name |
X0mail |
Arbit Data Diode 10 GbE v1.00 |
category |
Other Devices and Systems |
Boundary Protection Devices and Systems |
scheme |
NO |
DE |
status |
archived |
active |
not_valid_after |
01.09.2019 |
07.04.2026 |
not_valid_before |
23.02.2010 |
07.04.2021 |
cert_link |
|
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1096c_pdf.pdf |
report_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/20100223_SERTIT-008CR_issue201.0.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1096a_pdf.pdf |
st_link |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/XOmail_Version_14.2_Security_Target_739_20597_aaaa_sc_ed10-public.pdf |
https://www.commoncriteriaportal.org/nfs/ccpfiles/files/epfiles/1096b_pdf.pdf |
manufacturer |
Thales Norway AS |
Arbit Cyber Defence Systems ApS |
manufacturer_web |
https://www.thales.no/ |
https://arbitcds.com |
security_level |
EAL4 |
ALC_FLR.1, EAL7+ |
dgst |
f310fe4b0c9c7eb1 |
1c667ea8ba56a5db |
heuristics/cert_id |
SERTIT-014 |
BSI-DSZ-CC-1096-2021 |
heuristics/cert_lab |
[] |
BSI |
heuristics/cpe_matches |
{} |
{} |
heuristics/verified_cpe_matches |
{} |
{} |
heuristics/related_cves |
{} |
{} |
heuristics/direct_transitive_cves |
{} |
{} |
heuristics/indirect_transitive_cves |
{} |
{} |
heuristics/extracted_sars |
ADV_RCR.1, AVA_VLA.2, ASE_INT.1, ADV_HLD.2, AGD_USR.1, ADV_FSP.2, ALC_CMC.4, AVA_SOF.1, ADV_IMP.1, ASE_ECD.1, ATE_COV.2, ASE_TSS.1, ALC_TAT.1, AVA_MSU.2, ASE_SPD.1, AVA_VAN.5, ALC_DEL.1, AGD_ADM.1, ALC_LCD.1, AGD_OPE.1, AGD_PRE.1, ALC_CMS.4, ATE_FUN.1, ADV_DVS.1, ADV_ARC.1, ASE_OBJ.2, ADV_TDS.3, ATE_DPT.1, ASE_REQ.2, ALC_DVS.1, ATE_IND.2, ADV_LLD.1, ASE_CCL.1, ADV_SPM.1 |
ALC_LCD.2, ALC_FLR.1, ALC_CMS.5, ALC_DEL.1, ALC_DVS.2, ALC_TAT.3, ALC_CMC.5 |
heuristics/extracted_versions |
- |
1.00 |
heuristics/prev_certificates |
{} |
{} |
heuristics/next_certificates |
{} |
{} |
heuristics/report_references/directly_referenced_by |
{} |
{} |
heuristics/report_references/directly_referencing |
{} |
{} |
heuristics/report_references/indirectly_referenced_by |
{} |
{} |
heuristics/report_references/indirectly_referencing |
{} |
{} |
heuristics/scheme_data |
|
|
heuristics/st_references/directly_referenced_by |
{} |
{} |
heuristics/st_references/directly_referencing |
{} |
{} |
heuristics/st_references/indirectly_referenced_by |
{} |
{} |
heuristics/st_references/indirectly_referencing |
{} |
{} |
heuristics/protection_profiles |
{} |
{} |
maintenance_updates |
|
|
protection_profiles |
|
|
protection_profile_links |
{} |
{} |
pdf_data/cert_filename |
|
1096c_pdf.pdf |
pdf_data/cert_frontpage |
|
|
pdf_data/cert_keywords/cc_cert_id |
|
|
pdf_data/cert_keywords/cc_protection_profile_id |
