09.2028 |
Scheme | 🇩🇪 DE |
Manufacturer | Gemalto |
Category | ICs, Smart Cards and Smart Card-Related Devices and Systems |
Security level | AVA_VAN.5, EAL4 |
Heuristics summary ?
Certificate ?
Extracted keywords
Vendor
GemaltoSecurity level
EAL 4, EAL 5, EAL 2, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ALC_FLR, AVA_VAN.5Protection profiles
BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-1003-2018Standards
ISO/IEC 15408, ISO/IEC 18045File metadata
Title | Certification Report BSI-DSZ-CC-1003-2018 |
---|---|
Subject | Smart Meter Gateway Security Module Application on MultiApp V4 Revision A |
Keywords | "Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto" |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20180920083617+02'00' |
Modification date | D:20180928134141+02'00' |
Pages | 1 |
Creator | Writer |
Producer | LibreOffice 5.2 |
Certification report ?
Extracted keywords
Symmetric Algorithms
AES, CMACAsymmetric Algorithms
ECDSA, ECC, DH, Diffie-HellmanHash functions
SHA-2, JHSchemes
MAC, Key Agreement, KAProtocols
TLS, PACERandomness
RNGBlock cipher modes
CBCVendor
Infineon, Infineon Technologies AG, GemaltoSecurity level
EAL 4, EAL 5, EAL 2, EAL 1, EAL 2+, EAL 5+, EAL 6, EAL 4 augmentedSecurity Assurance Requirements (SAR)
ADV_ARC, ADV_COMP.1, AGD_PRE, AGD_OPE, ALC_FLR, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, AVA_VAN.5, AVA_VANSecurity Functional Requirements (SFR)
FCS_COP, FCS_CKM, FCS_RNG.1, FIA_UID.1, FIA_UAU.4, FIA_UAU.5, FTP_ITC.1Protection profiles
BSI-CC-PP-0077-V2-2015, BSI-CC-PP- 0077-V2-2015Certificates
BSI-DSZ-CC-1003-2018, BSI-DSZ-CC-0891-V2-2016, ANSSI-CC-2017/54Evaluation facilities
Serma Safety & Security, TÃœV InformationstechnikSide-channel analysis
malfunction, JILCertification process
being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification, Target of Security Module for Smart Meter Gateway, D1359877, Version 2.1, 3 August 2018, Gemalto (confidential document) [7] Security Target Lite BSI-DSZ-CC-1003-2018, Security Target Lite of Security Module for Smart, Application on MultiApp V4 Revision A, Version 3, 10 August 2018, TÃœV Informationstechnik GmbH (confidential document) [10] Configuration List BSI-DSZ-CC-1003-2018, Configuration List for Smart Meter Gateway Security, v1.1,Version 1.2, 3 August 2018, and File LIS_SMGWSMV11_CAR_LBL03_1.65.1.7.1.5.1.20, Gemalto (confidential document) [11] Preparation Guidance for Smart Meter Gateway Security Module V1.1, D1393787, Release 1.2, 3Standards
FIPS 180-4, FIPS 186-3, FIPS 197, FIPS PUB 180-4, FIPS PUB 186-3, FIPS PUB 197, AIS 34, AIS 36, AIS 26, AIS 25, AIS 20, AIS 31, AIS 35, AIS 1, AIS 14, AIS 19, AIS 32, AIS 37, AIS 38, AIS 46, RFC 5639, RFC 4493, ISO/IEC 15408, ISO/IEC 18045, ISO/IEC 17065, ISO/IEC 10116, ISO/IEC 7816-4Technical reports
BSI TR-3109-2, BSI TR-03109-2, BSI TR-03109-3, BSI TR-03116-3, BSI TR-03110-2, BSI TR-03110-3, BSI 7148File metadata
Title | Certification Report BSI-DSZ-CC-1003-2018 |
---|---|
Subject | Smart Meter Gateway Security Module Application on MultiApp V4 Revision A |
Keywords | "Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto" |
Author | Bundesamt für Sicherheit in der Informationstechnik |
Creation date | D:20180920083559+02'00' |
Modification date | D:20180928133832+02'00' |
Pages | 32 |
Creator | Writer |
Producer | LibreOffice 5.2 |
Frontpage
Certificate ID | BSI-DSZ-CC-1003-2018 |
---|---|
Certified item | Smart Meter Gateway Security Module Application on MultiApp V4 Revision A |
Certification lab | BSI |
Developer | Gemalto SA |
References
Outgoing- ANSSI-CC-2017/54 - archived - Plateforme JavaCard MultiApp V4.0 - PACE en configuration ouverte basée sur l'Operating System JLEP3 masquée sur le composant SLE78CLFX4000PH (M7892 G12)
- BSI-DSZ-CC-0891-V2-2016 - archived - Infineon Security Controller, M7892 Design Steps D11 and G12, with optional RSA2048/4096 v2.03.008, EC v2.03.008, SHA-2 v1.01 and Toolbox v2.03.008 libraries, symmetric crypto library v2.02.010 and with specific IC dedicated software (firmware)
Security target ?
Extracted keywords
Symmetric Algorithms
AES, AES-, DES, CMACAsymmetric Algorithms
ECDH, ECDSA, ECC, Diffie-Hellman, DHSchemes
MAC, Key Exchange, Key AgreementProtocols
TLS, PACE, IKERandomness
RNG, RNDElliptic Curves
P-256, P-384, NIST P-256, NIST P-384, secp256r1, secp384r1, brainpoolP256r1, brainpoolP384r1, brainpoolP512r1Block cipher modes
CBCCPLC
IC Fabricator, IC TypeVendor
Infineon, GemaltoSecurity level
EAL 4, EAL 5, EAL4, EAL 5 augmented, EAL4 augmentedClaims
O.PACE, T.CONFID-JCS-CODE, T.CONFID-JCS-DATA, T.INTEG-JCS-CODE, T.INTEG-JCS-DATA, T.INTEG-APPLI-DATA, T.SID, T.EXE-CODE, T.NATIVE, T.INSTALL, T.OBJ-DELETION, T.RESOURCES, T.CONFID-APPLI-DATA, T.INTEG-APPLI-CODE, T.PHYSICAL, A.VERIFICATION, A.APPLET, OE.PACE, OSP.SM, OSP.VERIFICATION, OSP.RNDSecurity Assurance Requirements (SAR)
ADV_ARC.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE_PLTF, AGD_OPE, AGD_PRE_PLTF, AGD_PRE, AGD_OPE_SMGW, AGD_PRE_SMGW, AGD_OPE.1, AGD_PRE.1, ALC_DVS, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5, AVA_VAN, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1Security Functional Requirements (SFR)
FCS_RNG, FCS_RNG.1, FCS_RNG.1.1, FCS_RNG.1.2, FCS_CKM, FCS_CKM.4, FCS_COP, FCS_CKM.1, FCS_COP.1, FCS_CKM.2, FCS_CKM.4.1, FDP_ACF, FDP_ACC.2, FDP_ACF.1, FDP_SDI.2, FDP_RIP.1, FDP_ETC.1, FDP_ITC.1, FDP_UCT.1, FDP_UIT.1, FDP_ITC.2, FDP_ACC, FDP_ACC.1, FDP_ACC.2.1, FDP_ACC.2.2, FDP_ACF.1.1, FDP_ACF.1.2, FDP_ACF.1.3, FDP_ACF.1.4, FDP_SDI, FDP_SDI.1, FDP_SDI.2.1, FDP_SDI.2.2, FDP_RIP, FDP_RIP.1.1, FDP_ETC, FDP_IFC.1, FDP_ETC.1.1, FDP_ETC.1.2, FDP_ITC, FDP_ITC.1.1, FDP_ITC.1.2, FDP_ITC.1.3, FDP_UCT, FDP_UCT.1.1, FDP_UIT, FDP_UIT.1.1, FDP_UIT.1.2, FIA_ATD.1, FIA_SOS.1, FIA_UAU, FIA_UAU.4, FIA_UAU.5, FIA_UID.1, FIA_USB.1, FIA_ATD, FIA_ATD.1.1, FIA_SOS, FIA_SOS.1.1, FIA_UAU.1, FIA_UAU.4.1, FIA_UAU.5.1, FIA_UAU.5.2, FIA_UID, FIA_UID.1.1, FIA_UID.1.2, FIA_USB, FIA_USB.1.2, FIA_USB.1.3, FMT_LIM, FMT_LIM.1, FMT_LIM.2, FMT_LIM.1.1, FMT_LIM.2.1, FMT_SMF.1, FMT_SMR.1, FMT_MSA.3, FMT_SMF, FMT_SMF.1.1, FMT_SMR, FMT_SMR.1.1, FMT_SMR.1.2, FPT_EMS, FPT_EMS.1, FPT_EMS.1.1, FPT_EMS.1.2, FPT_FLS.1, FPT_PHP.3, FPT_TST.1, FPT_FLS, FPT_FLS.1.1, FPT_PHP, FPT_PHP.3.1, FPT_TST, FPT_TST.1.1, FPT_TST.1.2, FPT_TST.1.3, FTP_ITC.1, FTP_TRP.1, FTP_ITC, FTP_ITC.1.1, FTP_ITC.1.2, FTP_ITC.1.3Protection profiles
