FAN TRAY FAN TRAY FAN TRAY 13 11 9 7 5 3 1 2 4 6 8 10 12 14 5140 CR ITI CA L RE SE T MA JO R MI NO R US ER 1 US ER 2 US ER 3 5140SAP SERIAL 1 SERIAL 2 ALARM FILTER 1 2 0 1 2 10/100 link/Act ETH0 Service RESET STATUS Hot Swap link/Act ETH0 ETH1 10/100 5000SM 5001A-SW ASM-FB4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT ADM-FB8 HS OOS PWR OT 1 2 3 4 LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT 5 6 7 8 PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC FIPS 140-2 Security Policy FortiGate-5140 Chassis with FortiGate 5000 Series Blades FortiGate-5140 Chassis with FortiGate 5000 Series Blades FIPS 140-2 Security Policy Document Version: 2.2 Publication Date: May 20, 2014 Description: Documents FIPS 140-2 Level 2 Security Policy issues, compliancy and requirements for FIPS compliant operation. Firmware Version: FortiOS 4.0, build3830, 131223 Hardware Version: FortiGate-5140 (C4GL51) ASM-FB4 (AMC4F9) FortiGate-5001SX (P4CF76-) Shelf Manager (PN 21594 346) FortiGate-5001A-DW (P4CJ36-04) Alarm Panel (PN 21594 159) FortiGate-5001A-SW (P4CJ36-02) Air Filter (PN P10938-01) FortiGate-5001B (P4EV74) Blank Filler Panel - Front (PN P10945-01) ADM-FB8 (P4FC12) Blank Filler Panel - Rear (PN P10946-01) FortiGate-5140 Chassis with FortiGate 5000 Series Blades: FIPS 140-2 Security Policy 01-436-177867-20120805 for FortiOS 4.0 MR3 © Copyright 2014 Fortinet, Inc. This document may be freely reproduced and distributed whole and intact including this copyright notice. Trademarks Dynamic Threat Prevention System (DTPS), APSecure, FortiASIC, FortiBIOS, FortiBridge, FortiClient, FortiGate®, FortiGate Unified Threat Management System, FortiGuard®, FortiGuard-Antispam, FortiGuard-Antivirus, FortiGuard-Intrusion, FortiGuard-Web, FortiLog, FortiAnalyzer, FortiManager, Fortinet®, FortiOS, FortiPartner, FortiProtect, FortiReporter, FortiResponse, FortiShield, FortiVoIP, and FortiWiFi are trademarks of Fortinet, Inc. in the United States and/or other countries. The names of actual companies and products mentioned herein may be the trademarks of their respective owners. FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 1 http://docs.fortinet.com/ • Feedback Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Security Level Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Blade Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 AMC Module Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cryptographic Module Ports and Interfaces . . . . . . . . . . . . . . . . . . . . . 6 FortiGate-5001SX Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 FortiGate-5001A-DW and SW Blades . . . . . . . . . . . . . . . . . . . . . . 7 FortiGate-5001B Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ADM-FB8 AMC Component . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ASM-FB4 AMC Component . . . . . . . . . . . . . . . . . . . . . . . . . . 12 FortiGate-5140 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Web-Based Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Roles, Services and Authentication . . . . . . . . . . . . . . . . . . . . . . . . 15 Roles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 FIPS Approved Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Physical Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Operational Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Cryptographic Key Management . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Random Number Generation . . . . . . . . . . . . . . . . . . . . . . . . . 20 Key Zeroization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Algorithms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Cryptographic Keys and Critical Security Parameters . . . . . . . . . . . . . 21 Alternating Bypass Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Key Archiving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Electromagnetic Interference/Electromagnetic Compatibility (EMI/EMC) . . . . . 24 Mitigation of Other Attacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 FIPS 140-2 Compliant Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Enabling FIPS-CC mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Self-Tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Non-FIPS Approved Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Overview FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 2 http://docs.fortinet.com/ • Feedback Overview This document is a FIPS 140-2 Security Policy for Fortinet Incorporated’s FortiGate-5140 chassis with the FortiGate-5001SX, 5001A-DW, 5001A-SW and 5001B blade based Multi- Threat Security Systems. This policy describes how the FortiGate-5001SX, 5001A-DW, 5001A-SW and 5001B blades, when installed in the FortiGate-5140 chassis (hereafter referred to in combination as the ‘module’ or ‘modules’), meet the FIPS 140-2 security requirements and how to operate the modules in a FIPS compliant manner. This policy was created as part of the Level 2 FIPS 140-2 validation of the modules. This document contains the following sections: • Introduction • Security Level Summary • Module Description • Mitigation of Other Attacks • FIPS 140-2 Compliant Operation • Self-Tests • Non-FIPS Approved Services The Federal Information Processing Standards Publication 140-2 - Security Requirements for Cryptographic Modules (FIPS 140-2) details the United States Federal Government requirements for cryptographic modules. Detailed information about the FIPS 140-2 standard and validation program is available on the NIST (National Institute of Standards and Technology) website at http://csrc.nist.gov/groups/STM/cmvp/index.html. References This policy deals specifically with operation and implementation of the module in the technical terms of the FIPS 140-2 standard and the associated validation program. Other Fortinet product manuals, guides and technical notes can be found at the Fortinet technical documentation website at http://docs.forticare.com. Additional information on the entire Fortinet product line can be obtained from the following sources: • Find general product information in the product section of the Fortinet corporate website at http://www.fortinet.com/products. • Find on-line product support for registered products in the technical support section of the Fortinet corporate website at http://www.fortinet.com/support • Find contact information for technical or sales related questions in the contacts section of the Fortinet corporate website at http://www.fortinet.com/contact. • Find security information and bulletins in the FortiGuard Center of the Fortinet corporate website at http://www.fortinet.com/FortiGuardCenter. Introduction FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 3 http://docs.fortinet.com/ • Feedback Introduction The FortiGate