|
|
pdf_data/cert_keywords/cc_security_level |
|
- EAL:
- EAL 2: 1
- EAL 4: 1
- EAL 5: 1
- EAL 7: 1
- EAL 7 augmented: 1
|
pdf_data/cert_keywords/cc_sar |
|
|
pdf_data/cert_keywords/cc_sfr |
|
|
pdf_data/cert_keywords/cc_claims |
|
|
pdf_data/cert_keywords/vendor |
|
|
pdf_data/cert_keywords/eval_facility |
|
|
pdf_data/cert_keywords/symmetric_crypto |
|
|
pdf_data/cert_keywords/asymmetric_crypto |
|
|
pdf_data/cert_keywords/pq_crypto |
|
|
pdf_data/cert_keywords/hash_function |
|
|
pdf_data/cert_keywords/crypto_scheme |
|
|
pdf_data/cert_keywords/crypto_protocol |
|
|
pdf_data/cert_keywords/randomness |
|
|
pdf_data/cert_keywords/cipher_mode |
|
|
pdf_data/cert_keywords/ecc_curve |
|
|
pdf_data/cert_keywords/crypto_engine |
|
|
pdf_data/cert_keywords/tls_cipher_suite |
|
|
pdf_data/cert_keywords/crypto_library |
|
|
pdf_data/cert_keywords/vulnerability |
|
|
pdf_data/cert_keywords/side_channel_analysis |
|
|
pdf_data/cert_keywords/technical_report_id |
|
|
pdf_data/cert_keywords/device_model |
|
|
pdf_data/cert_keywords/tee_name |
|
|
pdf_data/cert_keywords/os_name |
|
|
pdf_data/cert_keywords/cplc_data |
|
|
pdf_data/cert_keywords/ic_data_group |
|
|
pdf_data/cert_keywords/standard_id |
|
- ISO:
- ISO/IEC 15408: 2
- ISO/IEC 18045: 2
|
pdf_data/cert_keywords/javacard_version |
|
|
pdf_data/cert_keywords/javacard_api_const |
|
|
pdf_data/cert_keywords/javacard_packages |
|
|
pdf_data/cert_keywords/certification_process |
|
|
pdf_data/cert_metadata |
|
- /Author: Bundesamt für Sicherheit in der Informationstechnik
- /CreationDate: D:20210414123708+02'00'
- /Creator: Writer
- /Keywords: Common Criteria, Certification, Zertifizierung, Arbit, Data Diode, EAL7
- /ModDate: D:20210414123809+02'00'
- /Producer: LibreOffice 6.3
- /Subject: Common Criteria Certification
- /Title: Certification Report BSI-DSZ-CC-1096-2021
- pdf_file_size_bytes: 237483
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 1
|
pdf_data/report_filename |
20100223_SERTIT-008CR_issue201.0.pdf |
1096a_pdf.pdf |
pdf_data/report_frontpage |
|
- DE:
- cert_id: BSI-DSZ-CC-1096-2021
- cert_item: Arbit Data Diode 10 GbE
- cert_lab: BSI
- developer: Arbit Cyber Defence Systems ApS
- match_rules: ['(BSI-DSZ-CC-.+?) (?:for|For) (.+?) from (.*)']
|
pdf_data/report_keywords/cc_cert_id |
|
|
pdf_data/report_keywords/cc_protection_profile_id |
|
|
pdf_data/report_keywords/cc_security_level |
- EAL:
- EAL 4: 3
- EAL 4 augmented: 1
- EAL 4+: 17
- EAL1: 1
- EAL4+: 3
- EAL7: 1
|
- EAL:
- EAL 1: 1
- EAL 2: 2
- EAL 2+: 1
- EAL 4: 5
- EAL 5: 4
- EAL 7: 4
- EAL 7 augmented: 3
|
pdf_data/report_keywords/cc_sar |
- ADV:
- ADV_ARC.1: 1
- ADV_FSP.4: 1
- ADV_IMP.1: 1