BSI-CC-PP- 0084-2014, BSI-CC-PP-0073-2014, BSI-CC-PP-0077-V2-2015Certificates
BSI-DSZ-CC-1003-2017, BSI-DSZ-CC-1003-2018, BSI-DSZ-CC-0891-V2-2016, ANSSI-CC-2017/54, CC-1, CC-2, CC-3Side-channel analysis
physical probing, side channels, side channel, DPA, SPA, timing attacks, physical tampering, Malfunction, malfunction, DFA, fault injectionCertification process
out of scope, entities. As these external entities do not directly interact with the TOE, these entities are out of scope for this ST. During its pre-operational phases the TOE interacts with the Integrator and theStandards
FIPS180-4, FIPS186, FIPS PUB 186-3, FIPS197, FIPS46-3, FIPS PUB 46-3, FIPS 197, PKCS#3, AIS31, AIS 31, AIS36, AIS 36, AIS 20, RFC 2409, RFC 4493, RFC 4993, RFC5639, RFC 5639, ISO/IEC 10116, X.509, CCMB-2012-09-001, CCMB-2012-09-002, CCMB-2012-09-003Technical reports
BSI TR-03109-3, BSI TR-03110-1, BSI TR-03110-2, BSI TR-03110-3, BSI TR-03116-3File metadata
Title | Security Target of Security Module for Smart Meter Gateway (PUBLIC version) BSI-DSZ-CC-1003-2017 TOE NAME: Smart Meter Gateway SM applet on MultiApp V4 |
---|---|
Subject | SM for Smart Meter (Public Version) |
Keywords | Security Target, CC, Smart Meter |
Author | F.GUERIN |
Creation date | D:20180803120200+02'00' |
Modification date | D:20180803120200+02'00' |
Pages | 79 |
Creator | Microsoft® Word 2013 |
Producer | Microsoft® Word 2013 |
References
Outgoing- ANSSI-CC-2017/54 - archived - Plateforme JavaCard MultiApp V4.0 - PACE en configuration ouverte basée sur l'Operating System JLEP3 masquée sur le composant SLE78CLFX4000PH (M7892 G12)
- BSI-DSZ-CC-0891-V2-2016 - archived - Infineon Security Controller, M7892 Design Steps D11 and G12, with optional RSA2048/4096 v2.03.008, EC v2.03.008, SHA-2 v1.01 and Toolbox v2.03.008 libraries, symmetric crypto library v2.02.010 and with specific IC dedicated software (firmware)
- BSI-DSZ-CC-1000-2023 - active - Secure Smart Grid Hub (SGH-S), V1.00
Heuristics ?
Extracted SARs
ADV_ARC.1, ADV_COMP.1, ADV_FSP.4, ADV_IMP.1, ADV_TDS.3, AGD_OPE.1, AGD_PRE.1, ALC_CMC.4, ALC_CMS.4, ALC_DEL.1, ALC_DVS.1, ALC_LCD.1, ALC_TAT.1, ASE_CCL.1, ASE_ECD.1, ASE_INT.1, ASE_OBJ.2, ASE_REQ.2, ASE_SPD.1, ASE_TSS.1, ATE_COV.2, ATE_DPT.1, ATE_FUN.1, ATE_IND.2, AVA_VAN.5Scheme data ?
Cert Id | BSI-DSZ-CC-1003-2018 | |
---|---|---|
Product | Smart Meter Gateway Security Module Application on MultiApp V4 Revision A | |
Vendor | Gemalto SA | |
Certification Date | 18.09.2018 | |
Category | Intelligent measuring systems | |
Url | https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/Smartmeter_Sicherheitsmodule/1003.html | |
Enhanced | ||
Product | Smart Meter Gateway Security Module Application on MultiApp V4 Revision A | |
Applicant | Gemalto SA 6, Rue de la Verrerie 92190 Meudon Frankreich | |
Evaluation Facility | TÃœV Informationstechnik GmbH | |
Assurance Level | EAL4+,AVA_VAN.5 | |
Protection Profile | Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015 | |
Certification Date | 18.09.2018 | |
Expiration Date | 17.09.2028 | |
Report Link | https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1003a_pdf.pdf?__blob=publicationFile&v=1 | |
Target Link | https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1003b_pdf.pdf?__blob=publicationFile&v=1 | |
Cert Link | https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1003c_pdf.pdf?__blob=publicationFile&v=1 | |
Description | The Target of Evaluation (TOE) is the product Smart Meter Gateway Security Module Application on MultiApp V4 Revision A from Gemalto SA. The TOE is a Smart Meter Security Module on base of the Technical Guideline BSI TR-03109-2, Version 1.1 intended to be used by a Smart Meter Gateway in a Smart Metering System. The TOE serves as cryptographic service provider for the Smart Meter Gateway and supports the Smart Meter Gateway for its specific cryptographic needs. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further data relevant for the Gateway. | |
Subcategory | Security module for an Smart Metering Gateway |
References ?
Updates ?
-
21.11.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The following values were inserted:
{'prev_certificates': [], 'next_certificates': []}
.
- The following values were inserted:
-
09.11.2024 The certificate data changed.
Certificate changed
The computed heuristics were updated.
- The scheme_data property was updated, with the
{'certification_date': '2018-09-18', 'enhanced': {'__update__': {'applicant': 'Gemalto SA 6, Rue de la Verrerie 92190 Meudon Frankreich', 'certification_date': '2018-09-18', 'expiration_date': '2028-09-17'}}}
data.
- The scheme_data property was updated, with the
-
22.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The st property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'cf320913a582afd299839285636da64608d093a6d96e2ef6d72988533fd0443e', 'txt_hash': 'dd5dec878c2c251457cc5c00ab8293f5f0420adfb4a6ddd6253d198c01fa33ee'}
data. - The cert property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': 'bd54eb702e1947dac6a3ec5a67e202a9796ee8c7656efb7a4d797acd924a4256', 'txt_hash': 'f27660122bfd0806d2bc6349b88ff20f1355214d2ae025ed1c9802388e34b0a7'}
data.
The PDF extraction data was updated.