product family spans the full range of network environments, from SOHO to service provider, offering cost effective systems for any size of application. FortiGate appliances detect and eliminate the most damaging, content-based threats from email and Web traffic such as viruses, worms, intrusions, inappropriate Web content and more in real time — without degrading network performance. In addition to providing application level firewall protection, FortiGate appliances deliver a full range of network-level services — VPN, intrusion prevention, web filtering, antivirus, antispam and traffic shaping — in dedicated, easily managed platforms. All FortiGate appliances employ Fortinet’s unique FortiASIC™ content processing chip and the powerful, secure, FortiOS™ firmware achieve breakthrough price/performance. The unique, ASIC-based architecture analyzes content and behavior in real time, enabling key applications to be deployed right at the network edge where they are most effective at protecting enterprise networks. They can be easily configured to provide antivirus protection, antispam protection and content filtering in conjunction with existing firewall, VPN, and related devices, or as complete network protection systems. The modules support High Availability (HA) in both Active-Active (AA) and Active-Passive (AP) configurations. FortiGate appliances support the IPSec industry standard for VPN, allowing VPNs to be configured between a FortiGate appliance and any client or gateway/firewall that supports IPSec VPN. FortiGate appliances also provide SSL VPN services using TLS 1.0 in the FIPS-CC mode of operation. Security Level Summary The modules meet the overall requirements for a FIPS 140-2 Level 2 validation. . Table 1: Summary of FIPS security requirements and compliance levels Security Requirement Compliance Level Cryptographic Module Specification 2 Cryptographic Module Ports and Interfaces 3 Roles, Services and Authentication 3 Finite State Model 2 Physical Security 2 Operational Environment 2 Cryptographic Key Management 2 EMI/EMC 2 Self-Tests 2 Design Assurance 3 Mitigation of Other Attacks 2 Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 4 http://docs.fortinet.com/ • Feedback Module Description The FortiGate modules (the blades and chassis in combination) are multiple chip, standalone cryptographic devices consisting of production grade components contained in a physically protected enclosure in accordance with FIPS 140-2 Level 2 requirements. The blades run the FortiOS firmware, perform all of the cryptographic functions and provide the input/output interfaces. The chassis provide power, cooling and physical protection for the modules as a whole. The chassis do not run FortiOS firmware. The modules are Internet devices that provide integrated firewall, VPN, antivirus, antispam, intrusion prevention, content filtering and traffic shaping capabilities. This FIPS 140-2 Security Policy specifically covers the firewall, IPSec and SSL-VPN capabilities of the modules. The antivirus, antispam, intrusion prevention, content filtering and traffic shaping capabilities of the modules can be used without compromising the FIPS approved mode of operation. The FortiGate-5001SX, 5001A-SW, 5001A-DW and 5001B blades are multiple chip, standalone cryptographic modules consisting of production grade components contained in a physically protected enclosure (the FortiGate-5140 chassis) in accordance with FIPS 140-2 Level 2 requirements. The modules are Internet devices that provide integrated firewall, VPN, antivirus, antispam, intrusion prevention, content filtering and traffic shaping and HA capabilities. This FIPS 140-2 Security Policy specifically covers the firewall, IPSec and SSL-VPN capabilities of the modules. The antivirus, antispam, intrusion prevention, content filtering and traffic shaping capabilities of the modules can be used without compromising the FIPS approved mode of operation. The validated firmware version is FortiOS 4.0, build3830, 131223. Figure 1, Figure 2, Figure 3, Figure 4, Figure 5, Figure 6, Figure 7 and Figure 8 are representative of the modules tested. Chassis Descriptions The FortiGate-5140 has 3 hot swappable, internal ventilation fan units that draw in air from the bottom front of the chassis and expel it from the top rear. These fans are excluded from the requirements of FIPS 140-2, as they provide no security relevant function. The FortiGate-5140 supports uses two, hot-swappable, DC power entry modules (PEMs). These PEMs are excluded from the requirements of FIPS 140-2, as they provide no security relevant function. The FortiGate-5140 chassis uses an external DC power source. The FortiGate-5140 chassis supports removable Shelf Manager (2) and Shelf Alarm (1) panels. One Shelf-Manager and one Alarm Panel are installed by default. The FortiGate-5140 chassis includes slots for rear-panel blades. However, the rear panel slots are not populated in the validated configuration. Blade Descriptions The blades have a similar appearance and perform the same functions, but have different numbers and types of network interfaces in order to support different network configurations: Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 5 http://docs.fortinet.com/ • Feedback The FortiGate-5001SX blade has: • 8 Gigabit network interfaces with a status LED for each interface (4x Gigabit SFP, 4x 10/100/1000 BaseT) • 2 x86 compatible CPUs • 1 DB-9 Serial (console) port • 2 USB ports The FortiGate-5001A-DW blade has: • 2 network interfaces with a status LED for each network interface (2x 10/100/1000 BaseT) • 2 x86 compatible CPUs • 1 RJ-45 Serial (console) port • 2 USB ports • 1 dual-width AMC slot The FortiGate-5001A-SW blade has: • 2 network interfaces with a status LED for each network interface (2x 10/100/1000 BaseT); • 2 x86 compatible CPUs • 1 RJ-45 Serial (console) port • 2 USB ports • 1 single-width AMC slot The FortiGate-5001B blade has: • 10 network interfaces with a status LED for each network interface (2x 10/100/1000 BaseT, 8x 10Gbit SFP+) • 2 x86 compatible CPUs • 1 RJ-45 Serial (console) port • 2 USB ports • The FortiGate-5001B blade includes a 64G SSD drive AMC Module Descriptions The FortiGate-5001A blades support one single or dual-width optional Advanced Mezzanine Card (AMC) components as described above. The AMC components can provide hard disk support or additional network interfaces. The validated configuration uses the following AMC modules: • The ADM-FB8 dual width AMC networking module with 8x 1Gbit SFP fiber ports, installed in the FortiGate-5001A-DW blade. • The ASM-FB4 single width AMC networking module with 4x 1Gbit SFP fiber ports., installed in the FortiGate-5001A-SW blade. Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 6 http://docs.fortinet.com/ • Feedback Cryptographic Module Ports and Interfaces FortiGate-5001SX Blade Figure 1: FortiGate-5001SX Front Panel l Table 2: FortiGate-5001SX Status LEDs LED State Description PWR Green The Fortinet module is powered on. ACC Off or Flashing red The ACC LED flashes red when the Fortinet module accesses the FortiOS flash disk. The FortiOS flash disk stores the current FortiOS firmware build and configuration files. The system accesses the flash disk when starting up, during a firmware upgrade, or when an administrator is using the CLI or GUI to change the FortiOS configuration. Under normal operating conditions this LED flashes occasionally, but is mostly off. STA Green Normal operation. Red The Fortinet is starting or a fault condition exists. IPM Blue The Fortinet is ready to be hot-swapped (removed from the chassis). If the IPM light is blue and no other LEDs are lit the Fortinet module has lost power, possibly because of a loose or incorrectly aligned left extraction lever. Flashing Blue The Fortinet is changing from hot swap to running mode or from running mode to hot swap. Off Normal operation. The Fortinet module is in contact with the chassis backplane. 1, 2, 3, 4 Green The correct cable is connected to the gigabit SFP interface. Flashing Network activity at the gigabit SFP interface. 5, 6, 7, 8 Link LED Green The correct cable is inserted into this interface and the connected equipment has power. Flashing Network activity at this interface. Speed LED Green The interface is connected at 1000 Mbps. Amber The interface is connected at 100 Mbps. Unlit The interface is connected at 10 Mbps. PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC 1 2 3 4 SFP Gigabit fiber or copper 5 6 7 8 Gigabit Copper Console Port Power Status Module Position Link/Traffic USB Ports Extraction Lever Mounting Knot Mounting Knot Locking Screw Extraction Lever Flash Disk Access Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 7 http://docs.fortinet.com/ • Feedback Table 3: FortiGate-5001SX Front Panel Connectors and Ports FortiGate-5001A-DW and SW Blades Figure 2: FortiGate-5001A-DW Front Panel Figure 3: FortiGate-5001A-SW Front Panel Connector Type Speed Supported Logical Interfaces Description 1, 2, 3, 4 SFP 1Gbps Data input, data output, control input and status output Gigabit SFP interfaces that can accept fiber or copper gigabit transceivers. These interfaces only operate at 1000Mbps. 5, 6, 7, 8 RJ-45 10/100/1000 BaseT Data input, data output, control input and status output Copper gigabit connection to 10/100/1000Base-T copper networks. Console Port DB-9 9600 bps Control input, status output Optional connection to the management computer. Provides access to the command line interface (CLI). USB Ports USB N/A Key loading and archiving Optional connection for FortiUSB token. port1 and port2 10/100/1000 Copper Interfaces USB Fabric and Base network activity LEDs Double-width AMC opening RJ-45 Console Extraction Lever Retention Screw Extraction Lever Retention Screw IPM LED (board position) ACC OOS Power Status LEDs 5001A-SW port1 and port2 10/100/1000 Copper Interfaces USB Fabric and Base network activity LEDs Single-width AMC opening RJ-45 Console Extraction Lever Retention Screw Extraction Lever Retention Screw IPM LED (board position) ACC OOS Power Status LEDs Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 8 http://docs.fortinet.com/ • Feedback Table 4: FortiGate-5001A-DW and SW Status LEDs LED State Description 1,2 (Left LED) Green The correct cable is connected to the interface and the connected equipment has power. Flashing Green Network activity at the interface. Off No link is established. 1,2 (Right LED) Green Connection at 1 Gbps. Amber Connection at 100 Mbps. Off Connection at 10 Mbps. Base CH0 Green Base backplane interface 0(base1) is connected at 1 Gbps. Flashing Green Network activity at base backplane interface 0. Base CH1 Green Base backplane interface 1 (base2) is connected at 1 Gbps. Flashing Green Network activity at base backplane interface 1. Fabric CH0 Green Fabric backplane interface 0 (fabric1) is connected at 1 Gbps. Flashing Green Network activity at fabric backplane interface 0. Fabric CH1 Green Fabric backplane interface 1 (fabric2) is connected at 1 Gbps. Flashing Green Network activity at fabric backplane interface 1. ACC Off or Flashing green The ACC LED flashes green when the FortiGate-5001A blade accesses the FortiOS flash disk. The FortiOS flash disk stores the current FortiOS firmware build and configuration files. The system accesses the flash disk when starting up, during a firmware upgrade, or when an administrator is using the CLI or GUI to change the FortiOS configuration. Under normal operating conditions this LED flashes occasionally, but is mostly off. OOS Off Normal operation. Green A fault condition exists and the FortiGate- 5001A blade is out of service (OOS). This LED may also flash very briefly during normal startup. Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 9 http://docs.fortinet.com/ • Feedback Table 5: FortiGate-5001A-DW Front Panel Connectors and Ports FortiGate-5001B Blade Figure 4: FortiGate-5001B Front Panel Power Green The FortiGate-5001A blade is powered on. Status Green The FortiGate-5001A blade is powered on. IPM Blue The FortiGate-5001A is ready to be hot- swapped (removed from the chassis). If the IPM light is blue and no other LEDs are lit the FortiGate-5001A blade has lost power. Flashing Blue The FortiGate-5001A is changing from hot swap to running mode or from running mode to hot swap. Off Normal operation. The FortiGate-5001A blade is in contact with the chassis backplane. Connector Type Speed Supported Logical Interfaces Description 1, 2 RJ-45 10/100/1000 Base T Data input, data output, control input and status output Copper gigabit connection to 10/100/1000Base-T copper networks. CONSOLE RJ-45 9600 bps Control input, status output Optional connection to the management computer. Provides access to the command line interface (CLI). USB Ports USB N/A Key loading and archiving Optional connection for FortiUSB token. 