- ADV_TDS.3: 1
- AGD:
- AGD_OPE.1: 1
- AGD_PRE.1: 1
- ALC:
- ALC_CMC.4: 1
- ALC_CMS.4: 1
- ALC_DEL.1: 1
- ALC_DVS.2: 6
- ALC_LCD.1: 1
- ALC_TAT.1: 1
- ASE:
- ASE_CCL.1: 1
- ASE_ECD.1: 1
- ASE_INT.1: 1
- ASE_OBJ.2: 1
- ASE_REQ.2: 1
- ASE_SPD.1: 1
- ASE_TSS.1: 1
- ATE:
- ATE_COV.2: 1
- ATE_DPT.1: 1
- ATE_FUN.1: 1
- ATE_IND.2: 1
- AVA:
|
- ADV:
- ADV_FSP: 1
- ADV_IMP: 1
- ADV_TDS: 1
- ALC:
- ALC_CMC.5: 1
- ALC_CMS: 1
- ALC_CMS.5: 1
- ALC_DEL.1: 1
- ALC_DVS.2: 1
- ALC_FLR: 3
- ALC_FLR.1: 4
- ALC_LCD.2: 1
- ALC_TAT.3: 1
|
pdf_data/report_keywords/cc_sfr |
- FDP:
- FDP_IFC.2: 2
- FDP_IFF.1: 2
|
- FDP:
- FDP_IFC.2: 2
- FDP_IFF.1: 2
|
pdf_data/report_keywords/cc_claims |
|
- A:
- A.INTEGRATOR: 1
- A.PHYSICAL: 1
- A.POWER: 1
- OE:
- OE.INTEGRATOR: 1
- OE.PHYSICAL: 1
- OE.POWER: 1
|
pdf_data/report_keywords/vendor |
|
|
pdf_data/report_keywords/eval_facility |
|
- TUV:
- TÜV Informationstechnik: 3
|
pdf_data/report_keywords/symmetric_crypto |
|
|
pdf_data/report_keywords/asymmetric_crypto |
|
|
pdf_data/report_keywords/pq_crypto |
|
|
pdf_data/report_keywords/hash_function |
|
|
pdf_data/report_keywords/crypto_scheme |
|
|
pdf_data/report_keywords/crypto_protocol |
|
|
pdf_data/report_keywords/randomness |
|
|
pdf_data/report_keywords/cipher_mode |
|
|
pdf_data/report_keywords/ecc_curve |
|
|
pdf_data/report_keywords/crypto_engine |
|
|
pdf_data/report_keywords/tls_cipher_suite |
|
|
pdf_data/report_keywords/crypto_library |
|
|
pdf_data/report_keywords/vulnerability |
|
|
pdf_data/report_keywords/side_channel_analysis |
|
|
pdf_data/report_keywords/technical_report_id |
|
|
pdf_data/report_keywords/device_model |
|
|
pdf_data/report_keywords/tee_name |
|
|
pdf_data/report_keywords/os_name |
|
|
pdf_data/report_keywords/cplc_data |
|
|
pdf_data/report_keywords/ic_data_group |
|
|
pdf_data/report_keywords/standard_id |
- CC:
- CCMB-2009-07-001: 1
- CCMB-2009-07-002: 1
- CCMB-2009-07-003: 1
- CCMB-2009-07-004: 1
|
- BSI:
- AIS 1: 1
- AIS 14: 5
- AIS 35: 1
- AIS 45: 1
- ISO:
- ISO/IEC 15408: 4
- ISO/IEC 17065: 2
- ISO/IEC 18045: 4
|
pdf_data/report_keywords/javacard_version |
|
|
pdf_data/report_keywords/javacard_api_const |
|
|
pdf_data/report_keywords/javacard_packages |
|
|
pdf_data/report_keywords/certification_process |
|
- ConfidentialDocument:
- Informationstechnik GmbH, (confidential document) [8] (reference not used) 7 See section 9.1 for details on used AIS. 18 / 22 BSI-DSZ-CC-1096-2021: 1
- being maintained, is not given any longer. In particular, prior to the dissemination of confidential documentation and information related to the TOE or resulting from the evaluation and certification: 1