- The st_metadata property was set to
{'pdf_file_size_bytes': 2286486, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 79, '/Title': 'Security Target of Security Module for Smart Meter Gateway (PUBLIC version) BSI-DSZ-CC-1003-2017 TOE NAME: Smart Meter Gateway SM applet on MultiApp V4', '/Author': 'F.GUERIN', '/Subject': 'SM for Smart Meter (Public Version)', '/Keywords': 'Security Target, CC, Smart Meter', '/Creator': 'Microsoft® Word 2013', '/CreationDate': "D:20180803120200+02'00'", '/ModDate': "D:20180803120200+02'00'", '/Producer': 'Microsoft® Word 2013', 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['http://csrc.nist.gov/publications/fips/fips180-4/fips-180-4.pdf', 'http://www.sogisportal.eu/documents/cc/common/JIL-Collection-of-Developer-Evidence-v1-5.pdf']}}
. - The cert_metadata property was set to
{'pdf_file_size_bytes': 355322, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 1, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20180920083617+02'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto"', '/ModDate': "D:20180928134141+02'00'", '/Producer': 'LibreOffice 5.2', '/Subject': 'Smart Meter Gateway Security Module Application on MultiApp V4 Revision A', '/Title': 'Certification Report BSI-DSZ-CC-1003-2018', 'pdf_hyperlinks': {'_type': 'Set', 'elements': []}}
. - The st_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-1003-2017': 1, 'BSI-DSZ-CC-1003-2018': 1, 'BSI-DSZ-CC-0891-V2-2016': 1}, 'FR': {'ANSSI-CC-2017/54': 1}, 'NL': {'CC-1': 5, 'CC-2': 2, 'CC-3': 3}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP- 0084-2014': 1, 'BSI-CC-PP-0073-2014': 1, 'BSI-CC-PP-0077-V2-2015': 3}}, 'cc_security_level': {'EAL': {'EAL 4': 2, 'EAL 5': 1, 'EAL4': 2, 'EAL 5 augmented': 1, 'EAL4 augmented': 1}}, 'cc_sar': {'ADV': {'ADV_ARC.1': 1, 'ADV_FSP.4': 1, 'ADV_IMP.1': 1, 'ADV_TDS.3': 1}, 'AGD': {'AGD_OPE_PLTF': 6, 'AGD_OPE': 1, 'AGD_PRE_PLTF': 4, 'AGD_PRE': 1, 'AGD_OPE_SMGW': 4, 'AGD_PRE_SMGW': 2, 'AGD_OPE.1': 1, 'AGD_PRE.1': 1}, 'ALC': {'ALC_DVS': 2, 'ALC_CMC.4': 1, 'ALC_CMS.4': 1, 'ALC_DEL.1': 1, 'ALC_DVS.1': 1, 'ALC_LCD.1': 1, 'ALC_TAT.1': 1}, 'ATE': {'ATE_COV.2': 1, 'ATE_DPT.1': 1, 'ATE_FUN.1': 1, 'ATE_IND.2': 1}, 'AVA': {'AVA_VAN.5': 12, 'AVA_VAN': 2}, 'ASE': {'ASE_CCL.1': 1, 'ASE_ECD.1': 1, 'ASE_INT.1': 1, 'ASE_OBJ.2': 1, 'ASE_REQ.2': 1, 'ASE_SPD.1': 1, 'ASE_TSS.1': 1}}, 'cc_sfr': {'FCS': {'FCS_RNG': 7, 'FCS_RNG.1': 10, 'FCS_RNG.1.1': 2, 'FCS_RNG.1.2': 2, 'FCS_CKM': 29, 'FCS_CKM.4': 23, 'FCS_COP': 26, 'FCS_CKM.1': 13, 'FCS_COP.1': 7, 'FCS_CKM.2': 4, 'FCS_CKM.4.1': 1}, 'FDP': {'FDP_ACF': 2, 'FDP_ACC.2': 7, 'FDP_ACF.1': 4, 'FDP_SDI.2': 4, 'FDP_RIP.1': 5, 'FDP_ETC.1': 3, 'FDP_ITC.1': 13, 'FDP_UCT.1': 3, 'FDP_UIT.1': 3, 'FDP_ITC.2': 7, 'FDP_ACC': 1, 'FDP_ACC.1': 6, 'FDP_ACC.2.1': 1, 'FDP_ACC.2.2': 1, 'FDP_ACF.1.1': 1, 'FDP_ACF.1.2': 1, 'FDP_ACF.1.3': 1, 'FDP_ACF.1.4': 1, 'FDP_SDI': 1, 'FDP_SDI.1': 1, 'FDP_SDI.2.1': 2, 'FDP_SDI.2.2': 1, 'FDP_RIP': 1, 'FDP_RIP.1.1': 1, 'FDP_ETC': 1, 'FDP_IFC.1': 4, 'FDP_ETC.1.1': 1, 'FDP_ETC.1.2': 1, 'FDP_ITC': 1, 'FDP_ITC.1.1': 1, 'FDP_ITC.1.2': 1, 'FDP_ITC.1.3': 1, 'FDP_UCT': 1, 'FDP_UCT.1.1': 1, 'FDP_UIT': 1, 'FDP_UIT.1.1': 1, 'FDP_UIT.1.2': 1}, 'FIA': {'FIA_ATD.1': 5, 'FIA_SOS.1': 3, 'FIA_UAU': 9, 'FIA_UAU.4': 3, 'FIA_UAU.5': 3, 'FIA_UID.1': 9, 'FIA_USB.1': 3, 'FIA_ATD': 1, 'FIA_ATD.1.1': 1, 'FIA_SOS': 1, 'FIA_SOS.1.1': 1, 'FIA_UAU.1': 3, 'FIA_UAU.4.1': 1, 'FIA_UAU.5.1': 1, 'FIA_UAU.5.2': 1, 'FIA_UID': 1, 'FIA_UID.1.1': 1, 'FIA_UID.1.2': 1, 'FIA_USB': 1, 'FIA_USB.1.2': 1, 'FIA_USB.1.3': 1}, 'FMT': {'FMT_LIM': 6, 'FMT_LIM.1': 17, 'FMT_LIM.2': 16, 'FMT_LIM.1.1': 2, 'FMT_LIM.2.1': 2, 'FMT_SMF.1': 4, 'FMT_SMR.1': 3, 'FMT_MSA.3': 2, 'FMT_SMF': 1, 'FMT_SMF.1.1': 1, 'FMT_SMR': 1, 'FMT_SMR.1.1': 1, 'FMT_SMR.1.2': 1}, 'FPT': {'FPT_EMS': 6, 'FPT_EMS.1': 7, 'FPT_EMS.1.1': 3, 'FPT_EMS.1.2': 3, 'FPT_FLS.1': 4, 'FPT_PHP.3': 3, 'FPT_TST.1': 4, 'FPT_FLS': 1, 'FPT_FLS.1.1': 1, 'FPT_PHP': 1, 'FPT_PHP.3.1': 1, 'FPT_TST': 1, 'FPT_TST.1.1': 1, 'FPT_TST.1.2': 1, 'FPT_TST.1.3': 1}, 'FTP': {'FTP_ITC.1': 7, 'FTP_TRP.1': 2, 'FTP_ITC': 1, 'FTP_ITC.1.1': 1, 'FTP_ITC.1.2': 1, 'FTP_ITC.1.3': 1}}, 'cc_claims': {'O': {'O.PACE': 1}, 'T': {'T.CONFID-JCS-CODE': 1, 'T.CONFID-JCS-DATA': 2, 'T.INTEG-JCS-CODE': 3, 'T.INTEG-JCS-DATA': 2, 'T.INTEG-APPLI-DATA': 2, 'T.SID': 4, 'T.EXE-CODE': 6, 'T.NATIVE': 3, 'T.INSTALL': 2, 'T.OBJ-DELETION': 4, 'T.RESOURCES': 3, 'T.CONFID-APPLI-DATA': 1, 'T.INTEG-APPLI-CODE': 2, 'T.PHYSICAL': 4}, 'A': {'A.VERIFICATION': 3, 'A.APPLET': 1}, 'OE': {'OE.PACE': 1}, 'OSP': {'OSP.SM': 1, 'OSP.VERIFICATION': 2, 'OSP.RND': 3}}, 'vendor': {'Infineon': {'Infineon': 6}, 'Gemalto': {'Gemalto': 496}}, 'eval_facility': {}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 10, 'AES-': 1}}, 'DES': {'DES': {'DES': 1}}, 'constructions': {'MAC': {'CMAC': 3}}}, 'asymmetric_crypto': {'ECC': {'ECDH': {'ECDH': 1}, 'ECDSA': {'ECDSA': 29}, 'ECC': {'ECC': 9}}, 'FF': {'DH': {'Diffie-Hellman': 3, 'DH': 16}}}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {'MAC': {'MAC': 3}, 'KEX': {'Key Exchange': 1}, 'KA': {'Key Agreement': 9}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 19}}, 'PACE': {'PACE': 72}, 'IKE': {'IKE': 1}}, 'randomness': {'RNG': {'RNG': 10, 'RND': 5}}, 'cipher_mode': {'CBC': {'CBC': 5}}, 'ecc_curve': {'NIST': {'P-256': 1, 'P-384': 1, 'NIST P-256': 1, 'NIST P-384': 1, 'secp256r1': 1, 'secp384r1': 1}, 'Brainpool': {'brainpoolP256r1': 1, 'brainpoolP384r1': 1, 'brainpoolP512r1': 1}}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'SCA': {'physical probing': 4, 'side channels': 1, 'side channel': 1, 'DPA': 7, 'SPA': 2, 'timing attacks': 2}, 'FI': {'physical tampering': 4, 'Malfunction': 14, 'malfunction': 4, 'DFA': 1, 'fault injection': 1}}, 'technical_report_id': {'BSI': {'BSI TR-03109-3': 1, 'BSI TR-03110-1': 1, 'BSI TR-03110-2': 1, 'BSI TR-03110-3': 1, 'BSI TR-03116-3': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {'ICFab': {'IC Fabricator': 1}, 'ICType': {'IC Type': 1}}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS180-4': 1, 'FIPS186': 3, 'FIPS PUB 186-3': 1, 'FIPS197': 2, 'FIPS46-3': 1, 'FIPS PUB 46-3': 1, 'FIPS 197': 1}, 'PKCS': {'PKCS#3': 1}, 'BSI': {'AIS31': 1, 'AIS 31': 2, 'AIS36': 1, 'AIS 36': 1, 'AIS 20': 1}, 'RFC': {'RFC 2409': 2, 'RFC 4493': 2, 'RFC 4993': 1, 'RFC5639': 4, 'RFC 5639': 1}, 'ISO': {'ISO/IEC 10116': 2}, 'X509': {'X.509': 2}, 'CC': {'CCMB-2012-09-001': 1, 'CCMB-2012-09-002': 1, 'CCMB-2012-09-003': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'OutOfScope': {'out of scope': 1, 'entities. As these external entities do not directly interact with the TOE, these entities are out of scope for this ST. During its pre-operational phases the TOE interacts with the Integrator and the': 1}}}