1 MGMT 1 and MGMT 2 10/100/1000 Copper Management Interfaces 1 to 8 10 Gig SFP+ Interfaces USB Fabric and Base network activity LEDs RJ-45 Console Extraction Lever Retention Screw Extraction Lever Retention Screw IPM LED (board position) OOS LED STA LED PWR LED ACC LED Factory use Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 10 http://docs.fortinet.com/ • Feedback Table 6: FortiGate-5001B Status LEDs LED State Description 1 to 8 Green The correct cable is connected to the interface and the connected equipment has power. Flashing Green Network activity at the interface. Off No link is established. Base 1 Green Base backplane interface is connected at 1 Gbps. Flashing Green Network activity at base backplane interface. Base 2 Green Base backplane interface is connected at 1 Gbps. Flashing Green Network activity at base backplane interface. Fabric 1 Green Fabric backplane interface is connected at 10 Gbps. Flashing Green Network activity at fabric backplane interface. Fabric 2 Green Fabric backplane interface is connected at 10 Gbps. Flashing Green Network activity at fabric backplane interface. ACC Off or Flashing green The ACC LED flashes green when the FortiGate-5001B blade accesses the FortiOS flash disk. The FortiOS flash disk stores the current FortiOS firmware build and configuration files. The system accesses the flash disk when starting up, during a firmware upgrade, or when an administrator is using the CLI or GUI to change the FortiOS configuration. Under normal operating conditions this LED flashes occasionally, but is mostly off. OOS Off Normal operation. Green A fault condition exists and the FortiGate- 5001B blade is out of service (OOS). This LED may also flash very briefly during normal startup. Power Green The FortiGate-5001B blade is powered on. Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 11 http://docs.fortinet.com/ • Feedback Table 7: FortiGate-5001B Front Panel Connectors and Ports ADM-FB8 AMC Component Figure 5: ADM-FB8 AMC Component Status Off The FortiGate-5001B blade is powered on. Flashing The FortiGate-5001B is starting up. If this LED is flashing at any time other than system startup, a fault condition may exist. IPM Blue The FortiGate-5001B is ready to be hot- swapped (removed from the chassis). If the IPM light is blue and no other LEDs are lit the FortiGate-5001A blade has lost power. Flashing The FortiGate-5001B is changing from hot swap to running mode or from running mode to hot swap. Off Normal operation. The FortiGate-5001B blade is in contact with the chassis backplane. Connector Type Speed Supported Logical Interfaces Description 1 to 8 SFP+ 10Gbps Data input, data output, control input and status output MGMT1 and MGMT 2 RJ-45 10/100/1000 Base-T Data input, data output, control input and status output CONSOLE RJ-45 9600 bps Control input, status output Optional connection to the management computer. Provides access to the command line interface (CLI). USB Port USB N/A Optional connection for USB token. ADM-FB8 HS OOS PWR OT 1 2 3 4 LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT 5 6 7 8 Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 12 http://docs.fortinet.com/ • Feedback ASM-FB4 AMC Component Figure 6: ASM-FB4 AMC Component Table 8: ADM-FB8 Status LEDs LED State Description HS Blue Ejection latch open. Flashing Blue Ejection latch opened during system operation. OOS Reserved for future use. PWR Amber The module is properly inserted in the FortiGate unit. Off The module is not receiving power from the FortiGate unit. OT Reserved for future use LINK Green The correct cable is in use and the connected equipment has power. Off No link established. ACT Flashing Amber Network activity at this interface. Off No network activity at this interface. Table 9: ADM-FB8 Front Panel Connectors and Ports Connector Type Speed Supported Logical Interfaces Description 1-8 LC-SFP 1Gbps Data input, data output, control input and status output Accelerated gigabit SFP interfaces that can accept fiber or copper gigabit transceivers. Table 10: ASM-FB4 Status LEDs LED State Description HS Blue Ejection latch open. Flashing Blue Ejection latch opened during system operation. OOS Reserved for future use. PWR Amber The module is properly inserted in the FortiGate unit. Off The module is not receiving power from the FortiGate unit. ASM-FB4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 13 http://docs.fortinet.com/ • Feedback FortiGate-5140 Chassis Figure 7: FortiGate-5140 Front Panel OT Reserved for future use. LINK Green The correct cable is in use and the connected equipment has power. Off No link established. ACT Flashing Amber Network activity at this interface. Off No network activity as this interface. Table 11: ASM-FB4 Front Panel Connectors and Ports Connector Type Speed Supported Logical Interfaces Description Ports 1 to 4 SERDES compatible SX fiber 1000 BaseSX Data input, data output, control input and status output Fiber network connections. Table 10: ASM-FB4 Status LEDs LED State Description FAN TRAY FAN TRAY FAN TRAY 13 11 9 7 5 3 1 2 4 6 8 10 12 14 5140 CRITICAL RESET MAJO R MINOR USER1 USER2 USER3 5140SAP SERIAL 1 SERIAL 2 ALARM FILTER 1 2 0 1 2 10/100 link/Act ETH0 Service RESET STATUS Hot Swap link/Act ETH0 ETH1 10/100 5000SM 5001A-SW ASM-FB4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT ADM-FB8 HS OOS PWR OT 1 2 3 4 LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT 5 6 7 8 PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC Primary shelf manager Cooling fan trays 0, 1, 2 Front cable tray ESD socket Slot numbers Shelf alarm panel (SAP) Front accessible air filter Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 14 http://docs.fortinet.com/ • Feedback Figure 8: FortiGate-5140 Rear Panel Web-Based Manager The FortiGate web-based manager provides GUI based access to the module and is the primary tool for configuring the module. The manager requires a web browser on the management computer and an Ethernet connection between the FortiGate unit and the management computer. A web-browser that supports Transport Layer Security (TLS) 1.0 is required for remote access to the web-based manager when the module is operating in FIPS-CC mode. HTTP access to the web-based manager is not allowed in FIPS-CC mode and is disabled. 1 2 3 4 1 2 3 4 HS HS operate Alarm 1 2 3 4 1 2 3 4 HS HS operate Alarm -48V/-60 VDC nom RTN 1 2 3 4 1 2 3 4 -48V/-60 VDC nom RTN 1 2 3 4 1 2 3 4 B PEM PEM A Power Entry Module A (terminal block cover removed) Power Entry Module B Chassis ground connector (green) -48V/-60 VDC nom (black) RTN (red) RTN (red) Back cable tray ESD socket TERMINAL BLOCK COVER Remove terminal block cover and decable before removing PEM. TERMINAL BLOCK COVER Remove terminal block cover and decable before removing PEM. -48V RTN -48V/-60 VDC nom (black) Backplane slot filler panels Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 15 http://docs.fortinet.com/ • Feedback Figure 9: The FortiGate web-based manager Command Line Interface The FortiGate Command Line Interface (CLI) is a full-featured, text based management tool for the module. The CLI provides access to all of the possible services and configuration options in the module. The CLI uses a console connection or a network (Ethernet) connection between the FortiGate unit and the management computer. The console connection is a direct serial connection. Terminal emulation software is required on the management computer using either method. For network access, a Telnet or SSH client that supports the SSH v2.0 protocol is required (SSH v1.0 is not supported in FIPS- CC mode). Telnet access to the CLI is not allowed in FIPS-CC mode and is disabled. Roles, Services and Authentication Roles When configured in FIPS-CC mode, the module provides the following roles: • Crypto Officer • Network User The Crypto Officer role is initially assigned to the default ‘admin’ operator account. The Crypto Officer role has read-write access to all of the module’s administrative services. The initial Crypto Officer can create additional operator accounts. These additional accounts are assigned the Crypto Officer role and can be assigned a range of read/write or read only access permissions including the ability to create operator accounts. Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 16 http://docs.fortinet.com/ • Feedback The module provides a Network User role for end-users (Users). Network users can make use of the encrypt/decrypt services, but cannot access the module for administrative purposes. The module does not provide a Maintenance role. FIPS Approved Services The following tables detail the types of FIPS approved services available to each role, the types of access for each role and the Keys or CSPs they affect. The role names are abbreviated as follows: The access types are abbreviated as follows: Crypto Officer CO User U Read Access R Write Access W Execute Access E Table 12: Services available to Crypto Officers Service Access Key/CSP authenticate to module WE Operator Password, Diffie-Hellman Key, HTTP/TLS and SSH Server/Host Keys, HTTPS/TLS and SSH Session Authentication Keys, and HTTPS/TLS Session Encryption Keys, RNG Seed, RNG AES Key show system status WE N/A show FIPS-CC mode enabled/disabled (console/CLI only) WE N/A enable FIPS-CC mode of operation (console only) WE Configuration Integrity Key execute factory reset (zeroize keys, disable FIPS mode, console/CLI only) E See “Key Zeroization” on page 20 execute FIPS-CC on-demand self- tests (console only) E Configuration Integrity Key, Firmware Integrity Key add/delete operators and network users WE Operator Password, Network User Password set/reset operator and network user passwords WE Operator Password, Network User Password backup configuration file WE Configuration Encryption Key, Configuration Backup Key read/set/delete/modify module configuration WE N/A enable/disable alternating bypass mode WE N/A Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 17 http://docs.fortinet.com/ • Feedback Authentication The modules implement identity based authentication. Operators must authenticate with a user-id and password combination to access the modules remotely or locally via the console. Remote operator authentication is done over HTTPS (TLS) or SSH. Password entry is obfuscated using asterisks and the module does not provide feedback on the authentication process - i.e. the module does not indicate if the password or the user/operator account is incorrect for a failed authentication attempt. By default, Network User access to the modules is based on firewall policy and authentication by IP address or fully qualified domain names. Network Users can optionally be forced to authenticate to the modules using a username/password combination to enable use of the IPSec VPN encrypt/decrypt or bypass services. For Network Users invoking the SSL-VPN encrypt/decrypt services, the modules support authentication with a user-id/password combination. Network User authentication is done over HTTPS and does not allow access to the modules for administrative purposes. Note that operator authentication over HTTPS/SSH and Network User authentication over HTTPS are subject to a limit of 3 failed authentication attempts in 1 minute. Operator authentication using the console is not subject to a failed authentication limit, but the number of authentication attempts per minute is limited by the bandwidth available over the serial connection. read/set/delete/modify IPSec/SSL VPN configuration N/A IPSec: IPSec Manual Authentication Key, IPSec Manual Encryption Key, IKE Pre-Shared Key, IKE RSA Key SSL: HTTPS/TLS Server/Host Key, HTTPS/TLS Session Authentication Key, HTTPS/TLS SSH Session Encryption Key read/set/delete/modify HA configuration WE HA Password, HA Encryption Key execute firmware update E Firmware Update Key read log data WE N/A delete log data (console/CLI only) N/A N/A execute system diagnostics (console/CLI only) WE N/A Table 13: Services available to Network Users Service/CSP Access Key/CSP authenticate to module E Network User Password, Diffie-Hellman Key, HTTPS/TLS Server/Host Key, HTTPS/TLS Session Authentication Key, HTTPS/TLS Session Encryption Key, RNG Seed, RNG AES Key IPSec VPN controlled by firewall policies E Diffie-Hellman Key, IKE and IPSec Keys, RNG Seed, RNG AES Key SSL VPN controlled by firewall policies E Network User Password, Diffie-Hellman Key, HTTPS/TLS Server/Host Key, HTTPS/TLS Session Authentication Key, HTTPS/TLS Session Encryption Key, RNG Seed, RNG AES Key Table 12: Services available to Crypto Officers Service Access Key/CSP Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 18 http://docs.fortinet.com/ • Feedback The minimum password length is 8 characters when in FIPS-CC mode (maximum password length is 32 characters). The password may contain any combination of upper- and lower-case letters, numbers, and printable symbols; allowing for 94 possible characters. The odds of guessing a password are 1 in 94^8 which is significantly lower than one in a million. Recommended procedures to increase the password strength are explained in “FIPS 140-2 Compliant Operation” on page 25. For Network Users invoking the IPSec VPN encrypt/decrypt services, the module acts on behalf of the Network User and negotiates a VPN connection with a remote module. The strength of authentication for IPSec services is based on the authentication method defined in the specific firewall policy: IPSec manual authentication key, IKE pre-shared key or IKE RSA key (RSA certificate). The odds of guessing the authentication key for each IPSec method is: • 1 in 1640 for the IPSec Manual Authentication key (based on a 40 digit, hexadecimal key) • 1 in 948 for the IKE Pre-shared Key (based on an 8 character, ASCII printable key) • 1 in 21024 for the IKE RSA Key (based on a 1024bit RSA key size) Therefore the minimum odds of guessing the authentication key for IPSec is 1 in 948 , based on the IKE Pre-shared key. Physical Security The modules meet FIPS 140-2 Security Level 2 requirements by using production grade components and an opaque, sealed enclosure. Access to the