- list for the TOE, Version 0.42, 2020-12-10, “Arbit Data Diode 10GbE - Configuration List” (confidential document) [11] “Arbit Data Diode 10GbE – Integration Guide”, Version 1.08, 2021-10-21, Confiware ApS and: 1
- “Arbit Data Diode 10GbE - Security Target”, Confiware ApS and Arbit Cyber Defence Systems ApS (confidential document) [7] Evaluation Technical Report, Version 2, 2021-01-20, “ETR Summary V2 – Arbit Data Diode 1.00: 1
|
pdf_data/report_metadata |
- /CreationDate: D:20100315130843
- /ModDate: D:20100315130843
- pdf_file_size_bytes: 542517
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 16
|
- /Author: Bundesamt für Sicherheit in der Informationstechnik
- /CreationDate: D:20210414122548+02'00'
- /Creator: Writer
- /Keywords: Common Criteria, Certification, Zertifizierung, Arbit, Data Diode, EAL7
- /ModDate: D:20210414123834+02'00'
- /Producer: LibreOffice 6.3
- /Subject: Common Criteria Certification
- /Title: Certification Report BSI-DSZ-CC-1096-2021
- pdf_file_size_bytes: 526938
- pdf_hyperlinks: http://www.commoncriteriaportal.org/cc/, https://www.sogis.eu/, https://www.bsi.bund.de/AIS, http://www.commoncriteriaportal.org/, https://www.bsi.bund.de/zertifizierung, https://www.bsi.bund.de/zertifizierungsreporte, https://www.bsi.bund.de/
- pdf_is_encrypted: False
- pdf_number_of_pages: 22
|
pdf_data/st_filename |
XOmail_Version_14.2_Security_Target_739_20597_aaaa_sc_ed10-public.pdf |
1096b_pdf.pdf |
pdf_data/st_frontpage |
|
|
pdf_data/st_keywords/cc_cert_id |
|
|
pdf_data/st_keywords/cc_protection_profile_id |
|
|
pdf_data/st_keywords/cc_security_level |
|
|
pdf_data/st_keywords/cc_sar |
- ACM:
- ACM_AUT.1: 10
- ACM_AUT.1.1: 1
- ACM_CAP.3: 1
- ACM_CAP.4: 20
- ACM_SCP.2: 7
- ADO:
- ADO_DEL.1: 1
- ADO_DEL.2: 11
- ADO_IGS.1: 13
- ADV:
- ADV_DVS.1: 1
- ADV_FSP.1: 7
- ADV_FSP.2: 12
- ADV_HLD.1: 2
- ADV_HLD.2: 17
- ADV_IMP.1: 11
- ADV_LLD.1: 18
- ADV_RCR.1: 9
- ADV_SPM.1: 15
- AGD:
- AGD_ADM.1: 22
- AGD_USR.1: 16
- ALC:
- ALC_DVS.1: 9
- ALC_LCD.1: 9
- ALC_TAT.1: 6
- ATE:
- ATE_COV.2: 8
- ATE_DPT.1: 7
- ATE_FUN.1: 15
- ATE_IND.2: 10
- AVA:
- AVA_MSU.2: 15
- AVA_SOF.1: 10
- AVA_VLA.2: 15
|
|
pdf_data/st_keywords/cc_sfr |
- FAU:
- FAU_ARP.1: 9
- FAU_ARP.1.1: 1
- FAU_GEN.1: 33
- FAU_GEN.1.1: 1
- FAU_GEN.2: 16
- FAU_GEN.2.1: 1
- FAU_SAA.1: 8
- FAU_SAA.1.1: 1
- FAU_SAA.1.2: 1
- FAU_SAR.1: 20
- FAU_SAR.2: 15
- FAU_STG.1: 21
- FAU_STG.3: 15
- FAU_STG.4: 9
- FDP:
- FDP_ACC.1: 11
- FDP_ACC.1.1: 1
- FDP_ACF.1: 10
- FDP_ACF.1.1: 1
- FDP_ACF.1.2: 1
- FDP_ACF.1.3: 1
- FDP_ACF.1.4: 1
- FDP_ETC.2: 10
- FDP_ETC.2.1: 1
- FDP_ETC.2.2: 1
- FDP_ETC.2.3: 1
- FDP_ETC.2.4: 1
- FDP_IFC.1: 4
- FDP_IFC.2: 9
- FDP_IFC.2.1: 1
- FDP_IFC.2.2: 1
- FDP_IFF.2: 10