. - The cert_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-1003-2018': 1}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0077-V2-2015': 1}}, 'cc_security_level': {'EAL': {'EAL 4': 1, 'EAL 5': 1, 'EAL 2': 1, 'EAL 4 augmented': 1}}, 'cc_sar': {'ALC': {'ALC_FLR': 1}, 'AVA': {'AVA_VAN.5': 1}}, 'cc_sfr': {}, 'cc_claims': {}, 'vendor': {'Gemalto': {'Gemalto': 1}}, 'eval_facility': {}, 'symmetric_crypto': {}, 'asymmetric_crypto': {}, 'pq_crypto': {}, 'hash_function': {}, 'crypto_scheme': {}, 'crypto_protocol': {}, 'randomness': {}, 'cipher_mode': {}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {}, 'technical_report_id': {}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'ISO': {'ISO/IEC 15408': 2, 'ISO/IEC 18045': 2}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {}}
. - The st_filename property was set to
1003b_pdf.pdf
. - The cert_filename property was set to
1003c_pdf.pdf
.
The computed heuristics were updated.
- The st_references property was updated, with the
{'directly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-1000-2023']}, 'indirectly_referenced_by': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-1000-2023']}, 'directly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2017/54', 'BSI-DSZ-CC-0891-V2-2016']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2017/54', 'BSI-DSZ-CC-0891-V2-2016']}}
data. - The report_references property was updated, with the
{'directly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2017/54', 'BSI-DSZ-CC-0891-V2-2016']}, 'indirectly_referencing': {'_type': 'Set', 'elements': ['ANSSI-CC-2017/54', 'BSI-DSZ-CC-0782-2012', 'BSI-DSZ-CC-0891-2015', 'BSI-DSZ-CC-0891-V2-2016', 'ANSSI-CC-2017/07']}}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_PRE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_IND', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}]}
values added.
- The st property was updated, with the
-
19.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': True, 'convert_ok': True, 'extract_ok': True, 'pdf_hash': '816b42d78af6250abeae0a03ea39a6e129c268fe4a44e7ae17f3eaa4fce68ce4', 'txt_hash': '93e9bc9c461f8eb070e2594cf01d53155b11d3a57af631fcc69e820580e024fb'}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
{'pdf_file_size_bytes': 899116, 'pdf_is_encrypted': False, 'pdf_number_of_pages': 32, '/Author': 'Bundesamt für Sicherheit in der Informationstechnik', '/CreationDate': "D:20180920083559+02'00'", '/Creator': 'Writer', '/Keywords': '"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto"', '/ModDate': "D:20180928133832+02'00'", '/Producer': 'LibreOffice 5.2', '/Subject': 'Smart Meter Gateway Security Module Application on MultiApp V4 Revision A', '/Title': 'Certification Report BSI-DSZ-CC-1003-2018', 'pdf_hyperlinks': {'_type': 'Set', 'elements': ['https://www.bsi.bund.de/', 'http://www.sogisportal.eu/', 'https://www.bsi.bund.de/zertifizierung', 'http://www.commoncriteriaportal.org/cc/', 'https://www.bsi.bund.de/zertifizierungsreporte', 'http://www.commoncriteriaportal.org/', 'https://www.bsi.bund.de/AIS']}}
. - The report_frontpage property was set to
{'DE': {'match_rules': ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)'], 'cert_id': 'BSI-DSZ-CC-1003-2018', 'cert_item': 'Smart Meter Gateway Security Module Application on MultiApp V4 Revision A', 'developer': 'Gemalto SA', 'cert_lab': 'BSI', 'ref_protection_profiles': 'Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil für das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems für Stoff- und Energiemengen, Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015', 'cc_version': 'PP conformant Common Criteria Part 2 extended', 'cc_security_level': 'Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5'}}
. - The report_keywords property was set to
{'cc_cert_id': {'DE': {'BSI-DSZ-CC-1003-2018': 21, 'BSI-DSZ-CC-0891-V2-2016': 3}, 'FR': {'ANSSI-CC-2017/54': 3}}, 'cc_protection_profile_id': {'BSI': {'BSI-CC-PP-0077-V2-2015': 2, 'BSI-CC-PP- 0077-V2-2015': 1}}, 'cc_security_level': {'EAL': {'EAL 4': 5, 'EAL 5': 4, 'EAL 2': 2, 'EAL 1': 1, 'EAL 2+': 1, 'EAL 5+': 1, 'EAL 6': 1, 'EAL 4 augmented': 3}}, 'cc_sar': {'ADV': {'ADV_ARC': 1, 'ADV_COMP.1': 1}, 'AGD': {'AGD_PRE': 2, 'AGD_OPE': 2}, 'ALC': {'ALC_FLR': 3, 'ALC_CMC.4': 1, 'ALC_CMS.4': 1, 'ALC_DEL.1': 1, 'ALC_DVS.1': 1, 'ALC_LCD.1': 1, 'ALC_TAT.1': 1}, 'AVA': {'AVA_VAN.5': 4, 'AVA_VAN': 1}}, 'cc_sfr': {'FCS': {'FCS_COP': 6, 'FCS_CKM': 5, 'FCS_RNG.1': 1}, 'FIA': {'FIA_UID.1': 1, 'FIA_UAU.4': 1, 'FIA_UAU.5': 1}, 'FTP': {'FTP_ITC.1': 1}}, 'cc_claims': {}, 'vendor': {'Infineon': {'Infineon': 11, 'Infineon Technologies AG': 2}, 'Gemalto': {'Gemalto': 27}}, 'eval_facility': {'Serma': {'Serma Safety & Security': 1}, 'TUV': {'TÃœV Informationstechnik': 3}}, 'symmetric_crypto': {'AES_competition': {'AES': {'AES': 7}}, 'constructions': {'MAC': {'CMAC': 5}}}, 'asymmetric_crypto': {'ECC': {'ECDSA': {'ECDSA': 7}, 'ECC': {'ECC': 3}}, 'FF': {'DH': {'DH': 2, 'Diffie-Hellman': 1}}}, 'pq_crypto': {}, 'hash_function': {'SHA': {'SHA2': {'SHA-2': 1}}, 'JH': {'JH': 1}}, 'crypto_scheme': {'MAC': {'MAC': 3}, 'KA': {'Key Agreement': 7, 'KA': 1}}, 'crypto_protocol': {'TLS': {'TLS': {'TLS': 4}}, 'PACE': {'PACE': 7}}, 'randomness': {'RNG': {'RNG': 2}}, 'cipher_mode': {'CBC': {'CBC': 