enclosure is restricted through the use of tamper-evident seals to secure the overall enclosure. The seals are serialized red wax/plastic with black lettering that reads “Fortinet Security Seal”. The tamper seals are not applied at the factory prior to shipping. It is the responsibility of the Crypto Officer to apply the seals before use to ensure full FIPS 140-2 compliance. Once the seals have been applied, the Crypto Officer must develop an inspection schedule to verify that the external enclosure of the module and the tamper seals have not been damaged or tampered with in any way. The Crypto Officer is also responsible for securing and controlling any unused seals. The surfaces should be cleaned with 99% Isopropyl alcohol to remove dirt and oil before applying the seals. Ensure the surface is completely clean and dry before applying the seals. If a seal needs to be re-applied, completely remove the old seal and clean the surface with an adhesive remover before following the instructions for applying a new seal. Additional seals can be ordered through your Fortinet sales contact. Reference the following SKU when ordering: FIPS-SEAL-RED. Specify the number of seals required based on the specific module as described below. The FortiGate-5140 uses 25 seals to secure: • the blades, shelf-manager, shelf-alarm, blank face plates and filter (1 seals, see Figure 10) • the rear panel blank face plates (13 seals, see Figure 11) Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 19 http://docs.fortinet.com/ • Feedback Figure 10: FortiGate-5140 front seals Figure 11: FortiGate-5140 rear panel seals FAN TRAY FAN TRAY FAN TRAY Fortinet Security Seal 01000 13 11 9 7 5 3 1 2 4 6 8 10 12 14 5140 CRITICAL RES ET MAJO R MINOR USE R1 USE R2 USE R3 5140SAP SERIAL 1 SERIAL 2 ALARM FILTER 1 2 0 1 2 10/100 link/Act ETH0 Service RESET STATUS Hot Swap link/Act ETH0 ETH1 10/100 5000SM Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 5001A-SW ASM-FB4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT ADM-FB8 HS OOS PWR OT 1 2 3 4 LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT LINK ACT 5 6 7 8 PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Seals 3 to 9 of 25 Seal 12 of 25 Seal 11 of 25 Seal 2 of 25 FortiGate-5001SX FortiGate-5001B FortiGate-5001A-DW FortiGate-5001A-SW ADM-FB8 ASM-FB4 Fortinet Security Seal 01000 Seal 1 of 25 Seal 11 of 25 1 2 3 4 1 2 3 4 HS HS operate Alarm 1 2 3 4 1 2 3 4 HS HS operate Alarm -48V/-60 VDC nom RTN 1 2 3 4 1 2 3 4 -48V/-60 VDC nom RTN 1 2 3 4 1 2 3 4 B PEM PEM A Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Fortinet Security Seal 01000 Seals 13 to 25 of 25 Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 20 http://docs.fortinet.com/ • Feedback Operational Environment The module consists of the combination of the FortiOS operating system and the FortiGate appliances. The FortiOS operating system can only be installed, and run, on a FortiGate appliance. The FortiOS operating system provides a proprietary and non- modifiable operating system. Cryptographic Key Management Random Number Generation The modules use a firmware based, deterministic random number generator that conforms to ANSI X9.31 Appendix A.2.4. The ANSI X9.31 RNG is seeded using a 128-bit AES seed key generated external to the module (estimated entropy 128 bits) and 256 bits of seed (estimated entropy 60 bits) gathered from a random pool filled with 64 bytes of system data and internal resources such as time, memory addresses, kernel ticks, and module identifiers. As the module's ANSI X9.31 RNG implementation only generates random values of size 128 bits, it would take multiple calls to form a 256-bit key. Each time a key is generated with a bit length of more than 128 bits, the key is refreshed with an additional 12 bits of entropy. The total estimated strength for the two calls required to form a 256 bit key would be at theoretical best 200 bits. Key Zeroization The zeroization process must performed under the direct control of the operator. The operator must be present to observe that the zeroization method has completed successfully. All keys except the following are zeroized by executing a factory reset: • ANSI X9.31 RNG AES Key • Firmware Update Key • Firmware Integrity Key • Configuration Integrity Key • Configuration Backup Key • SSH Server/Host Key • HTTPS/TLS Server/Host Key All keys and CSPs are zeroized by formatting the modules’ flash memory storage. To format the flash memory, connect a computer to the modules’ console port and reboot the module. Access the configuration menu by pressing any key when prompted (see example below). Select “F” to format the flash memory (boot device). Press any key to display configuration menu... [G]: Get firmware image from TFTP server. [F]: Format boot device. [B]: Boot with backup firmware and set as default. [I]: Configuration and information. [Q]: Quit menu and continue to boot with default firmware. [H]: Display this list of options. Enter G,F,B,I,Q,or H: Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 21 http://docs.fortinet.com/ • Feedback Algorithms Some algorithms may be classified as deprecated, restricted, or legacy-use. Please consult NIST SP 800-131A for details. The vendor makes no conformance claims to any key derivation function specified in SP 800-135rev1. References to the key derivation functions addressed in SP 800-135rev1 including IKE, SSH, and TLS are only listed to clarify the key types supported by the module. Keys related to IKE, SSH, and TLS are only used in the Approved mode under the general umbrella of a non-Approved Diffie-Hellman scheme, with no assurance claims to the underlying key derivation functions. Cryptographic Keys and Critical Security Parameters The following table lists all of the cryptographic keys and critical security parameters used by the module. The following definitions apply to the table: Table 14: FIPS Approved Algorithms Algorithm NIST Certificate Number RNG (ANSI X9.31 Appendix A) 1234 Triple-DES 1423, 1424, 1425,1572, 1573 AES 2276, 2277, 2278, 2607, 2608 SHA-1 1957, 1958, 1959, 2191, 2192 SHA-256 1957, 1958, 1959, 2191, 2192 HMAC SHA-1 1394, 1395, 1396,1615, 1616 HMAC SHA-256 1394, 1395, 1396,1615, 1616 RSA PKCS1 (digital signature creation and verification) 1168, 1169, 1334 Table 15: FIPS Allowed Algorithms Algorithm RSA (key establishment methodology provides 80 or 112 bits of encryption strength) Diffie-Hellman (key agreement; key establishment methodology provides between 80 and 201bits of encryption strength; non-compliant less than 80-bits of encryption strength) NDRNG Table 16: Non-FIPS Approved Algorithms Algorithm DES (disabled in FIPS-CC mode) MD5 (disabled in FIPS-CC mode except for use in the TLS protocol) HMAC MD5 (disabled in