- FDP_IFF.2.1: 1
- FDP_IFF.2.2: 2
- FDP_IFF.2.3: 1
- FDP_IFF.2.4: 1
- FDP_IFF.2.5: 1
- FDP_IFF.2.6: 1
- FDP_IFF.2.7: 1
- FDP_ITC.2: 10
- FDP_ITC.2.1: 1
- FDP_ITC.2.2: 1
- FDP_ITC.2.3: 1
- FDP_ITC.2.4: 1
- FDP_ITC.2.5: 1
- FDP_ITT.1: 5
- FDP_ITT.1.1: 1
- FDP_RIP.2: 9
- FDP_RIP.2.1: 1
- FIA:
- FIA_AFL.1: 9
- FIA_AFL.1.1: 1
- FIA_AFL.1.2: 1
- FIA_ATD.1: 11
- FIA_ATD.1.1: 1
- FIA_UAU.2: 17
- FIA_UAU.2.1: 2
- FIA_UAU.5: 9
- FIA_UAU.5.1: 1
- FIA_UAU.5.2: 1
- FIA_UID.1: 4
- FIA_UID.2: 24
- FIA_USB.1: 13
- FIA_USB.1.1: 1
- FIA_USB.1.2: 1
- FIA_USB.1.3: 1
- FMT:
- FMT_MSA.1: 10
- FMT_MSA.1.1: 1
- FMT_MSA.3: 12
- FMT_MSA.3.1: 1
- FMT_MSA.3.2: 1
- FMT_MTD.1: 8
- FMT_MTD.1.1: 1
- FMT_SMF.1: 10
- FMT_SMF.1.1: 1
- FMT_SMR.1: 12
- FMT_SMR.1.1: 1
- FMT_SMR.1.2: 1
- FPT:
- FPT_AMT.1: 2
- FPT_FLS.1: 8
- FPT_FLS.1.1: 1
- FPT_ITT.1: 5
- FPT_ITT.1.1: 1
- FPT_RCV.1: 8
- FPT_RCV.1.1: 1
- FPT_RCV.2: 11
- FPT_RCV.2.1: 1
- FPT_RCV.2.2: 1
- FPT_RCV.4: 9
- FPT_RCV.4.1: 1
- FPT_RVM.1: 9
- FPT_RVM.1.1: 1
- FPT_SEP.3: 10
- FPT_SEP.3.1: 1
- FPT_SEP.3.2: 1
- FPT_SEP.3.3: 1
- FPT_STM.1: 7
- FPT_STM.1.1: 1
- FPT_TDC.1: 14
- FPT_TDC.1.1: 1
- FPT_TDC.1.2: 1
- FPT_TSE.1: 1
- FPT_TST.1: 11
- FPT_TST.1.1: 1
- FPT_TST.1.2: 1
- FPT_TST.1.3: 1
- FTA:
- FTA_SSL.3: 8
- FTA_SSL.3.1: 1
- FTA_TSE.1: 19
- FTP:
- FTP_ITC.1: 2
- FTP_TRP.1: 2
|
|
pdf_data/st_keywords/cc_claims |
- A:
- A.ADM_TRAINING: 4
- A.AUDIT_REVIEW: 3
- A.CONFIDENCE: 4
- A.INVALIDATE: 3
- A.NETWORK: 4
- A.NOTIFY: 3
- A.OS: 5
- A.PHYSICAL: 4
- A.PHYSICAL_LOC: 3
- A.USR_TRAINING: 3
- O:
- O.ACCESS_HIST: 13
- O.AUDIT: 13
- O.AUTO_LOGOUT: 10
- O.CMD_ACL: 7
- O.CMD_LOG: 16
- O.DAC: 8
- O.DIG_SIGN: 3
- O.ID_AUTH: 14
- O.LABELLING: 8
- O.LOCK: 8
- O.MAC: 9
- O.MAC_INTEGRITY: 10
- O.MANAGE: 6
- O.MESSAGING: 8
- O.RECOVER: 9
- O.REF_MONITOR: 8
- O.RESOURCE_SHARE: 7
- O.REUSE: 9
- O.ROLES: 10
- O.ROLE_MNG: 7
- O.SELF_TEST: 8
- OE:
- OE.ACCOUNTABLE: 11
- OE.AUDIT: 13
- OE.ID_AUTH: 8
- OE.NETWORK: 17
- OE.PHYSICAL: 1
- OE.TRAF_SEPARATION: 11
|
- A:
- A.INTEGRATOR: 3
- A.PHYSICAL: 3
- A.POWER: 3
- O:
- OE:
- OE.INTEGRATOR: 4
- OE.PHYSICAL: 4
- OE.POWER: 4
- T:
|
pdf_data/st_keywords/vendor |
|
|
pdf_data/st_keywords/eval_facility |
|
|
pdf_data/st_keywords/symmetric_crypto |
|
|
pdf_data/st_keywords/asymmetric_crypto |
|
|
pdf_data/st_keywords/pq_crypto |
|
|
pdf_data/st_keywords/hash_function |
|
|
pdf_data/st_keywords/crypto_scheme |
|
|
pdf_data/st_keywords/crypto_protocol |
|
|
pdf_data/st_keywords/randomness |
|
|
pdf_data/st_keywords/cipher_mode |
|
|
pdf_data/st_keywords/ecc_curve |
|
|
pdf_data/st_keywords/crypto_engine |
|
|
pdf_data/st_keywords/tls_cipher_suite |
|
|
pdf_data/st_keywords/crypto_library |