4}}, 'ecc_curve': {}, 'crypto_engine': {}, 'tls_cipher_suite': {}, 'crypto_library': {}, 'vulnerability': {}, 'side_channel_analysis': {'FI': {'malfunction': 1}, 'other': {'JIL': 5}}, 'technical_report_id': {'BSI': {'BSI TR-3109-2': 1, 'BSI TR-03109-2': 9, 'BSI TR-03109-3': 2, 'BSI TR-03116-3': 2, 'BSI TR-03110-2': 1, 'BSI TR-03110-3': 1, 'BSI 7148': 1}}, 'device_model': {}, 'tee_name': {}, 'os_name': {}, 'cplc_data': {}, 'ic_data_group': {}, 'standard_id': {'FIPS': {'FIPS 180-4': 2, 'FIPS 186-3': 6, 'FIPS 197': 2, 'FIPS PUB 180-4': 1, 'FIPS PUB 186-3': 1, 'FIPS PUB 197': 1}, 'BSI': {'AIS 34': 2, 'AIS 36': 4, 'AIS 26': 3, 'AIS 25': 1, 'AIS 20': 4, 'AIS 31': 2, 'AIS 35': 2, 'AIS 1': 1, 'AIS 14': 1, 'AIS 19': 1, 'AIS 32': 1, 'AIS 37': 1, 'AIS 38': 1, 'AIS 46': 1}, 'RFC': {'RFC 5639': 7, 'RFC 4493': 2}, 'ISO': {'ISO/IEC 15408': 4, 'ISO/IEC 18045': 4, 'ISO/IEC 17065': 2, 'ISO/IEC 10116': 2, 'ISO/IEC 7816-4': 1}}, 'javacard_version': {}, 'javacard_api_const': {}, 'javacard_packages': {}, 'certification_process': {'ConfidentialDocument': {'being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification': 1, 'Target of Security Module for Smart Meter Gateway, D1359877, Version 2.1, 3 August 2018, Gemalto (confidential document) [7] Security Target Lite BSI-DSZ-CC-1003-2018, Security Target Lite of Security Module for Smart': 1, 'Application on MultiApp V4 Revision A, Version 3, 10 August 2018, TÃœV Informationstechnik GmbH (confidential document) [10] Configuration List BSI-DSZ-CC-1003-2018, Configuration List for Smart Meter Gateway Security': 1, 'v1.1,Version 1.2, 3 August 2018, and File LIS_SMGWSMV11_CAR_LBL03_1.65.1.7.1.5.1.20, Gemalto (confidential document) [11] Preparation Guidance for Smart Meter Gateway Security Module V1.1, D1393787, Release 1.2, 3': 1}}}
. - The report_filename property was set to
1003a_pdf.pdf
.
The computed heuristics were updated.
- The cert_lab property was set to
['BSI']
. - The cert_id property was set to
BSI-DSZ-CC-1003-2018
. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DVS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]}
values added.
- The report property was updated, with the
-
17.08.2024 The certificate data changed.
Certificate changed
The report_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003a_pdf.pdf
.
The st_link was updated.
- The new value is
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003b_pdf.pdf
.
The state of the certificate object was updated.
- The report property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data. - The cert property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data.
The PDF extraction data was updated.
- The report_metadata property was set to
None
. - The cert_metadata property was set to
None
. - The report_frontpage property was set to
None
. - The report_keywords property was set to
None
. - The cert_keywords property was set to
None
. - The report_filename property was set to
None
. - The cert_filename property was set to
None
.
The computed heuristics were updated.
- The cert_lab property was set to
None
. - The cert_id property was set to
None
. - The st_references property was updated, with the
{'directly_referenced_by': None, 'indirectly_referenced_by': None}
data. - The report_references property was updated, with the
{'directly_referencing': None, 'indirectly_referencing': None}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMS', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_COMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_TAT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DVS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_DEL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_LCD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ALC_CMC', 'level': 4}]}
values discarded.
- The new value is
-
12.08.2024 The certificate data changed.
Certificate changed
The state of the certificate object was updated.
- The st property was updated, with the
{'download_ok': False, 'convert_ok': False, 'extract_ok': False, 'pdf_hash': None, 'txt_hash': None}
data.
The PDF extraction data was updated.
- The st_metadata property was set to
None
. - The st_keywords property was set to
None
. - The st_filename property was set to
None
.
The computed heuristics were updated.
- The st_references property was updated, with the
{'directly_referencing': None, 'indirectly_referencing': None}
data. - The report_references property was updated, with the
{'indirectly_referencing': {'__discard__': {'_type': 'Set', 'elements': ['BSI-DSZ-CC-0782-2012']}}}
data. - The extracted_sars property was updated, with the
{'_type': 'Set', 'elements': [{'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_PRE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_ARC', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_CCL', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_INT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_OBJ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_ECD', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_FSP', 'level': 4}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_COV', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_FUN', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_REQ', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'AGD_OPE', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_IMP', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ADV_TDS', 'level': 3}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_DPT', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ATE_IND', 'level': 2}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_TSS', 'level': 1}, {'_type': 'sec_certs.sample.sar.SAR', 'family': 'ASE_SPD', 'level': 1}]}
values discarded.
- The st property was updated, with the
-
23.07.2024 The certificate was first processed.
New certificate
A new Common Criteria certificate with the product name Smart Meter Gateway Security Module Application on MultiApp V4 Revision A was processed.