FIPS-CC mode) Key or CSP The key or CSP description. Storage Where and how the keys are stored Usage How the keys are used Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 22 http://docs.fortinet.com/ • Feedback Table 17: Cryptographic Keys and Critical Parameters used in FIPS-CC Mode Key or CSP Storage Usage Diffie-Hellman Keys SDRAM Plaintext Key agreement and key establishment IPSec Manual Authentication Key Flash RAM AES encrypted Used as IPSec Session Authentication Key IPSec Manual Encryption Key Flash RAM AES encrypted Used as IPSec Session Encryption Key IPSec Session Authentication Key SDRAM Plain-text IPSec peer-to-peer authentication using HMAC SHA-1 IPSec Session Encryption Key SDRAM Plain-text VPN traffic encryption/decryption using Triple-DES or AES IKE Pre-Shared Key Flash RAM AES encrypted Used to generate IKE protocol keys IKE Authentication Key SDRAM Plain-text IKE peer-to-peer authentication using HMAC SHA-1 (SKEYID_A) IKE Key Generation Key SDRAM Plain-text IPSec SA keying material (SKEYID_D) IKE Session Encryption Key SDRAM Plain-text Encryption of IKE peer-to-peer key negotiation using Triple-DES or AES (SKEYID_E) IKE RSA Key Flash Ram Plain text Used to generate IKE protocol keys RNG Seed (ANSI X9.31 Appendix A.2.4) Flash RAM Plain-text Seed used for initializing the RNG RNG AES Key (ANSI X9.31 Appendix A.2.4) Flash RAM Plain-text AES Seed key used with the RNG Firmware Update Key Flash RAM Plain-text Verification of firmware integrity when updating to new firmware versions using RSA public key Firmware Integrity Key Flash RAM Plain-text Verification of firmware integrity in the firmware integrity test using RSA public key HTTPS/TLS Server/Host Key Flash RAM Plain-text RSA private key used in the HTTPS/TLS protocols HTTPS/TLS Session Authentication Key SDRAM Plain-text HMAC SHA-1 key used for HTTPS/TLS session authentication HTTPS/TLS Session Encryption Key SDRAM Plain-text AES or Triple-DES key used for HTTPS/TLS session encryption SSH Server/Host Key Flash RAM Plain-text RSA private key used in the SSH protocol SSH Session Authentication Key SDRAM Plain-text HMAC SHA-1 key used for SSH session authentication SSH Session Encryption Key SDRAM Plain-text AES or Triple-DES key used for SSH session encryption Operator Password Flash RAM SHA-1 hash Used to authenticate operator access to the module Configuration Integrity Key Flash RAM Plain-text SHA-1 hash used for configuration/VPN bypass test Module Description FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 23 http://docs.fortinet.com/ • Feedback Alternating Bypass Feature The primary cryptographic function of the module is as a firewall and VPN device. The module implements two forms of alternating bypass for VPN traffic: policy based (for IPSec and SSL VPN) and interface based (for IPSec VPN only). Policy Based VPN Firewall policies with an action of IPSec or SSL-VPN mean that the firewall is functioning as a VPN start/end point for the specified source/destination addresses and will encrypt/decrypt traffic according to the policy. Firewall policies with an action of allow mean that the firewall is accepting/sending plaintext data for the specified source/destination addresses. A firewall policy with an action of accept means that the module is operating in a bypass state for that policy. A firewall policy with an action of IPSec or SSL-VPN means that the module is operating in a non-bypass state for that policy. Interface Based VPN Interface based VPN is supported for IPSec only. A virtual interface is created and any traffic routed to the virtual interface is encrypted and sent to the VPN peer. Traffic received from the peer is decrypted. Traffic through the virtual interface is controlled using firewall policies. However, unlike policy based VPN, the action is restricted to Accept or Deny and all traffic controlled by the policy is encrypted/decrypted. When traffic is routed over the non-virtual interfaced, the module is operating in a bypass state. When traffic is routed over the virtual interface, the module is operating in a non- bypass state. In both cases, two independent actions must be taken by a CO to create bypass firewall policies: the CO must create the bypass policy and then specifically enable that policy. Key Archiving The module supports key archiving to a management computer or USB token as part of a module configuration file backup. Operator entered keys are archived as part of the module configuration file. The configuration file is stored in plain text, but keys in the configuration file are either AES encrypted using the Configuration Encryption Key or stored as a keyed hash using HMAC-SHA-1 using the Configuration Backup Key. Configuration Encryption Key Flash RAM Plain-text AES key used to encrypt CSPs on the flash RAM and in the backup configuration file (except for operator passwords in the backup configuration file) Configuration Backup Key Flash RAM Plain-text HMAC SHA-1 key used to encrypt operator passwords in the backup configuration file Network User Password Flash RAM AES encrypted Used during network user authentication HA Password Flash RAM AES encrypted Used to authenticate FortiGate units in an HA cluster HA Encryption Key Flash RAM AES encrypted Encryption of traffic between units in an HA cluster using AES Table 17: Cryptographic Keys and Critical Parameters used in FIPS-CC Mode Key or CSP Storage Usage Mitigation of Other Attacks FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 24 http://docs.fortinet.com/ • Feedback Electromagnetic Interference/Electromagnetic Compatibility (EMI/EMC) The modules comply with EMI/EMC requirements for Class A (business use) devices as specified by Part 15, Subpart B, of the FCC rules. The following table lists the specific lab and FCC report information for the modules. Mitigation of Other Attacks The module includes a real-time Intrusion Prevention System (IPS) as well as antivirus protection, antispam and content filtering. Use of these capabilities is optional. The FortiOS IPS has two components: a signature based component for detecting attacks passing through the FortiGate appliance and a local attack detection component that protects the firewall from direct attacks. Functionally, signatures are similar to virus definitions, with each signature designed to detect a particular type of attack. The IPS signatures are updated through the FortiGuard IPS service. The IPS engine can also be updated through the FortiGuard IPS service. FortiOS antivirus protection removes and optionally quarantines files infected by viruses from web (HTTP), file transfer (FTP), and email (POP3, IMAP, and SMTP) content as it passes through the FortiGate modules. FortiOS antivirus protection also controls the