|
|
pdf_data/st_keywords/vulnerability |
|
|
pdf_data/st_keywords/side_channel_analysis |
|
|
pdf_data/st_keywords/technical_report_id |
|
|
pdf_data/st_keywords/device_model |
|
|
pdf_data/st_keywords/tee_name |
|
|
pdf_data/st_keywords/os_name |
|
|
pdf_data/st_keywords/cplc_data |
|
|
pdf_data/st_keywords/ic_data_group |
|
|
pdf_data/st_keywords/standard_id |
- CC:
- CCMB-2005-08-001: 1
- CCMB-2005-08-002: 1
- CCMB-2005-08-003: 1
- ISO:
- RFC:
|
- CC:
- CCMB-2017-04-002: 1
- CCMB-2017-04-003: 1
|
pdf_data/st_keywords/javacard_version |
|
|
pdf_data/st_keywords/javacard_api_const |
|
|
pdf_data/st_keywords/javacard_packages |
|
|
pdf_data/st_keywords/certification_process |
- OutOfScope:
- MLS environment The protection of the LANs to which the MMHS servers and clients are connected is out of scope of this Security Target. It is assumed that the confidentiality of information is protected using: 1
- out of scope: 1
|
|
pdf_data/st_metadata |
- /Author: Thales Norway AS
- /CreationDate: D:20090430154245+02'00'
- /Creator: PDFCreator Version 0.9.3
- /Keywords:
- /ModDate: D:20090430154245
- /Producer: AFPL Ghostscript 8.13
- /Subject:
- /Title: XOmail Version 14.2 Security Target ed 10-public
- pdf_file_size_bytes: 2346280
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 111
|
- /Author: Arne Stig Peters (Confiware ApS), Rasmus Borch (Arbit Cyber Defence Systems ApS)
- /CreationDate: D:20201210124819+01'00'
- /Creator: pdflatex
- /Keywords: Common Criteria, EAL7, Arbit Cyber Defence Systems, Cross Domain, Data Diode, Unidirectional, Network, Cyber Defence, Optical
- /ModDate: D:20201210124819+01'00'
- /PTEX.Fullbanner: This is MiKTeX-pdfTeX 4.0.1 (1.40.21)
- /Producer: Latex
- /Subject:
- /Title: Arbit Data Diode 10GbE - Security Target Lite
- /Trapped: /False
- pdf_file_size_bytes: 332201
- pdf_hyperlinks: {}
- pdf_is_encrypted: False
- pdf_number_of_pages: 16
|
state/cert/convert_garbage |
False |
False |
state/cert/convert_ok |
False |
True |
state/cert/download_ok |
False |
True |
state/cert/extract_ok |
False |
True |
state/cert/pdf_hash |
Different |
Different |
state/cert/txt_hash |
Different |
Different |
state/report/convert_garbage |
False |
False |
state/report/convert_ok |
True |
True |
state/report/download_ok |
True |
True |
state/report/extract_ok |
True |
True |
state/report/pdf_hash |
Different |
Different |
state/report/txt_hash |
Different |
Different |
state/st/convert_garbage |
False |
False |
state/st/convert_ok |
True |
True |
state/st/download_ok |
True |
True |
state/st/extract_ok |
True |
True |
state/st/pdf_hash |
Different |
Different |
state/st/txt_hash |
Different |
Different |