Raw data
{
"_type": "sec_certs.sample.cc.CCCertificate",
"category": "ICs, Smart Cards and Smart Card-Related Devices and Systems",
"cert_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003c_pdf.pdf",
"dgst": "969f3d54aa5e2ed8",
"heuristics": {
"_type": "sec_certs.sample.cc.CCCertificate.Heuristics",
"annotated_references": null,
"cert_id": "BSI-DSZ-CC-1003-2018",
"cert_lab": [
"BSI"
],
"cpe_matches": null,
"direct_transitive_cves": null,
"extracted_sars": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMC",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_INT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_ARC",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_FUN",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AVA_VAN",
"level": 5
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_TAT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_OBJ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_REQ",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_PRE",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DEL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_LCD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_COMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_ECD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_SPD",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_FSP",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_CCL",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_DPT",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_TDS",
"level": 3
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_DVS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_COV",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ASE_TSS",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ATE_IND",
"level": 2
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ALC_CMS",
"level": 4
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "ADV_IMP",
"level": 1
},
{
"_type": "sec_certs.sample.sar.SAR",
"family": "AGD_OPE",
"level": 1
}
]
},
"extracted_versions": {
"_type": "Set",
"elements": [
"-"
]
},
"indirect_transitive_cves": null,
"next_certificates": [],
"prev_certificates": [],
"related_cves": null,
"report_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": null,
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/54"
]
},
"indirectly_referenced_by": null,
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-2015",
"ANSSI-CC-2017/54",
"ANSSI-CC-2017/07",
"BSI-DSZ-CC-0782-2012",
"BSI-DSZ-CC-0891-V2-2016"
]
}
},
"scheme_data": {
"category": "Intelligent measuring systems",
"cert_id": "BSI-DSZ-CC-1003-2018",
"certification_date": "2018-09-18",
"enhanced": {
"applicant": "Gemalto SA 6, Rue de la Verrerie 92190 Meudon Frankreich",
"assurance_level": "EAL4+,AVA_VAN.5",
"cert_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1003c_pdf.pdf?__blob=publicationFile\u0026v=1",
"certification_date": "2018-09-18",
"description": "The Target of Evaluation (TOE) is the product Smart Meter Gateway Security Module Application on MultiApp V4 Revision A from Gemalto SA. The TOE is a Smart Meter Security Module on base of the Technical Guideline BSI TR-03109-2, Version 1.1 intended to be used by a Smart Meter Gateway in a Smart Metering System. The TOE serves as cryptographic service provider for the Smart Meter Gateway and supports the Smart Meter Gateway for its specific cryptographic needs. These cryptographic services cover the following issues: Digital Signature Generation, Digital Signature Verification, Key Agreement for TLS, Key Agreement for Content Data Encryption, Key Pair Generation, Random Number Generation, Component Authentication via the PACE Protocol with Negotiation of Session Keys, Secure Messaging, and Secure Storage of Key Material and further data relevant for the Gateway.",
"evaluation_facility": "T\u00dcV Informationstechnik GmbH",
"expiration_date": "2028-09-17",
"product": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"protection_profile": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil f\u00fcr das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015",
"report_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1003a_pdf.pdf?__blob=publicationFile\u0026v=1",
"target_link": "https://www.bsi.bund.de/SharedDocs/Downloads/DE/BSI/Zertifizierung/Reporte/Reporte1000/1003b_pdf.pdf?__blob=publicationFile\u0026v=1"
},
"product": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"subcategory": "Security module for an Smart Metering Gateway",
"url": "https://www.bsi.bund.de/SharedDocs/Zertifikate_CC/CC/Smartmeter_Sicherheitsmodule/1003.html",
"vendor": "Gemalto SA"
},
"st_references": {
"_type": "sec_certs.sample.certificate.References",
"directly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-1000-2023"
]
},
"directly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/54"
]
},
"indirectly_referenced_by": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-1000-2023"
]
},
"indirectly_referencing": {
"_type": "Set",
"elements": [
"BSI-DSZ-CC-0891-V2-2016",
"ANSSI-CC-2017/54"
]
}
},
"verified_cpe_matches": null
},
"maintenance_updates": {
"_type": "Set",
"elements": []
},
"manufacturer": "Gemalto",
"manufacturer_web": "https://www.gemalto.com/",
"name": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"not_valid_after": "2028-09-18",
"not_valid_before": "2018-09-18",
"pdf_data": {
"_type": "sec_certs.sample.cc.CCCertificate.PdfData",
"cert_filename": "1003c_pdf.pdf",
"cert_frontpage": null,
"cert_keywords": {
"asymmetric_crypto": {},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-1003-2018": 1
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP-0077-V2-2015": 1
}
},
"cc_sar": {
"ALC": {
"ALC_FLR": 1
},
"AVA": {
"AVA_VAN.5": 1
}
},
"cc_security_level": {
"EAL": {
"EAL 2": 1,
"EAL 4": 1,
"EAL 4 augmented": 1,
"EAL 5": 1
}
},
"cc_sfr": {},
"certification_process": {},
"cipher_mode": {},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {},
"crypto_scheme": {},
"device_model": {},
"ecc_curve": {},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {},
"side_channel_analysis": {},
"standard_id": {
"ISO": {
"ISO/IEC 15408": 2,
"ISO/IEC 18045": 2
}
},
"symmetric_crypto": {},
"technical_report_id": {},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"Gemalto": {
"Gemalto": 1
}
},
"vulnerability": {}
},
"cert_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20180920083617+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto\"",
"/ModDate": "D:20180928134141+02\u002700\u0027",
"/Producer": "LibreOffice 5.2",