blocking of oversized files and supports blocking by file extension. Virus signatures are updated through the FortiGuard antivirus service. The antivirus engine can also be updated through the FortiGuard antivirus service. FortiOS antispam protection tags (SMTP, IMAP, POP3) or discards (SMTP only) email messages determined to be spam. Multiple spam detection methods are supported including the FortiGuard managed antispam service. FortiOS web filtering can be configured to provide web (HTTP) content filtering. FortiOS web filtering uses methods such as banned words, address block/exempt lists, and the FortiGuard managed content service. Whenever a IPS, antivirus, antispam or filtering event occurs, the modules can record the event in the log and/or send an alert email to an operator. For complete information refer to the FortiGate Installation Guide for the specific module in question, the FortiGate Administration Guide and the FortiGate IPS Guide. Table 18: FCC Report Information Module Lab Information FCC Report Number FG-5001SX Compliance Certification Services Inc. 561F Monterey Road Morgan Hill, CA, 95037, USA (408) 463-0885 06U10772-1 FG-5001A-DW and SW Bay Area Compliance Laboratories Corp. 1274 Anvilwood Ave. Sunnyvale, CA 94089 (408) 732-9162 R0805134 FG-5001B The module is declared to conform with EMI/EMC requirements for Class A (business use) devices as specified by Part 15, Subpart B, of the FCC rules. N/A FIPS 140-2 Compliant Operation FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 25 http://docs.fortinet.com/ • Feedback FIPS 140-2 Compliant Operation FIPS 140-2 compliant operation requires both that you use the module in its FIPS-CC mode of operation and that you follow secure procedures for installation and operation of the FortiGate unit. You must ensure that: • The FortiGate unit is configured in the FIPS-CC mode of operation. • The FortiGate unit is installed in a secure physical location. • Physical access to the FortiGate unit is restricted to authorized operators. • Administrative passwords are at least 8 characters long. • Administrative passwords are changed regularly. • Administrator account passwords must have the following characteristics: • One (or more) of the characters should be capitalized • One (or more) of the characters should be numeric • One (or more) of the characters should be non alpha-numeric (e.g. punctuation mark) • Administration of the module is permitted using only validated administrative methods. These are: • Console connection • Web-based manager via HTTPS • Command line interface (CLI) access via SSH • Diffie-Hellman groups of less than less than 1024 bits (Group 5) are not used. • Client side RSA certificates must use 1024 bit or greater key sizes. • LDAP based authentication must use secure LDAP (LDAPS). • Only approved and allowed algorithms are used (see “Algorithms” on page 21). • The tamper evident seals are applied (see “Physical Security” on page 18). The module can be used in either of its two operation modes: NAT/Route or Transparent. NAT/Route mode applies security features between two or more different networks (for example, between a private network and the Internet). Transparent mode applies security features at any point in a network. The current operation mode is displayed on the web- based manager Status page and in the output of the get system status CLI command. Also, on LCD-equipped modules, Transparent mode is indicated by “FIPS-CC- TP” and NAT/Route by “FIPS-CC-NAT” on the LCD display. Enabling FIPS-CC mode To enable the FIPS 140-2 compliant mode of operation, the operator must execute the following command from the Local Console: config system fips set status enable end The Operator is required to supply a password for the admin account which will be assigned to the Crypto Officer role. The supplied password must be at least 8 characters long and correctly verified before the system will restart in FIPS-CC mode. Upon restart, the module will execute self-tests to ensure the correct initialization of the module’s cryptographic functions. After restarting, the Crypto Officer can confirm that the module is running in FIPS-CC mode by executing the following command from the CLI: Self-Tests FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 26 http://docs.fortinet.com/ • Feedback get system status If the module is running in FIPS-CC mode, the system status output will display the line: FIPS-CC mode: enable Note that enabling/disabling the FIPS-CC mode of operation will automatically invoke the key zeroization service. The key zeroization is performed immediately after FIPS-CC mode is enabled/disabled. Self-Tests The module executes the following self-tests during startup and initialization: • Firmware integrity test using RSA signatures • Configuration/VPN bypass test using HMAC SHA-1 • Triple-DES, CBC mode, encrypt known answer test • Triple-DES, CBC mode, decrypt known answer test • AES, CBC mode, encrypt known answer test • AES, CBC mode, decrypt known answer test • HMAC SHA-1 known answer test • SHA-1 known answer test (test as part of HMAC SHA-1 known answer test) • HMAC SHA-256 known answer test • SHA-256 known answer test (test as part of HMAC SHA-256 known answer test) • RSA signature generation known answer test • RSA signature verification known answer test • RNG known answer test The results of the startup self-tests are displayed on the console during the startup process. The startup self-tests can also be initiated on demand using the CLI command execute fips kat all (to initiate all self-tests) or execute fips kat (to initiate a specific self-test). When the self-tests are run, each implementation of an algorithm is tested - e.g. when the AES self-test is run, all AES implementations are tested. The module executes the following conditional tests when the related service is invoked: • Continuous RNG test • Continuous NDRNG test • RSA pairwise consistency test • Configuration/VPN bypass test using HMAC SHA-1 • Firmware load test using RSA signatures If any of the self-tests or conditional tests fail, the module enters an error state as shown by the console output below: Self-tests failed Entering error mode... The system is going down NOW !! The system is halted. All data output and cryptographic services are inhibited in the error state. Non-FIPS Approved Services FortiGate-5140 with 5000 Series Blades FIPS 140-2 Security Policy 01-436-177867-20120805 27 http://docs.fortinet.com/ • Feedback Non-FIPS Approved Services The module also provides the following non-FIPS approved services: • Configuration backups using password protection • LLTP and PPTP VPN If the above services are used, the module is not considered to be operating in the FIPS approved mode of operation.