"/Subject": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"/Title": "Certification Report BSI-DSZ-CC-1003-2018",
"pdf_file_size_bytes": 355322,
"pdf_hyperlinks": {
"_type": "Set",
"elements": []
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 1
},
"report_filename": "1003a_pdf.pdf",
"report_frontpage": {
"DE": {
"cc_security_level": "Common Criteria Part 3 conformant EAL 4 augmented by AVA_VAN.5",
"cc_version": "PP conformant Common Criteria Part 2 extended",
"cert_id": "BSI-DSZ-CC-1003-2018",
"cert_item": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"cert_lab": "BSI",
"developer": "Gemalto SA",
"match_rules": [
"(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)"
],
"ref_protection_profiles": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - Schutzprofil f\u00fcr das Sicherheitsmodul der Kommunikationseinheit eines intelligenten Messsystems f\u00fcr Stoff- und Energiemengen, Version 1.03, 11 December 2014, BSI-CC-PP-0077-V2-2015"
}
},
"report_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 3
},
"ECDSA": {
"ECDSA": 7
}
},
"FF": {
"DH": {
"DH": 2,
"Diffie-Hellman": 1
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0891-V2-2016": 3,
"BSI-DSZ-CC-1003-2018": 21
},
"FR": {
"ANSSI-CC-2017/54": 3
}
},
"cc_claims": {},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP- 0077-V2-2015": 1,
"BSI-CC-PP-0077-V2-2015": 2
}
},
"cc_sar": {
"ADV": {
"ADV_ARC": 1,
"ADV_COMP.1": 1
},
"AGD": {
"AGD_OPE": 2,
"AGD_PRE": 2
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS.1": 1,
"ALC_FLR": 3,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"AVA": {
"AVA_VAN": 1,
"AVA_VAN.5": 4
}
},
"cc_security_level": {
"EAL": {
"EAL 1": 1,
"EAL 2": 2,
"EAL 2+": 1,
"EAL 4": 5,
"EAL 4 augmented": 3,
"EAL 5": 4,
"EAL 5+": 1,
"EAL 6": 1
}
},
"cc_sfr": {
"FCS": {
"FCS_CKM": 5,
"FCS_COP": 6,
"FCS_RNG.1": 1
},
"FIA": {
"FIA_UAU.4": 1,
"FIA_UAU.5": 1,
"FIA_UID.1": 1
},
"FTP": {
"FTP_ITC.1": 1
}
},
"certification_process": {
"ConfidentialDocument": {
"Application on MultiApp V4 Revision A, Version 3, 10 August 2018, T\u00dcV Informationstechnik GmbH (confidential document) [10] Configuration List BSI-DSZ-CC-1003-2018, Configuration List for Smart Meter Gateway Security": 1,
"Target of Security Module for Smart Meter Gateway, D1359877, Version 2.1, 3 August 2018, Gemalto (confidential document) [7] Security Target Lite BSI-DSZ-CC-1003-2018, Security Target Lite of Security Module for Smart": 1,
"being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification": 1,
"v1.1,Version 1.2, 3 August 2018, and File LIS_SMGWSMV11_CAR_LBL03_1.65.1.7.1.5.1.20, Gemalto (confidential document) [11] Preparation Guidance for Smart Meter Gateway Security Module V1.1, D1393787, Release 1.2, 3": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 4
}
},
"cplc_data": {},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"PACE": {
"PACE": 7
},
"TLS": {
"TLS": {
"TLS": 4
}
}
},
"crypto_scheme": {
"KA": {
"KA": 1,
"Key Agreement": 7
},
"MAC": {
"MAC": 3
}
},
"device_model": {},
"ecc_curve": {},
"eval_facility": {
"Serma": {
"Serma Safety \u0026 Security": 1
},
"TUV": {
"T\u00dcV Informationstechnik": 3
}
},
"hash_function": {
"JH": {
"JH": 1
},
"SHA": {
"SHA2": {
"SHA-2": 1
}
}
},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RNG": 2
}
},
"side_channel_analysis": {
"FI": {
"malfunction": 1
},
"other": {
"JIL": 5
}
},
"standard_id": {
"BSI": {
"AIS 1": 1,
"AIS 14": 1,
"AIS 19": 1,
"AIS 20": 4,
"AIS 25": 1,
"AIS 26": 3,
"AIS 31": 2,
"AIS 32": 1,
"AIS 34": 2,
"AIS 35": 2,
"AIS 36": 4,
"AIS 37": 1,
"AIS 38": 1,
"AIS 46": 1
},
"FIPS": {
"FIPS 180-4": 2,
"FIPS 186-3": 6,
"FIPS 197": 2,
"FIPS PUB 180-4": 1,
"FIPS PUB 186-3": 1,
"FIPS PUB 197": 1
},
"ISO": {
"ISO/IEC 10116": 2,
"ISO/IEC 15408": 4,
"ISO/IEC 17065": 2,
"ISO/IEC 18045": 4,
"ISO/IEC 7816-4": 1
},
"RFC": {
"RFC 4493": 2,
"RFC 5639": 7
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 7
}
},
"constructions": {
"MAC": {
"CMAC": 5
}
}
},
"technical_report_id": {
"BSI": {
"BSI 7148": 1,
"BSI TR-03109-2": 9,
"BSI TR-03109-3": 2,
"BSI TR-03110-2": 1,
"BSI TR-03110-3": 1,
"BSI TR-03116-3": 2,
"BSI TR-3109-2": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"Gemalto": {
"Gemalto": 27
},
"Infineon": {
"Infineon": 11,
"Infineon Technologies AG": 2
}
},
"vulnerability": {}
},
"report_metadata": {
"/Author": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"/CreationDate": "D:20180920083559+02\u002700\u0027",
"/Creator": "Writer",
"/Keywords": "\"Common Criteria, Certification, Zertifizierung, Smart Meter, Security Module, Gemalto\"",
"/ModDate": "D:20180928133832+02\u002700\u0027",
"/Producer": "LibreOffice 5.2",
"/Subject": "Smart Meter Gateway Security Module Application on MultiApp V4 Revision A",
"/Title": "Certification Report BSI-DSZ-CC-1003-2018",
"pdf_file_size_bytes": 899116,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"https://www.bsi.bund.de/",
"https://www.bsi.bund.de/zertifizierung",
"http://www.sogisportal.eu/",
"http://www.commoncriteriaportal.org/",
"https://www.bsi.bund.de/zertifizierungsreporte",
"https://www.bsi.bund.de/AIS",
"http://www.commoncriteriaportal.org/cc/"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 32
},
"st_filename": "1003b_pdf.pdf",
"st_frontpage": null,
"st_keywords": {
"asymmetric_crypto": {
"ECC": {
"ECC": {
"ECC": 9
},
"ECDH": {
"ECDH": 1
},
"ECDSA": {
"ECDSA": 29
}
},
"FF": {
"DH": {
"DH": 16,
"Diffie-Hellman": 3
}
}
},
"cc_cert_id": {
"DE": {
"BSI-DSZ-CC-0891-V2-2016": 1,
"BSI-DSZ-CC-1003-2017": 1,
"BSI-DSZ-CC-1003-2018": 1
},
"FR": {
"ANSSI-CC-2017/54": 1
},
"NL": {
"CC-1": 5,
"CC-2": 2,
"CC-3": 3
}
},
"cc_claims": {
"A": {
"A.APPLET": 1,
"A.VERIFICATION": 3
},
"O": {
"O.PACE": 1
},
"OE": {
"OE.PACE": 1
},
"OSP": {
"OSP.RND": 3,
"OSP.SM": 1,
"OSP.VERIFICATION": 2
},
"T": {
"T.CONFID-APPLI-DATA": 1,
"T.CONFID-JCS-CODE": 1,
"T.CONFID-JCS-DATA": 2,
"T.EXE-CODE": 6,
"T.INSTALL": 2,
"T.INTEG-APPLI-CODE": 2,
"T.INTEG-APPLI-DATA": 2,
"T.INTEG-JCS-CODE": 3,
"T.INTEG-JCS-DATA": 2,
"T.NATIVE": 3,
"T.OBJ-DELETION": 4,
"T.PHYSICAL": 4,
"T.RESOURCES": 3,
"T.SID": 4
}
},
"cc_protection_profile_id": {
"BSI": {
"BSI-CC-PP- 0084-2014": 1,
"BSI-CC-PP-0073-2014": 1,
"BSI-CC-PP-0077-V2-2015": 3
}
},
"cc_sar": {
"ADV": {
"ADV_ARC.1": 1,
"ADV_FSP.4": 1,
"ADV_IMP.1": 1,
"ADV_TDS.3": 1
},
"AGD": {
"AGD_OPE": 1,
"AGD_OPE.1": 1,
"AGD_OPE_PLTF": 6,
"AGD_OPE_SMGW": 4,
"AGD_PRE": 1,
"AGD_PRE.1": 1,
"AGD_PRE_PLTF": 4,
"AGD_PRE_SMGW": 2
},
"ALC": {
"ALC_CMC.4": 1,
"ALC_CMS.4": 1,
"ALC_DEL.1": 1,
"ALC_DVS": 2,
"ALC_DVS.1": 1,
"ALC_LCD.1": 1,
"ALC_TAT.1": 1
},
"ASE": {
"ASE_CCL.1": 1,
"ASE_ECD.1": 1,
"ASE_INT.1": 1,
"ASE_OBJ.2": 1,
"ASE_REQ.2": 1,
"ASE_SPD.1": 1,
"ASE_TSS.1": 1
},
"ATE": {
"ATE_COV.2": 1,
"ATE_DPT.1": 1,
"ATE_FUN.1": 1,
"ATE_IND.2": 1
},
"AVA": {
"AVA_VAN": 2,
"AVA_VAN.5": 12
}
},
"cc_security_level": {
"EAL": {
"EAL 4": 2,
"EAL 5": 1,
"EAL 5 augmented": 1,
"EAL4": 2,
"EAL4 augmented": 1
}
},
"cc_sfr": {
"FCS": {
"FCS_CKM": 29,
"FCS_CKM.1": 13,
"FCS_CKM.2": 4,
"FCS_CKM.4": 23,
"FCS_CKM.4.1": 1,
"FCS_COP": 26,
"FCS_COP.1": 7,
"FCS_RNG": 7,
"FCS_RNG.1": 10,
"FCS_RNG.1.1": 2,
"FCS_RNG.1.2": 2
},
"FDP": {
"FDP_ACC": 1,
"FDP_ACC.1": 6,
"FDP_ACC.2": 7,
"FDP_ACC.2.1": 1,
"FDP_ACC.2.2": 1,
"FDP_ACF": 2,
"FDP_ACF.1": 4,
"FDP_ACF.1.1": 1,
"FDP_ACF.1.2": 1,
"FDP_ACF.1.3": 1,
"FDP_ACF.1.4": 1,
"FDP_ETC": 1,
"FDP_ETC.1": 3,
"FDP_ETC.1.1": 1,
"FDP_ETC.1.2": 1,
"FDP_IFC.1": 4,
"FDP_ITC": 1,
"FDP_ITC.1": 13,
"FDP_ITC.1.1": 1,
"FDP_ITC.1.2": 1,
"FDP_ITC.1.3": 1,
"FDP_ITC.2": 7,
"FDP_RIP": 1,
"FDP_RIP.1": 5,
"FDP_RIP.1.1": 1,
"FDP_SDI": 1,
"FDP_SDI.1": 1,
"FDP_SDI.2": 4,
"FDP_SDI.2.1": 2,
"FDP_SDI.2.2": 1,
"FDP_UCT": 1,
"FDP_UCT.1": 3,
"FDP_UCT.1.1": 1,
"FDP_UIT": 1,
"FDP_UIT.1": 3,
"FDP_UIT.1.1": 1,
"FDP_UIT.1.2": 1
},
"FIA": {
"FIA_ATD": 1,
"FIA_ATD.1": 5,
"FIA_ATD.1.1": 1,
"FIA_SOS": 1,
"FIA_SOS.1": 3,
"FIA_SOS.1.1": 1,
"FIA_UAU": 9,
"FIA_UAU.1": 3,
"FIA_UAU.4": 3,
"FIA_UAU.4.1": 1,
"FIA_UAU.5": 3,
"FIA_UAU.5.1": 1,
"FIA_UAU.5.2": 1,
"FIA_UID": 1,
"FIA_UID.1": 9,
"FIA_UID.1.1": 1,
"FIA_UID.1.2": 1,
"FIA_USB": 1,
"FIA_USB.1": 3,
"FIA_USB.1.2": 1,
"FIA_USB.1.3": 1
},
"FMT": {
"FMT_LIM": 6,
"FMT_LIM.1": 17,
"FMT_LIM.1.1": 2,
"FMT_LIM.2": 16,
"FMT_LIM.2.1": 2,
"FMT_MSA.3": 2,
"FMT_SMF": 1,
"FMT_SMF.1": 4,
"FMT_SMF.1.1": 1,
"FMT_SMR": 1,
"FMT_SMR.1": 3,
"FMT_SMR.1.1": 1,
"FMT_SMR.1.2": 1
},
"FPT": {
"FPT_EMS": 6,
"FPT_EMS.1": 7,
"FPT_EMS.1.1": 3,
"FPT_EMS.1.2": 3,
"FPT_FLS": 1,
"FPT_FLS.1": 4,
"FPT_FLS.1.1": 1,
"FPT_PHP": 1,
"FPT_PHP.3": 3,
"FPT_PHP.3.1": 1,
"FPT_TST": 1,
"FPT_TST.1": 4,
"FPT_TST.1.1": 1,
"FPT_TST.1.2": 1,
"FPT_TST.1.3": 1
},
"FTP": {
"FTP_ITC": 1,
"FTP_ITC.1": 7,
"FTP_ITC.1.1": 1,
"FTP_ITC.1.2": 1,
"FTP_ITC.1.3": 1,
"FTP_TRP.1": 2
}
},
"certification_process": {
"OutOfScope": {
"entities. As these external entities do not directly interact with the TOE, these entities are out of scope for this ST. During its pre-operational phases the TOE interacts with the Integrator and the": 1,
"out of scope": 1
}
},
"cipher_mode": {
"CBC": {
"CBC": 5
}
},
"cplc_data": {
"ICFab": {
"IC Fabricator": 1
},
"ICType": {
"IC Type": 1
}
},
"crypto_engine": {},
"crypto_library": {},
"crypto_protocol": {
"IKE": {
"IKE": 1
},
"PACE": {
"PACE": 72
},
"TLS": {
"TLS": {
"TLS": 19
}
}
},
"crypto_scheme": {
"KA": {
"Key Agreement": 9
},
"KEX": {
"Key Exchange": 1
},
"MAC": {
"MAC": 3
}
},
"device_model": {},
"ecc_curve": {
"Brainpool": {
"brainpoolP256r1": 1,
"brainpoolP384r1": 1,
"brainpoolP512r1": 1
},
"NIST": {
"NIST P-256": 1,
"NIST P-384": 1,
"P-256": 1,
"P-384": 1,
"secp256r1": 1,
"secp384r1": 1
}
},
"eval_facility": {},
"hash_function": {},
"ic_data_group": {},
"javacard_api_const": {},
"javacard_packages": {},
"javacard_version": {},
"os_name": {},
"pq_crypto": {},
"randomness": {
"RNG": {
"RND": 5,
"RNG": 10
}
},
"side_channel_analysis": {
"FI": {
"DFA": 1,
"Malfunction": 14,
"fault injection": 1,
"malfunction": 4,
"physical tampering": 4
},
"SCA": {
"DPA": 7,
"SPA": 2,
"physical probing": 4,
"side channel": 1,
"side channels": 1,
"timing attacks": 2
}
},
"standard_id": {
"BSI": {
"AIS 20": 1,
"AIS 31": 2,
"AIS 36": 1,
"AIS31": 1,
"AIS36": 1
},
"CC": {
"CCMB-2012-09-001": 1,
"CCMB-2012-09-002": 1,
"CCMB-2012-09-003": 1
},
"FIPS": {
"FIPS 197": 1,
"FIPS PUB 186-3": 1,
"FIPS PUB 46-3": 1,
"FIPS180-4": 1,
"FIPS186": 3,
"FIPS197": 2,
"FIPS46-3": 1
},
"ISO": {
"ISO/IEC 10116": 2
},
"PKCS": {
"PKCS#3": 1
},
"RFC": {
"RFC 2409": 2,
"RFC 4493": 2,
"RFC 4993": 1,
"RFC 5639": 1,
"RFC5639": 4
},
"X509": {
"X.509": 2
}
},
"symmetric_crypto": {
"AES_competition": {
"AES": {
"AES": 10,
"AES-": 1
}
},
"DES": {
"DES": {
"DES": 1
}
},
"constructions": {
"MAC": {
"CMAC": 3
}
}
},
"technical_report_id": {
"BSI": {
"BSI TR-03109-3": 1,
"BSI TR-03110-1": 1,
"BSI TR-03110-2": 1,
"BSI TR-03110-3": 1,
"BSI TR-03116-3": 1
}
},
"tee_name": {},
"tls_cipher_suite": {},
"vendor": {
"Gemalto": {
"Gemalto": 496
},
"Infineon": {
"Infineon": 6
}
},
"vulnerability": {}
},
"st_metadata": {
"/Author": "F.GUERIN",
"/CreationDate": "D:20180803120200+02\u002700\u0027",
"/Creator": "Microsoft\u00ae Word 2013",
"/Keywords": "Security Target, CC, Smart Meter",
"/ModDate": "D:20180803120200+02\u002700\u0027",
"/Producer": "Microsoft\u00ae Word 2013",
"/Subject": "SM for Smart Meter (Public Version)",
"/Title": "Security Target of Security Module for Smart Meter Gateway (PUBLIC version) BSI-DSZ-CC-1003-2017 TOE NAME: Smart Meter Gateway SM applet on MultiApp V4",
"pdf_file_size_bytes": 2286486,
"pdf_hyperlinks": {
"_type": "Set",
"elements": [
"http://www.sogisportal.eu/documents/cc/common/JIL-Collection-of-Developer-Evidence-v1-5.pdf",
"http://csrc.nist.gov/publications/fips/fips180-4/fips-180-4.pdf"
]
},
"pdf_is_encrypted": false,
"pdf_number_of_pages": 79
}
},
"protection_profiles": {
"_type": "Set",
"elements": [
{
"_type": "sec_certs.sample.protection_profile.ProtectionProfile",
"pp_eal": null,
"pp_ids": null,
"pp_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/ppfiles/pp0077V2b_pdf.pdf",
"pp_name": "Protection Profile for the Security Module of a Smart Meter Gateway (Security Module PP) - ..."
}
]
},
"report_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003a_pdf.pdf",
"scheme": "DE",
"security_level": {
"_type": "Set",
"elements": [
"AVA_VAN.5",
"EAL4"
]
},
"st_link": "https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1003b_pdf.pdf",
"state": {
"_type": "sec_certs.sample.cc.CCCertificate.InternalState",
"cert": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "bd54eb702e1947dac6a3ec5a67e202a9796ee8c7656efb7a4d797acd924a4256",
"txt_hash": "f27660122bfd0806d2bc6349b88ff20f1355214d2ae025ed1c9802388e34b0a7"
},
"report": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "816b42d78af6250abeae0a03ea39a6e129c268fe4a44e7ae17f3eaa4fce68ce4",
"txt_hash": "93e9bc9c461f8eb070e2594cf01d53155b11d3a57af631fcc69e820580e024fb"
},
"st": {
"_type": "sec_certs.sample.cc.CCCertificate.DocumentState",
"convert_garbage": false,
"convert_ok": true,
"download_ok": true,
"extract_ok": true,
"pdf_hash": "cf320913a582afd299839285636da64608d093a6d96e2ef6d72988533fd0443e",
"txt_hash": "dd5dec878c2c251457cc5c00ab8293f5f0420adfb4a6ddd6253d198c01fa33ee"
}
},
"status": "active"
}